Overview Features & Selection Guide Specifications & Wiring Terminal Configuration, Keypad & Parameter Navigation Program Parameter Descriptions Dimension DB Resistor, Options & Peripheral Devices 02 04 06 08 10 12 14
Overview
Standard features
kW / Voltage Ratings: 0.5 ~ 2HP, 200-230VAC, 1phase 0.5 ~ 5HP, 200-230VAC, 3phase 0.5 ~ 5HP, 380-460VAC, 3phase Enclosure: IP00 ~ IP20 Inverter Type: PWM with IGBT Control Method: Volts / Hertz with Space Vector Technology Built-in RS-485 Built-in ModBus-RTU Built-in PID control Removable keypad (Able to read & write parameter) 150% torque at 0.5Hz Trip-free operation algorithm 8 preset speeds 3 jump(skip) frequencies 3 Multifuctional inputs 1 Multifuctional output Analog output (0~12V) PNP and NPN dual directional signals Speed search 3 wire operation 1 to 10 kHz carrier frequency Built-in Braking transistor Manual/Auto torque boost
Compact iG5, is the best for a small and cost effective configuration.
Options
Cable for Remote Keypad Operations(2,3 and 5 meters) DIN rail base for easy installation
Application
Converting Fan Pump Food processing machine Electric shutter Dryer Running machine Overheat Commercial washing machine Grinder Textile machine Material handling machine Centrifuge Elevator door Tooling machine
02
Starvert iG5
Reduced size
Enhancing its performance the iG5 shows much smaller size compares to the previous model, the iG series. Maximum 50% of total volume has been reduced in iG5 in order to mount it easily on smaller control panel and DIN rail with less weight. It allows more cost effective panel construction and system design.
RS - 485 ModBus-RTU
TM
03
Stopped
CH1=2V DC 10:1 CH3=5V DC 10:1 CH4=2V DC 10:1 1s/div [1s/div] NORM:1kS/s
Trip
=Filter= =Offset= =Record Length= Main : 10k Zoom : 500 =Trigger= Mode : AUTO Type : EDGE CH1 Delay : 0.0ns Hold Off : MINIMUM =Filter= =Offset= =Record Length= Main : 10k Zoom : 500 =Trigger= Mode : AUTO Type : EDGE CH1 Delay : 0.0ns Hold Off : MINIMUM Smoothing : OFF Ch1 : 0.00V BW : FULL Ch2 : 0.00V CH3 : 0.00V CH4 : 0.00V Smoothing : OFF Ch1 : 0.00V BW : FULL Ch2 : 0.00V CH3 : 0.00V CH4 : 0.00V
Traditional curve
Optimum curve
LG Starvert drive
-1 -2 -4
04
Starvert iG5
1.2
2.2
1.7
0 ~ 400 Hz 3) 380 ~ 460V* 3 phase 380 ~ 460 V( 10%) 50 ~ 60 Hz ( 5%) 1.7 1.8 2.1 On board 20% (with optional external braking resistor : 100%, 150%) 15 seconds 0 ~ 30 % ED Forced air cooling IP00
2.2
2.2
*1) Indicates the maximum applicable capacity when using 4 pole LG standard motor. *2) Rated capacity ( 3*V*I) is based on 220V for 200V class and 440V for 400V class. *3) Maximum output voltage will not be greater than the input voltage. Output voltage less than the input voltage can be set.
