Mangueira Aeroquip
Mangueira Aeroquip
Mangueira Aeroquip
Page
302A 44
303 44
1503 43
1529 30
1531 49
1531A 49
1540 55
2550 50
2554 50
2555 49
2556 41
2565 41
2570 50
2575 41
2580 21
2583 22
2651 44
2661 19
2681 23
2766 30
2781 28
2807 65
2808 67
CR170 48
FB9218 42
FB9219 42
FB9220 42
FC136 33
FC186 65
FC194 22
FC195 27
FC211 24
FC212 29
FC234 45
FC252 51
FC254 34
FC273 35
FC300 43
FC310 26
FC318 20
FC321 47
FC323 35
FC324 36
FC325 36
FC332 40
FC350 46
FC352 52
FC355 45
FC363 63
FC364 64
FC372 57
FC373 57
FC374 58
FC375 58
FC376 59
FC377 59
FC414 48
FC465 66
FC466 20
FC469 67
FC498 21
FC505 56
FC510 26
FC555 55
FC558 54
FC563 64
FC579 53
FC606 37
FC611 38
FC616 53
FC619 19
FC636 39
FC639 31
FC645 66
FC647 40
FC650 46
FC659 34
FC690 60
FC693 39
FC699 47
FC701 62
FC702 63
FC735 32
FC736 32
FC802 54
FC901 61
FC902 60
FC914 61
FC916 62
FF9791 42
GH120 31
GH134 56
GH194 23
GH195 27
GH466 38
GH493 33
GH506 37
GH663 24
GH681 25
GH683 25
GH781 28
GH793 29
Part number index
Alphabetical index
Description Page Description Page Description Page
Assembly Instructions 362-376
AQP Hose 16-17
Hose 16-67
Hydraulic 19-38
AQP
22-24
AQP/HI-PAC
26
Double wire braid 27-30, 32, 39
Four heavy spiral wire 32-36
Four or six spiral wire 34-37
HI-IMPULSE
22-24, 27-29, 32
HI-PAC
26
MatchMate Blue
23, 27
MatchMate Ice
31
MatchMate Plus
24, 28-29, 33
Single wire braid 22-25, 38, 43-44
Textile braid 20-22
Wire inserted suction 19-20
Special application 38-67
Air brake 45-46, 50
AQP
261-267
Section Pages
Quick Disconnect
268-345
Couplings
Access., Equipment &
346-393
Assembly Instructions
Technical Data 394-433
RETURN TO CONTENTS PAGE
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
AQP
HOSE
The Aeroquip problem-solving family of AQP
HOSE
H
O
S
E
17
H
O
S
E
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
18
FLUID CONVEYING
PRODUCTS
How to Order
Accurate processing and prompt delivery of your order
depend on easy identification of your requirements. Please
order Aeroquip parts using correct part numbers as
described in this catalog. Inquiries and orders should be
directed to your Aeroquip Distributor or:
Eaton Aeroquip
Industrial Division
3000 Strayer Road, P.O. Box 631
Maumee, Ohio 43537-0631
419/867-2600; Fax: 419/867-2629
www.aeroquip.com
Part numbers and dash sizes
Dash size designates the nominal size in 16ths of an inch.
This number immediately follows the part number and is sep-
arated from it with a dash.
Dimensions
Dimensions given in this catalog for Aeroquip products are
approximate and should be used for reference only. Exact
dimensional information for a given product is subject to
change and varying tolerances; contact Aeroquip directly for
full current information.
Hose assemblies
Aeroquip manufactures the terminal ends of our hose fittings
to the appropriate requirements established by the SAE.
Therefore, the performance ratings of these hose fittings
meet the SAE requirements. It is possible to order a hose
assembly with a fitting terminal end that has a performance
rating lower than the hose rating. When ordering hose
assemblies, please keep the connecting end performance
rating in mind since this may affect overall hose assembly
performance.
Hose assembly components (hose and fittings) are easily
assembled in the field. However, factory assembled reusable
and crimped hose assemblies are available. For complete
information, contact Aeroquip.
Cut length hose
Cut lengths of hose should be ordered as shown below by
specifying lengths in inches.
For numeric part numbers: 2651- 10- 00484
Hose type
Hose size (in 16ths of an inch)
Cut length (in inches)
last digit is in
1
/8ths of an inch 00484 = 48
1
/2 inches
For alpha-numeric part numbers: FC300- 08- 00484
Hose type
Hose dash size
Cut length (in inches)
last digit is in
1
/8ths of an inch 00484 = 48
1
/2 inches
Bulk hose
Bulk hose should be ordered by specifying length in feet as
shown below.
Complete number 500 ft.- 2651- 10
Quantity (in feet)
Hose type
Hose size (in 16ths of an inch)
Note: Length tolerance for hose, assemblies and sleeves is:
Up to and including 12 inches:
1
/8"
Above 12 inches to and including 18 inches:
3
/16"
Above 18 inches to and including 36 inches:
1
/4"
Above 36 inches: 1% of length
H
O
S
E
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
19
2661, FC619
2661
Wire inserted suction
Exceeds SAE 100R4
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
266112 .75 1.25 300 1200 5.00 28 .42
266116 1.00 1.50 250 1000 6.00 28 .50
266120 1.25 1.80 200 800 8.00 28 .90
266124 1.50 2.06 150 600 10.00 28 1.13
266132 2.00 2.55 100 400 12.00 28 1.30
266140 2.50 3.08 62 250 14.00 28 1.72
266148 3.00 3.58 56 225 18.00 28 1.96
266164 4.00 4.69 50 200 24.00 28 3.08
CRIMP FITTINGS
-40 Crimp 143
Global
Skive Nipples 74
OTC 74
TTC 74
TTC12 (-12 only) 74
Sockets 72
Clamps 173
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, reinforcement consisting of a helical wire between two textile braids and blue AQP
elastomer cover.
Application: Suction and transfer applications for petroleum and phosphate ester hydraulic fluids, fuel, lubricating oils,
gasoline, water and many other industrial fluids. For more information on specific fluid applications and high temperature
ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C).
For complete Agency Listings: See pages 397-398.
Maximum working pressure for band clamp type fittings is 50 psi. Sold as bulk hose only.
FC619
Flexible, wire inserted suction
Exceeds SAE100R4
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC619-12 .75 1.21 300 1200 2.50 25 .46
FC619-16 1.00 1.48 250 1000 3.00 25 .56
FC619-20 1.25 1.75 200 800 4.00 25 .78
FC619-24 1.50 2.04 150 600 5.00 25 1.00
FC619-32 2.00 2.55 100 400 6.00 25 1.23
CRIMP FITTINGS
Global
Skive Nipples 74
OTC 74
TTC 74
Sockets 72
Clamps 173
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, reinforcement consisting of a helical wire between two textile reinforcement layers
and synthetic rubber cover.
Application: Suction and transfer applications for petroleum hydraulic fluids, fuel, lubricating oils, gasoline, water and
many other industrial fluids. For more information on specific fluid applications and high temperature ratings, see pages
400-404.
Operating Temperature Range: 40F to +275F (40C to +135C).
For complete Agency Listings: See pages 397-398.
Maximum working pressure for band clamp type fittings is 50 psi.
H
Y
D
R
A
U
L
I
C
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC466-04 .25 .48 400 1600 2.50 28 .06
FC466-06 .38 .62 400 1600 3.00 28 .10
FC466-08 .50 .75 400 1600 4.00 28 .13
FC466-10 .63 .91 350 1400 5.00 18 .18
FC466-12 .75 1.03 350 1400 7.00 18 .19
CRIMP FITTINGS
Global
**Skive Nipples 74
OTC 74
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, textile braid reinforcement and polyester braid cover.
Application: For gasoline, fuel, lubricating oils, air and water. Not approved for air brake applications. For more information
on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C), Air not to exceed +160F (+71C).
For complete Agency Listings: See pages 397-398.
*All sizes except 12
**No skiving required.
FC318
Wire inserted suction
SAE 100R4
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC318-12 .75 1.25 300 1200 5.00 28 .42
FC318-16 1.00 1.50 250 1000 6.00 28 .50
FC318-20 1.25 1.80 200 800 8.00 28 .90
FC318-24 1.50 2.08 150 600 10.00 28 1.13
FC318-32 2.00 2.57 100 400 12.00 28 1.30
FC318-40 2.50 3.07 62 250 14.00 28 1.72
FC318-48 3.00 3.64 56 225 18.00 28 1.96
FC318-64 4.00 4.69 50 200 24.00 28 3.08
CRIMP FITTINGS
-40 Crimp 143
Global
Skive Nipples 74
OTC 74
TTC 74
TTC12 (-12 only) 74
Sockets 72
Clamps 173
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, reinforcement consisting of a helical wire between two textile braids and synthetic
rubber cover.
Application: Suction and transfer applications for petroleum hydraulic fluids, fuel, lubricating oils, gasoline and water. For
more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
Maximum working pressure for band clamp type fittings is 50 psi. Sold as bulk hose only.
