Adiabatic CSTR
Adiabatic CSTR
Adiabatic CSTR
Fogler
Problem description: Propylene oxide reacts with water to form propylene glycol. This is done in a
CSTR. Propylene oxide is dissolved in methanol (inert material). Water is supplied in excess, and
mixed just before entering the CSTR. The water has a bit of sulfuric acid (0.1 wt%) which is a catalyst.
However, the properties of the water can be used in the calculations directly, without accounting for
the presence of sulfuric acid. There is a small heat of mixing, but we can account for this and say that
the feed is effectively at a slightly higher temperature. The reaction is proposed to be conducted under
adiabatic conditions.
Q1. Given the feed data, enthalpy and Cp values, for a desired conversion (x = 0.85), find the volume
of the reactor needed. (Also find the operating temperature).
Q2. If the volume of the reactor is given, determine the conversion. (Also find the operating
temperature).
Q3. There is an issue with adiabatic operation. The operating temperature is too high. (e.g. the product
or reactant may evaporate, the tank may get corroded easily at higher temperature, other unwanted
reactions may occur to a significant extent, ). So, we are also given an upper limit for operating
temperature. The question then is to cool the reactor, perhaps with a cooling coil. In this case, we are
given U, A and Tc , i.e. overall heat transfer coefficient, cooling coil area and cooling fluid temperature.
We are also told that Tc does not vary much because the cooling fluid flow rate is very high and it has a
high specific heat capacity.
Q4. The cooling coil doesnt work for some reason. We want to know if we can adjust the flow rate of
propylene oxide (while keeping other flow rates the same) and maintain the temperature to be within
limits. So we want to calculate the temperature and conversion as a function of the FA-in.
The reaction is given by A + B C. A is propylene oxide, B is water and C is propylene glycol.
Methanol (M) is solvent for A.
Data: FA-in = 19.54 kmol/h, FB-in = 364.47 kmol/h, FM-in = 32.63 kmol/h, CpA = 146.4 J/mol/K, CpB =
75.3 J/mol/K, CpM = 81.6 J/mol/K, CpC = 192.4 J/mol/K, HRxn at 20 C = -84,591 J/mol of A reacted.
9084
Feed temperature = 24 C (after accounting for heat of mixing), k = 16.96 1012 e T h -1 where T is in
K.
The volumetric flow rates of methanol and propylene oxide were 1.365 kL/h each and that of water is
6.51 kL/h. Qin = 9.24 kL/h
Solution:
Q1.
For a CSTR, the design equation under steady state conditions is FAin + V rA out = FAout , and this can
be rewritten as follows.
Since FA = FAin (1 x A )
V
xA
=
FAin rA out
From the units of rate constant, we know that this is a first order reaction. So, this can be written as
V
x
=
. Note that we have dropped the subscript A of the conversion for the sake of simplicity.
Q k (1 x )
Also note that the value of k depends on the operating temperature and unless that is known, the above
equation can not be solved.
Heat balance:
Heat released during the reaction = heat needed to raise feed temperature to T which is the operating
temperature
To calculate the heat released during the reaction:
HRxn at temperature T = HRxn at 293K + (Cp-products Cp-reactants ) (T-293)
HRxn at temperature T = HRxn at 293K + Cp (T-293)
Q2. If the volume of the reactor is 1.25 m3, determine the conversion. Here, we know V, but we do
V
xMB
not know T or x. The basic equations remain the same. i.e. =
and
Q k (1 xMB )
FA-in xEB -HRxn at T = FA-in Cp-A (T-297) + FB-in Cp-B (T-297)+ FC-in Cp-C (T-297) = 32955 (T297)
The first equation can be written as
1.25
= = 0.135 h 1 =
9.241
xMB
12
16.96 10 e
12
xMB =
9084
T
(1 xMB )
9084
T
k
2.2896 10 e
=
9084
1 + k
1 + 2.2896 1012 e T
XMB
0.139
0.301
0.518
0.718
0.851
0.924
XEB
0.06
0.258
0.454
0.650
0.844
1.037
Note that for any positive order reaction, the mass balance equation ensures that the conversion is
within 0 to 1. The energy balance equation does not have such constraints, and one can get values
which are not physically meaningful. (e.g. if T = 295, XEB = -0.04).