Control method Frequency setting resolution Frequency accuracy Control V/F ratio Overload capacity Torque boost Operation method Frequency setting Start signal Input signal Multi-step Multi-step accel/decel time Emergency stop Jog Fault reset Output signal Operation status Fault output Indicator
V/F control Digital reference : 0.01 Hz (below 100 Hz), 0.1 Hz (over 100 Hz) Digital : 0.01% of max. output frequency Linear, Square pattern, User V/F 150 % of rated current for 1 min., 200% of rated current for 0.5 sec. (characteristic is inversely proportional to time) Manual torque boost (0 ~ 15 %), Auto torque boost Keypad / terminal / communication operation Analog : 0 ~ 10V / 4 ~ 20 mA Forward, Reverse Up to 8 speeds can be set (use multi-function terminal) 0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal), Accel/Decel pattern : linear pattern, U pattern, S pattern, Optimum, Minimum Interrupts the output of the drive Jog operation Resets fault when protective function is active Frequency level detection, Overload alarm, stalling, overvoltage, undervoltage, drive overheating, running, stop, constant speed, speed searching Contact output (30A,30C,30B) - AC250V 1A, DC30V 1A Choose 1 from output frequency, output current, output voltage, DC voltage (Output pulse: 500Hz, Output voltage: 0 ~ 10V) DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention, auto restart, PID control Digital : keypad Analog reference : 0.03 Hz / 50 Hz Analog : 0.1% of max. output frequency
Operation
Operation function Drive trip Protective function Display Keypad Inverter alarm Momentary power loss Operation information Trip information Ambient temperature Storage temperature Environment Ambient humidity Altitude . Vibration Application site
Overvoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss, input/output mis-wiring, overload protection, communication error, loss of speed command, hardware fault. Stall prevention, overload alarm Less than 15 msec : continuous operation, more than 15 msec : auto restart possible Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltage Indicates the fault when the protection function activates, memorizes up to 5 faults -10 C ~ 40 C -20 C ~ 65 C 90 % RH max.(Non condensing) Below 1,000 m below 5.9m/sec2(=0.6g) No corrosive gas, combustible gas, oil mist, or dust
05
Wiring
DB Resistor*2
B1
B2 U V W
MOTOR
Shield MO Power supply for VR speed signal: +12V, 100mA V1 Speed signal input: 0 ~10V I Speed signal input: 4 ~ 20mA(250ohm) CM Common for VR, V1, I S+ SModBus-RTU RS-485 Communication port MG Multi-function output Iess than DC24V, 50mA Factory setting:`RUN`
Note) " " display main circuit terminals, " " display control circuit terminals. 1. Analog speed command can be set by Voltage, Current and both of them. 2. DB resistor is optional.
06
Starvert iG5
External additional dynamic braking resistor connection terminals. Chassis ground (The gound terminal("G") may be located on heat sink instead of terminal strip depend on the model name)
Keypad
Class Display FUNC UP KEY DOWN RUN STOP/RESET REV LED FWD SET RUN Name Program key Up key Down key Run key STOP/RESET key Reverse run Forward run Setting Operating Description Press to change the parameter setting. Press to move through codes or to increase the parameter values. Press to move through codes or to decrease the parameter values. Use to operate the drive Press to stop during operation. Press to reset when a fault has occurred. During reverse run. During forward run. When the user is setting the parameters using the FUNC key When in constant speed and blinks when accelerating or decelerating.
