PACKAGED
TERMINAL AIR CONDITIONERS?
Engineered for year-round comfort. Easy-to-operate. Whisper quiet. GE Zoneline
units stand out as the premium choice for virtually any application even
in extreme conditions. As the most energy-efcient packaged terminal air
conditioner in the industry, Zoneline keeps costs low and prots high.
LOW ENERGY COSTS.
ONGOING SAVINGS.
Zonelines are the most efcient PTAC/PTHP
in the industry. The more energy efcient, the
lower the utility costs.
PEACE AND QUIET
Cross-ow blower and two fan motors create
less noise to ensure all-around comfort without
all the commotion.
OUTLASTING THE ELEMENTS
Frigid temperatures? Sweltering heat? GE
Zoneline automatically protects against damage
and ensures long-lasting performance.
KEY FEATURES
CROSS-FLOW BLOWER
A unique cylindrical shape causes the air
to move and respond with equal power,
but with less noise than traditional fans.
ELECTRONIC TOUCH CONTROLS
Microcomputer-touch controls with a touch
pad and LED readout give the user better
control over the temperature.
ELECTRONIC TEMPERATURE LIMITING
Heating and cooling temperature can be
limited to prevent expensive over-cooling
or over-heating. Heating and cooling limits
are also automatically set so seasonal
adjustment is not necessary.
THE DRY AIR 25*
Using GEs exclusive patented Dinh
Dehumidier Heat Pipe from Heat Pipe
Technology, Inc. innovative technology
removes 25% more moisture from
the air than standard GE packaged
terminal air conditioners. Perfect for
high-humidity climates.
HEAT SENTINEL
If the temperature of an occupied room
reaches 85, Zoneline units provide
automatic protection against over-heating
by switching on the unit to cool the room.
FREEZE SENTINEL
Protects against damage caused by
freezing temperatures in unoccupied
rooms, regardless of unit setting.
OPTIONAL CORROSION TREATMENT
Placed on the outdoor coil and other
components to reduce the effects of
corrosive environments and extend the
life of the unit.
TWO FAN MOTORS
Separate motors for indoor and outdoor
fans assure quiet operation and comfortable
conditions.
SMARTFAN CYCLE SELECTION
Automatically selects fan cycle for heat and
fan continuous for cooling to provide better
guest comfort and eliminate the need for
changing the fan switch seasonally.
*Available on 7000, 9000 and 12000 BTU models.
RESISTANCE HEAT LINE UP
Deluxe 4100 series
AZ41E07D
7,300/7,100 BTU,
12.8/12.8 EER, 230/208 Volts
AZ41E09D
9,700/9,600 BTU,
12.1/12.1 EER, 230/208 Volts
AZ41E12D
11,800/11,600 BTU,
11.8/11.8 EER, 230/208 Volts
AZ41E15D
14,400/14,200 BTU,
10.5/10.5 EER, 230/208 Volts
AZ41E07E
7,300 BTU, 12.8 EER, 265 Volts
AZ41E09E
9,800 BTU, 12.1 EER, 265 Volts
AZ41E12E
12,000 BTU, 11.8 EER, 265 Volts
AZ41E15E
14,600 BTU, 10.6 EER, 265 Volts
Deluxe Dry Air 25
AZ41E07DAP
6,800/6,600 BTU,
12.2/12.2 EER, 230/208 Volts
AZ41E09DAP
9,300/9,100 BTU,
11.8/11.8 EER, 230/208 Volts
AZ41E12DAP
11,200/11,000 BTU,
11.3/11.3 EER, 230/208 Volts
AZ41E07EAP
6,800 BTU, 12.2 EER, 265 Volts
AZ41E09EAP
9,400 BTU, 11.8 EER, 265 Volts
AZ41E12EAP
11,200 BTU, 11.3 EER, 265 Volts
Specications subject to change
HEAT PUMP LINE UP
ALL MODELS INCLUDE:
Tactile touchpad controls
Solid-state thermostat
3-position vent control
Automatic indoor frost control
Cross-ow blower
Freeze Sentinel and Heat Sentinel
Remote thermostat capability
HEAT PUMP UNITS
INCLUDE:
Staged heating
Heat pump with resistance heat
back-up
Heat pump with supplemental
resistance heat
Electric resistance heat lockout
Reverse cycle defrost
Deluxe 6100 series
AZ61H07D
7,200/7,000 cooling BTU,
6,400/6,200 heating BTU
13.2/13.2 EER, 230/208 Volts
AZ61H09D
9,400/9,200 cooling BTU,
8,300/8,100 heating BTU
12.7/12.7 EER, 230/208 Volts
AZ61H12D
11,800/11,600 cooling BTU,
10,600/10,400 heating BTU
12.1/12.1 EER, 230/208 Volts