FC318, FC466
H
O
S
E
H
Y
D
R
A
U
L
I
C
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
20
FC466
Textile braid
Exceeds SAE 100R6 performance*
FC498
Textile braid
Exceeds SAE 100R6
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC498-04 .25 .50 400 1600 2.50 28 .08
FC498-06 .38 .62 400 1600 3.00 28 .13
FC498-08 .50 .78 400 1600 4.00 28 .15
FC498-10 .63 .91 350 1400 5.00 18 .20
FC498-12 .75 1.03 350 1400 7.00 18 .28
CRIMP FITTINGS
Global
**Skive Nipples 74
OTC 74
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, textile braid reinforcement, AQP elastomer cover.
Application: Low pressure return lines in hydraulic systems. For more information on specific fluid applications and high
temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C).
For complete Agency Listings: See pages 397-398.
**No skiving required.
2580
Double textile braid
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2580-4 .19 .52 1000 4000 3.00 .12
2580-5 .25 .58 800 3200 3.38 .15
2580-6 .31 .68 650 2600 4.00 .17
2580-8 .41 .77 625 2500 4.62 .19
2580-10 .50 .92 600 2400 5.50 .28
2580-12 .63 1.08 550 2200 6.50 .34
2580-16 .88 1.24 500 2000 7.38 .36
2580-20 1.12 1.50 450 1800 9.00 .43
2580-24 1.38 1.75 400 1600 10.50 .51
2580-32 1.81 2.22 350 1400 13.25 .75
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, double textile braid reinforcement and synthetic rubber cover. For larger dash sizes,
see Catalog JD1.
Application: For water, gasoline, and fuel oil. For more information on specific fluid applications and high temperature
ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
H
Y
D
R
A
U
L
I
C
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
21
FC498, 2580
FC194
AQP
/HI-IMPULSE
/HI-IMPULSE
/HI-PAC
wire braid
Exceeds SAE 100R2 performance
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC510-04 .25 .57 5000 20000 3.00 .23
FC510-06 .38 .69 4000 16000 3.50 .29
FC510-08 .50 .80 3500 14000 5.00 .34
FC510-10 .63 .93 2750 11000 6.00 .44
FC510-12 .75 1.09 2250 9000 7.00 .52
FC510-16 1.00 1.37 2000 8000 9.00 .71
FC510-20 1.25 1.70 1625 6500 11.00 1.08
CRIMP FITTINGS
Global
Skive Nipples 74
TTC 74
Sockets 72
REUSABLE FITTINGS 155
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, Hi-Pac braided wire reinforcement and blue AQP elastomer cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, fuel, and lubricating systems.
For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C).
For complete Agency Listings: See pages 397-398.
FC310
HI-PAC
wire braid
SAE 100R16 performance
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC310-04 .25 .55 5000 20000
2.00
.21
FC310-06 .38 .68 4000 16000
2.50
.27
FC310-08 .50 .79 3500 14000
3.50
.34
FC310-10 .63 .93 2750 11000
4.00
.44
FC310-12 .75 1.08 2250 9000
4.75
.50
FC310-16 1.00 1.36 2000 8000
6.00
.71
FC310-20 1.25 1.69 1625 6500
8.25
1.06
CRIMP FITTINGS
Global
Skive Nipples 74
TTC 74
Sockets 72
REUSABLE FITTINGS 155
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, Hi-Pac braided wire reinforcement, synthetic rubber cover.
Application: Hydraulic system service with petroleum and water-base fluids, for general industrial service. For more
specific information on fluid applications, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
Improved minimum bend radius when used with global fittings.
3.00
3.50
5.00
6.00
7.00
9.00
11.00
FC510, FC310
H
O
S
E
H
Y
D
R
A
U
L
I
C
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
26
GH195
AQP
/HI-IMPULSE
/HI-IMPULSE
100,
Sockets 72,
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, 4-heavy spiral wire reinforcement and synthetic rubber cover.
Application: Hydraulic system service with petroleum and water-base fluids, for general industrial use. For more specific
information on fluid applications, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
Rated at 10,000 psi for water blast applications using internal skive fittings.
*Available with Bruiser cover as FC854-08.
FC659
Four spiral wire
Exceeds SAE 100R12
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC659-06 .38 .79 4000 16000 *2.50* .47
FC659-08 .50 .92 4000 16000 *3.50* .57
FC659-10 .63 1.11 4000 16000 *4.75* .70
FC659-12 .75 1.20 4000 16000 *4.75* .90
FC659-16 1.00 1.48 4000 16000 *6.00* 1.21
FC659-20 1.25 1.83 3000 12000 *8.25* 2.40
CRIMP FITTINGS
Global
TTC12 74
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, 4 spiral wire reinforcement and synthetic rubber cover.
Application: Hydraulic system service with petroleum and water-base fluids requiring premium performance and flexibility.
For more specific information on fluid applications, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
*1/2 SAE bend radius.
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC323-12 .75 1.20 3000 12000 9.50 .94
FC323-16 1.00 1.48 3000 12000 12.00 1.22
FC323-20 1.25 1.86 3000 12000 16.50 1.70
FC323-24 1.50 2.11 3000 12000 20.00 2.20
FC323-32 2.00 2.63 3000 12000 25.00 3.21
CRIMP FITTINGS
Spiral Single Skive Crimp
(12 through 24) 108,
Internal Skive Crimp 123,
Sockets 72,
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, 4-spiral wire reinforcement and a blue AQP elastomer cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, fuel, and lubricating systems.
For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C).
For complete Agency Listings: See pages 397-398.
FC273
Four or six spiral wire
SAE 100R13
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC273-12 .75 1.26 5000 20000 9.50 1.08
FC273-16 1.00 1.52 5000 20000 12.00 1.41
FC273-20 1.25 1.96 5000 20000 16.50 2.53
FC273-24 1.50 2.26 5000 20000 20.00 3.35
FC273-32 2.00 2.80 5000 20000 25.00 5.00
CRIMP FITTINGS
Spiral Single Skive Crimp 116,
Internal Skive Crimp 128,
Global
Spiral TTC
100,
Sockets 72,
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, multiple heavy spiral wire (4 wire for -12, -16; 6 wire for -20, -24 and
-32); black synthetic rubber cover.
Application: Hydraulic system service with petroleum and water-base fluids, for general industrial service. For more
information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
FC323
Four spiral wire
Exceeds performance requirements SAE 100R12 (-20), SAE 100R11 (-24, -32)
FC273, FC323
H
O
S
E
H
Y
D
R
A
U
L
I
C
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
35
FC324, FC325
H
O
S
E
H
Y
D
R
A
U
L
I
C
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
36
FC325
Four spiral wire
Exceeds SAE 100R13
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC325-12 .75 1.26 5000 20000 9.50 1.09
FC325-16 1.00 1.52 5000 20000 12.00 1.42
CRIMP FITTINGS
Internal Skive Crimp 130
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, 4-spiral wire reinforcement and a blue AQP elastomer cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, fuel, and lubricating systems.
For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C).
For complete Agency Listings: See pages 397-398.
FC324
Four spiral wire
Exceeds SAE 100R12
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC324-08 .50 .91 4000 16000 7.00 .61
FC324-12 .75 1.20 4000 16000 9.50 .99
FC324-16 1.00 1.48 4000 16000 12.00 1.29
CRIMP FITTINGS
Spiral Single Skive Crimp
(12 & 16 only) 108,
(8 only) 115,
Internal Skive Crimp
(-12, -16) 123,
Sockets 72,
REUSABLE FITTINGS
(8 only) 165,
Sockets 73,
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, 4-spiral wire reinforcement and a blue AQP elastomer cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, fuel, and lubricating systems.
For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C).
For complete Agency Listings: See pages 397-398.
FC606, GH506
H
O
S
E
H
Y
D
R
A
U
L
I
C
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
37
CRIMP FITTINGS
Global Spiral TTC
100
Accessories and Assembly
Instructions see page 346.
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
GH506-12 .75 1.27 6090 24360 11.00 1.43
GH506-16 1.00 1.51 5510 22040 13.38 4.96
GH506-20 1.25 1.79 5075 20300 18.11 5.51
GH506
Four spiral wire
DIN 20023 T2, EN 856 Type 4SH
Construction: Synthetic rubber tube, 4 spiral wire reinforcement, synthetic rubber cover.
Application: Four wire hose for high pressure hydraulic systems with petroleum and water-base fluids. For more information
on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
FC606
Six spiral wire
SAE 100R15
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC606-16 1.00 1.65 6000 24000 12.00 1.79
FC606-20 1.25 1.95 6000 24000 16.50 2.43
FC606-24* 1.50 2.30 6000 24000 20.00 3.17
CRIMP FITTINGS
Internal Skive Crimp 134
Global
Spiral TTC
100
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, 6-spiral wire reinforcement, synthetic rubber cover.
Application: High pressure hydraulics, hydrostatic transmissions. For more information on specific fluid applications and
high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C). FC606-24 -40F to +212F (-40C to +100C).
For complete Agency Listings: See pages 397-398.
*Factory made assemblies only. Contact Eaton Aeroquip.