Parameter group
Output signal
Input signal
Group name
Description Basic parameters of Command frequency, Accel/Decel time etc. Basic parameters of Max. Frequency, Torque boost etc. Application parameters of Frequency jump, Frequency limit etc. Multifunction terminal setting and Sequence operation parameters
07
Parameter navigation
1. Drive Group
SET RUN FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
2. Function Group
SET RUN
3. I/O Group
FWD REV SET RUN
FU I F O
I0 I 0
FWD REV
FUNC
SET RUN FWD REV
FUNC
SET RUN FWD REV
SET RUN
FWD REV
SET RUN
FWD REV
FUNC
SET RUN
FUNC
FU I
FWD REV
SET RUN
I0
FWD REV
08
DRV-04
No
DRV-05 DRV-06 DRV-07 DRV-08 DRV-09 DRV-10 DRV-11 DRV-12 DRV-13 DRV-20 DRV-21 DRV-22
Step Frequency 1 Step Frequency 2 Step Frequency 3 Output Current Motor Speed DC link Voltage User Display selection Fault Display Motor Direction set FU1 Group selection FU2 Group selection I/O Group selection
10.00 [Hz] 20.00 [Hz] 30.00 [Hz] - [A] - [rpm] - [V] nOn F
Yes
Yes
2. Function Group1[FU1]
FU1-00 FU1-03 FU1-05 Jump to desired code # Run Prevention F0 F3 F5 1 to 99 0 (None) 1 (Forward Prev) 2 (Reverse Prev) 0 (Linear) 1 (S-curve) 2 (U-curve) 3 (Minimum) 4 (Optimum) 0 (Linear) 1 (S-curve) 2 (U-curve) 3 (Minimum) 4 (Optimum) 0 (Decel) 1 (DC-brake) 2 (Free-run) FU1-22 to 50 [Hz] 0 to 60 [sec] 0 to 200 [%] 0 to 60 [sec] 0 to 200 [%] 0 to 60 [sec] 40 to 400 [Hz] 30 to FU1-20 0.1 to 10 [Hz] 0 (No) 1 (Yes) FU1-22 to FU1-25 FU1-24 to FU1-20 0 (Manual) 1 (Auto) 0 to 15 [%] 0 to 15 [%] 0 (Linear) 1 (Square) 2 (User V/F) 0 to FU1-32 0 to 100 [%] FU1-30 to FU1-20 0 to 100 [%] FU1-32 to FU1-20 0 to 100 [%] FU1-34 to FU1-20 0 to 100 [%] 40 to 110 [%] 0 to 30 [%] 0 (No) 1 (Yes) FU1-52 to 150 [%] 50 to FU1-51 0 (Self-cool) 1 (Forced-cool) 1 3 0 Yes No
Acceleration Pattern
No
FU1-06
Deceleration Pattern
F6
No
FU1-07 FU1-08 FU1-09 FU1-10 FU1-11 FU1-12 FU1-13 FU1-20 FU1-21 FU1-22 FU1-23 FU1-24 FU1-25 FU1-26 FU1-27 FU1-28 FU1-29 FU1-30 FU1-31 FU1-32 FU1-33 FU1-34 FU1-35 FU1-36 FU1-37 FU1-38 FU1-39 FU1-50 FU1-51 FU1-52 FU1-53
Stop Mode
F7 F8 F9 FI0 FI I FI2 FI3 F20 F2 I F22 F23 F24 F25 F26 F27 F28 F29 F30 F3 I F32 F33 F34 F35 F36 F37 F38 F39 F50 F5 I F52 F53
No
DC Injection Braking Frequency DC Injection Braking On-delay Time DC Injection Braking Voltage Starting DC Injection Braking Time Starting DC Injection Braking Voltage Starting DC Injection Braking Time Maximum Frequency Base Frequency Starting Frequency Frequency Limit selection Low Limit Frequency High Limit Frequency Manual/Auto Torque Boost selection Torque Boost in Forward Direction Torque Boost in Reverse Direction Volts/Hz Pattern
