TF4 Mar 20 06
TF4 Mar 20 06
TF4 Mar 20 06
PRODUCT SPECIFICATIONS
100 psi (6.85 bar) maximum 75 gpm, 281 lpm 2.5:1 150 psid (10 bar) Head: Cast aluminum (impregnated) Bowl: Conductive synthetic Fluid compatibility Compatible with petroleum (ISO 2948) based oils, specified water based, oil/water emulsion, and specified synthetic fluids with Flurocarbon or EPR seals (call for compatibility) Bypass setting 25 psid (1.77 bar) standard Weight (w/element) With element 3.4 Lbs, 1.53 kg Temperature rating Buna: -40oF (-40oC) to 225oF (107oC) Viton: -15oF (-26oC) to 275oF (135oC)
Viton is a registered trademark of DuPont
Operating Pressure Maximum Flow rate Design safety factor Element collapse Assembly material
www.filterelement.com
1. Calculate p coefficient at both operating and cold start viscosity: Actual Operating Viscosity (SSU) Actual S.G. p Coefficient = x 150 0.86 2. Calculate actual clean filter assembly p at both operating and cold start viscosity: Actual assembly clean p 3. = Flow rate x p Coefficient x Assembly p factor (from sizing table)
www.filterelement.com
TF4
TF4 ELEMENT PART NUMBER GUIDE
table 2
table 4
HP 4C L9 BOLD text denotes standard options that are available for quick shipment. Non-standard options are subject to longer lead times.
table 1 code Omit D port configuration Single inlet port Double inlet port 180o orientation
table 2 code 1M 3M 6M 10A 10M filtration rating 2.5[c] = 1000 ( 1 = 200) 5[c] = 1000 ( 3 = 200) 7[c] = 1000 ( 6 = 200) 12[c] = 1000 (12 = 200) 12[c] = 1000 (12 = 200) 16[c] = 1000 (17 = 200) 16[c] = 1000 (17 = 200) 22[c] = 1000 (25 = 200) 22[c] = 1000 (25 = 200) 25u nominal 40u nominal 74u nominal 149u nominal media type G7 Dualglass G7 Dualglass G7 Dualglass Water removal G7 Dualglass Water removal G7 Dualglass Water removal G7 Dualglass wire mesh wire mesh wire mesh wire mesh
table 3 code B4 S4 N4 porting options BSPT 1 1/4" SAE-20, 1 1/4 NPT 1 1/4
table 5 code M E D X pressure indicator Visual Pressure Gage 3-wire Electrical Pressure Switch DIN Electrical Pressure Switch No indicator (Pressure ports plugged)
table 6 code H4 special options HPK series element instead of HP4C coreless. HPK conforms to AIAG HF4 automotive standard. For element part number replace 4C with K
Hy-Pro filters are tested to the latest industry standard ISO16889 (replacing ISO4572) resulting in A new scale for defining particle sizes and determining filtration ratio (formerly known as beta ratio)
New (ISO16889) vs Old (ISO4572) size comparison 5 7 12 22 x(c)=1000 (ISO16889) 2.5 x=200 (ISO4572) <1 3 6 12 25
www.filterelement.com
FILTER MEDIA . . . THE HEART OF A FILTER Dynamic Filter Efficiency (DFE) Testing
Revolutionary test methods assure that DFE rated elements perform true to rating even under demanding variable flow and vibration conditions. Todays industrial and mobile hydraulic circuits require elements that deliver specified cleanliness under ALL circumstances. Wire mesh supports the media to ensure against cyclical flow fatigue, temperature, and chemical resistance failures possible in filters with synthetic support mesh. Contact your distributor or Hy-Pro for more information and published articles on DFE testing.
Media Options
Through extensive testing we have developed media choices to handle any application. Options include G7 Dualglass, G7 Dualglass + Water Removal and Stainless steel wire mesh.
Fluid Compatibility
Petroleum based fluids, water glycol, polyol ester, phosphate ester, High water based fluids, and many other synthetics. Contact us for seal material selection assistance.
1M 3M 6M
media description G7 Dualglass high performance media combined with water removal scrim. x[c] = 1000 (x = 200) G7 Dualglass our latest generation of DFE rated, high performance glass media for hydraulic & lubrication fluids. x[c] = 1000 (x = 200) Stainless steel wire mesh media x[c] = 2 (x = 2) nominally rated
Beta Ratio
1000
100
W
10 2.5 4 5 6 7 10 12 16 22 25
www.filterelement.com
www.filterelement.com
www.filterelement.com