FC611
Single wire braid medium pressure EPDM hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC611-04 .25 .53 3000 12000 4.00 28 .16
FC611-06 .38 .68 2250 9000 5.00 28 .22
FC611-08 .50 .80 2000 8000 7.00 28 .28
FC611-12 .75 1.10 1250 5000 9.50 28 .43
FC611-16 1.00 1.41 1000 4000 12.00 20 .60
FC611-20 1.25 1.71 625 2500 16.50 20 .80
FC611-24 1.50 1.99 500 2000 20.00 15 1.02
FC611-32 2.00 2.52 375 1500 25.00 15 1.28
CRIMP FITTINGS
Global
TTC 74
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic EPDM tube, single wire braid reinforcement and green EPDM synthetic cover.
Application: Ground support equipment (GSE), industrial phosphate-ester based fluids, water glycol systems. For more
information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +175F (40C to +75C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
38
GH466, FC611
CRIMP FITTINGS
Global Spiral TTC
100
Accessories and Assembly
Instructions see page 346.
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
GH466-20 1.25 1.94 5510 22040 16.50 7.67
GH466
Six spiral wire
Construction: Synthetic rubber tube, 6 spiral wire reinforcement, synthetic rubber cover.
Application: Six wire spiral hose for pressure systems with extreme pressure peaks. For use with petroleum and water-
base fluids. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
FC636
Four spiral wire high pressure EPDM hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC636-12 .75 1.20 4000 16000 9.50 .88
FC636-16 1.00 1.48 4000 16000 12.00 1.17
FC636-20 1.25 1.83 3000 12000 16.50 1.55
FC636-24 1.50 2.12 2500 10000 20.00 1.96
CRIMP FITTINGS
Global
TTC12 74
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic EPDM tube, 4-spiral wire reinforcement, and green EPDM synthetic cover.
Application: Ground support equipment (GSE), industrial phosphate-ester based fluids, water glycol systems. For more
information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +175F (40C to +75C).
For complete Agency Listings: See pages 397-398.
FC693
Double wire braided high pressure EPDM hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC693-04 .25 .60 5000 20000 4.00 .25
FC693-06 .38 .75 4000 16000 5.00 .36
FC693-08 .50 .87 3500 14000 7.00 .40
CRIMP FITTINGS
Global
TTC 74
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic EPDM tube, double wire braid reinforcement and green EPDM synthetic cover.
Application: Ground support equipment (GSE), industrial phosphate-ester based fluids, water glycol systems. For more
information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +175F (40C to +75C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
39
FC693, FC636
FC647
Textile braid low pressure SOCKETLESS
Fire resistant meets RMA/CGA flame test requirements
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC647-04* .25 .52 360 1440 3.00 28 .06
FC647-06* .38 .66 300 1200 3.00 28 .09
FC647-08* .50 .79 300 1200 5.00 28 .12
FC647-10* .63 .92 250 1000 6.00 18 .16
FC647-12* .75 1.05 250 1000 7.00 18 .18
REUSABLE FITTINGS 168
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, textile braid reinforcement, polyester braided cover.
Application: For gasoline, fuel and lubricating oils, air and water. Not recommended for hydraulic impulse applications and
not approved for air brake applications. For more information on specific fluid applications and high temperature ratings,
see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C). Water not to exceed +150F (+66C), air not to
exceed +165F (+74C).
For complete Agency Listings: See pages 397-398.
*NOTE: You must insert the correct color code in the complete part number. Color codes are BLK = black, BLU = blue, BRN = Brown, GRN =
green, WHT = white. Example: FC647-04GRN is a green cover in dash size 4.
FC332
Textile braid
Low pressure SOCKETLESS
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC332-04 .25 .49 250 1000 3.00 28 .08
FC332-06 .38 .63 250 1000 3.00 28 .12
FC332-08 .50 .75 250 1000 5.00 28 .15
FC332-10 .63 .91 250 1000 6.00 18 .20
FC332-12 .75 1.04 250 1000 7.00 18 .28
REUSABLE FITTINGS 168
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, textile braid reinforcement, AQP elastomer cover.
Application: For gasoline, fuel and lubricating oils, air and water. Not recommended for hydraulic impulse applications and
is not approved for air brake applications. For more information on specific fluid applications and high temperature ratings,
see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C). Air not to exceed +250F (+121C) and water not to
exceed +180F (+82C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
40
FC332, FC647
2575
Textile braid color coded
Low pressure SOCKETLESS
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2575-4 .25 .47 250 1000 3.00 .09
2575-6 .38 .62 250 1000 4.00 .13
2575-8 .50 .75 250 1000 5.00 .17
2575-10 .63 .91 200 800 6.00 .20
2575-12 .75 1.03 200 800 7.00 .22
REUSABLE FITTINGS 168
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, textile braid reinforcement, synthetic rubber cover.
Application: For gasoline, fuel and lubricating oils, air and water. Not recommended for hydraulic impulse applications and
is not approved for air brake applications. For more information on specific fluid applications and high temperature ratings,
see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C). Water not to exceed +150F (+66C), air not to
exceed +160F (+71C).
For complete Agency Listings: See pages 397-398.
NOTE: You must insert the correct color code in the complete part number. Color codes are BLK = black, BLU = blue, GRA = gray, GRN =
green, RED = red, YEL = yellow. Example: 2575-4BLU is a blue cover in dash size 4.
2556/2565
Textile braid
Low pressure SOCKETLESS
Meets performance requirements SAE 30R2 Type 1
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2556-4 .25 .49 360 1440 3.00 28 .08
2556-6 .38 .62 300 1200 3.00 28 .14
2556-8 .50 .75 300 1200 5.00 28 .17
2556-10 .63 .91 250 1000 6.00 18 .22
2556-12 .75 1.03 250 1000 7.00 18 .26
2565-4 .25 .50 300 1250 2.25 20 .09
2565-6 .38 .63 250 1000 3.00 20 .12
2565-8 .50 .78 200 750 3.75 10 .17
2565-10 .63 .97 175 700 4.75 10 .39
2565-12 .75 1.09 125 500 5.50 10 .33
REUSABLE FITTINGS 168
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, textile braid reinforcement, synthetic rubber cover.
Application: For gasoline, fuel and lubricating oils, air and water. Not recommended for hydraulic impulse applications and
not approved for air brake applications. For more information on specific fluid applications and high temperature ratings,
see pages 400-404. 2565 is a low temperature synthetic rubber covered MIL-DTL-13444 Type 1, Class A hose.
Operating Temperature Range: 2556: 40F to +212F (40C to +100C). Water not to exceed +150F (+66C), air not
to exceed +160F (+71C). 2565: -65F to +250F (-54C to +121C). Water not to exceed +150F (+66C), air not to
exceed +165F (+74C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
41
2556/2565, 2575
FB9218/FB9219/FB9220
Polyon recoil air hose assemblies
Assembly Male NPT Retracted Rec. Max. Outside
Part Hose Assembly NPT Each Length Work Coil
Number I.D. Length End, Size Nominal Length Dia. Fitting
INCHES FEET INCHES INCHES FEET INCHES SERIES PAGE
FB9218-12 .25 12
1
/4-18 6 10 3
FB9218-25 .25 25
1
/4-18 12 22 3
FB9218-50 .25 50
1
/4-18 23 45 3
FB9219-12 .38 12
3
/8-18 5 10 5
1
/2
FB9219-25 .38 25
3
/8-18 10 21 5
1
/2
FB9219-50 .38 50
3
/8-18 20 42 5
1
/2
FB9220-12 .50 12
1
/2-14 5 9 8
FB9220-25 .50 25
1
/2-14 9 18 8
FB9220-50 .50 50
1
/2-14 18 37 8
Assemblies provided with
fittings attached.
Construction: Red nylon coiled tubing; Male NPT swivel fittings and spring guards at both ends.
Application: Air up to 180 psi maximum all sizes.
Operating Temperature Range: 40F to +180F (40C to +82C).
Note: Aeroquip Polyon recoil air hose swivel assemblies are not recommended or approved for air brake application.
Bulk Hose: Order part number FC341-04 (
1
/4"), FC341-06 (
3
/8"), FC341-08 (
1
/2").
For complete Agency Listings: See pages 397-398.
SAFETY BLOW GUN
1/4" Female NPT Port
Maximum outlet pressure: 30 psi. Conforms to OSHA standards.
Part Number: FF9791-01
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
42
FB9218/FB9219/FB9220
FF9791-01
FC300
Single wire braid
Exceeds SAE 100R5
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC300-04 .19 .52 3000 12000 3.00 28 .13
FC300-05 .25 .58 3000 12000 3.38 28 .16
FC300-06 .31 .67 2250 9000 4.00 28 .23
FC300-08 .41 .76 2000 8000 4.62 28 .26
FC300-10 .50 .93 1750 7000 5.50 28 .37
FC300-12 .63 1.08 1500 6000 6.50 28 .46
FC300-16 .88 1.27 800 3200 7.38 20 .44
FC300-20 1.12 1.50 625 2500 9.00 20 .52
FC300-24 1.38 1.75 500 2000 10.50 15 .67
FC300-32 1.81 2.22 300 1200 13.25 11 .94
FC300-40 2.38 2.88 300 1200 24.00 8 1.50
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, polyester inner braid, single wire braid reinforcement and blue polyester braid cover.
