Professional Documents
Culture Documents
C100 Catalog
C100 Catalog
Compact Drive
C100
0.1~2.2kW 1phase 200V
0.1~3.7kW 3phase 200V
0.4~7.5kW 3phase 400V
C O N T E N T S
Compact
Convenient
Model & Type / Basic Specifications
Control
Connection Diagram
Terminal Function
Control Circuit Terminal
Keypad Usage & Function
Moving to Other Parameter Groups & Codes
Braking Resistors and Peripheral Devices
Dimensions
04
06
08
10
11
12
13
14
15
17
18
Convenient
Compact
02_03
Features
Size Reduction
Standard 200V 1.5kW
COMPACT
No Need for 'Big Drives'.
Compact but Optimized LSLV-C100
Will do the Job
04_05
Side-by-Side Installation
The control can be significantly reduced thanks to C100's 'side-by-side' installation.
iG5A(500mm)
C100(364mm)
30mm
50mm
50mm
50mm
30mm
50mm
2mm
2mm
Size Reduction
Input Voltage
DC-ink Voltage
Operating
Frequency
Output Current
/SAT
A
SB
Safety Stop
Relay
PWM
/SAT
B
/OC2
Gate
Block
145mm
33%
Size Reduction
Standard 200V 1.5kW
CPU
PWM
Fault
SA
100 128
IM
Features
CONVENIENT
Simple Operation and Easy Maintenance
Features Enhance Customers Convenience.
User Convenience by
Simple Operation
Integrated Potentiometer
Provides external potentiometer for easier
frequency control
Addtional 0~5V analog input for freqeuncy
control
Dual Rating
Designed to Select Between
Heavy and Light Load
Overload
Withstand
Converter
06_07
Power
1Phase 200V
3Phase 200V
3Phase 400V
0.1 kW
LSLV0001C100-1
LSLV0001C100-2
0.2 kW
LSLV0002C100-1
LSLV0002C100-2
0.4 kW
LSLV0004C100-1
LSLV0004C100-2
LSLV0004C100-4
0.8 kW
LSLV0008C100-1
LSLV0008C100-2
LSLV0008C100-4
1.5 kW
LSLV0015C100-1
LSLV0015C100-2
LSLV0015C100-4
2.2 kW
LSLV0022C100-1
LSLV0022C100-2
LSLV0022C100-4
3.7 kW
LSLV0037C100-2
LSLV0037C100-4
5.5 kW
LSLV0055C100-2
LSLV0055C100-4
7.5 kW
LSLV0075C100-2
LSLV0075C100-4
0001
0002
0004
[HP]
1/8
1/4
[kW]
0.1
0.2
0.3
Rated Current[A]3)
0.8
2)
Output Ratings
0008
0015
0022
1/2
0.4
0.75
1.5
2.2
0.5
1.0
1.9
3.0
4.2
1.4
2.5
5.0
8.0
11
14.1
24
400 [Hz]4)
Rated Current[A]
1.4
2.8
11
50 ~ 60 [Hz] (5%)
Rated Frequency
Cooling Type
5.5
Natural Cooling
0.55
0.55
Forced Cooling
0.8
1.22
1.42
1.97
08_09
Rated Current[A] 3)
0001
0002
0004
0008
0015
0022
0037
0055
0075
[HP]
1/8
1/4
1/2
7.5
10
[kW]
0.1
0.2
0.4
0.75
1.5
2.2
3.7
5.5
7.5
[HP]
1/4
1/2
1.5
5.4
10
15
[kW]
0.2
0.4
0.75
1.1
2.2
3.0
4.0
7.5
11.0
HD
0.3
0.5
1.0
1.9
3.0
4.2
6.1
9.1
12.2
ND
0.4
0.7
1.3
2.4
3.8
5.2
7.6
12.1
16.3
HD
0.7
1.5
2.0
5.8
7.5
11.0
18.9
22.1
28.6
ND
1.1
1.8
3.1
6.3
10.0
12.0
18.0
30.0
40.0
400 [Hz]4)
0.7
1.5
2.0
5.8
7.5
11.0
18.9
22.1
28.6
ND
1.1
1.9
3.9
7.3
10.8
13.9
24
28.6
41.2
3.3
3.3
Rated Frequency
50 ~ 60 [Hz] (5%)
Natural Cooling
Cooling Type
0.55
0.55
Forced Cooling
0.8
0.8
1.22
1.42
1.97
Input Ratings
Rated Current[A] 3)
0004
0008
0015
0022
0037
0055
0075
[HP]
1/2
1.0
2.0
3.0
5.0
7.5
10.0
[kW]
0.4
0.75
1.5
2.2
3.7
5.5
7.5
[HP]
1.5
5.4
10
15
[kW]
0.75
1.1
2.2
3.0
4.0
7.5
11.0
HD
1.0
1.9
3.0
4.2
6.1
9.1
12.2
ND
1.2
2.4
3.8
5.2
7.6
12.1
16.3
HD
1.25
2.5
4.0
5.5
8.0
12.0
16.0
ND
2.0
3.1
5.1
6.9
10.0
16.0
23.0
400 [Hz]4)
1.8
3.2
4.4
10.4
11.0
14.4
ND
2.1
4.3
5.9
8.1
14
14.7
21.9
3.3
3.4
Rated Frequency
Cooling Type
Weight of Drive [kg]
50 ~ 60 [Hz] (5%)
Natural Cooling
0.8
Forced Cooling
0.8
1.22
1.42
Note 1) Indicates the maximum applicable motor capacity when using a 4-pole standard motor of HIGEN.
