Description
Overload protection trip class 10
Phase loss sensitivity
Temperature compensation from -25 +60 C
Adjustable current setting for overload protection
Automatic or manual reset selectable
Suitable for three- and single-phase application
Trip-free mechanism
Status indication
STOP and TEST function
Direct mounting onto block contactors
Sealable operating elements
Approvals
Marks
CE
1SBC101247F0010
Order data
TF42 screw terminal
For AF contactors
Setting range
Type
Order code
Packing Weight
unit
per PCE
PCE
kg
TF42-0.13
1SAZ721201R1005
0.130
A
0.10 ... 0.13
0.13 ... 0.17
TF42-0.17
1SAZ721201R1008
0.130
TF42-0.23
1SAZ721201R1009
0.130
TF42-0.31
1SAZ721201R1013
0.130
TF42-0.41
1SAZ721201R1014
0.130
TF42-0.55
1SAZ721201R1017
0.130
TF42-0.74
1SAZ721201R1021
0.130
TF42-1.0
1SAZ721201R1023
0.130
TF42-1.3
1SAZ721201R1025
0.130
TF42-1.7
1SAZ721201R1028
0.130
TF42-2.3
1SAZ721201R1031
0.130
cULus UL 508
TF42-3.1
1SAZ721201R1033
0.130
CB scheme
TF42-4.2
1SAZ721201R1035
0.130
TF42-5.7
1SAZ721201R1038
0.130
CCC
TF42-7.6
1SAZ721201R1040
0.130
GOST-R
ABS
RINA
DNV
Lloyds Register
TF42-10
1SAZ721201R1043
0.130
TF42-13
1SAZ721201R1045
0.130
TF42-16
1SAZ721201R1047
0.130
TF42-20
1SAZ721201R1049
0.145
TF42-24
1SAZ721201R1051
0.145
TF42-29
1SAZ721201R1052
0.145
TF42-35
1SAZ721201R1053
0.145
1SAZ721201R1055
0.145
Functional description
1
1SBC101247F0010
4 Status indication
4
5
5 RESET button
7
6 Signaling contacts 97-98
8
2CDC232001F0010
1~
Contact 95-96
Contact 97-98
Trip state
open
closed
RESET state
closed
open
open
closed
open
closed
open
closed
open
open
95
97
96
98
TEST
2T1
4T2
6T3
2 - 2CDC106023D0201
STOP
2CDC232001F0009
A
M
Comment
ON
Wiring diagram
RESET
Status indication
Resistance and power loss per pole and short-circuit protection device
Type
Setting range
lower value
A
Resistance per
pole
upper value
A
Power loss
Short-circuit
protection device
at lower value
W
at upper value
W
coordination
type 2
TF42-0.13
0.10
0.13
106508.88
1.1
2.0
0.5 A, Type T
TF42-0.17
0.13
0.17
62283.74
1.1
2.0
1.0 A, Type T
TF42-0.23
0.17
0.23
37429.00
1.1
2.0
1.0 A, Type T
TF42-0.31
0.23
0.31
20603.43
1.1
2.0
1.0 A, Type T
TF42-0.41
0.31
0.41
11421.77
1.1
2.0
2.0 A, Type gG
TF42-0.55
0.41
0.55
6347.11
1.1
2.0
2.0 A, Type gG
TF42-0.74
0.55
0.74
3615.62
1.1
2.0
4.0 A, Type gG
TF42-1.0
0.74
1.00
1920.00
1.1
2.0
6.0 A, Type gG
TF42-1.3
1.00
1.30
1065.09
1.1
2.0
6.0 A, Type gG
TF42-1.7
1.30
1.70
622.84
1.1
2.0
10.0 A, Type gG
TF42-2.3
1.70
2.30
340.26
1.1
2.0
10.0 A, Type gG
TF42-3.1
2.30
3.10
187.30
1.1
2.0
10.0 A, Type gG
TF42-4.2
3.10
4.20
102.04
1.1
2.0
20.0 A, Type gG
TF42-5.7