Application: Hydraulics handling petroleum base fluids and air, gasoline, fuel and lubricating oils, fire resistant hydraulic fluids
and other industrial fluids. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 55F to +300F (49C to +150C). Air not to exceed +250F (+121C).
For complete Agency Listings: See pages 397-398.
Maximum negative pressure shown for -16 and larger are suitable for those which has suffered no external damage or kinking. If greater negative
pressures are required for -16 and larger hoses, the use of an internal support coil is recommended.
Does not comply with SAE 100R5 operating pressure of 350 psi or minimum burst of 1400 psi.
1503
Single wire braid
SAE 100R5
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
1503-4 .19 .52 3000 12000 3.00 28 .13
1503-5 .25 .58 3000 12000 3.38 28 .16
1503-6 .31 .68 2250 9000 4.00 28 .23
1503-8 .41 .77 2000 8000 4.62 28 .26
1503-10 .50 .92 1750 7000 5.50 28 .37
1503-12 .63 1.08 1500 6000 6.50 28 .46
1503-16 .88 1.23 800 3200 7.38 20 .44
1503-20 1.12 1.50 625 2500 9.00 20 .52
1503-24 1.38 1.75 500 2000 10.50 15 .67
1503-32 1.81 2.23 350 1400 13.25 11 .94
1503-40 2.38 2.88 350 1400 24.00 11 1.43
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, textile inner braid, single wire braid reinforcement and synthetic rubber impregnated tex-
tile braid cover.
Application: For hydraulics, air, gasoline, fuel and lubricating oils. For more information on specific fluid applications and high
temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C). Air not to exceed +160F (+71C).
For complete Agency Listings: See pages 397-398.
Maximum negative pressures shown for -16 and larger are suitable only for those which has suffered no external damage or kinking. If greater
negative pressures are required for -16 and larger hoses, the use of an internal support coil is recommended.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
43
FC300, 1503
303/302A
Single wire braid
MIL-H-8794
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
303-4 .19 .52 3000 12000 3.00 28 .15
303-5 .25 .58 3000 10000 3.38 28 .19
303-6 .31 .68 2000 9000 4.00 28 .22
303-8 .41 .77 2000 8000 4.62 28 .26
303-10 .50 .92 1750 7000 5.50 28 .36
303-12 .63 1.08 1500 6000 6.50 28 .42
302A16 .88 1.23 800 3200 7.38 28 .39
302A20 1.12 1.50 600 2500 9.00 28 .51
302A24 1.38 1.75 500 2000 11.00 28 .64
302A32 1.81 2.22 350 1400 13.25 28 1.00
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, textile inner braid, single wire braid reinforcement and synthetic rubber impregnated
textile braid cover.
Application: For hydraulics, air, gasoline, fuel and lubricating oils. Air not to exceed +160F (+71C). For more
information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 303 hose: -65F to +250F (-54C to +121C). 302A hose: -40F to +250F (-40C to
+121C).
For complete Agency Listings: See pages 397-398.
2651
Single wire braid
SAE 100R5 performance
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2651-4 .19 .52 3000 12000 3.00 28 .13
2651-5 .25 .58 3000 12000 3.38 28 .16
2651-6 .31 .68 2250 9000 4.00 28 .23
2651-8 .41 .75 2000 8000 4.62 28 .26
2651-10 .50 .92 1750 7000 5.50 28 .37
2651-12 .63 1.08 1500 6000 6.50 28 .46
2651-16 .88 1.23 800 3200 7.38 20 .44
2651-20 1.12 1.50 625 2500 9.00 20 .52
2651-24 1.38 1.75 500 2000 10.50 15 .67
2651-32 1.81 2.22 350 1400 13.25 11 .94
2651-40 2.38 2.88 350 1400 24.00 11 1.43
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, textile inner braid, single wire braid reinforcement, outer textile braid and synthetic
rubber cover.
Application: Hydraulics, gasoline, fuel and lubricating oils, air and water. Air not to exceed 250 psi or +160F (+71C). For
more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
Maximum negative pressures shown for -16 and larger are suitable for hose which has suffered no external damage or kinking. If greater negative
pressures are required for -16 and larger hoses, the use of an internal support coil is recommended.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
44
303/302A, 2651
FC355
Engine & air brake
FMVSS106
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC355-04 .19 .52 1500 6000 .75 28 .17
FC355-05 .25 .58 1500 6000 1.00 28 .20
FC355-06 .31 .68 1500 6000 1.25 28 .24
FC355-08 .41 .77 1250 5000 1.75 28 .29
FC355-10 .50 .94 1250 5000 2.25 28 .40
FC355-12 .63 1.08 750 3000 2.75 20 .46
FC355-16 .88 1.24 400 1600 3.50 15 .50
FC355-20 1.13 1.52 300 1250 4.50 15 .59
FC355-24 1.38 1.75 250 1000 5.50 11 .69
FC355-32 1.81 2.22 200 800 8.50 11 .93
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, polyester inner braid and a single wire braid reinforcement, blue AQP elastomer
cover.
Application: Air, gasoline, fuel, lubricating oils and coolants. For more information on specific fluid applications and high
temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C). Air not to exceed 250 psi or +250F (+121C).
For complete Agency Listings: See pages 397-398.
FC234
Fuel and oil
Fire resistant USCG/MMT, NMMA/BIA
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC234-05 .25 .58 1500 6000 1.00 28 .22
FC234-06 .31 .68 1500 6000 1.25 28 .25
FC234-08 .41 .76 1250 5000 1.75 28 .30
FC234-10 .50 .94 1250 5000 2.25 28 .45
FC234-12 .63 1.08 750 3000 2.75 20 .48
FC234-16 .88 1.24 400 1600 3.50 16 .51
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, brass plated steel wire reinforcement, braided refractory insulation and blue AQP
elastomer cover.
Application: Diesel fuel, gasoline, hot lube oil and water. For more information on specific fluid applications and high
temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +300F (40C to +150C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
45
FC234, FC355
FC350
Engine & air brake
FMVSS106
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC350-04 .19 .52 2000 8000 .75 28 .12
FC350-05 .25 .58 1500 6000 1.00 28 .15
FC350-06 .31 .68 1500 6000 1.25 28 .20
FC350-08 .41 .77 1250 5000 1.75 28 .22
FC350-10 .50 .94 1250 5000 2.25 28 .32
FC350-12 .63 1.08 750 3000 2.75 20 .39
FC350-16 .88 1.23 400 1600 3.50 15 .38
FC350-20 1.12 1.50 300 1200 4.50 15 .45
FC350-24 1.38 1.75 250 1000 5.50 11 .54
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, polyester inner braid and a single wire braid reinforcement; black polyester textile
braided cover.
Application: Air, gasoline, fuel lubricating oils and coolants. For more information on specific fluid applications and high
temperature ratings, see pages 400-404.
Operating Temperature Range: 55F to +300F (49C to +150C). Air not to exceed +250F (+121C).
For complete Agency Listings: See pages 397-398.
FC650
High temperature fuel & oil
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC650-04 .19 .48 1000 4000 .75 28 .10
FC650-06 .31 .63 1000 4000 1.25 28 .15
FC650-08 .41 .74 1000 4000 1.75 28 .19
FC650-10 .50 .83 1000 4000 2.25 28 .23
FC650-12 .63 .99 1000 4000 2.75 20 .28
CRIMP FITTINGS
Contact Aeroquip for fitting
information.
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, single wire braid reinforcement, black polyester braided cover.
Application: Diesel fuel, gasoline, fuel, lubricating oils, water, coolant and air. Not approved for air brake applications.
For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 55F to +300F (49C to +150C). Air not to exceed +250F (+121C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
46
FC350, FC650
FC321
LPG UL listing MH6044
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC321-04 .19 .52 350 1750 1.50 .11
FC321-05 .25 .58 350 1750 1.75 .13
FC321-06 .31 .67 350 1750 2.00 .18
FC321-08 .41 .77 350 1750 2.31 .21
FC321-10 .50 .92 350 1750 2.75 .29
FC321-12 .63 1.08 350 1750 3.25 .37
FC321-16 .88 1.24 350 1750 3.69 .38
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, a textile inner braid, a stainless steel wire braid reinforcement and a synthetic rub-
ber impregnated textile braid cover.
Application: Designed for butane-propane applications on either mobile or stationary equipment. For more information
on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
WARNING: LPG is a very hazardous liquid or gas and should be handled with maximum care to prevent leakage. Since
the gas is heavier than air, it may flow along the ground if it escapes and cause an explosion or a fire. No leakage
should ever be tolerated.
FC699
High temperature fuel hose
AQP lightweight engine hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC699-04 .25 .49 400 1600 2.50 28 .06
FC699-06 .38 .63 400 1600 3.00 28 .10
FC699-08 .50 .77 400 1600 4.00 28 .13
FC699-10 .63 .94 350 1400 5.00 18 .18
FC699-12 .75 1.08 350 1400 7.00 18 .20
CRIMP FITTINGS
Global
OTC 74
Accessories and Assembly
Instructions see page 346.
Construction: AQP elastomer tube, single Kevlar reinforcement braid and textile braided cover.
Application: Diesel fuel, gasoline, crude and lubricating oils.
