Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ariston Avd109eu

Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

page 1

Model type:
AVD109EU

Commercial code:
30147
page 2








General notes




Technical Documentation guidelines
-------------------------------------------------------------------------------------------------------------------------------
You can find herewith some generic information to simplify cunsulting of technical documentation:

1. Models of same range share the same exploded views, which report the richest set of spare parts:generally, a model does not necessarly have a
related spare part for each particular shown on exploded views.

2. Some spare parts can not be represented directly on the exploded views (instruction booklets, specific kit, etc...). You can find those codes in the
spare parts list with the same reference of particular where spares are installed or with references 099, 999. Instruction booklets, once managed,
appear with 000 reference.

3. On the higher right site of each exploded view there is a serial number which indicates the beginning of the production of certain range:some
models might have more than an exploded view for a given category, each distinguished by a different serial no.and linked to another spare parts
list, In this case, serial no. is required to supply the right spare part code. Exploded view to be considered is the one with a more recent serial no.
but previous than the one of the model that needs assistance.

4.Exploded views might require further updates even after publishing. Addition of new spares will go on following the already existing numeration
references. Revision number of an exploded view is shown into last four digits of serial number into upper right hand corner.

5.The spare parts list associated to an exploded view shows related codes of spares managed for a certain model; for each spare part other
informations are available:

REF: reference no of spare into a table; SUBSTITUTE: list of spare(s) which can replace a code but that keeps same functional characteristics

INDUSTRIAL CODE: list of variables of a model (shown into model label) where such spare is used; NOTICE: code of information(s) to refer to
complete technical intervention, track for changes or to find correct spare part code.

6. Some notices, into a same section are generic therefore cannot be directly linked to a spare part. In order to assist a model in the best way as
possible, it is helpful to pay attention to all notices and constantly verify documentation updates

7.Technical documentation cover shows model name and its commercial codes

page 3







pdf_tavola_title_ENG




cod. 1140960





page 4






Spare parts list



Spare parts list cod. 1140960

Ref. Code Substitute Industrial code Description Notice
001 C00093722 wiring base a 240000700a0
005 C00093719 wiring ml + ps 240000700n0
007 C00093721 wiring terra 240000700y0
008 C00093726 wiring comunic. display
240000700b1
013 C00093714 wiring mr + ip 240000700d0
014 C00093713 wiring evl + evp 240000700c1
page 5







pdf_tavola_title_ENG




cod. 1230150





page 6






Spare parts list



Spare parts list cod. 1230150

Ref. Code Substitute Industrial code Description Notice
000 C00097816 user instructions booklet gb-pl-
hu-ro-p
001 C00091882 pivot pin - drawer front
106.5x5 mm ab
002 C00091889 control avd
003 C00091890 potentiometre support avd
004 C00094065 knob timer disc
005 C00091873 wash timer knob white 27 avd
006 C00094356 push buttons on-off white evo2
007 C00091884 pushbutton display grey right
avd
008 C00091886 pushbutton display grey left
avd
009 C00094205 control panel + handle
avd109it
010 C00092157 door frame and glass assy
evo ii ariston
011 C00092158 door handle kit ariston
012 C00064505 plinth white
013 C00087084 foot - rear
014 C00083828 spring for foot d =11 mm h =
8,5 mm
015 C00046666 collar for drain hose
016 C00064541 hinge assy-outer case/door
180
017 C00081698 rear cover - white
018 C00084817 blanking plate-rear(test plug)
019 C00094777 kit package lvb evo2
020 C00041575 adhesive hook
021 C00097549 cabinet white27 5kg ariston
evo2
022 C00091867 worktop - white 595 x 522 mm
avd avl
page 7
099 C00046667 wiring stop
099 C00064550 dain hose holder
099 C00065871 blanking plug
page 8







