Motivair
Motivair
Motivair
Industrial
Heat Recovery
Cooling Economizers
COOLING SOLUTIONS
www.motivaircorp.com
Motivair closed-loop uid cooling systems dramatically cut utility and maintenance costs when applied to water-cooled industrial equipment
including molding machines, air compressors, furnaces, and hydraulic systems. They are also ideal for FreeCooling economizers on chillers, when used to pre-cool the return chilled water during winter operation.
and tested before shipment. The heat exchanger features a galvanized housing for indoor or outdoor use. Copper tubes and aluminum ns provide superior heat transfer. Fans are compartmentalized for efcient fan cycling. Solid-state fan sequencer is standard on multiple fan units. All heat exchangers are tested to 400 PSIG and multiple fan units are shipped with a pre-wired control panel.
Shell and tube trim cooler Copper ns Coil coating for corrosive environments Stainless steel construction
MFC SPECIFICATIONS
FLUID COOLER MODEL MFC0200 MFC0250 MFC0300 MFC0350 MFC0400 MFC0450 MFC0500 MFC0550 MFC0600 MFC0700 MFC0800 MFC0900 MFC0950 MFC1000 MFC1100 MFC1200 MFC1300 MFC1400 MFC1500 MFC1600 MFC1700 MFC1800 MFC1900 MFC2000 MFC2100 FLOW RATE (GPM) 22 28 34 39 45 51 56 62 68 79 90 101 107 113 124 135 146 158 169 180 191 203 214 225 236 HEAT REJECTION CAPACITY* (BTU/HR) 200,000 250,000 300,000 350,000 400,000 450,000 500,000 550,000 600,000 700,000 800,000 900,000 950,000 1,000,000 1,100,000 1,200,000 1,300,000 1,400,000 1,500,000 1,600,000 1,700,000 1,800,000 1,900,000 2,000,000 2,100,000 NO. OF FANS 2 2 2 2 3 3 3 4 4 4 6 6 6 6 6 8 8 8 10 10 10 10 12 12 12 TOTAL AIRFLOW (SCFM) 21,000 20,600 19,800 18,500 30,900 29,700 28,600 41,200 39,600 37,000 61,000 60,600 59,400 57,200 55,500 79,200 76,300 74,000 99,000 98,200 95,300 92,500 117,900 114,400 111,000 L 90 90 90 76 130 130 130 231/121** 231/121** 231/121** 341/176** 341/176** 341/176** 341/176** 341/176** 231 231 231 286 286 286 286 341 341 341 OVERALL DMENSIONS(IN.) W 43 43 43 43 43 43 43 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 H 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 INT VOL. (GAL.) 6 9 9 12 17 17 22 18 18 24 27 27 27 36 36 36 48 48 45 60 60 60 72 72 72 EMPTY WEIGHT (LBS.) 580 630 650 730 900 930 1010 1580 1620 1760 1810 2390 2440 2550 2610 3140 3200 3510 3990 4000 4150 4380 4710 4890 5230
*Performance based on 40% glycol entering the cooler @ 125o F, leaving the cooler @ 105o F, & 95o F ambient. **These coolers are available in eiher a 1-fan or 2-fan-wide conguration. Contact Motivair for Economizer (Free-Cooling) applications!
COMPONENTS
The MEC Series Closed Loop Evaporative Towers consist of four main components: (1) the cooling coil; (2) the spray system; (3) the fan system; and (4) the discharge mist eliminators.
The spray pump continuously drenches the tubular heat exchanger surface with a spray of re-circulated water, while the fan forces ambient air across the coil. The evaporation of the spray water removes heat from the closed loop uid at temperatures below the ambient dry bulb temperature. The evaporative cooling effect is based on the prevailing wet bulb temperature, which is a measurement of moisture in the air. (A lower wet bulb temperature increases evaporation from the cooler, and directly increases capacity.)
In most areas of North America the maximum ambient wet bulb temperature is below 78F, and it rarely exceeds 80F. In general, this makes Evaporative Closed Loop Systems ideally suited for use when the maximum required cooling water temperature is around 85F. Water consumption is approximately 2 GPM per million Btu/h for evaporation losses, plus occasional blow downs to clean the sump.