Q3. We are informed that the temperature should not exceed 52 C because there will be a loss of the
product due to vaporization. The CSTR is 1.25 kL. It comes with a cooling system which has U = 2.
044 MJ m-2 h-1 K-1 and A = 3.716 m2. The cooling water can be maintained at 29.4 C (302.4 K).
Determine the operating temperature and conversion for this system.
The mass balance (design) equation remains the same, but the heat balance equation would change
now.
[1,652,902 + 572.5 (T-293)] xEB = U A (T-Tc) + 32966 (T-297).
i.e. heat generated = heat removed by the cooling system + heat needed to raise the feed to T
But, U A = 7,595.504 KJ/h/K, Tc= 302.4 K.
xEB =
Using this and the mass balance equation, we can find that T is between 310 and 315 K, and the value
is approximately 40 C. The corresponding conversion is about 0.36. Thus the temperature will be
below the limit.
Q4. It turns out that our cooling system is dysfunctional. So, instead of using cooling coils, can we
modify the flow rate of propylene oxide, and maintain a temperature of 52 C or less under adiabatic
operating conditions?
Assume that the flow rate of other streams and all other operating parameters are the same, and only
flow rate (molar as well as volumetric) of propylene oxide is changed. Note that the density of
propylene oxide is 0.83 g/ml and the molecular weight is 58 g/mol.
In the original problem, the volumetric flow rates of methanol and propylene oxide were 1.365 kL/h
each and that of water was 6.51 kL/h.
Let the new molar flow rate be FA-in-new kmol/h.
The new volumetric flow rate of propylene oxide = FA-in-new MWA / A.
= FA-in-new 58/0.83 = ( 69.87962 FA-in-new ) lit/h
Hence the total volumetric flow rate is (7,875 + 69.87962 FA-in-new) lit/h
The mass balance equation becomes
V
x
V
=
=
. i.e.
Q k (1 x )
( 7,875 + 69.87962 FA in new )
x
12
16.96 10 e
9084
T
(1 x )
The volume of the reactor is 1.25 m3. Therefore the equation becomes
1250
x
=
( 7,875 + 69.87962 FA in new ) 16.96 1012 e 9084
T
(1 x )
After re-arranging, this becomes
2.12 10 e
x
9084
T
9084
T
(1 x ) =
(1 x ) =
( 7,875 +
( 7,875 +
69.87962 FA in new )
69.87962 FA in new )
A in new
+
1
9084
16
2.12 10 e T
x=
Now, given a FA in new , we should be able to find the T and x, by simultaneously solving the mass and
energy balance equations. Now, we can plot the temperature (and conversion) as a function of FA in new .
The matlab code is given in the example. The optimization algorithm is not very robust, and at times
we get incorrect answers. For solving them simultaneously, we can use fmincon and a reasonable
temperature / conversion + random number as seed values.
Note that temperature and conversion increase rapidly near FA-in = 16 kmol/h. After that, the
temperature keeps increasing and conversion remains at 100%, as we increase FA-in. This is contrary to
what one would expect under isothermal conditions.
Q5: If we conduct the reaction in a PFR, what will be the volume required for 85% conversion?
Data: FA-in = 19.54 kmol/h, FB-in = 364.47 kmol/h, FM-in = 32.63 kmol/h, CpA = 146.4 J/mol/K, CpB =
75.3 J/mol/K, CpM = 81.6 J/mol/K, CpC = 192.4 J/mol/K, HRxn at 20 C = -84,591 J/mol of A reacted.
12
9084
T
V =Q
dx
k (1 x )
0
FAin x H T =
(F
i in
Tin
C p i dT )
We can create a table and then use calculator-based integration or do the integration by numerical
methods implemented in software such as Matlab.
x
0
0.2
0.4
0.6
0.8
0.85
T
297
307
317
327
338
340
k
0.8834
2.41
6.21
15.17
35.33
43.3
K(1-x)
0.8834
1.928
3.73
6.07
7.07
6.5
Q/(k(1-x))
10.4596
4.792
2.48
1.522
1.30
1.4212
A very rough integration gives that the PFR volume needed to get a conversion of 80% (not 85%) itself
is 2.4 m3. In comparison, a CSTR of 1.25 m3 was needed to get 85% conversion.