P127
P127
P127
-
A
R
E
V
A
-
2
0
0
9
.
A
R
E
V
A
,
t
h
e
A
R
E
V
A
l
o
g
o
a
n
d
a
n
y
a
l
t
e
r
n
a
t
i
v
e
v
e
r
s
i
o
n
t
h
e
r
e
o
f
a
r
e
t
r
a
d
e
m
a
r
k
s
a
n
d
s
e
r
v
i
c
e
m
a
r
k
s
o
f
A
R
E
V
A
.
M
i
C
O
M
i
s
a
r
e
g
i
s
t
e
r
e
d
t
r
a
d
e
m
a
r
k
o
f
A
R
E
V
A
.
A
l
l
t
r
a
d
e
n
a
m
e
s
o
r
t
r
a
d
e
m
a
r
k
s
m
e
n
t
i
o
n
e
d
h
e
r
e
i
n
w
h
e
t
h
e
r
r
e
g
i
s
t
e
r
e
d
o
r
n
o
t
,
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
t
h
e
i
r
o
w
n
e
r
s
.
-
3
8
9
1
9
1
9
8
2
R
C
S
P
A
R
I
S
-
P
r
i
n
t
e
d
i
n
F
r
a
n
c
e
-
S
O
N
O
V
I
S
I
O
N
-
I
T
E
P
AREVA T&D Worldwide Contact Centre:
http://www.areva-td.com/contactcentre/
Tel.: +44 (0) 1785 250 070
www.areva-td.com
www.areva-td.com/protectionrelays
AREVA TRACK RECORD -
OVERCURRENT PROTECTION
>> MCGG: First Microprocessor based overcurrent relay launched
in 1984. More than 80000 devices installed.
>> OPN/MODN: First Numerical overcurrent relay launched in 1988.
More than 9800 devices installed.
>> PS4xx: First Numerical overcurrent relay launched in 1990.
More than 25000 devices installed.
>> KCGG/KCEG/KCEU: First Numerical overcurrent relay launched
in 1993. More than 75000 devices installed.
>> MX3AMxxx: First Numerical overcurrent relay launched in 1995.
More than 14000 devices installed.
>> MiCOM P12x and P12y range: First MiCOM P20 Numerical
overcurrent relay launched in 1998. More than 200 000 devices
installed.
Our policy is one of continuous development. Accordingly the
design of our products may change at any time. Whilst every effort
is made to produce up to date literature, this brochure should only
be regarded as a guide and is intended for information purposes
only.Its contents do not constitute an offer for sale or advise on the
application of any product referred to in it. We cannot be held
responsible for any reliance on any decisions taken on its contents
without specific advice.
> Logic Equations
The MiCOM P121/2/3 & P126/7 relays integrate
complete logic equations to allow customization of the
product based on customer application.
Up to 8 independent Boolean equations can be used.
Each equation offers the possibility to use AND, OR &
NOT logical gates. Up to 16 parameters can be used
for each equation including any threshold and
opto-input status. Every result of equation can be
time delayed and assigned to any output relays, trip,
trip latching and/or HMI LEDs.
Each boolean equation result can be alarmed or not.
> MiCOM S1 Studio Support Software
A Support Software MiCOM S1 is available for the
entire MiCOM family, including P12x/y relays. S1 is fully
Windows TM compatible. This support Software allows
easy setting of any MiCOM P12x/y model, preparing,
storing, and retrieving setting files for further download
on relay. In addition S1 makes possible reading
measurements and downloading event, fault and
disturbance records for post-fault analysis purpose.
> Hardware and Case
MiCOM P12x/y are based on advanced numerical
technology. All the models of the MiCOM P12x/y series
have a 4U draw out metal case, and can be flush-
mounted in switchboard or panel or rack-mounted.
All the CT inputs are automatically short-circuited as
soon as the active unit is withdrawn in its case.
To insure a compliance with any auxiliary voltage
source and minimize variants, a universal power supply
board from 24 to 250Vac/dc is available along the
MiCOM P12x/y range.
> Wiring
External connections are made via MIDOS type
terminal blocks. Each connection includes two 4.8 mm
Faston and one M4 screw fixing. The wiring for all the
MiCOM P12x/y are standard to provide maximum
compatibility.
Optos
Protection
elements
Automatic
Control
Timers
Gate Logic
LED's
Relay
contacts