PMSB
PMSB
PMSB
ltl~jXIS
AUTOMATION TECHNOLOGY
1~. ltl~jXIS
AUTOMATION TECHNOLOGY
Features
System lay-out
1~.
ltl~AXIS
AUTOMATION TECHNOLOGY
The PMS Operator Panel is installed in the front door of the switch board at each generator section . The Operator Panel
provides an user-friendly interface for operation and monitoring of the generator set. The PMS Operator Panel is equipped with
built-in Control Processor function and executing power management functions . The PMS Operator Panel is delivered with a
graphic LCD display which provides the following information :
Generator power
Generator voltage
Busbar voltage
Frequency
Cos <p
Breaker status
System status
Alarm description
ln addition the PMS Operator Panel is equipped with the following operator push buttons with lamps:
Auto I manual
Start I stop
Run
Open I close
Increase I decrease
1st I 2nd standby
Menu
Alarm
The rear side of the PMS Operator Panel is equipped with terminal strips and connectors as follows :
Redundant Ethernet link for communication
to other PMS Operator Panels and (when installed)
to Mega-Guard Operator Workstations.
Power supply input 19-32VDC.
The PMS 110 Module is installed inside the main switchboard at each
generator section . 110 signals from generator, busbar, circuit breaker
and engine are directly connected to this 110 Module.
The PMS 110 Module is equipped with a controller which executes
generator control functions and the 110 Module communicates with
the PMS Operator Panel. The 110 Module can also be delivered as an
independent Check synchronizer.
The PMS 110 Module has the following inputs and outputs:
REQUEST I
ACCEPT I
CONSUMER BLOCK
REQUEST2
CONSUMER BLOCK
ACCEPT2
CONSUMER BLOCK
REQUEST 3
CONSUMER BLOCK
ACCEPT 3
SAFETY SYSTEM
SHUTOOWN
BUS TIE CLOSEO
(GX ANO GXI)
PREFERENTIAL
TRIP I
CBOPEN
All GENERATORS
PREFERENTIAL
TRIP2
CB
REV. POWER TRIP
CB
ABNORMAl TRIP
CB
CB
AUTO SYNC. FAIL
CB
STATUS
CB
CLOSE
ENGINE
CB
CURRENT Ll
GENERATOR
VOLTAGE
GENERATOR
L1--_.------._----------------------_.------._-------r-/"--~--------_.------._-------------- L1
L3
L2==++;~~===================+~~++======t;~~~=======th=~++============L2
L3
PMS
Operator
Panel
110 Cable
PMS
110 Module
PMS
110 Module
Circuit :
Breaker 3 :
Diesel
Engine