0.01 0.01 1 0.1 1 0.1 0.01 0.01 0.01 0.01 0.01 0.1 0.1 -
5.00 [Hz] 0.5 [sec] 50 [%] 1.0 [sec] 50 [%] 0.0 [sec] 60.00 [Hz]* 60.00 [Hz]* 0.50 [Hz]
No No No No No No No No No No No No No No No No
User V/F - Frequency 1 User V/F - Voltage 1 User V/F - Frequency 2 User V/F - Voltage 2 User V/F - Frequency 3 User V/F - Voltage 3 User V/F - Frequency 4 User V/F - Voltage 4 Output Voltage Adjustment Energy Save Level F39 Electronic Thermal selection Electronic Thermal Level for 1 minute Electronic Thermal Level for continuous Electronic Thermal Characteristic selection (Motor type)
15.00 [Hz]* 25 [%] 30.00 [Hz]* 50 [%] 45.00 [Hz]* 75 [%] 60.00 [Hz]* 100 [%] 100[%] 0 [%] 0 150 [%] 150 [%] 0
09
FU1-60 FU1-99
F60
1 -
150 [%] -
No -
Power ON Start selection Restart after Fault Reset Speed Search selection
H20 H2 I H22
FU2-23 FU2-24 FU2-25 FU2-26 FU2-27 FU2-30 FU2-31 FU2-32 FU2-33 FU2-34 FU2-36 FU2-37 FU2-39 FU2-40 FU2-50 FU2-51 FU2-52 FU2-53 FU2-54 FU2-70 FU2-71 FU2-72
Current Limit Level during Speed Search P Gain during Speed Search I Gain during speed search Number of Auto Restart Attempt Delay Time before Auto Restart Rated Motor selection Number of Motor Poles Rated Motor Slip Rated Motor Current in RMS No Load Motor Current in RMS Motor Efficiency Load Inertia Carrier Frequency Control Mode selection
H23 H24 H25 H26 H27 H30 H3 I H32 H33 H34 H36 H37 H39 H40 H50 H5 I H52 H53 H54 H70 H7 I H72
PID Feedback Signal selection P Gain for PID Control I Gain for PID Control D Gain for PID Control Limit Frequency for PID Control Reference Frequency for Accel and Decel Accel/Decel Time Scale
Power On Display
0 (No) 1 (Yes) 0 to FU1-20 0 to 10 [sec] 0 (No) 1 (Yes) FU1-22 to FU2-12 FU1-11 to FU2-20 FU1-22 to FU2-14 FU2-13 to FU1-20 FU1-22 to FU2-16 FU2-15 to FU1-20 00 - 11 (bit set) Bit 0: Output phase loss protection Bit 1: Intput phase loss protection 0 (No) 1 (Yes) 0 (No) 1 (Yes) 0000 - 1111 (bit set) Bit 0: during Accel. Bit 1: after fault reset Bit 2: after instant power failure restart Bit 3: when FU2-20 is set to 1 (Yes). 80 to 200 [%] 0 to 9999 0 to 9999 0 to 10 0 to 60 [sec] 0.4 (0.37kW) 0.8 (0.75kW) 1.5 (1.5kW) 2.2 (2.2kW) 2 to 12 0 to 10 [Hz] 0.1 to 99.9 [A] 0.1 to 99.9 [A] 50 to 100 [%] 0 to 2 1 to 10 [kHz] 0 (V/F) 1 (Slip Compen) 2 (PID) 0 (I) 1 (V1) 0 to 9999 0 to 9999 0 to 9999 0 to FU1-20 0 (Max Freq) 1 (Delta Freq) 0 (0.01 sec) 1 (0.1 sec) 2 (1 sec) 0 (Cmd. Freq) 1 (Acc. Time) 2 (Dec. Time) 3 (Drv mode) 4 (Freq mode) 5 (Step Freq 1) 6 (Step Freq 2) 7 (Step Freq 3) 8 (Current) 9 (Speed) 10(DC link Vtg) 11 (User disp) 12 (Fault Display) 13 (Motor direction)
0 0 0000
Yes Yes No
1 1 1 1 0.1 1 0.01 1 1 1 1 1 -
0 3 kHz 0
