Powered by AI
The document discusses the general performance characteristics and rating conditions of different configurations of the LM6000 singular annular combustor (SAC) gas turbine.

The LM6000 comes in gas-fueled and liquid-fueled versions, and can be configured with different NOx suppression options like dry gas, gas with steam injection, gas with water injection, and liquid fuel with or without water injection.

The performance ratings provided in the tables are based on new and clean conditions and take into account inlet and exhaust losses, fuel type, use of water or steam for NOx suppression, and standard or cold day temperatures.

MID-IDM-6000-1

CHAPTER 3
Performance
3-1 General Performance and
Rating Conditions

The latest version of the steadystate performance program is a Microsoft Windows based
program which provides cycle analysis of all
versions of the LM6000.

This chapter provides general performance


characteristics of the various configurations of
the LM6000 singular annular combustor
(SAC) gas turbine. Due to the broad range of
application and configuration specific conditions, performance predictions should be modelled with the steadystate performance
computer program referenced in Appendix B,
paragraph B-2.

3-1.1

LM6000-PA Performance Rating

Table 3-1 summarizes basic rating information


for gas and liquid fueled versions of the original LM6000. These ratings are for the gas turbine in new and clean condition with the noted
inlet and exhaust losses.

Table 3-1 LM6000-PA Gas Turbine Ratings for Fuel - NOx Suppression Options
LM6000-PA Standard Day Ratings:
Gas-Dry

Gas-Steam

Gas-Water

Liquid-Dry

Liquid-Water

Power, HP (Average)

54,613

54,063

54,527

54,696

54,499

Heat Rate, Btu/lb (Avg)

6,347

6,157

6,560

6,395

6,724

NOx, ppm

N/A

25

42

N/A

42

Inlet/Exit Loss, in. H2O

4/4

4/10

4/4

4/4

4/4

59 (15)

59 (15)

59 (15)

59 (15)

59 (15)

Gas-Dry

Gas-Steam

Gas-Water

Liquid-Dry

Liquid-Water

Power, HP (Average)

58,216

58,387

58,546

58,303

58,626

Heat Rate, Btu/lb (Avg)

6,317

6,102

6,526

6,364

6,694

NOx, ppm

N/A

25

42

N/A

42

Inlet/Exit Loss, in. H2O

4/4

4/10

4/4

4/4

4/4

48 (8.9)

47 (8.3)

47 (8.3)

48 (8.9)

47 (8.3)

Inlet Temperature, F (C)


LM6000-PA Cold Day Power Ratings:

Inlet Temperature, F (C)

Note: Percent efficiency = Heat Rate (Btu/HP-hr)/14,275

Change 1

3-1

MID-IDM-6000-1

3-1.2

LM6000-PC Performance Rating

Table 3-2 summarizes basic rating information


for gas and liquid fueled versions of the
growth LM6000. These ratings are for the gas
turbine in new and clean condition with inlet
and exhaust losses as noted.
3-1.3

LM6000-PC SPRINT Rating

Performance rating information for the


LM6000-PC SPRINT system is included in
Table 3-3.

3-2 Rating Capability and


Characteristics
Figures 3-1 through 3-5 provide a definition of
the power envelope and continuous rating
characteristics of the various LM6000-PA and
-PC gas turbine models. Included are the
effects of gas or liquid fuel, with and without
water or steam (gas only) nitrogen oxide
(NOx) suppression. Also, the -PC model

3-2

Change 1

includes a version without variable inlet guide


vanes (VIGVs) for power generation. The
mechanical drive option requires use of
VIGVs. Figure 3-6 illustrates the unfired subidle gas turbine airflow.
SPRINT performance is shown for each
fuel/NOx combination using the no-VIGV
configuration only. The relative effect of
SPRINT is similar to that of the VIGVs but
is not illustrated.
Specific site application ratings, performance
guarantees, and performance at conditions
other than noted in the figures for all LM6000PA and -PC models must be determined using
the Average Engine Steady State Computer
Program as referenced in Appendix B, paragraph B-2. Computer program and calculated
performance output are proprietary to GE and
their authorized Original Equipment Manufacturers (OEMs).

