This document provides technical specifications for Cat. 6A F/UTP cables with 4 pairs and 2 x 4 twisted pairs made by Legrand. The cables are characterized up to 500 MHz and enable 10G Base-T applications. Key specifications include: maximum attenuation of 45.3 dB/100m; minimum NEXT of 33.8 dB; impedance of 100 ohms; operating temperature range of -20°C to +60°C; fire resistance of IEC 60332-1 and UL VW-1; and compliance with standards including EIA/TIA 568-C.2, EN 50173, and IEC 11801 for Cat. 6A performance up to 500 MHz.
This document provides technical specifications for Cat. 6A F/UTP cables with 4 pairs and 2 x 4 twisted pairs made by Legrand. The cables are characterized up to 500 MHz and enable 10G Base-T applications. Key specifications include: maximum attenuation of 45.3 dB/100m; minimum NEXT of 33.8 dB; impedance of 100 ohms; operating temperature range of -20°C to +60°C; fire resistance of IEC 60332-1 and UL VW-1; and compliance with standards including EIA/TIA 568-C.2, EN 50173, and IEC 11801 for Cat. 6A performance up to 500 MHz.
This document provides technical specifications for Cat. 6A F/UTP cables with 4 pairs and 2 x 4 twisted pairs made by Legrand. The cables are characterized up to 500 MHz and enable 10G Base-T applications. Key specifications include: maximum attenuation of 45.3 dB/100m; minimum NEXT of 33.8 dB; impedance of 100 ohms; operating temperature range of -20°C to +60°C; fire resistance of IEC 60332-1 and UL VW-1; and compliance with standards including EIA/TIA 568-C.2, EN 50173, and IEC 11801 for Cat. 6A performance up to 500 MHz.
This document provides technical specifications for Cat. 6A F/UTP cables with 4 pairs and 2 x 4 twisted pairs made by Legrand. The cables are characterized up to 500 MHz and enable 10G Base-T applications. Key specifications include: maximum attenuation of 45.3 dB/100m; minimum NEXT of 33.8 dB; impedance of 100 ohms; operating temperature range of -20°C to +60°C; fire resistance of IEC 60332-1 and UL VW-1; and compliance with standards including EIA/TIA 568-C.2, EN 50173, and IEC 11801 for Cat. 6A performance up to 500 MHz.
1/2 Technical data sheet: F00989EN/01 Updated on: 03/03/2011 Created on: 28/09/2009 3. MARKING OF LEGRAND CABLES - Legrand - Catalogue number - Number of pairs - Gauge - Type - Impedance - Type of sleeve - Category - Conformity to standards - VPN/NVP - Batch number - Measurement (remaining length) 4. PERFORMANCE AT 500 MHZ (standard EIA/TIA 568-C.2) Maximum attenuation (dB/100 m): ...............45.3 Minimum NEXT (dB): ...................................33.8 PS NEXT (dB): .............................................31.8 ACRF (dB / 100 m): .......................................13.8 PS ACRF (dB / 100 m): .................................10.8 Return Loss (dB): .........................................15.2 1. USE Cat. 6A cables with 4 pairs and 2 x 4 twisted pairs, 100 ohms very high speed, for horizontal floor or backbone distribution. These cables enable the use of protocols supported by Class EA for 10G Base-T applications. They are characterised up to 500 MHz. 2. DESCRIPTION
1. Conductor: Bare solid copper, 23 AWG
2. Type of insulation: PE with low dielectric loss 3. Separator: Specially designed to optimise NEXT performance 4. Tape: Synthetic and water-repellent; ensures stability of the structure and performance after laying 5. Screen: Aluminium/polyester; ensures optimum ANEXT performance 6. Continuity: Tinned copper wire; for earthing on 9-pin connector 7. Type of sleeve: Low smoke zero halogen flame retardant material Note: The conductive part of the shielding is inside (wire side). Catalogue number: 327 78/328 78 Cat. 6A F/UTP cable for local area networks 4 pairs and 2 x 4 pairs 2/2 Technical data sheet: F00989EN/01 Updated on: 03/03/2011 Created on: 28/09/2009 7. ORDERING INFORMATION Catalogue number 327 78/328 78 Type F/UTP Colour Yellow RAL 1018 Pack (m) 500 Packaging Reel 8. ENVIRONMENTAL FEATURES Storage and transport temperature: 0 to + 50C Usage temperature: 20 to + 60C Fire resistance: IEC 60332-1, UL VW-1 9. STANDARDS AND APPROVALS Cat. 6A, 500 MHz EIA/TIA 568-C.2 EN 50173 EN 50288-2.1 IEC 11801 IEC 61156-5 5. TECHNICAL AND MECHANICAL FEATURES Catalogue Number 032778 032878 Type F/UTP F/UTP Type of sleeve LSOH LSOH Number of pairs 4 2 x 4 Assembly Pairs Pairs Diameter over insulation (mm) 1.16 0.05 1.16 0.05 Cable diameter (mm) 7.3 0.3 Weight of cable (kg/km) 51 57 Min. bending radius when laying (mm) 60 60 AWG gauge 23 23 6. ELECTRICAL FEATURES AT 20C Catalogue number 327 78 328 78 Type U / UTP F / UTP Maximum linear resistance of the cable (ohm/km) 95 * 95 * DC dielectric strength 1 kV/ 1 min * 1 kV/ 1 min * Minimum insulation resistance (Mohm.km) 5000 5000 Minimum propagation speed (marked on cable) > 66% > 66% Characteristic impedance from 1 to 100 MHz 100 15% 100 15% * According to standard IEC 61156-5 Cat. 6A F/UTP cable for local area networks 4 pairs and 2 x 4 pairs Catalogue number: 327 78/328 78