Operating Temperature Range: 40F to +300F (40C to +150C). Air not to exceed +250F (+121C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
47
FC699, FC321
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
48
CR170, FC414
FC414
Single wire braid
Pressure washer hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC414-06 .38 .68 5.00 3000 12000 .21
CRIMP FITTINGS
Global
TTC 74
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, single wire braid reinforcement and synthetic rubber cover.
Application: Pressure washer machines with working pressures up to 3000 psi. For more information on specific fluid
applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
WARNING: NOT FOR STEAM USE
CR170
Single stainless steel braid LPG hose
CGA (Canadian Gas Association) Type III
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
CR170-04 .19 .52 350 12000 3.00 .16
CR170-06 .31 .67 350 9000 4.00 .22
CR170-08 .41 .77 350 8000 4.62 .26
CRIMP FITTINGS
Contact Aeroquip for fitting
information
Accessories and Assembly
Instructions see page 346.
Construction: Nylon tube, single stainless steel braid reinforcement, perforated synthetic rubber cover.
Application: LPG (propane) vehicle, alternative fuel conversion systems. For more information on specific fluid
applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
2555
Power steering
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2555-6 .38 .76 1125 4500 4.00 .20
REUSABLE FITTINGS 172
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, double textile braid reinforcement and synthetic rubber cover.
Application: Power steering applications. For more information on specific fluid applications and high temperature
ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
1531/1531A
Railroad air brake
Exceeds AAR-M618
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
1531-10 .50 .94 300 1200 5.50 .38
1531-12 .63 1.12 300 1200 6.50 .48
1531-16 .88 1.38 300 1200 7.38 .72
1531-20 1.13 1.63 300 1200 9.50 .78
1531A-24 1.38 1.88 300 1200 10.50 1.04
REUSABLE FITTINGS 173
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, partial textile braid, wire reinforcement (1531-10 and 1531-12 have single wire
braid; 1531-16, 1531-20 and 1531A-24 have double wire braid) and synthetic rubber cover.
Application: Locomotive air brake lines. For more information on specific fluid applications and high temperature
ratings, see pages 400-404.
Operating Temperature Range: 65F to +212F (54C to +100C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
49
2555,1531/1531A
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
50
2550/2554, 2570
2550/2554
Air brake
SAE J1402 FMVSS106
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2550-6 .38 .75 225 900 1.75 .20
2554-6 .38 .75 225 900 3.75 .18
REUSABLE FITTINGS 172
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, double textile braids and synthetic rubber cover.
Application: Tractor to trailer lines, axle chamber lines and tractor service lines. For more information on specific fluid
applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 2550: -40F to +200F (-40C to +93C). 2554: -65F to +212F (-54C to 100C),
conforms to ordinance spec. MIL-H-3992B, Type 1, Class 1.
For complete Agency Listings: See pages 397-398.
2570
Air brake SAE J1402
FMVSS106
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2570-6 .38 .75 225 900 1.75 .18
2570-8 .50 .88 225 900 2.00 .23
2570-10 .62 1.06 225 900 2.25 .30
REUSABLE FITTINGS 172
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, double textile braid and synthetic rubber cover.
Application: Tractor to trailer lines, axle chamber lines and tractor service lines. For more information on specific fluid
applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
Crimp Fittings only, contact Eaton Aeroquip.
REUSABLE FITTINGS
Clamps 173
Accessories and Assembly
Instructions see page 346.
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC252-08 .50 .81 50 200 2.00 .18
FC252-10 .63 .94 40 160 2.50 .19
FC252-12 .75 1.06 40 160 3.00 .28
FC252-16 1.00 1.34 35 140 4.00 .36
FC252
Silicone rubber (heater)
Construction: Silicone rubber tube, braided fiber reinforcement and silicone rubber cover.
Application: Heater hose for passenger cars and trucks; connecting lines from hot water heaters to coolant-circulating
systems. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 65F to +350F (54C to +177C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
51
FC252
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
52
FC352
FC352
Silicone rubber (coolant)
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC352-08 .50 .94 100 425 .17
FC352-10 .63 1.06 100 425 .22
FC352-12 .75 1.19 100 425 .27
FC352-14 .88 1.32 100 425 .31
FC352-16 1.00 1.44 90 375 .34
FC352-18 1.12 1.56 90 375 .41
FC352-20 1.25 1.69 85 350 .45
FC352-22 1.38 1.82 85 350 .50
FC352-24 1.50 1.94 85 350 .55
FC352-26 1.63 2.06 80 325 .58
FC352-28 1.75 2.19 80 325 .63
FC352-32 2.00 2.44 75 300 .72
FC352-36 2.25 2.69 75 300 .81
FC352-38 2.38 2.82 60 250 .84
FC352-40 2.50 2.94 60 250 .89
FC352-44 2.75 3.19 50 200 .98
FC352-48 3.00 3.44 50 200 1.06
FC352-56 3.50 3.94 40 175 1.25
FC352-64 4.00 4.44 35 150 1.44
REUSABLE FITTINGS
Clamps 173
Accessories and Assembly
Instructions see page 346.
Construction: Silicone rubber tube, four spirals of nylon and silicone rubber cover.
Application: Coolant system service with liquid-cooled engines. For more information on specific fluid applications and
high temperature ratings, see pages 400-404.
Operating Temperature Range: 65F to +350F (54C to +177C).
For complete Agency Listings: See pages 397-398.
FC579, FC616
FC579
Jack Hose approved for 10,000 psi
Static jacking applications
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC579-04 .25 .53 10000 20000 2.00 .22
CRIMP FITTINGS
Global
Skive Nipples 74
TTC 74
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, double wire braid reinforcement and synthetic rubber cover.
Application: Hydraulic jacking system service with petroleum and water-base fluids. Meets the performance require-
ments of the Material Handling Institute Specification IJ100. For more information on specific fluid applications and high
temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +212F (40C to +100C).
For complete Agency Listings: See pages 397-398.
FC616
Jack Hose approved for 10,000 psi
Static jacking applications
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC616-06 .38 .79 10000 20000 5.00 .47
CRIMP FITTINGS
Global
TTC12 74
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, four-wire spiral reinforcement and synthetic rubber cover.
Application: Hydraulic jacking system service with petroleum and water-base fluids. Meets the performance require-
ments of the Material Handling Institute Specification IJ100. For more information on specific fluid applications and high
temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
53
FC802
Multi-Refrigerant hose
SAE J51 Type D
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service* Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC802-04 .20 .52 500 2500 2.00 25* .11
FC802-06 .33 .68 500 2500 2.50 25* .16
FC802-08 .42 .77 500 2500 3.00 25* .18
FC802-10 .52 .92 500 2500 3.50 25* .29
FC802-12 .65 1.08 500 2500 4.50 25* .35
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Bromobutyl cover, polyamide-veneer tube, synthetic braid reinforcement, synthetic rubber backing layer.
Application: Transportation, refrigeration and air conditioning systems using Refrigerant 12, R-22, R-134a, R-502. For
more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
*All sizes of FC802 will withstand full negative pressure for charging purposes and are suitable for very short term service at full negative
pressure.
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC558-10 .50 .92 500 2500 5.50 28 .33
FC558-12 .63 1.06 500 2500 6.50 28 .41
FC558-16 .88 1.24 500 2500 7.38 28 .47
FC558-20 1.12 1.51 500 2500 9.00 28 .57
FC558-24 1.38 1.75 500 2500 10.50 28 .69
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Butyl rubber tube, single wire braid reinforcement and textile braid cover.
Application: Designed for applications using only refrigerant 134a. Not recommended for applications using Refrigerant
12 or R22. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +250F (40C to +121C).
For complete Agency Listings: See pages 397-398.
FC558
Refrigeration/air conditioning SAE J2064
Type B Class 1
FC558, FC802
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
54
FC555
Refrigeration/air conditioning
Multi-refrigerant
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius *Service* Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC555-12 .63 1.12 500 2500 2.50 29.5 .20
FC555-16 .88 1.38 500 2500 3.00 29.5 .25
FC555-20 1.12 1.65 500 2500 4.00 29.5 .33
CRIMP FITTINGS
Refer to Catalog JA466
Accessories and Assembly
Instructions see page 346.
Construction: Corrugated nylon tube, stabilized synthetic braid reinforcement and abrasion-resistant polyester braided
cover.
Application: Transportation refrigeration and air conditioning systems using R-134a, R-12, R-22 or R-502 (contact
Eaton Aeroquip for additional refrigerants). See pages 400-404.
Operating Temperature Range: 22F to +257F (30C to +125C).
For complete Agency Listings: See pages 397-398.
*All sizes will withstand full negative pressure for charging purposes.
1540
Refrigeration/air conditioning
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius *Service* Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
1540-4 .19 .50 350 1750 3.00 28 .12
1540-6 .31 .67 350 1750 4.00 28 .18
1540-8 .41 .75 350 1750 4.62 28 .23
1540-10 .50 .92 350 1750 5.50 28 .32
1540-12 .63 1.06 350 1750 6.50 28 .45
1540-16 .88 1.24 350 1750 7.38 28 .45
1540-20 1.12 1.50 350 1750 9.00 28 .57
1540-24 1.38 1.75 350 1750 10.50 28 .69
REUSABLE FITTINGS 145
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Synthetic rubber tube, single wire braid reinforcement and black textile braided cover.