Note 2) Rated capacity is based on 220V for 200V class and 440V for 400V class.
Note 3) When Carrier frequency setting (H39) is above 6kHz.
Note 4) The max. frequency setting range can be 120Hz when H40 is set to 3(Sensorless vector control)
Note 5) The maximum output voltage cannot be higher than the input voltage and it can be programmable below input voltage.
1.97
Controller
Control
Control Type
Frequency Precision
V/F Pattern
Overload Capacity
Torque Compensation
Dynamic Torque 20%
Braking
20%1)
Time/%ED
Operation
Operation Mode
Frequency Setting
Operational Functions
P1 ~ P5
Input
Multi-function Terminals
(5 pcs) P1 ~ P5
Multi-function Relay
Analog Output
0 ~ 10Vdc (less than 10mA): Choose among Output Freq, Output Current, Output Voltage,
DC link selectable.
Output
Protective Function
Faults
Over voltage, low voltage, over current, short circuit, ground current detection, drive overheat,
motor overheat, input and output phase loss, overload protection, communication error,
loss of frequency command, hardware fault, cool fan trip, brake error.
Alarm
Note 1) the rated input voltage is 220V for 200V class, 440V for 400V class, and the rated input is subject to HD.
Storage Temperature
-20C ~ 65C
Application Humidity
Altitude/Vibration
Atmospheric Pressure
70~106 kPa
Installation Environment
There shall not be corrosive air, combustible gas, oil mist, dust and so on.
Connection Diagram
10_11
Terminal Function
R.S.T Size
U,V,W Size
Ground Size
Terminal Screw
Size
Screw Torque
(kgf.cm)/Ib-in
12
M3.5
10/8.7
3.5
12
M3.5
10/8.7
14
3.5
12
M3.5
10/8.7
14
3.5
12
M3.5
10/8.7
14
14
3.5
12
M3.5
10/8.7
3.5
12
3.5
12
3.5
12
M4
15/13
LSLV0015C100-2
14
14
3.5
12
M3.5
10/8.7
LSLV0022C100-2
14
14
3.5
12
M3.5
10/8.7
LSLV0037C100-2
3.5
12
3.5
12
3.5
12
M4
15/13
LSLV0055C100-2
10
10
5.5
10
M4
15/13
LSLV0075C100-2
10
10
5.5
10
M4
15/13
LSLV0004C100-4
14
14
3.5
12
M3.5
10/8.7
LSLV0008C100-4
14
14
3.5
12
M3.5
10/8.7
LSLV0015C100-4
14
14
3.5
12
M3.5
10/8.7
LSLV0022C100-4
14
14
3.5
12
M3.5
10/8.7
LSLV0037C100-4
3.5
12
3.5
12
3.5
12
M4
15/13
LSLV0055C100-4
3.5
12
3.5
12
3.5
12
M4
15/13
LSLV0075C100-4
3.5
12
3.5
12
3.5
12
M4
15/13
mm 2
AWG
mm 2
AWG
mm 2
AWG
LSLV0001C100-1
14
14
3.5
LSLV0002C100-1
14
14
LSLV0004C100-1
14
LSLV0008C100-1
14
LSLV0015C100-1
LSLV0022C100-1
12_13
Wire Size(mm 2)
T/M
Terminal Description
Single Wire Stranded
Screw Torque
[Nm]
Size
1.0
1.5
M2.6
0.4
CM
Common terminal
1.0
1.5
M2.6
0.4
VR
1.0
1.5
M2.6
0.4
AI
1.0
1.5
M2.6
0.4
AM
1.0
1.5
M2.6
0.4
S+
1.0
1.5
M2.6
0.4
S-
1.0
1.5
M2.6
0.4
24
1.0
1.5
M2.6
0.4
3A
1.0
1.5
M2.6
0.4
3B
1.0
1.5
M2.6
0.4
3C
1.0
1.5
M2.6
0.4
SA
1.0
1.5
M2.6
0.4
SB
1.0
1.5
M2.6
0.4
SC
1.0
1.5
M2.6
0.4
P1~P5
Specification
Note 1) Tie the control wires mote than 15cm away from the control terminals. Otherwise, it interferes front cover reinstallation.
