Pall HC Series
Pall HC Series
Pall HC Series
com/contact
Specifications
MaximumAllowableWorkingPressure:
250 psi (17 bar)
Temperature Range:
Nitrile seals -45Fto225F(-43Cto107C) Fluorocarbon seals -20Fto250F(-29Cto120C) 140F(60C)maximuminHWCForwater-glycol fluids
Dry Weights:
S length 22.5 lbs. (10.2 kg) T length 23.7 lbs. (10.8 kg) U length 25.0 lbs. (11.3 kg) V length 31.0 lbs. (14.1 kg)
Caution:
120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)
Dimensional Drawings
Page 1 / 6
Page 2 / 6
Performance
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.
OrderingInformation
AssemblyP/N:H Table1 6400
Table2 Table3 Table4 Table5 Table6 Table7
Table8 Table9
Page 3 / 6
ElementP/N:HC 6400F
TABLE 2: PORT STYLE OPTIONS Code A B D Port Style SAE J514 straight thread NPT Flange SAE J518c-Code 61
* Use code in second column for element part no. ** Nominal length in inches.
Page 4 / 6
8 9 V
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS Code PM DM LL TL ML SL BL PL DL Description Visual indicator with thermal lockout Visual indicator with no thermal lockout Electrical switch (SPDT) with 6" leads Electrical switch with DIN connector TLtype switch with matching wiring cap Electrical switch with MS receptacle Plug in place of indicator Same as PM but with plastic body Same as DM but with plastic body
Indicator and switch pressure settings. 16 psid with "A"and "8" bypass valve. 35 psid with "W," "V," "B," and "9" option.
TABLE 8: SECONDARY PORT OPTIONS Code S N Port Option Port machined Non-machined Port Size 1-1/4" -
Port opposite main inlet in style consistent with main inlet port (see Table 2).
TABLE 9: AUXILIARY PORT OPTIONS Code R L B N Port Option Right side* Left side* Both Non-machined Port Size 1" 1" 1" -
* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2), except that "A" style auxiliary port(s) is used with "D" style main inlet port.
Page 5 / 6
Contact Information
Corporate Headquarters: Pall Corporation, 25 Harbor Park Drive, Port Washington, New York, USA 11050, Web: www.pall.com, Tel: 1-516-484-5400, Contact: www.pall.com/contact
2011, Pall Corporation, Pall, and other names are trademarks of Pall Corporation. indicates a registered trademark in the USA. Revision Date: 08/25/2010
http://pall.com/main/Industrial-Manufacturing/Product.page?id=18650Thursday,January12,20129:44:24 AM
Page 6 / 6