1 1 1 0.01 -
Yes
10
Starvert iG5
Factory Default 0 Adjustable during run Yes
Code FU2-73 FU2-74 FU2-75 FU2-76 FU2-79 FU2-81 FU2-82 FU2-83 FU2-84 FU2-85 FU2-86 FU2-87 FU2-88 FU2-89 FU2-90 FU2-91 FU2-92 FU2-93
Keypad Display H73 H74 H75 H76 H79 H8 I H82 H83 H84 H85 H86 H87 H88 H89 H90 H9 I H92 H93
Setting Range 0 (Voltage) 1 (Watt) 2 (Torque) 1 to 1000 [%] 0 [None] 1 [None] 2 (Ext.DB-R) 0 to 30 [%] 0 to 6000 [sec] 0 to 6000 [sec] 30 to FU1-20 0 (Linear) 1 (Square) 2 (User V/F) 0 to 15 [%] 0 to 15 [%] 30 to 150 [%] FU2-89 to 150 [%] 50 to FU2-88(maximum 150%) 0.1 to 99.9 [A] 0 (No) 1 (Yes) 0 (No) 1 (Yes) 0 (No) 1 (All Groups) 2 (DRV) 3 (FU1) 4 (FU2) 5 (I/O) 0 to 255
Units -
Gain for Motor Speed Display DB(Dynamic Braking)Resistor Mode selection Duty of Dynamic Braking Resistor Software Version 2nd Acceleration Time 2nd Deceleration Time 2nd Base Frequency 2nd V/F Pattern
1 -
100 [%] 0
Yes Yes
2nd Forward Torque Boost 2nd Reverse Torque Boost 2nd Stall Prevention Level 2nd Electronic Thermal Level for 1 minute 2nd Electronic Thermal Level for continuous 2nd Rated Motor Current Read Parameters into Keypad from Inverter Write Parameters to Inverter from Keypad Initialize Parameter
5.0 [%] 5.0 [%] 150 [%] 150 [%] 100 [%] 1.8 [A] 0 0 0
No No No Yes Yes No No No No
FU2-94 FU2-99
H94
1 -
0 1
Yes Yes
Multi-function Input Terminal 'P1' define 8,9, 15, 20, 21, 22, 23, 24, 25, 26(-Reserved-)
I I2
No
11
I/O-13 I/O-14 I/O-15 I/O-16 I/O-17 I/O-20 I/O-21 I/O-22 I/O-23 I/O-24 I/O-25 I/O-26 I/O-27 I/O-28 I/O-29 I/O-30
Multi-function Input Terminal 'P2' define Multi-function Input Terminal 'P3' define Terminal Input Status Terminal Output Status Filtering Time Constant for Multi-function Input Terminals Jog Frequency setting Step Frequency 4 Step Frequency 5 Step Frequency 6 Step Frequency 7 Acceleration Time 1 for Step Frequency Deceleration Time 1 for Step Frequency Acceleration Time 2 Deceleration Time 2 Acceleration Time 3 Deceleration Time 3
I I I I I I I I I I I I I I I I
I3 I4 I5 I6 I7 20 2I 22 23 24 25 26 27 28 29 30
1 0.01 0.01 0.01 0.01 0.1 0.1 0.1 0.1 0.1 0.1 0.1
1 2 15 10.00 [Hz] 40.00 [Hz] 50.00 [Hz] 40.00 [Hz] 30.00 [Hz] 20.0 [sec] 20.0 [sec] 30.0 [sec] 30.0 [sec] 40.0 [sec] 40.0 [sec]
No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Dimension