pdf_tavola_title_ENG




cod. 1230220





page 9






Spare parts list



Spare parts list cod. 1230220

Ref. Code Substitute Industrial code Description Notice
001 C00095888 belt 1060h9
002 C00064786 bolt m8x20 tefl
003 C00066080 drum pulley d= 210 mm h=17
mm
004 C00094710 upper counterweight 15kg
005 C00094741 screw locking
counterweight/tub
006 C00064515 anchorage pad - suspension
spring
007 C00094714 suspension spring - tank 5kg n1040320,n1040320
007 C00109645 tank spring n1040320,n1040320
008 C00094782 plastic tank lvb evo2 n1040307
009 C00094155 bodytop overflow evo3
010 C00092156 clamping ring - bellows seal
front
011 C00092154 door bellows seal d=30-30 cm
012 C00094711 front counterweight 9,4kg
013 C00008612 tube clamp 34,6-36,4
014 C00092411 hose clamp
015 C00092174 hose tank to filter oko
017 C00055037 plastic expansion rivet
018 C00065152 nut romob m6x20x1,6
019 C00094712 shock absorber 100n
020 C00094908 hose clamp
021 C00066183 hose dispenser to tank
page 10







pdf_tavola_title_ENG




cod. 1230340





page 11






Spare parts list



Spare parts list cod. 1230340

Ref. Code Substitute Industrial code Description Notice
001 C00094203 supply cable 1,5mt shuko 3 f
002 C00019902 plastic -u- to make drain hose
hook
003 C00027466 drain hose - to sink l=1860mm
005 C00091885 wiring dashboard avd avsd
evoii
006 C00087067 programme select bitron 16
positions
008 C00095412 reading desk symbols
009 C00093813 support - programme guide
evo ii
010 C00046154 fabric conditioner cover
011 C00046148 soap dispenser drawer (rotary)
012 C00064529 dispenser body
013 C00064537 support - pressure switch
014 C00094717 pressure switch
015 C00092412 hose clamp
016 C00094746 pipe pressostat l=505
017 C00019755 anti-vibration bush (foam)
018 C00092173 air trap x oko
019 C00091911 door interlock avd
020 C00094715 heating element 1700/230
021 C00083915 temperature sensor ntc elth tl
ph2001
022 C00045027 filter element kit
023 C00076510 1 C00092264 self cleaning pump 240v./50hz.
024 C00094744 screw locking motor/tub
025 C00095892 motor three phase cim2-55
page 12
027 C00097817 eeprom avd109eu evoii sw
28301470001
030 C00094047 support cover 3 f
030 C00094049 bracket for module 3 f
031 C00093916 1 C00097554 module less eeprom t-ph.sth
wd>1200+sc
032 C00046152 additive container
033 C00046157 stopper detergent container
034 C00095669 housing seriale evoii - lb2000 -
pc
n1040317
035 C00092177 hopper cover 1e 2u ev
036 C00093843 electrovalve 2 way 7 lt.rst2,5
037 C00064534 seal - electrovale/dispenser
038 C00005572 sealing washer-mains inlet
hose
040 C00003070 mains inlet hose cold 25c
10bar 1500 mm
042 C00064946 electrovalve support 1 ev
page 13






Notices




n1040296
List of EVOII FAULTS and troubleshooting
-------------------------------------------------------------------------------------------------------------------------------
If a fault occurs on the washing machine then the self test function will

display this, or the new hardware key may be used to show the fault.

The type of fault can be signalled in different ways:

• on AVD models the fault is shown directly on the machine display.

• On AVL models the fault is signalled by LEDs.

2.10.4 Reading of Faults signalled by LEDs

When the machine has a fault:

1. The door is locked

2. The door lock indicator flashes quickly (surely > 1 Hz)

3. The control panel LEDs flash, to signal the fault, according to the table fig. 01.



The example shown in the fig. 02 (Example Fault F03) below indicates which

LEDs flash if the machine has a Fault F03



List of faults, malfunctions and Warnings:



F01: Triac Motor short circuit

• Check for any water leaks that can reach connector J9 short circuiting the

relevant contacts

• Check the motor terminal block (a possible problem due to chemical work

residuals corroding the contacts that can cause a short circuit)
page 14

• Replace Card



F02: Motor blocked, Tachometrics in Short Circuit/Open

• Check motor if blocked

• Check the efficiency of J9 connector on the card

• Check the tachometric winding checking an ohm resistance reading of 115

- 170 ohm between pins 1 and 2 on wiring connector J9. In case of short

circuit, open circuit check the wiring between pins 1 and 2 of J9 relevant

to the tachometrics. With a three-phase motor, make sure there is ohm

continuity between J9 pins 6 and 7.

• Replace motor

• Replace card



F03: Detected: NTC Open or in Short Circuit or wash heater relay stuck (signalled in

presence of full load)

• Check efficiency of J8 connector contacts on the card

• Check NTC verifying that the ohmic resistance value at room temperature

20C is approx. 20Kohm on J8 wiring connector pin 11 and 12.

