Activated Exchanger Design & Rating Aspen 8.4
Activated Exchanger Design & Rating Aspen 8.4
Activated Exchanger Design & Rating Aspen 8.4
4
A Brief Tutorial (and supplement to training and online documentation)
Lauren Sittler, Product Management, Aspen Technology, Inc.
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 New Capabilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview of the User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Starting Activated EDR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 The EDR Dashboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Flowsheet Highlights and Flyovers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Operational Risk Flowsheet Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 The Activated EDR Summary Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Summary Table Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Converting Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Model Types Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Converting a Simple Model to Rigorous EDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Rigorous to Simple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
Introduction
Activated Exchanger Design & Rating (EDR) is a new Activated Analysis tool available within AspenTechs V8.4 simulators Aspen Plus and Aspen HYSYS. Like Activated Energy Analysis and Activated Economic Evaluation, Activated EDR helps process engineers quickly evaluate feasible design alternatives and immediately assess the impact on flowsheet capital and operating expenditures. Activated EDR provides an easy way to convert simple heat exchanger models to rigorous models, and provides quick access to rigorous model details. The EDR dashboard uses visual indicators to convey information about heat exchangers model status and shows all operational risks, if any, that have been detected in rigorous heat exchanger models.
New Capabilities
Convert simple heat exchanger models into rigorous designs from the flowsheet to obtain a fully rigorous, costoptimized geometry that accurately models thermal and hydraulic performance Easily track and change the model-type for all heat exchanger equipment in the simulation Instantly view operational risks, such as vibration and erosion, right from the flowsheet
Click the heat exchanger icon to turn it on and click the close button to turn it off (Figure 2). Opening and closing the EDR dashboard does not affect the EDR models in your flowsheet; it will not automatically convert a simple model to rigorous and vice versa. It will simply reveal more information about the heat exchanger models in your flowsheet.
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
Model Status Simple heat exchanger Rigorous exchanger Rigorous exchanger, calculation error
Operation Risk Level Simple heat exchanger Rigorous exchanger, no warnings Rigorous exchanger, operation warnings detected Rigorous exchanger, serious risks detected
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
Summary Table Organization Column 1: Exchanger Name Displays the title of the unit operation block for that exchanger. If the model is rigorous, this title will be a link to open the unit operation form.
Column 2: Contains the location of an exchanger if its in a subflowsheet or hierarchy block. Subflowsheet: Contains a toggle button that displays either the EDR model type or reads Convert for Column 3: simple models. Click on this button to go directly to the form that allows you to convert this Model Status exchanger from simple to rigorous or rigorous back to simple. For rigorous models, a traffic light shows the risk status for the exchanger. Click on the traffic Column 4: light to go directly to the EDR risks. Click on the heading of this column to view a summary of Operation Risk Status all exchanger risks.
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
Converting Models
The conversions supported in Activation are the same as those allowed in previous versions of Aspen Plus. The chart below in Figure 10 shows the possible conversions between simple unit operations and rigorous EDR models.
HeatX
AirCooled Plate
Click on the Convert button from either of these locations to begin model conversion. The form shown below will open.
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
2. Select a sizing method on the right. For Plate models, interactive sizing is not supported, only EDR file imports. 3. Click the Convert button to continue.
Figure 12: Steps to complete Model Conversion
Rigorous to Simple
You can access the form to convert rigorous models back to simple from the activated summary table. Click on a button in the 3rd column for an EDR model type (Figure 13).
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Jump Start: Activated Exchanger Design & Rating in Aspen Plus V8.4
When you click on this button, instructions for the particular model will appear. Read the steps to achieve the conversion. Then click on the Convert button (Figure 14) to go to the forms where those steps can be completed.
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113
Additional Resources
Public Website:
www.aspentech.com/products/activation
About AspenTech
AspenTech is a leading supplier of software that optimizes process manufacturingfor energy, chemicals, engineering and construction, and other industries that manufacture and produce products from a chemical process. With integrated aspenONE solutions, process manufacturers can implement best practices for optimizing their engineering, manufacturing, and supply chain operations. As a result, AspenTech customers are better able to increase capacity, improve margins, reduce costs, and become more energy efficient. To see how the worlds leading process manufacturers rely on AspenTech to achieve their operational excellence goals, visit www.aspentech.com.
Worldwide Headquarters
Aspen Technology, Inc. 200 Wheeler Road Burlington, MA 01803 United States phone: +17812216400 fax: +17812216410 info@aspentech.com
Regional Headquarters
Houston, TX | USA phone: +12815841000 So Paulo | Brazil phone: +551134436261 Reading | United Kingdom phone: +44(0)1189226400 Singapore | Republic of Singapore phone: +6563953900 Manama | Bahrain phone: +97317503000
2013 Aspen Technology, Inc. AspenTech, aspenONE, the Aspen leaf logo, the aspenONE logo, and OPTIMIZE are trademarks of Aspen Technology, Inc. All rights reserved. 11-4606-1113