MID-IDM-6000-1

Table 3-2 LM6000-PC Gas Turbine Ratings for Fuel - NOx Suppression Options
LM6000-PC Standard Day Ratings (with/without VIGVs):
Gas-Dry
Power (Average), SHP
Heat Rate (Avg), BTU/lb

Gas-Steam

Gas-Water

Liquid-Dry

Liquid-Water

57,859/58,152 57,526/57,912 57,923/58,292 55,980/56,509 58,035/58,411


6,057/6,047

5,885/5,873

6,343/6,331

6,134/6,119

6,418/6,407

NOx, ppm

N/A

25

42

N/A

42

Inlet/Exit Loss in. H2O

4/4

4/10

4/4

4/4

4/4

59 (15)

59 (15)

59 (15)

59 (15)

59 (15)

Gas-Water

Liquid-Dry

Liquid-Water

61,018/61,23

66,845/66,599

6,215/6,225

6,025/6,009

6,288/6,298

Inlet Temperature,
F (C)

LM6000-PC Cold Day Ratings (with/without VIGVs)


Gas-Dry
Power (Average), SHP
Heat Rate (Avg), BTU/lb

Gas-Steam

63,386/63,265 66,455/66,215 66,609/66,369


5,952/5,951

5,728/5,737

NOx, ppm

N/A

25

42

N/A

42

Inlet/Exit Loss, in. H2O

4/4

4/10

4/4

4/4

4/4

40 (4.4)

40 (4.4)

40 (4.4)

40 (4.4)

40 (4.4)

Inlet Temperature,
F (C)

Table 3-3 LM6000-PC SPRINTTM Gas Turbine Ratings for Fuel - NOx Suppression Options
LM6000-PC SPRINTTM Standard Day Ratings (without VIGVs):
Gas-Dry

Gas-Steam

Gas-Water

Liquid-Water

Liquid-Water

Power (Average), SHP

59,694

62,736

62,383

58,835

62,843

Heat Rate (Avg), BTU/lb

6,073

5,847

6,320

6,133

6,393

NOx, ppm

N/A

25

42

N/A

42

Inlet/Exit Loss, in. H2O

4/4

4/10

4/4

4/4

4/4

59 (15)

59 (15)

59 (15)

59 (15)

59 (15)

Inlet Temperature,
F (C)

LM6000-PC SPRINTTM Cold Day Ratings (without VIGVs):


Gas-Dry

Gas-Stream

Gas-Water

Liquid-Dry

Liquid-Water

Power (Average), SHP

64,395

68,183

68,098

62,897

68,580

Heat Rate (Avg), BTU/lb

5,963

5,746

6,237

6,024

6,311

NOx, ppm

N/A

25

42

N/A

42

Inlet/Exit Loss, in. H2O

4/4

4/10

4/4

4/4

4/4

40 (4.4)

40 (4.4)

40 (4.4)

40 (4.4)

40 (4.4)

Inlet Temperature,
F (C)

Change 1

3-3

MID-IDM-6000-1

Figure 3-1 LM6000 Gas Turbine Estimated Average Performance - PA/PC


Versions with Gas Fuel and No NOx Suppression

3-4

Change 1

MID-IDM-6000-1

Figure 3-2 LM6000 Gas Turbine Estimated Average Performance - PA/PC


Versions with Gas Fuel and Steam NOx Suppression

Change 1

3-5

MID-IDM-6000-1

Figure 3-3 LM6000 Gas Turbine Estimated Average Performance - PA/PC


Versions with Gas Fuel and Water NOx Suppression

3-6

Change 1

MID-IDM-6000-1

Figure 3-4 LM6000 Gas Turbine Estimated Average Performance - PA/PC


Versions with Distillate Fuel and No NOx Suppression

Change 1

3-7

MID-IDM-6000-1

Figure 3-5 LM6000 Gas Turbine Estimated Average Performance - PA/PC


Versions with Distillate Fuel and Water NOx Suppression

3-8

Change 1

MID-IDM-6000-1

Figure 3-6 Subidle Airflow - All Models

Change 1

3-9/(3-10 Blank)

MID-IDM-6000-1

You might also like