• If the measurement is incorrect check J8/NTC wiring continuity. Check the

same parameter directly on NCT

• Replace NTC

• Replace Card.



F04: Simultaneous empty and overflow (pressure switch stuck on empty). If the

pressure switch contact is stuck on empty the washing machine loads water until

reaching the overflow. The drain pump is automatically started by the contact on

the overflow pressure switch.

• Check the efficiency of J3 connector contacts on the card.

• Check pressure switch status checking J3 wiring connector pins:

- 2-4 ohm continuity - tub empty

- 2-3 ohm continuity - full tub
page 15

- 2-1 ohm continuity - tub overfilled, at least halfway up door glass

• Check wiring of connector J3/pressure switch

• Replace pressure switch

• Replace card.



F05: Detected: Pump Blocked or pressure switch empty not reached

• Check the efficiency of J9 connector contacts on the card checking the

presence of 220V current between pins 8 and 9.

• Check pump: if fed

• Check Pump Filter + wall drain

• Change Pump

• Replace Card.



F06: Not on AVD and AVL



F07: Detected: No Absorption Wash Heating Element (the fault is only signalled

with the pressure switch on empty)

• Check the efficiency of J3 connector contacts on the card

• Check the continuity of the wash heater on J3 connector pins 5 and 6. The

1800w 230V heating element has a resistance of 25 ohm.

• Check the connection of pressure switch J3 connector pins 2 and 3: there

must not be ohm continuity (shared with full load).

• Check the connection of pressure switch J3 connector pins 2 and 4: there

must be ohmic resistance

• Replace Heating Element

• Replace Pressure Switch

• Replace Card.



F08: Wash Heater Relay Stuck (signalled in presence of empty) or pressure switch

stuck on Full (simultaneously empty and full)

• Check the efficiency of J3 connector contact on the card
page 16

• Check pressure switch status checking J3 wiring connector pins 2 and 4

ohm continuity (it must only be present with tub empty) and pins 2 and 3

ohm continuity (it must only be present with water in the drum) and pins 2

and 1 ohm continuity (it must only be present with water in the tub above

normal level, at least halfway up door glass).

• Check wiring J3/pressure switch

• Check connection of heating element J3 connector pins 5 and 6.

• Replace pressure switch

• Replace Card



F09: Detected: Machine Setup Error (eeprom error)

• In case of production card with eeprom soldered: replace card and eeprom

• In case of replacement of eeprom and card, check the correct housing of

eeprom on card base.



F10: No full and empty signal

• Check the efficiency of J3 connector contacts on the card

• Check pressure switch status checking J3 wiring connector pins:

- 2-4 ohm continuity - tub empty

- 2-3 ohm continuity - full tub

- 2-1 ohm continuity - tub overfilled, at least halfway up door glass

• Check wiring of connector J3/Pressure switch

• Replace Pressure Switch

• Replace Card.



F11: Detected: No Pump Feedback (Drain pump disconnected or winding broken)

• Check the efficiency of J9 connector contacts on the card

• Check continuity of the Pump on J15 connector pins 1 and 2 (in case of

washing machine with Easy Door function) or on J9 connector pins 8 and 9

(in case of conventional door lock), checking resistive value equal to 170 ohm.

• Check wiring of connector J15 (or J9)/Pump
page 17

• Replace Pump

• Replace Card.



F12: No Communication Display Card/LED-Main Card

• Check the efficiency of contacts on card of J11 connector

• Check the continuity of J11 connector-display card 5-pin connector

• Replace Main Card

• Replace Display Card/LED.



F17: Door lock unfed/open (with Easy Door)

• Check the presence of 230V mains power on J4 wiring connector inserted

on board between pins 3 and 4, (not present with machine on standby)

the presence of power from 230V door lock between pins 3 and 5

• Check the ohm continuity of door microswitch (with door closed on and

off) on J4 connector inserted on the board between pins 1 and 2

• Check continuity of J4/door lock wiring

• Check door hooking

• Replace door lock

• Replace card.



F17: Door lock unfed/open (conventional door lock, not Easy Door)

• Check the presence of 230V mains power onJ4 wiring connector inserted

on board between pins 2 and 3, (not present with machine on standby)

the presence of power from 230V door lock between pins 3 and 1

• Check door hooking

• Replace door lock.