4.20
5.70
59.10
1.1
2.0
20.0 A, Type gG
TF42-7.6
5.70
7.60
31.16
1.1
2.0
35.0 A, Type gG
TF42-10
7.60
10.00
19.30
1.1
2.0
35.0 A, Type gG
TF42-13
10.00
13.00
13.07
1.3
2.2
40.0 A, Type gG
TF42-16
13.00
16.00
7.79
1.3
2.2
40.0 A, Type gG
TF42-20
16.00
20.00
6.25
1.8
2.6
63.0 A, Type gG
TF42-24
20.00
24.00
4.51
1.8
2.6
63.0 A, Type gG
TF42-29
24.00
29.00
3.09
1.8
2.6
63.0 A, Type gG
TF42-35
29.00
35.00
2.25
2.1
2.8
80.0 A, Type gG
TF42-38
35.00
40.00
1.72
2.1
2.8
80.0 A, Type gG
Technical diagrams
Intermittent periodic duty
(s)
40
(Op/h)
140
20
11
100
ta =
ta = 5
20
40
60
ABB827833
20
0
1.5
s
3s
ta =
80 100 (%)
duty ratio
4
3
2
7 8
7.4
ABB836246
tripping time
ta =
40
60
10
6
0.5
80
ta
switching frequency
120
Dimensions
in mm and inches
16.2
11.7
0.64"
0.46"
50.25
0.09"
2.7
1.98"
0.11"
9.1
12.35
0.36"
8.1 0.32"
14.4
45
1.77"
0.57"
0.49"
52.6
2.07"
66.4
70.5
2.61"
2.78"
2CDC232005F0009
88.3
3.48"
2.3
2CDC106023D0201 - 3
- V d.c.
Setting range - thermal overload protection
Trip class
10
Rated frequency
50/60 Hz
Number of poles
Isolation data
2T1-4T2-6T3
6 kV
690 V
Pollution degree
Electrical connection
Connecting capacity
solid
TF42 20 A
TF42 > 20 A
stranded
Stripping length
12 mm
Tightening torque
1.5 2.5 Nm
Connection screw
M4 (Pozidrive 2)
4 - 2CDC106023D0201
2.5 2.7 Nm
Auxiliary circuit
95-96, 97-98
600 V
NC, 95-96
6A
NO, 97-98
4A
Rated frequency
d.c., 50/60 Hz
Number of poles
1NC + 1NO
NC, 95-96
3.00 A
NO, 97-98
0.75 A
at AC15 at 220-230-240 V
NC, 95-96
3.00 A
NO, 97-98
0.75 A
at AC15 at 440 V
NC, 95-96
0.75 A
NO, 97-98
0.75 A
NC, 95-96
0.75 A
at AC15 at 480-500 V
NO, 97-98
0.75 A
at DC13 at 24 V
NC, 95-96
1.25 A
NO, 97-98
1.25 A
at DC13 at 110-120-125 V
NC, 95-96
0.55 A
NO, 97-98
0.55 A
at DC13 at 250 V
NC, 95-96
0.27 A
NO, 97-98
0.27 A
NC, 95-96
0.15 A
NO, 97-98
0.15 A
NC, 95-96
6 A, Type gG
NO, 97-98
4 A, Type gG
at DC13 at 500 V
Minimum switching capacity
Short-circuit protection device
17 V / 3 mA
Isolation data
95-96, 97-98
6 kV
690 V
Pollution degree
Electrical connection
Connecting capacity
95-96, 97-98
solid
stranded
Stripping length
9 mm
Tightening torque
1 ... 1.5 Nm
Connection screw
M3 (Pozidrive 2)
2CDC106023D0201 - 5
General data
Duty time
100%
Dimensions (W x H x D)
Weight
Mounting
Mounting position
Minimum distance to other units same type
position 1-5
horizontal
none
vertical
not applicable
horizontal
none
vertical
on request
Degree of protection
IP20
Altitude
up to 2000 m
Electromagnetic compatibility
Electromagnetic compatibility
not applicable
Environmental data
Ambient air temperature
Operation
open - compensated without derating -25 ... +60 C (> 38 A: -25 ... +50 C)