Application: Designed for applications using Refrigerant 12. Not recommended for applications using Freon 22 or
R-502. See pages 400-404.
Operating Temperature Range: 20F to +250F (29C to +121C).
For complete Agency Listings: See pages 397-398.
*All sizes will withstand full negative pressure for charging purposes.
1540, FC555
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
55
FC505
Refrigeration/air conditioning
SAE J2064 Type E Class 1, Multi-refrigerant
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius *Service* Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC505-04 .20 .44 500 2500 1.50 29.5 .07
FC505-06 .32 .59 500 2500 2.00 29.5 .10
FC505-08 .42 .71 500 2500 2.50 29.5 .12
FC505-10 .52 .79 500 2500 3.00 29.5 .14
FC505-12 .64 .98 500 2500 4.00 29.5 .22
CRIMP FITTINGS
Refer to Catalog JA466
Accessories and Assembly
Instructions see page 346.
Construction: Nylon veneer tube, stabilized synthetic braided reinforcement and chlorobutyl rubber cover.
Application: Transportation refrigeration and air conditioning systems using R-134a, R-12, R-22 or R-502 (contact
Eaton Aeroquip for additional refrigerants). For more information on specific fluid applications and high temperature
ratings, see pages 400-404.
Operating Temperature Range: 40F to +275F (40C to +135C).
For complete Agency Listings: See pages 397-398.
*All sizes will withstand full negative pressure for charging purposes.
GH134
Refrigeration/air conditioning
SAE J2064 Type E Class 1, Multi-refrigerant
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius *Service* Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
GH134-6 .31 .58 500 2500 2.00 29.5 .09
GH134-8 .41 .70 500 2500 2.50 29.5 .12
GH134-10 .50 .78 500 2500 3.00 29.5 .15
GH134-12 .63 .98 500 2500 4.00 29.5 .18
CRIMP FITTINGS
Refer to Catalog JA466
Accessories and Assembly
Instructions see page 346.
Construction: Nylon veneer tube, stabilized synthetic braided reinforcement and chlorobutyl rubber cover.
Application: Transportation refrigeration and air conditioning systems using R-134a, R12, R22, R404 and R407. For
more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 40F to +257F (40C to +135C).
For complete Agency Listings: See pages 397-398.
*All sizes will withstand full negative pressure for charging purposes.
GH134, FC505
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
56
FC373
Polyon/Thermoplastic
SAE 100R7 Nonconductive
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC373-02 .13 .33 2500 10000 .50 .05
FC373-03 .19 .44 3000 12000 .75 .06
FC373-04 .25 .53 2750 11000 1.25 .08
FC373-05 .31 .59 2500 10000 1.75 .09
FC373-06 .38 .66 2250 9000 2.00 .10
FC373-08 .50 .83 2000 8000 3.00 .16
FC373-12 .75 1.07 1250 5000 5.00 .22
FC373-16 1.00 1.32 1000 4000 8.00 .27
SWAGE/CRIMP 135
CRIMP FITTINGS
Global
**Skive Nipples 74
Sockets 72
REUSABLE FITTINGS 153
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Thermoplastic elastomer tube, single braid polyester reinforcement and an orange nonperforated
polyurethane cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, fuel, and lubricating
systems. For more information on specific fluid applications and high temperature ratings, see pages 400-404. For non-
conductivity information see item 8 on page 408.
Operating Temperature Range: 65F to +200 (54C to +93C). Water not to exceed +150F (+66C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (-40C to +93C) for flexing applications.
**Skiving not required.
FC372
Polyon/Thermoplastic
SAE 100R7
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC372-02 .13 .33 2500 10000 .50 .05
FC372-03 .19 .44 3000 12000 .75 .06
FC372-04 .25 .53 2750 11000 1.25 .09
FC372-05 .31 .59 2500 10000 1.75 .10
FC372-06 .38 .66 2250 9000 2.00 .12
FC372-08 .50 .83 2000 8000 3.00 .17
FC372-10 .63 .94 1500 6000 4.00 .19
FC372-12 .75 1.07 1250 5000 5.00 .22
FC372-16 1.00 1.32 1000 4000 8.00 .28
SWAGE/CRIMP 135
CRIMP FITTINGS
Global
**Skive Nipples 74
Sockets 72
REUSABLE FITTINGS 153
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Thermoplastic elastomer tube, single braid polyester reinforcement and a black perforated polyurethane
cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, pneumatic, fuel, and
lubricating systems. For more information on specified fluid applications and high temperature ranges, see pages
400-404.
Operating Temperature Range: 65F to +200F (54C to +93C). Water not to exceed +150F (+66C) air not to
exceed +160F (+71C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (-40C to +93C) for flexing applications. **No skiving of cover required.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
57
FC372, FC373
FC375
Polyon/Thermoplastic
SAE 100R8 Nonconductive
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC375-03 .19 .41 5000 20000 1.50 .05
FC375-04 .25 .51 5000 20000 2.00 .07
FC375-06 .38 .66 4000 16000 2.50 .11
FC375-08 .50 .81 3500 14000 4.00 .14
FC375-12 .75 1.06 2250 9000 8.00 .22
FC375-16 1.00 1.37 2000 8000 10.00 .27
SWAGE/CRIMP 135
Accessories and Assembly
Instructions see page 346.
Construction: Thermoplastic elastomer tube, single braid aramid reinforcement and an orange nonperforated
polyurethane cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, fuel, and lubricating
systems. For more information on specific fluid applications and high temperature ratings, see pages 400-404. For
nonconductivity information, see item 8 page 408.
Operating Temperature Range: 65F to +200F (54C to +93C). Water not to exceed +150F (+66C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (-40C to +93C) for flexing applications.
FC374
Polyon/Thermoplastic
SAE 100R8
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC374-03 .19 .40 5000 20000 1.50 .05
FC374-04 .25 .51 5000 20000 2.00 .08
FC374-06 .38 .66 4000 16000 2.50 .12
FC374-08 .50 .81 3500 14000 4.00 .16
FC374-12 .75 1.08 2250 9000 8.00 .23
FC374-16 1.00 1.32 2000 8000 10.00 .27
SWAGE/CRIMP 135
Accessories and Assembly
Instructions see page 346.
Construction: Thermoplastic elastomer tube, single braid aramid reinforcement and a black perforated polyurethane
cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, pneumatic, fuel, and
lubricating systems. For more information on specific fluid applications and high temperature ratings, see pages
400-404.
Operating Temperature Range: 65F to +200F (54C to +93C). Water not to exceed +150F (+66C), air not to
exceed +160F (+71C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (-40C to +93C) for flexing applications.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
58
FC374, FC375
FC377
Polyon/Thermoplastic
Nonconductive, ultra high pressure
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC377-03 .19 .50 10000 40000 1.50 .08
FC377-04 .25 .63 10000 35000 2.50 .13
CRIMP FITTINGS
Contact Eaton Aeroquip for
fitting information
Accessories and Assembly
Instructions see page 346.
Construction: Thermoplastic elastomer tube, double braid aramid reinforcement and orange nonperforated
polyurethane cover.
Application: Hydraulic system service with petroleum, and water-base fluids, for general industrial service. For more
information on specific fluid applications and high temperature ratings, see pages 400-404. For nonconductivity
information, see item 8 on page 408.
Operating Temperature Range: 40F to +150F (40C to +66C).
For complete Agency Listings: See pages 397-398.
CAUTION: Applies only to hose that has suffered no damage, has been properly assembled with hose guards, and tested to required test
pressure.
WARNING: The use of this hose in high pressure application
requires the use of undamaged hose which has been properly
assembled with hose guards and tested to the required pressure.
Installations must not exceed the recommended minimum bend radius. The
failure to follow these instructions may result in sudden hose failure with the
potential for serious personal injury and property damage.
FC376
Polyon/Thermoplastic
Ultra high pressure
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC376-03 .19 .50 10000 40000 1.50 .09
FC376-04 .25 .63 10000 35000 2.50 .13
CRIMP FITTINGS
Contact Eaton Aeroquip for
fitting information
Accessories and Assembly
Instructions see page 346.
Construction: Thermoplastic elastomer tube, double braid aramid reinforcement and a black perforated polyurethane
cover.
Application: High pressure hydraulic system service with petroleum, fire-resistant, and water-base fluids, pneumatic
and lubricating systems. For more information on specific fluid applications and high temperature ratings, see pages
400-404.
Operating Temperature Range: 40F to +150F (-40C to +66C).
For complete Agency Listings: See pages 397-398.
CAUTION: Applies only to hose that has suffered no damage, has been properly assembled with hose guards, and tested to required test
pressure.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
59
FC376, FC377
WARNING: The use of this hose in high pressure application
requires the use of undamaged hose which has been properly
assembled with hose guards and tested to the required pressure.
Installations must not exceed the recommended minimum bend radius. The
failure to follow these instructions may result in sudden hose failure with the
potential for serious personal injury and property damage.
Construction: Two Aeroquip SAE 100R7 thermoplastic hoses permanently joined.