Note 2) Use Copper wires rated 600V, 75C and higher.
Note 3) Use the recommended tightening torque when securing terminal screws.
Alpha-numeric Table
Display
Key
Description
RUN
Run command
STOP/RESET
Up
Down
Left
Used to switch parameter groups or move the cursor to the left when the
parameters are written.
Right
Used to switch parameter groups or move the cursor to the right when the
parameters are written.
ENT
Volume
FWD
Forward
REV
Reverse
RUN
Running
SET
Setting
Current Values
7-segment
14_15
Drive Group
Set Basic parameters necessary for drive operation, including target frequency, Accel/Decel time and so on.
Function Group 1
Set basic function parameters, such as adjustment of input frequency, voltage and so on.
Function Group 2
Set advanced function parameters, for example, set application functions such as PID operation, second motor
operation and so on.
I/O (input/output)
Terminal Function
Group
Note 1) Target frequency can be set at 0.0 (the 1st code of drive group). Even though the preset value is 0.0 while leaving factory, after setting of the target frequency,
the changed frequency value will be displayed.
The 1st code of the parameter group is displayed when the Power is applied
Press the Up () key.
The digit 5 is active, and then the parameter value can be changed.
Press the Up () key.
Note 1) When the parameter value is changed, the blinking cursor means if any changed value is required,
then Press the ENT key to complete the input of parameter change. Press any key of ()()()() if any parameter change is cancelled.
16_17
Braking Resistors
Supply Voltage
200V
400V
Inv[kW]
100% Braking
150% Braking
Resistance[W]
P*) [W]
Resistance[W]
P*) [W]
0.1
1200
20
1000
20
0.2
700
25
500
35
0.4
400
50
300
100
0.75
200
100
150
150
1.5
100
200
60
300
2.2
60
300
50
400
3.7
40
500
33
600
5.5
30
700
20
800
7.5
20
1000
15
1200
0.4
1800
50
1200
100
0.75
900
100
600
150
1.5
450
200
300
300
2.2
300
300
200
400
3.7
200
500
130
600
5.5
120
700
85
1000
7.5
90
1000
60
1200
Peripheral Devices
Input Voltage
1 Phase 200V
3 Phase 200V
3 Phase 400V
Drive Model
ELCB
MC
LSLV0001C100-1
EBS33c
MC-9a/9b
LSLV0002C100-1
EBS33c
MC-9a/9b
LSLV0004C100-1
EBS33c
MC-9a/9b
LSLV0008C100-1
EBS33c
MC-9a/9b
LSLV0015C100-1
EBS33c
MC-12a/12b
LSLV0022C100-1
EBS33c
MC-18b
LSLV0001C100-2
EBS33c
MC-9a/9b
LSLV0002C100-2
EBS33c
MC-9a/9b
LSLV0004C100-2
EBS33c
MC-9a/9b
LSLV0008C100-2
EBS33c
MC-9a/9b
LSLV0015C100-2
EBS33c
MC-12a/12b
LSLV0022C100-2
EBS33c
MC-18b
LSLV0037C100-2
EBS33c
MC-32a
LSLV0055C100-2
EBS53c
MC-40a
LSLV0075C100-2
EBS53c
MC-50a
LSLV0004C100-4
EBS53c
MC-9a/9b
LSLV0008C100-4
EBS53c
MC-9a/9b
LSLV0015C100-4
EBS53c
MC-9a/9b
LSLV0022C100-4
EBS53c
MC-12a/12b
LSLV0037C100-4
EBS53c
MC-18b
LSLV0055C100-4
EBS53c
MC-32a
LSLV0075C100-4
EBS53c
MC-32a
Dimensions
A
A
W1
W
68
68
68
68
W1
63.5
63.5
63.5
63.5
H
128
128
128
128
H1
124.5
124.5
124.5
124.5
D
93
93
93
93
4.2
4.2
4.2
4.2
A
4.5
4.5
4.5
4.5
B
4.2
4.2
4.2
4.2
kg
0.55
0.55
0.55
0.55
A
A
W1
Drive Volume
