Pipeline Calculation PDF
Pipeline Calculation PDF
Background Information:
The Natural Gas Regulating Station can supply gas at a pressure of 40 psig to 100 psig, using a pressure control
valve, as per the seasonal consumer demand. During winter season the pressure may be increased to 100 psig
and during summer season the pressure may be reduced to 50 psig because gas consumption during winter
season is higher as compared to that in summer season, and only by increasing the gas pressure at the
downstream of the Natural Gas Regulating Station, the gas flow rate can be increased. The pressure at the
upstream of the Natural Gas Regulating Station is about 395 psig. However, it depends on pressure setting at
downstream of Natural Gas Regulating Station. Higher the downstream pressure, higher would be gas flow rate
and lower would be the upstream pressure.
Natural Gas Regulating Station
Inlet Pressure = 400 to 500 psig
6Offtake
20 meters
1
---- Muhammad Waqas Manzoor ---- Process Engineer ---- Engr.waqasmanzoor@gmail.com ----
S. No.
Pressure at U/S
of Regulating
Station (psig)
Pressure at D/S
of Regulating
Station (psig)
1.
397.0
50
2.08
2.
396.4
60
2.46
3.
395.2
80
3.23
4.
394.6
90
3.62
5.
394.0
100
4.01
It may also be noted that the actual absolute roughness would also be higher than 0.0457 millimeters depending
on the aging of pipeline and therefore, the actual maximum flow rate would be less than the values calculated
in this simulation. Therefore, the said line would be unable to cater the natural gas demand if it increases beyond
4 MMSCFD in 2015, as per the forecast.
The application of Dynamic Simulation in this particular case holds significance because Steady State Simulation
cannot simulate pressure balancing and therefore, can never imitate actual process in which flow rate depends
on pressure differential only. Even the pipe model in Steady State Simulation was unable to calculate natural
gas flow rate after the total pressure drop had been specified across the 6 dia. 12 km long pipeline.
2
---- Muhammad Waqas Manzoor ---- Process Engineer ---- Engr.waqasmanzoor@gmail.com ----
Gas Composition
The average gas composition for last month at the Regulating Station is used in the HYSYS Simulation.
3
---- Muhammad Waqas Manzoor ---- Process Engineer ---- Engr.waqasmanzoor@gmail.com ----
4
---- Muhammad Waqas Manzoor ---- Process Engineer ---- Engr.waqasmanzoor@gmail.com ----
5
---- Muhammad Waqas Manzoor ---- Process Engineer ---- Engr.waqasmanzoor@gmail.com ----
6
---- Muhammad Waqas Manzoor ---- Process Engineer ---- Engr.waqasmanzoor@gmail.com ----
7
---- Muhammad Waqas Manzoor ---- Process Engineer ---- Engr.waqasmanzoor@gmail.com ----