Application: Hydraulic system service with petroleum, fire-resistant and water-base fluids, pneumatic, fuel, and
lubricating systems. For more information on specified applications and high temperature ranges, see pages 400-404.
Operating Temperature Range: -65F to +200F (-54C to +93C). Water not to exceed +150F (+66C) air not to
exceed +160F (+71C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (40C to +93C) for flexing applications.
**No skiving of cover needed.
FC902
Polyon/Thermoplastic Twin-line
SAE 100R7
Number Hose Polyon
Part Number of Hoses I.D. Hose Series
INCHES FITTING REFERENCE PAGE
FC902-00-Length Designation 2 0.19 FC372-03
FC902-01-Length Designation 2 0.25 FC372-04
FC902-02-Length Designation 2 0.31 FC372-05
FC902-03-Length Designation 2 0.38 FC372-06
FC902-04-Length Designation 2 0.50 FC372-08
FC902-05-Length Designation 2 0.75 FC372-12
FC902-06-Length Designation 2 1.00 FC372-16
SWAGE/CRIMP
Swage 135
Crimp**
Skive Nipples 74
Sockets 72
REUSABLE FITTINGS 153
Sockets 73
Accessories and Assembly
Instructions see page 346.
FC690
Polyon/Thermoplastic
Low temperature flexing SAE 100R7
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC690-04RL .25 .53 2750 11000 1.25 .09
FC690-06RL .38 .66 2500 10000 2.50 .11
FC690-08RL .50 .84 2500 10000 3.50 .18
SWAGE 135
Accessories and Assembly
Instructions see page 346.
Construction: Thermoplastic elastomer tube, double braid polyester reinforcement and low temperature black, perforated
polyurethane cover.
Application: Hydraulic system service with petroleum, fire-resistant, and water-base fluids, pneumatic, fuel, and
lubricating systems utilized in continuous low temperature flexing applications. For more information on specified fluid
applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 65F to +200F (54C to +93C). Water not to exceed +150F (+66C), air not to
exceed +160F (+71C). Sold in reel lengths only.
For complete Agency Listings: See pages 397-398.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
60
FC690, FC902
FC901
Polyon/Thermoplastic Twin-line
SAE 100R7 Nonconductive
Number Hose Polyon
Part Number of Hoses I.D. Hose Series
INCHES FITTING REFERENCE PAGE
FC901-00-Length Designation 2 0.19 FC373-03
FC901-01-Length Designation 2 0.25 FC373-04
FC901-02-Length Designation 2 0.31 FC373-05
FC901-03-Length Designation 2 0.38 FC373-06
FC901-04-Length Designation 2 0.50 FC373-08
FC901-05-Length Designation 2 0.75 FC373-12
FC901-06-Length Designation 2 1.00 FC373-16
SWAGE/CRIMP
Swage 135
Crimp**
Skive Nipples 74
Sockets 72
REUSABLE FITTINGS 153
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Two Aeroquip SAE 100R7 Nonconductive thermoplastic hoses permanently joined.
Application: Hydraulic system service with petroleum, fire-resistant and water-base fluids, fuel, and lubricating systems.
For more information on specific fluid applications and high temperature ratings, see pages 400-404. For nonconductivity
information see item 8 on page 408.
Operating Temperature Range: -65F to +200 (-54C to +93C). Water not to exceed +150F (+66C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (-40C to +93C) for flexing applications.
**No skiving of cover needed.
Construction: Two Aeroquip SAE 100R8 thermoplastic hoses permanently joined.
Application: Hydraulic system service with petroleum, fire-resistant and water-base fluids, pneumatic, fuel, and
lubricating systems. For more information on specific fluid applications and high temperature ratings, see pages
400-404.
Operating Temperature Range: -65F to +200F (-54C to +93C). Water not to exceed +150F (+66C), air not to
exceed +160F (+71C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (-40C to +93C) for flexing applications.
FC914
Polyon/Thermoplastic Twin-line
SAE 100R8
Number Hose Polyon
Part Number of Hoses I.D. Hose Series
INCHES FITTING REFERENCE PAGE
FC914-00-Length Designation 2 0.19 FC374-03
FC914-01-Length Designation 2 0.25 FC374-04
FC914-03-Length Designation 2 0.38 FC374-06
FC914-04-Length Designation 2 0.50 FC374-08
FC914-05-Length Designation 2 0.75 FC374-12
FC914-06-Length Designation 2 1.00 FC374-16
SWAGE/CRIMP 135
Accessories and Assembly
Instructions see page 346.
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
61
FC901, FC914
Construction: Two Aeroquip SAE 100R8 thermoplastic nonconductive hoses permanently joined.
Application: Hydraulic system service with petroleum, fire-resistant and water-base fluids, fuel and lubricating systems.
For more information on specific fluid applications and high temperature ratings, see pages 400-404. For nonconductivi-
ty information, see item 8 page 408.
Operating Temperature Range: -65F to +200F (-54C to +93C). Water not to exceed +150F (+66C).
For complete Agency Listings: See pages 397-398.
-40F to +200F (-40C to +93C) for flexing applications.
Important: Cut lengths of twin-line hoses should be ordered as shown below by specifying the length in inches:
Example: FC902-00-00484
Hose Type Cut Length (in inches) last digit is in 1/8ths of an inch 00484=48
1
/
2
inches
Aeroquip hose part #'s FC372, FC373, FC374, FC375, FC376 and FC377 can be permanently joined to form twin-line or multi-line hose designs. The above
twin-line part #'s are the typical standard designs. If you would like to mate multiple pressure hoses in one design, please contact Eaton Aeroquip.
FC916
Polyon/Thermoplastic Twin-line
SAE 100R8 Nonconductive
Number Hose Polyon
Part Number of Hoses I.D. Hose Series
INCHES FITTING REFERENCE PAGE
FC916-00-Length Designation 2 0.19 FC375-03
FC916-01-Length Designation 2 0.25 FC375-04
FC916-03-Length Designation 2 0.38 FC375-06
FC916-04-Length Designation 2 0.50 FC375-08
FC916-05-Length Designation 2 0.75 FC375-12
FC916-06-Length Designation 2 1.00 FC375-16
SWAGE/CRIMP 135
Accessories and Assembly
Instructions see page 346.
FC701
Sewer cleaning hose
assemblies Gator hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC701-12 .75 1.15 2500 6250 9.50 .27
FC701-16 1.01 1.41 2500 6250 12.00 .36
FC701-20 1.26 1.79 2500 6250 12.00 .58
SWAGE 139
Accessories and Assembly
Instructions see page 346.
Construction: Blue thermoplastic tube, single braid, polyester reinforcement and an orange ether-based polyurethane
cover.
Application: High pressure sewer cleaning. For more information on specified applications and high temperature
ranges, see pages 400-404.
Operating Temperature Range: 40F to +150F (40C to +66C).
For complete Agency Listings: See pages 397-398.
FC916, FC701
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
62
FC363
Convoluted PTFE hose
Nonconductive tube
Maximum Minimum Minimum Minimum
Part Hose Hose Operating Burst Bend Kink Vacuum
Number I.D. O.D. Pressure Pressure Radius Radius Service
INCHES INCHES PSI PSI INCHES INCHES INCH/Hg FITTING REFERENCE PAGE
FC363-08 .54 .74 1250 5000 2.88 1.00 28
FC363-12 .81 1.06 1100 4400 3.75 2.00 28
FC363-16 1.00 1.28 1000 4000 5.00 2.50 24
FC363-20 1.24 1.53 1000 4000 6.25 3.50 20
FC363-24 1.52 1.81 750 3000 7.50 4.50 12
FC363-32 2.00 2.31 500 2000 10.00 6.00 5
CRIMP FITTINGS
Crimp 142
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: Convoluted PTFE tube with stainless steel single wire braid cover.
Application: Chemical, food, water and waste handling, and various transfer applications. Not recommended for steam-
cold water cycling. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 65F to +400F (54C to +204C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements, contact Eaton Aeroquip.
FC702, FC363
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
63
FC702
Sewer cleaning hose
assemblies Gator hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC702-12 .75 1.19 3000 7500 9.50 .29
FC702-16 1.01 1.41 3000 7500 12.00 .36
SWAGE 139
Accessories and Assembly
Instructions see page 346.
Construction: Blue thermoplastic elastomer tube, single braid, high strength textile reinforcement and a blue
ether-based polyurethane cover.
Application: High pressure sewer cleaning. For more information on specific applications and high temperature ranges,
see pages 400-404.
Operating Temperature Range: 40F to +150F (40C to +66C).
For complete Agency Listings: See pages 397-398.
Maximum Minimum Minimum Minimum
Part Hose Hose Operating Burst Bend Kink Vacuum
Number I.D. O.D. Pressure Pressure Radius Radius Service
INCHES INCHES PSI PSI INCHES INCHES INCH/Hg FITTING REFERENCE PAGE
FC364-08 .54 .74 1250 5000 2.88 1.00 28
FC364-12 .81 1.06 1100 4400 3.75 2.00 28
FC364-16 1.00 1.27 1000 4000 5.00 2.50 24
FC364-20 1.24 1.53 1000 4000 6.25 3.50 20
FC364-24 1.52 1.81 750 3000 7.50 4.50 12
FC364-32 2.00 2.31 500 2000 10.00 6.00 5
FC364-40 2.53 2.90 100 400 12.50 8.00 5
FC364-48 3.04 3.48 100 400 15.00
CRIMP FITTINGS
Crimp 142
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: Convoluted conductive PTFE tube with stainless steel wire braid cover.