LSLV0004C100-1
LSLV0004C100-2
LSLV0008C100-2
LSLV0004C100-4
LSLV0008C100-4
W
68
68
68
68
68
W1
63.5
63.5
63.5
63.5
63.5
H
128
128
128
128
128
H1
124.5
124.5
124.5
124.5
124.5
D
128
128
128
128
128
4.2
4.2
4.2
4.2
4.2
A
4.5
4.5
4.5
4.5
4.5
B
4.2
4.2
4.2
4.2
4.2
H1
120
120
120
D
130
130
130
4.5
4.5
4.5
A
4.5
4.5
4.5
B
4.5
4.5
4.5
kg
0.8
0.8
0.8
0.8
0.8
W
W1
H1
W
100
100
100
W1
91
91
91
H
128
128
128
kg
1.22
1.22
1.22
18_19
W
W1
H1
W1
91
91
91
4.5
4.5
4.5
A
4.5
4.5
4.5
B
4.5
4.5
4.5
D
145
145
145
4.5
4.5
4.5
A
4
4
4
B
4.5
4.5
4.5
D
141
141
141
141
5
5
5
5
A
10.5
10.5
10.5
10.5
B
5
5
5
5
H
128
128
128
H1
120
120
120
D
145
145
145
H
128
128
128
H1
120
120
120
kg
1.42
1.42
1.42
Drive Volume
LSLV0015C100-1
LSLV0022C100-2
LSLV0022C100-4
H1
W
W1
W
140
140
140
W1
132
132
132
kg
1.97
1.97
1.97
H1
W1
W
0055C100-4 / 0075C100-4
Drive Volume
LSLV0055C100-2
LSLV0075C100-2
LSLV0055C100-4
LSLV0075C100-4
W
160
160
160
160
W1
137
137
137
137
H
232
232
232
232
H1
216.5
216.5
216.5
216.5
kg
3.3
3.3
3.3
3.4
For your safety, please read user's manual thoroughly before operating.
Contact the nearest authorized service facility for examination, repair, or adjustment.
Please contact qualified service technician when you need maintenance.
Do not disassemble or repair by yourself !
Safety Instructions
Any maintenance and inspection shall be performed by the personnel having expertise concerned.
Overseas Branches
HEAD OFFICE
LS Tower, 127, LS-ro, Dongan-gu, Anyang-si, Gyeonggi-Do, 431-848, Korea
Overseas Subsidiaries
LSIS(Shanghai) Co., Ltd. /CHINA
32nd Floor, International Corporate City, No.3000 NorthZhongshan Road,
Putuo District, Shanghai, China, 200063
Tel : 86-21-5237-9977(609) Fax : 86-21-5237-7189
LSIS(Wuxi) Co., Ltd./CHINA
102-A, National High & New Tech Industrial Development Area, Wuxi, Jiangsu, P.R. China
Tel : 86-510-8534-6666~8005 Fax : 86-510-8534-4078 E-Mail : sojin@lsis.com
LS Hukai Electric(Hubei) Co., Ltd./CHINA
No. 100, Tanjiahe Road, Dianjun District, Yichang City, Hubei Province, P.R. China
Tel : 86-717-667-7339 Fax : 86-717-667-7559 E-Mail : jaewoongh@lsis.com
LS-VINA Industrial Systems Co., Ltd./VIETNAM
Nguyen Khe, Dong Anh, Hanoi, Vietnam
Tel : 84-4-6275-8055 Fax : 84-4-3882-0220
LSIS(ME) FZE/U.A.E.
LOB 19-205, JAFZA View Tower, Jebel Ali Free Zone, Dubai, United Arab Emirates
Tel : 971-4-886-5360 Fax : 971-4-886-5361 E-Mail : shunlee@lsis.com
LSIS Europe B.V./NETHERLANDS
1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands
Tel : 31-20-654-1420 Fax : 31-20-654-1429 E-Mail : eropartner@lsis.com
LSIS Japan Co., Ltd./JAPAN
Tokyo Club Building 13F, 2-6, Kasumigaseki 3-chome, Chiyoda-ku, Tokyo, 100-0013
Tel : 81-3-6268-8241 Fax : 81-3-6268-8240 E-Mail : jschuna@lsis.com
LSIS USA Inc./U.S.A.
2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of America
Tel : 1-847-941-8240 Fax : 1-847-941-8259
Specifications in this catalog are subject to change without notice due to continuous product
development and improvement.
2014. 10