Code I/O-31 I/O-32 I/O-33 I/O-34 I/O-35 I/O-36 I/O-37 I/O-38 I/O-40 Description Acceleration Time 4 Deceleration Time 4 Acceleration Time 5 Deceleration Time 5 Acceleration Time 6 Deceleration Time 6 Acceleration Time 7 Deceleration Time 7 FM (Frequency Meter) Output selection Keypad Display I I I I I I I I I 3I 32 33 34 35 36 37 38 40 Setting Range 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 (Frequency) 1 (Current) 2 (Voltage) 3 (DC link Vtg) 10 to 200 [%] 0 to FU1-20 0 to FU1-20 0 (FDT-1) 1 (FDT-2) 2 (FDT-3) 3 (FDT-4) 4 (FDT-5) 5 (IOL) 6 (IOL) 7 (Stall) 8 (OV) 9 (LV) 10 (OH) 11 (Lost Command) 12 (Run) 13 (Stop) 14 (Steady) 17 (Search) 000 - 111 (bit set) Bit 0: LV Bit 1: All Trip Bit 2: Auto retry 1 to 32 0 (1200 bps) 1 (2400 bps) 2 (4800 bps) 3 (9600 bps) 4 (19200 bps) 0 (None) 1 (FreeRun) 2 (Stop) 0.1 to 120 [sec] 0 (LG- BUS) 1~6(ModbusASCII) 7~9 (Modbus-RTU) Units 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Factory Default 50.0 [sec] 50.0 [sec] 40.0 [sec] 40.0 [sec] 30.0 [sec] 30.0 [sec] 20.0 [sec] 20.0 [sec] 0 Adjustable during run Yes Yes Yes Yes Yes Yes Yes Yes Yes
FM Output Adjustment Frequency Detection Level Frquency Detection Bandwidth Multi-function Output define (MO)15, 16, 18, 19, 20(-Reserved-)
I I I I
4I 42 43 44
1 0.01 0.01 -
I 45 I 46 I 47
010
Yes
1 -
1 3
Yes Yes
I 48 I 49 I 50
Yes
0.1
1.0 [sec] 7
Yes Yes
Return Code
Yes
Note: Parameters that are set by bit are ON (1) when the upper LED is lit. (F59, H19, H22, I15, I16, I45 are the parameters that are set by bit.) Note: *marked default value changes depend on the main frequency setting in factory(50 / 60Hz)
Dimension : mm(inch)
4.5
iG5
VARIABLE FREQUENCY DRIVER
00.00
SOURCE AC200-230V 50/60Hz OUTPUT CAPACITY 1.5kVA CURRENT 5A FRCQUENCY 0.2-400Hz
SV015IG5-2
CAUTION
Read the manual and follow the safety instruction before installation or operation Do not the power supply to the drive output terminal (U, V, W) Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge. `Risk of Electric Shock`-more than one disconnect switch is required to de energize the equipment before servicing.
4.5 W2 W1
4.5
H2
Inverter SV004iG5-1 SV004iG5-2 SV008iG5-1 SV008iG5-2 SV015iG5-1 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4
W1 100(3.94) 100(3.94) 130(5.12) 100(3.94) 150(5.90) 130(5.12) 150(5.90) 150(5.90) 150(5.90) 130(5.12) 130(5.12) 130(5.12) 150(5.90) 150(5.90) 150(5.90)
W2 88(3.46) 88(3.46) 118(4.65) 88(3.46) 138(5.43) 118(4.65) 138(5.43) 138(5.43) 138(5.43) 118(4.65) 118(4.65) 118(4.65) 138(5.43) 138(5.43) 138(5.43)
H1 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04)
H2 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63)
D1 130.9(5.15) 130.9(5.15) 150.9(5.94) 130.9(5.15) 155(6.10) 150.9(5.94) 155(6.10) 155(6.10) 155(6.10) 150.9(5.94) 150.9(5.94) 150.9(5.94) 155(6.10) 155(6.10) 155(6.10)
D1
12
Starvert iG5
Options
Option DIN Rail base Remote keypad mounting fixture and cable Description Din rail mounting plate 2 meter, 3 meter and 5 meter cable and mounting fixture.