MEC SPECIFICATIONS
FLUID COOLER MODEL MEC0300 MEC0400 MEC0500 MEC0700 MEC0900 MEC1100 MEC1300 MEC1600 MEC1800 MEC2000 MEC2200 MEC2400 MEC2800 MEC3400 MEC3800 FLOW RATE (GPM) 27 `36 45 63 81 99 117 144 162 180 198 216 252 306 342 HEAT REJECTION CAPACITY* (BTU/HR) 300,000 400,000 500,000 700,000 900,000 1,100,000 1,300,000 1,600,000 1,800,000 2,000,000 2,200,000 2,400,000 2,800,000 3,400,000 3,800,000 TOTAL AIRFLOW (SCFM) 6,400 9,300 9,200 14,700 14,400 20,500 20,500 29,400 29,400 40,500 40,200 40,100 61,200 61,000 60,000 FAN MOTOR HP 3 5 5 7.5 7.5 15 15 15 15 20 20 20 30 30 30 SPRAY PUMP HP 0.5 0.75 0.75 1 1 1.5 1.5 1 1 1.5 1.5 1.5 3 3 3 PAN HEATER KW 3 3 3 4.5 4.5 6 6 4.5 4.5 6 6 6 9 9 9 A 70 70 70 130 130 130 130 135 135 135 135 135 195 195 195 OVERALL DMENSIONS(IN.) B 67 78 78 73 73 84 84 103 103 126 126 126 126 126 126 C 114 107 114 100 114 107 114 107 114 100 107 114 100 107 114 OPER. WEIGHT (LBS.) 2,790 3,630 3,895 4,520 5,455 6,580 6,990 8,670 8,910 11,020 11,270 11,600 14,880 15,870 17,410
*Performance based on 40% glycol entering the cooler @ 115o F, leaving the cooler @ 90o F, & 78o F ambient. **See Closed Loop Water Cooling Systems brochure for pump station details.
The sprinkler pipes are sturdy PVC material pierced with closely-spaced holes allowing thorough distribution of water in a rotating spray covering the entire surface of the lller.
The efciently designed PVC ller creates a surface area that allows for maximum dispersion of water which creates a superior cooling effect.
The round design permits maximum air intake regardless of wind direction.
A large-capacity, durable water basin constructed from rust-proof berglass reinforced platic gurantees low maintenance and long-term operation.
A large diameter outlet pipe draws a constant supply of cooled water from the basin to serve the facility.
MOT SPECIFICATIONS
Water IN Water OUT Wet Bulb 90F 80F 65F 9 15 24 30 46 61 77 91 122 152 183 214 244 306 381 456 533 608 691 765 920 1065 1220 1502 1825 2108 2433 2994 3740 4491 90F 80F 70F 6 10 18 21 33 44 56 68 90 114 137 160 183 228 287 346 401 461 509 570 681 808 920 1182 1386 1648 1848 2379 2977 3568 95F 85F 70F 9 15 24 30 47 62 78 93 124 156 187 218 250 311 390 468 546 624 702 780 936 1092 1249 1560 1873 2185 2498 3121 3902 4683 92F 82F 72F 7 11 19 23 35 48 60 72 97 121 146 170 195 243 305 368 428 490 543 608 727 859 979 1250 1473 1745 1965 2514 3146 3771 95F 85F 75F 8 12 20 26 40 52 66 80 107 134 160 187 214 268 335 403 470 539 600 670 801 942 1075 1363 1616 1904 2155 2735 3421 4102 97F 87F 75F 9 15 24 30 47 62 78 93 124 156 187 218 250 311 390 468 546 624 702 780 936 1092 1249 1560 1873 2185 2498 3121 3902 4683 95F 85F 77F 6 10 18 21 33 44 56 68 91 115 137 160 183 229 288 348 403 464 508 571 682 812 924 1200 1394 1670 1860 2421 3032 3632 95F 85F 78F 6 10 16 20 30 40 50 61 83 105 125 145 168 208 262 318 369 426 460 520 620 744 845 1113 1278 1546 1703 2253 2824 3380 96F 86F 80F 5 9 14 18 28 37 47 57 77 98 116 135 156 193 245 297 344 398 427 484 575 695 788 1053 1194 1459 1592 2139 2683 3209 98F 88F 82F 6 10 15 20 30 40 50 61 82 104 124 144 167 207 261 318 367 425 457 518 616 742 842 1119 1275 1551 1700 2270 2846 3404 90F 83F 75F 8 13 22 28 41 56 70 84 112 140 169 197 225 281 352 422 493 563 633 704 845 986 1127 1408 1690 1971 2255 2815 3519 4223 94F 85F 75F 9 14 23 29 43 58 72 87 116 145 174 203 232 290 362 435 508 580 652 725 871 1016 1161 1453 1742 2035 2323 2908 3635 4361 M O T 3 5 8 10 15 20 25 30 40 50 60 70 80 100 125 150 175 200 225 250 300 350 400 500 600 700 800 1000 1250 1500
G P M
Application description Fluid to be cooled & ow rate Fluid temperature entering exchanger Required leaving uid temperature Available cooling water ow and temperature Allowable pressure drops Process uid pump available pressure (PSI)
PUMP/TANK STATIONS
Every open and closed loop cooling tower requires a pumping package in order to circulate the cooled water or glycol to and from the designated process. Motivair designs and builds a full range of pump stations and pump/tank station packages that can be customized to suit any application (See Pump Station brochure for further details). Available options include: Simplex, duplex or triplex pumps Stainless steel water circuit Automatic pump change over Visible & audible alarms Flow meters Bafed tanks Automatic water make-up
Pressure & temperature gauges Isolation & check valves NEMA 4 control box VFD pump speed control High pressure pump option Redundant pump packages
MLC 70-240 ton air-cooled, water-cooled & split system chillers for central plant operation, industrial processes or HVAC applications. Integrated Free-Cooling option
25 John Glenn Drive Amherst, NY 14228 Tel: 716-689-0222 Fax: 716-689-0073 www.motivaircorp.com