open
Storage
Temperature compensation
continuous
5g / 3 ... 150 Hz
25g / 11 ms
Standards / directives
Product standard
IEC/EN 6094741
IEC/EN 60497-5-1
IEC/EN 60947-1
UL 508, CSA22.2 No. 14
2006/95/EC
EMC Directive
2004/108/EC
RoHS Directive
2002/95/EC
6 - 2CDC106023D0201
SCCR
Fuse type
SCCR
Fuse type
TF42-0.13
0.13 A
18 kA
1 A, K5
100 kA
30 A, Class J
TF42-0.17
0.17 A
18 kA
1 A, K5
100 kA
30 A, Class J
TF42-0.23
0.23 A
18 kA
1 A, K5
100 kA
30 A, Class J
TF42-0.31
0.31 A
18 kA
3 A, K5
100 kA
30 A, Class J
TF42-0.41
0.41 A
18 kA
3 A, K5
100 kA
30 A, Class J
TF42-0.55
0.55 A
18 kA
3 A, K5
100 kA
30 A, Class J
TF42-0.74
0.74 A
18 kA
3 A, K5
100 kA
30 A, Class J
TF42-1.0
1.00 A
18 kA
6 A, K5
100 kA
30 A, Class J
TF42-1.3
1.30 A
18 kA
6 A, K5
100 kA
30 A, Class J
TF42-1.7
1.70 A
18 kA
6 A, K5
100 kA
30 A, Class J
TF42-2.3
2.30 A
18 kA
10 A, K5
100 kA
30 A, Class J
TF42-3.1
3.10 A
18 kA
10 A, K5
100 kA
30 A, Class J
TF42-4.2
4.20 A
18 kA
15 A, K5
100 kA
30 A, Class J
TF42-5.7
5.70 A
18 kA
20 A, K5
100 kA
30 A, Class J
TF42-7.6
7.60 A
18 kA
25 A, K5
100 kA
30 A, Class J
TF42-10
10.0 A
18 kA
35 A, K5
100 kA
45 A, Class J
TF42-13
13.0 A
18 kA
40 A, K5
100 kA
45 A, Class J
TF42-16
16.0 A
18 kA
60 A, K5
100 kA
45 A, Class J
TF42-20
20.0 A
18 kA
80 A, K5
100 kA
60 A, Class J
TF42-24
24.0 A
18 kA
80 A, K5
100 kA
60 A, Class J
TF42-29
29.0 A
18 kA
100 A, K5
100 kA
100 A, Class J
TF42-35
35.0 A
18 kA
150 A, K5
100 kA
175 A, Class J
TF42-38
38.0 A
18 kA
150 A, K5
100 kA
175 A, Class J
Main circuit
Maximum operational voltage
600 V a.c.
Trip rating
125 % of FLA
Electrical connection
Connecting capacity
TF42 20 A
TF42 > 20 A
stranded
Stripping length
12 mm
Tightening torque
13 ... 22 Ib-in
22 Ib-in
Auxiliary circuit
Conventional thermal current
NC, 95-96
5A
NO, 97-98
2.5 A
NC, 95-96
B600, Q300
NO, 97-98
D300, Q300
stranded
Electrical connection
Connecting capacity
Stripping length
9 mm
Tightening torque
9 ... 13 Ib-in
2CDC106023D0201 - 7
Note:
We reserve the right to make technical changes
or modify the contents of this document without
prior notice. With regard to purchase orders, the
agreed particulars shall prevail. ABB AG does
not accept any responsibility whatsoever for
potential errors or possible lack of information in
this document.
We reserve all rights in this document and in
the subject matter and illustrations contained
therein. Any reproduction, disclosure to third
parties or utilization of its contents in whole
or in parts is forbidden without prior written
consent of ABB AG.
Copyright 2011 ABB
All rights reserved
Contact us