The passage discusses Japanese Industrial Standards for standard test conditions including temperature, humidity, air pressure and tolerances.

The standard temperature conditions are either 20°C or 25°C and the standard humidity conditions are either 65% or 50% relative humidity.

Tolerances for temperature range from ±0.5°C to ±15°C depending on the class, and for humidity range from ±2% to ±20% depending on the class.

Japanese Industrial Standards

JIS Z 8703 -1983



Standard conditions of the test site
Standard Atmospheric Conditions for Testing
1.
This standard application range, the temperature of the location where you want to implement (.,
Including the break-in for the test) test in the industrial,
I prescribed for the standard state on pressure and humidity. However, what needs to be tested in a
particular state
It does not include the state of the test location.
Corresponding international standard:
ISO 554 -1,976
Standard atmospheres for conditioning and / or testing-Specifications
IEC Publication 160 -1,963
Standard atmospheric conditions for test purposes
2.
Standard state
2.1
The temperature of the temperature standard condition in the standard state, I will either 20
depending on the purpose of the test, of 25 or 23 .
2.2
Humidity of the humidity standard state of the standard state is either 65% or 50% relative humidity.
2.3
Air pressure in the pressure of the standard state standard condition, and more than 86kPa 106kPa
below.
2.4
Standard state standard condition, set each one of the humidity in the standard condition and
temperature of the standard state under the pressure of the standard state
And a state of the combined saw.
It is also possible to specify only the temperature of the standard state by the remarks purpose. That
the standard temperature condition its state.
Reference 1. ISO 554 According to -1976, and defines three types of standard conditions for
testing. The recommended standard for them
The state, 23 temperature, relative humidity of 50%, has been with the pressure more than 86kPa
106kPa below.
2.
IEC Publication 160 -1,963
According to, 15~35 temperature, relative humidity recommended range of states to be measured
45
The standard temperature conditions as a reference for comparison 75% of each other, also defined
as pressure 860~1060mbar
Twenty
, 65% relative humidity, you are pressure 1013mbar. In addition, the standard of measurement for
the examination and the break-
I have defined three types of state.
Remarks 1
013mbar
Is 101.3kPa.
3.
Tolerance of standard state
3.1
Tolerance of temperature tolerance standard state of the temperature of the standard condition, the
table depending on the purpose of the test 1 to Kyu-betsu as.
Remark 1 is, I will also apply to standard temperature state.

Two
Z 8703-1983
Table 1
Class by
Tolerance
Class 0.5 temperature
0.5
Primary temperature
1
Grade 2 temperature
2
Grade 5 temperature
5
15 temperature class
15
To 20 temperature of standard condition 15 Grade Remarks temperature
Are used only for.
Note that the room temperature the temperature range of 5~35
Says.
3.2
Tolerance of humidity tolerance standard state of humidity of the standard condition, the table
depending on the purpose of the test 2 to Kyu-betsu as.
Table 2
Class by
Tolerance%
Grade 2 humidity
2
Grade 5 humidity
5
10 Grade humidity
10
20 Grade humidity
20
20 Grade Remarks humidity 65% relative humidity in the standard state
I used only for.
In addition, normal humidity humidity range of 45-85%
That.
3.3
Tolerance of tolerance standard state of standard condition, the tolerance of the humidity of the
standard condition and tolerance of the temperature of the standard state
It is assumed that a combination of each one.
4.
Temperature of the standard state, the display of the display standard state in the standard state is due
to tolerance and humidity. It requires a display of tolerance
If not, and will not be displayed.
Example 1 : the temperature of the standard state is 23 , 1 grade temperature, 50% humidity in the
standard state, the class is another place of Class 5 humidity that another class
Synthesis
23
or grade 5 primary 50%, 23 1 50 5%, 23 (1) / 50 (5)
Example 2 : In the case of the above, if you omit the class by
23
23/50 or 50%
Example 3 : room temperature (5~35 ), humidity in the standard state and normal humidity case of
(45-85%) the temperature of the standard state (
*
)
Twenty
Normal temperature 15 65 20%, or 20 (15) / 65 (20), and normal humidity
Note (
*
)
In the case of either the normal humidity or ambient temperature
Example 3 I conform to.
Display Remark standard temperature state is due to tolerance of temperature and standard
temperature state. It does not require the display of tolerance
If omitted the display.
Example 1 : Temperature of the standard temperature condition is 23 , the class Another case of
primary temperature
23
23 1 or primary
Example 2 If you omit the class-specific in the case of the above:
23

Example 3 : temperature of the standard temperature condition if normal temperature (5~35 )
Twenty
15 , 20 (15), or at room temperature