AZ61H15D
14,700/14,500 cooling BTU,
13,500/13,400 heating BTU
10.8/10.8 EER, 230/208 Volts
AZ61H07E
7,200 cooling BTU,
6,400 heating BTU
13.2 EER, 265 Volts
AZ61H09E
9,400 cooling BTU,
8,300 heating BTU
12.7 EER, 265 Volts
AZ61H12E
11,800 cooling BTU,
11,000 heating BTU
11.9 EER, 265 Volts
AZ61H15E
14,500 cooling BTU,
13,600 heating BTU
10.8 EER, 265 Volts
Specications subject to change
ZONELINE PTAC CHART
DELUXE SERIES
COOLING & ELECTRIC HEAT
230/208V MODELS AZ41E07D AZ41E09D AZ41E12D AZ41E15D AZ41E07DAP AZ41E09DAP AZ41E12DAP
Cooling BTUH 7,300/7,100 9,700/9,600 11,800/11,600 14,400/14,200 6,800/6,600 9,300/9,100 11,200/11,000
EER (BTU/Watt) 12.8/12.8 12.1/12.1 11.8/11.8 10.5/10.5 12.2/12.2 11.8/11.8 11.3/11.3
Dehumidification Pts/Hr 1.7 2.7 3.5 4.6 2.3 3.4 4.4
Refrigerant type R-410A R-410A R-410A R-410A R-410A R-410A R-410A
CFM, indoor fan high 290 340 420 409 220 280 330
CFM, indoor fan low 218 229 323 324 190 208 270
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45 50/40 70/45 75/45
Power factor 89% 93% 93% 90%/92% 86%/87% 92% 92%
Sensible heat ratio @ 230 volts 80% 75% 70% 70% 60% 60% 60%
Watts 570/555 805/795 1000/985 1370/1350 555/540 790/770 995/975
Cooling Amperes, F.L. 2.8/3.0 3.6/3.9 4.7/5.1 6.0/6.5 2.8/3.0 3.6/3.9 4.7/5.1
Amperes, L.R. 19.0 21.0 29.5 31.0 19.0 21.0 29.5
Weight (Net/Ship) 89.5/102.5 99.9/112.9 99.4/112.4 100.3/113.3 97.0/110.0 105.2/118.2 105.4/118.4
265V MODELS AZ41E07E AZ41E09E AZ41E12E AZ41E15E AZ41E07EAP AZ41E09EAP AZ41E12EAP
Cooling BTUH 7,300 9,800 12,000 14,600 6,800 9,400 11,200
EER (BTU/Watt) 12.8 12.1 11.8 10.6 12.2 11.8 11.3
Dehumidification Pts/Hr 1.7 2.7 3.5 4.6 2.3 3.4 4.4
CFM, indoor fan high 290 340 420 406 220 280 330
CFM, indoor fan low 215 229 323 324 190 208 270
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45 50/40 70/45 75/45
Power factor 90% 91% 92% 92% 87% 91% 92%
Sensible heat ratio @ 265 volts 80% 75% 70% 70% 60% 75% 60%
Watts 570 810 1020 1380 555 800 995
Cooling Amperes, F.L. 2.4 3.2 4.1 5.7 2.4 3.2 4.1
Amperes, L.R. 12.0 16.5 23.5 26.0 12.0 16.5 23.5
Weight (Net/Ship) 91.3/104.3 101.2/114.2 99.9/112.9 101.0/114.0 97.4/110.5 104.9/117.9 108.0/121.0
Specifications subject to change.
4100 SERIES UNITS DRY AIR 25
DELUXE SERIES
HEAT PUMP UNITS
230/208V MODELS AZ61H07D AZ61H09D AZ61H12D AZ61H15D
Cooling BTUH 7,200/7,000 9,400/9,200 11,800/11,600 14,700/14,500
EER (BTU/Watt) 13.2/13.2 12.7/12.7 12.1/12.1 10.8/10.8
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 212 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power factor 91% 92% 92% 91%/92%
Sensible heat ratio @ 230 volts 85% 75% 70% 65%
Cooling Watts 545/530 740/725 975/960 1,350/1,330
Cooling Amperes, F.L. 2.6/2.8 3.5/3.8 4.6/5.0 6.3/6.8
Amperes, L.R. 19.0 21.0 29.5 31.0
Reverse cycle heat BTUH 6,400/6,200 8,300/8,100 10,600/10,400 13,500/13,400
COP 4.0/4.0 3.8/3.8 3.7/3.7 3.3/3.3
Heating Watts 470/455 645/630 850/835 1,190/1,180
Heating Amperes 2.2/2.4 3.1/3.3 4.1/4.5 5.8/6.3
Weight (Net/Ship) 94.1/107.1 101.4/114.4 102.1/115.1 100.8/113.8
265V Models AZ61H07E AZ61H09E AZ61H12E AZ61H15E
Cooling BTUH 7,200 9,400 11,800 14,500
EER (BTU/Watt) 13.2 12.7 11.9 10.8
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 211 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power factor 94% 90% 92% 93%
Sensible heat ratio @ 265 volts 85% 75% 70% 65%
Cooling Watts 545 740 990 1,340
Cooling Amperes, F.L. 2.2 3.1 4.0 5.4
Amperes, L.R. 12.0 16.5 23.5 26.0
Reverse cycle heat BTUH 6,400 8,300 11,000 13,600
COP 4.0 3.8 3.7 3.3
Heating Watts 470 645 870 1,200
Heating Amperes 2.0 2.7 3.6 5.0
Weight (Net/Ship)* 94.6/107.6 103.6/116.6 103.6/116.6 104.3/117.3
6100 SERIES UNITS
*ICR adds 3 pounds to unit weight
**Corrosion model BTUH and watts may vary.
Specifications subject to change.