• Replace card



F18: DSP (Digital Signal Processor) / microprocessor error

• Replace card


page 18






n1040307

-------------------------------------------------------------------------------------------------------------------------------





n1040317
LB2000, EVOI, EVOII serial key and relevant serial cable.
-------------------------------------------------------------------------------------------------------------------------------
The new serial key Service code 095669, usable on all LB2000, EVOI and EVOII washing machines, can be connected to the PC by means of F/M
9-pole cable Service code 099862 (see fig.001).

The previous F/F pin-to-pin 9-pole serial cable Service code 084943 can be used with the new key only if it is provided with the M/M serial
connector code 099861 (see fig. 002).

Cable code 084943 and serial key code 084566 will be available until stocks run out, after which they will be replaced by ESI with Service codes
099862 and 095669 respectively.




page 19






n1040320

-------------------------------------------------------------------------------------------------------------------------------


page 20



n1040307

-------------------------------------------------------------------------------------------------------------------------------





n1040317
LB2000, EVOI, EVOII serial key and relevant serial cable.
-------------------------------------------------------------------------------------------------------------------------------
The new serial key Service code 095669, usable on all LB2000, EVOI and EVOII washing machines, can be connected to the PC by means of F/M
9-pole cable Service code 099862 (see fig.001).

The previous F/F pin-to-pin 9-pole serial cable Service code 084943 can be used with the new key only if it is provided with the M/M serial
connector code 099861 (see fig. 002).

Cable code 084943 and serial key code 084566 will be available until stocks run out, after which they will be replaced by ESI with Service codes
099862 and 095669 respectively.







page 21



n1040320

-------------------------------------------------------------------------------------------------------------------------------





page 22






Electric schemes and links


Cod. 16001690700



page 23






Legend

Legend: 16001690700


AQS Aquastop electrovalve Mzbn/MTA zbn timer motor
B Buzzer N Neutral or Terminal Board
BC NC Spin cycle exclusion
BF Terminal board contact, motor fan and dryer
heatin
P Pressure switch
BP Buzzer PA High speed potentiometer
C Condensator PB Low speed potentiometer
CA Condensator PL Pure Wool
DV Switching device PM Motor Thermoprotector
EF/CL Electro-Valve Cold Water / Bleach PR Timer programmer or Pressure switch
EF/L Electro-Valve Cold Water / Wash PS Drain pump
EF/P Electro-Valve Cold Water / Prewash P1 1st level pressure cut-off switch
ER Exclude Heating Element P2 2nd level pressure cut-off switch
ET Thermostat disactivation R Heating element
EV Electrovalve Ras/RA Dryer heating element
EVA Dryer electrovalve RE Relay
EVC Hot water electrovalve RR Heating element
EVF Elettrovalvola acqua fredda RV Speed regulator
EVL Wash electrovalve S LED
EVP Pre Wash electrovalve SL Line LED
FA Antijamming filter SO Door LED
FD Delicate drying cycle thermostat SR Heating LED
FE Strong drying cycle thermostat ST Temperature selector
FRT Thermofusible Heating Element SV Speed Selector for Spin
I Inverter T Timer contacts
IA Switch On/Off TA Drying timer contacts
page 24
IC Switch N.C. - 1/2 Load TB Low Temperature Thermostat
ID Switch display TC Spider wheel earth
IE Water Saving Device TFL Flange earth
IF Switch - Spin Reduction TG Main earth
IP Door switch TH Thermostat
IR Line switch THF Operating thermostat
IS Water-stop THR Adjustable thermostat
I1..2..3.. Switches/switching devices TH1 1st temperature thermostat
L Line or Lamp TH2 2nd temperature thermostat
LB Low Level TH3 3rd temperature thermostat
LN Normal Level TM Motor earth
LS Pilot lamp TMB Main cabinet earth
M Earth-symbol TMP Motor thermal protector
MC Spin cycle motor TMS Thermostop
MI MOTOR WITH PULLEY TP Thermal protector
ML Wash cycle motor TPS Drain pump earth
MO Terminal Board TR Heating element earth
MP Door dip-switch TS Safety thermostat
MR Thermal Lock TT Timer earthing connection
MT Timer motor TTH Earthing Thermostat
MV Motor fan TV Tank earth
MV -Ras Dryer heating element ZBN Timer