Application: Steam lines and fuel transfer applications where static dissipation is required. Not recommended for
steam-cold water cycling. For more information on specific fluid applications and high temperature ratings, see pages
400-404.
Operating Temperature Range: 65F to +400F (54C to +204C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements, contact Eaton Aeroquip.
FC364
Convoluted PTFE hose
Conductive
FC563
Convoluted PTFE hose
Nonconductive tube
Maximum Minimum Minimum Minimum
Part Hose Hose Operating Burst Bend Kink Vacuum
Number I.D. O.D. Pressure Pressure Radius Radius Service
INCHES INCHES PSI PSI INCHES INCH/Hg INCH/Hg FITTING REFERENCE PAGE
FC563-08 .54 .74 1250 5000 2.88 1.00 28
FC563-12 .81 1.06 1100 4400 3.75 2.00 28
FC563-16 1.00 1.28 1000 4000 5.00 2.50 24
FC563-20 1.24 1.53 1000 4000 6.25 3.50 20
FC563-24 1.52 1.81 750 3000 7.50 4.50 10
FC563-32 2.00 2.31 500 2000 10.00 6.00 7
CRIMP FITTINGS
Crimp 142
Sockets 72
Accessories and Assembly
Instructions see page 346.
Construction: Convoluted PTFE tube with stainless steel single wire braid reinforcement and integral black polyester
overbraid cover.
Application: Chemical transfer and various chemical processing applications. Not recommended for steam or steam-
cold water cycling. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 65F to +300F (54C to +150C).
For complete Agency Listings: See pages 397-398.
FC364, FC563
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
64
2807
PTFE hose
SAE 100R14A
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2807-3 .14 .25 3000 12000 1.50 28 .04
2807-4 .19 .30 3000 12000 2.00 28 .06
2807-5 .26 .37 3000 12000 3.00 28 .08
2807-6 .32 .43 2500 10000 4.00 28 .10
2807-8 .42 .54 2000 8000 5.25 28 .12
2807-10 .51 .63 1500 6000 6.50 28 .16
2807-12 .64 .76 1200 4800 7.75 28 .18
2807-16 .88 1.03 1000 4000 9.00 12 .26
2807-20 1.12 1.29 625 2500 16.00 12 .34
CRIMP FITTINGS
Crimp 140
Sockets 72
REUSABLE FITTINGS 174
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Extruded PTFE tube with stainless steel single wire braid.
Application: Hot air, steam, compressor discharge and most chemical applications. Not recommended for steam-cold water
cycling. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 100F to +500F (73C to +260C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements. Contact Eaton Aeroquip.
Maximum negative pressure for -06 and larger are suitable for hose which has suffered no external damage or kinking. If greater negative
pressures are required for -06 and larger hoses, the use of an internal support coil is recommended. Use of an internal support coil in -06
and larger PTFE hose is recommended for tube support where extended or continuous service at high temperature together with low or
negative pressure is expected.
FC186
PTFE hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC186-04 .19 .30 1000 6000 2.00 28 .06
FC186-05 .26 .37 1000 6000 3.00 28 .07
FC186-06 .32 .43 1000 6000 4.00 28 .08
FC186-08 .42 .54 750 4500 5.25 28 .10
FC186-10 .51 .63 600 4000 6.50 28 .14
FC186-12 .64 .76 600 4000 7.75 28 .16
CRIMP FITTINGS
Crimp 140
Sockets 72
REUSABLE FITTINGS 174
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Extruded PTFE tube with stainless steel single wire braid.
Application: Hot air, steam, compressor discharge and most chemical applications. Not recommended for steam-cold
water cycling. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 65F to +400F (54C to +204C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements. Contact Eaton Aeroquip.
Maximum negative pressure for -06 and larger are suitable for hose which has suffered no external damage or kinking. If greater negative
pressures are required for -06 and larger hoses, the use of an internal support coil is recommended. Use of an internal support coil in -06
and larger PTFE hose is recommended for tube support where extended or continuous service at high temperature together with low or
negative pressure is expected.
FC186, 2807
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
65
FC645, FC465
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
66
FC645
PTFE hose
Conductive SAE 100R14B performance
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC645-06 .32 .51 2500 10000 4.00 28 .10
CRIMP FITTINGS
Contact Aeroquip for Fitting
Information, Factory Crimp Only
Accessories and Assembly
Instructions see page 346.
Construction: Conductive extruded black PTFE tube with stainless steel single black wire braid abrasion resistant
engine hose.
Application: Steam, compressor discharge and most chemical applications. Not recommended for steam-cold water
cycling. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 100F to +300F (73C to +150C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements. Contact Eaton Aeroquip.
Maximum negative pressure is suitable for hose which has suffered no external damage or kinking. If greater negative pressures are
required, the use of an internal support coil is recommended. Use of an internal support coil in -06 PTFE hose is recommended for tube
support where extended or continuous service at high temperature together with low or negative pressure is expected.
FC465
PTFE hose
Conductive SAE 100R14B
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC465-03 .14 .25 3000 12000 1.50 28 .04
FC465-04 .19 .30 3000 12000 2.00 28 .06
FC465-05 .26 .37 3000 12000 3.00 28 .08
FC465-06 .32 .43 2500 10000 4.00 28 .10
FC465-08 .42 .54 2000 8000 5.25 28 .12
FC465-10 .51 .63 1500 6000 6.50 28 .16
FC465-12 .64 .76 1200 4800 7.75 28 .18
FC465-16 .88 1.03 1000 4000 9.00 12 .26
FC465-20 1.12 1.29 625 2500 16.00 12 .34
CRIMP FITTINGS
Crimp 140
Sockets 72
REUSABLE FITTINGS 174
Sockets 73
Accessories and Assembly
Instructions see page 346.
Construction: Conductive extruded black PTFE tube with stainless steel single wire braid.
Application: Steam, compressor discharge and most chemical applications. Not recommended for steam-cold water
cycling. For more information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 100F to +500F (73C to +260C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements. Contact Eaton Aeroquip.
Maximum negative pressure for -06 and larger are suitable for hose which has suffered no external damage or kinking. If greater negative
pressures are required for -06 and larger hoses, the use of an internal support coil is recommended. Use of an internal support coil in -06
and larger PTFE hose is recommended for tube support where extended or continuous service at high temperature together with low or
negative pressure is expected.
2808
PTFE hose
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
2808-8 .42 .58 2750 11000 4.62 28 .20
2808-10 .51 .68 2500 10000 5.50 28 .26
2808-12 .64 .81 1750 7000 6.50 20 .30
2808-16 .88 1.09 1500 6000 7.38 15 .44
2808-20 1.12 1.35 1125 4500 11.00 15 .57
2808-24 1.38 1.62 800 3200 14.00 15 .70
REUSABLE FITTINGS 175
Sockets 73
Accessories and Assembly
Instructions see page 346.
2808, FC469
H
O
S
E
S
P
E
C
I
A
L
A
P
P
L
I
C
A
T
I
O
N
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product.
67
Construction: Conductive extruded PTFE tube with stainless steel single wire braid.
Application: High pressure chemical and fluid transfer. For information on specific fluid applications and high temperature
ratings, see pages 400-404.
Operating Temperature Range: 65F to +400F (54C to +204C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements. Contact Eaton Aeroquip.
Use of an internal support coil in -06 and larger PTFE hose is recommended for tube support where extended or continuous service at
high temperature together with low or negative pressure is expected.
FC469
PTFE hose
Conductive
Maximum Minimum Minimum
Part Hose Hose Operating Burst Bend Vacuum Weight
Number I.D. O.D. Pressure Pressure Radius Service Per Foot
INCHES INCHES PSI PSI INCHES INCH/Hg POUNDS FITTING REFERENCE PAGE
FC469-06 .30 .48 4000 16000 2.50 28 .17
FC469-08 .39 .61 4000 16000 2.88 28 .24
FC469-10 .49 .72 3500 14000 3.25 28 .29
CRIMP FITTINGS
Contact Aeroquip for fitting
information.
Accessories and Assembly
Instructions see page 346.
Construction: Extruded PTFE tube with double stainless steel braids.
Application: Hot air, steam and most chemical applications. Not recommended for steam-cold water cycling. For more
information on specific fluid applications and high temperature ratings, see pages 400-404.
Operating Temperature Range: 100F to +500F (73C to +260C).
For complete Agency Listings: See pages 397-398.
Steam 200 psi at +388F max. Engineering information is available for specific critical temperature requirements. Contact Eaton Aeroquip.
Maximum negative pressure for -08 and larger are suitable for hose which has suffered no external damage or kinking. If greater negative
pressures are required for -08 and larger hoses, the use of an internal support coil is recommended. Use of an internal support coil in -08
and larger PTFE hose is recommended for tube support where extended or continuous service at high temperature together with low or
negative pressure is expected.
RETURN TO CONTENTS PAGE