Peripheral devices
Drive Models SV004iG5-1 SV008iG5-1 SV015iG5-1 SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 kW 0.37 0.75 1.5 0.37 0.75 1.5 2.2 3.7 4 0.37 0.75 1.5 2.2 3.7 4 MCCB, ELB ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 Magnetic Contactor SMC-10P SMC-10P SMC-10P SMC-10P SMC-10P SMC-10P SMC-15P SMC-20P SMC-20P SMC-10P SMC-10P SMC-10P SMC-20P SMC-20P SMC-20P R,S,T 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 3.5(12) 3.5(12) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) Wire, mm2(AWG) U,V,W Ground 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 3.5(12) 3.5(12) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) AC Input 10A 10A 10A 10A 10A 15A 25A 40A 40A 6A 6A 10A 10A 20A 20A AC Reactor 2.13mH, 5.7A 2.13mH, 5.7A 2.13mH, 5.7A 2.13mH, 5.7A 2.13mH, 5.7A 1.20mH, 10A 0.88mH, 14A 0.56mH, 20A 0.56mH, 20A 8.63mH, 2.8A 8.63mH, 2.8A 4.81mH, 4.8A 3.23mH, 7.5A 2.34mH, 10A 2.34mH, 10A DC Reactor 7.00mH, 5.4A 7.00mH, 5.4A 7.00mH, 5.4A 7.00mH, 5.4A 7.00mH, 5.4A 4.05mH, 9.2A 2.92mH, 13A 1.98mH, 19A 1.98mH, 19A 28.62mH, 2.7A 28.62mH, 2.7A 16.14mH, 4.6A 11.66mH, 7.1A 7.83mH, 10A 7.83mH, 10A
13
RFI Filters
IG5 Series Drive Models SINGLE PHASE SV004iG5-1 SV008iG5-1 SV015iG5-1 THREE PHASE SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 IG5 Series Drive Models SINGLE PHASE SV004iG5-1 SV008iG5-1 SV015iG5-1 THREE PHASE SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 Power Code Current Power Code Current Footprint Filter Tension Voltage (max.) 250VA 250VA 250VA (max.) 250VA 250VA 250VA Leakage Current 3.5A 3.5A 3.5A 0.3A 18A 0.3A 18A 0.3A 18A Dimensions LWH 173.5 X 103.5 X 40 173.5 X 133.5 X 40 173.5 X 153.5 X 40 173.5 X 103.5 X 40 173.5 X 133.5 X 40 173.5 X 153.5 X 40 Mounting YX 159.5 X 80 159.5 X 110 159.5 X 130 159.5 X 80 159.5 X 110 159.5 X 130 Weight Mount Output Chokes FS-1 FS-1 FS-2 FS-1 FS-2 FS-2
0.4kW 0.8kW 1.5kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW
M4 M4 M4 M4 M4 M4
FFG5-T006-1 FFG5-T011-1
6A
380VAC
0.5A 27A
173.5 X 133.5 X 40
159.5 X 110
M4
FS-1
11A
380VAC
0.5A 27A
173.5 X 133.5 X 40
159.5 X 130
M4
FS-2
Standard Filter Tension Voltage (max.) 0.4kW 0.8kW 1.5kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW FEG5-T010-(X) FEG5-T015-(X) FEG5-T006-(X) FEG5-T012-(X) FEG5-T020-(X) 10A 15A 6A 12A 20A 250VA 250VA (max.) 250VA 250VA 250VA 3.5A 3.5A 0.3A 18A 0.3A 18A 0.3A 18A 150.5 X 55 X 45 150.5 X 55 X 45 250 X 110 X 60 250 X 110 X 60 270 X 140 X 60 140 X 45 140 X 45 238 X 76 238 X 76 258 X 106 ----------FS-1 FS-2 FS-2 FS-2 FS-2 Leakage Current Dimensions LWH Mounting YX Weight Mount Output Chokes
FEG5-T006-(X) FEG5-T012-(X)
6A
380VAC
0.5A 27A
250 X 110 X 60
238 X 76
---
FS-2
12A
380VAC
0.5A 27A
250 X 110 X 60
238 X 76
---
FS-2
(X) (1) Industrial environment EN 50081-1 (A class) (2) Domestic and industrial environment EN 50081-1 (B class)
FF Series (Footprint)
H
FE Series (Standard)
H
Y
Y
X W
RED
CARGA
Type
W X
D 21 28.5 48 58
H 46 62 110 170
X 70 90 125 x 30 180 x 45
O 5 5 5 5
INVERTER
FF Series (Footprint)
FILTER
SHIELDED CABLE
MOTOR
FE Series (Standard)
INVERTER FILTER
SHIELDED CABLE
MOTOR