ZONELINE MUST-HAVES
GRILLE OPTIONS
Extruded aluminum: RAG67 (Shown)
Stamped aluminum grille: RAG60
Exterior architectural louvers
Durable polycarbonate:
RAG61 (Warm Grey Beige)
RAG62 (Maple)
RAG63 (Bittersweet Chocolate)
Chassis
Wall sleeve (optional)
RAB71A (Shown)
RAB77A4 (SMC) (not Shown)
Cross-flow blower
Room cabinet
Grille
WALL SLEEVE
Heavy-gauge galvanized steel with
a baked enamel finish for outstanding
protection and appearance.
RAB71A wall sleeve
Heavy-gauge galvanized steel,
with insulation. A42", B13-3/4", C16"
RAB77A4 wall sleeve (shown above)
Molded SMC fiberglass-reinforced polyester
compound. A42-1/8", B13-7/8", C16-1/4"
Wall opening dimensions
Add 1/4" to A and C dimensions for all cutout sizes.
RAB71A 16-1/4" min. H x 42-1/4" min. W
RAB71A available in 16", 24", 28" and 31" depths.
RAB77A4 16-1/2" min. H x 42-3/8" min. W
B
C
A
Retrofit kits (not shown)
RAK901L - Wall Case Insulation kit
RAK40 - Deflector Kit to adapt
chassis for use with existing exterior
architectural louvered grilles
Requires power connection kit
ELECTRICAL CONNECTION
230/208 volt units may be plugged into a receptacle.
265 volt units are provided with a junction box and
require direct connection. (NEC Requires 265V Direct
Connection.) See Architects and Engineers Design
Data Manual for electrical connection information
including use of sub-base for direct-connected units.
Installation must comply with local electrical codes
and regulations.
DUCTED APPLICATIONS
6100 and 4100 series can be used with ductwork
to heat or cool more than one room. RAK6052
Duct Adapter is applied to top of case over air
discharge. RAK601 Duct Extension is applied to
right or left of adapter. For additional information
on ducted applications, including special adapters
for replacement units, refer to Architects and
Engineers Design Data Manual.
SUB-BASE
MODEL VOLTAGE AMPS RECEPTACLE
RAK204U N/A N/A N/A
RAK204D15P 230/208 15 NEMA6-20R
RAK204D20P 230/208 20 NEMA6-20R
RAK204D30P 230/208 30 NEMA6-30R
RAK204E15 265 15 NEMA7-15R
RAK204E20 265 20 NEMA7-20R
RAK204E30 265 30 NEMA7-30R
230/208 Volt sub-bases include appropriate power cord kit.
265 Volt units are to be direct connected. Cordset through enclosed chaseway into interior
sub-base receptacle meets the NEC requirements.
Tandem
230/208V 15 Amp
NEMA6-15R
Perpendicular
230/208V 20 Amp
NEMA6-20R
Large tandem
230/208V 30 Amp
NEMA6-30R
265V 15 Amp
NEMA7-15R
265V 20 Amp
NEMA7-20R;
receptacle used
On 265V sub-base
GE0720-3
265V 30 Amp
NEMA7-30R;
receptacle used
On 265V sub-base
GE073
RECEPTACLES/SUB-BASES
POWER CONNECTION KITS ARE REQUIRED ON ALL ZONELINE
.
Power connection kits
Required on all models. See specification sheet
for heater KW and branch circuit ampacity.
RAK3153A/3203A/3303A
230/208 volt line cord
connection kit
RAK4157/4207/4307
230/208 volt universal
power supply kit
RAK5157/5207/5307
265 volt universal power
supply kit
230/208 VOLT LINE CORD CONNECTED UNITS
LCDI Power
Connection Kit RAK3153A RAK3203A RAK3303A
Heater KW 2.4/2.32 3.3/3.2 4.7/4.53
Watts 2,400/2,320 3,300/3,200 4,700/4,530*
BTUH 8,150/7,900 11,200/10,900 16,000/15,450
Amps 11.0/11.6 15.1/16.0 21.2/22.4
Min. circuit amps 15 20 30
Recommended
protective device
15 amp time delay
fuse or breaker
20 amp time delay
fuse or breaker
30 amp time delay
fuse or breaker
265 VOLT PERMANENT CONNECTED UNITS** (CORD SET)
RAK5172 RAK5202 RAK5302
2.4 3.4 4.8
2,400 3,400 4,800*
8,150 11,550 16,350
9.6 13.3 18.6
15 20 30
15 amp time delay
fuse or breaker
20 amp time delay
fuse or breaker
30 amp time delay
fuse or breaker
265 VOLT DIRECT CONNECTION KIT