Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Abb Wiring Diagrams

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Wiring diagrams

Content
Information for reading and graphic symbols . ................................................................... 5/2
Wiring diagrams of the circuit-breakers............................................................................... 5/3
Electrical accessories........................................................................................................... 5/4

5/1
1SDC210032D0202

Information for reading and graphic symbols

State of operation represented


The diagram is shown under the following conditions:
- circuit-breaker open;
- circuits without voltage;
- trip units not tripped.
Incompatibility
A1 A2
Accessory circuits cannot be supplied with single-pole circuit-breakers.
The applications indicated in figures 1-2-6, which are supplied as an alternative, can be supplied with two-pole circuit-breakers.
All the applications indicated in the figures can be supplied with three-pole and four-pole
circuit-breakers. Figures 1-2-3-4 are provided as an alternative. Figures 5-6 are provided as
an alternative.
A3
The circuits indicated in the following figures cannot be supplied at the same time on the
same circuit-breaker:
1-2-3-4
5-6

Graphic Symbols (IEC 60617 and CEI 3-143-26 Standards)

Thermal effect

Terminal

Change-over break before


make contact

Electromagnetic effect

Plug and socket


(male and female)

Circuit-breaker with
automatic release

Mechanical connection (link)

Resistor (general symbol)

Operating device
(general symbol)

Operated by pushing

Current transformer

Instantaneous overcurrent
or rate-of-rise relay

Operated by turning

Make contact

Overcurrent relay with inverse


long time-lag characteristic

Connection of conductors

Break contact

5/2
1SDC210032D0202

Wiring diagrams of the circuit-breakers

Operating status A1 A2

Single-pole circuit-breaker with


thermomagnetic trip unit

Two-pole circuit-breaker with


thermomagnetic trip unit

Three-pole circuit-breaker with


thermomagnetic trip unit

Four-pole circuit-breaker with


thermomagnetic trip unit

Operating status A3

Three-pole/four-pole circuit-breaker with thermomagnetic trip unit

Three-pole/four-pole circuit-breaker with electronic trip unit

Caption
Q
=
K51
=


TI/L1
=
TI/L2
=
TI/L3
=
TI/N
=
X0
=
YO1
=

Main circuit-breaker
Electronic trip unit ELT LI, with the following protection functions:
L overload protection with inverse long time-delay trip
I short-circuit protection with instantaneous time-delay trip
Current transformer placed on phase L1
Current transformer placed on phase L2
Current transformer placed on phase L3
Current transformer placed on the neutral
Connector for the YO1 trip coil
Trip coil of the electronic trip unit

5/3
1SDC210032D0202

Electrical accessories

Shunt opening and undervoltage releases A1 A2

Figure:
1)
2)
3)
4)

Shunt opening release (SOR-C o YO)


Undervoltage release (UVR-C o YU)
Instantaneous undervoltage release with an early contact in series (AUE-C+UVR-C)
Instantaneous undervoltage release with two early contacts in series (AUE-C+UVR-C)

Notes
B) The undervoltage release is supplied for power supply branched on the supply side of the circuit-breaker
or from an independent source: circuit-breaker closing is only allowed with the release energised (the
lock on closing is made mechanically).
C) The S4/1 and S4/2 contacts shown in figures 3-4 open the circuit with circuit-breaker open and
close it when a manual closing command is given by means of the rotary handle in accordance with
the Standards regarding machine tools (closing does not take place in any case if the undervoltage
release is not supplied).
F) Additional external undervoltage resistor supplied at 250V DC or 380/440V AC.

Caption
Q/0
=
R
=
S4/1-2
=
SO
=
V1
=
V4
=

XV
=
YO
=
YU
=

5/4
1SDC210032D0202

Circuit-breaker auxiliary contacts


Resistor (see note F)
Early auxiliary contacts activated by the rotary handle of the circuit-breaker (see note C)
Pushbutton or contact for opening the circuit-breaker
Circuit-breaker applications
Indicative apparatus and connections for control and signalling, outside
the circuit-breaker
Terminal boards of the applications
Shunt opening release (SOR-C)
Undervoltage release (UVR-C) (see notes B and C)

Shunt opening and undervoltage releases A3

Figure:
1)
2)
3)
4)

Shunt opening release (SOR-C o YO)


Undervoltage release (UVR-C o YU)
Instantaneous undervoltage release with an early contact in series (AUE-C+UVR-C)
Instantaneous undervoltage release with two early contacts in series (AUE-C+UVR-C)

Notes
B) The undervoltage release is supplied for power supply branched on the supply side of the circuit-breaker
or from an independent source: circuit-breaker closing is only allowed with the release energised (the
lock on closing is made mechanically).
C) The S4/1 and S4/2 contacts shown in figures 3-4 open the circuit with circuit-breaker open and
close it when a manual closing command is given by means of the rotary handle in accordance with
the Standards regarding machine tools (closing does not take place in any case if the undervoltage
release is not supplied).
F) Additional external undervoltage resistor supplied at 250V DC or 380/440V AC.

Caption
Q/0
=
R
=
S4/1-2
=
SO
=
V1
=
V4
=

XV
=
YO
=
YU
=
X1, X8
=

Circuit-breaker auxiliary contacts


Resistor (see note F)
Early auxiliary contacts activated by the rotary handle of the circuit-breaker (see note C)
Pushbutton or contact for opening the circuit-breaker
Circuit-breaker applications
Indicative apparatus and connections for control and signalling, outside
the circuit-breaker
Terminal boards of the applications
Shunt opening release (SOR-C)
Undervoltage release (UVR-C) (see notes B and C)
Connectors for the circuit-breaker auxiliary circuits
5/5
1SDC210032D0202

Electrical accessories

Auxiliary contacts A1 A2

Figure:
5) Two changeover contacts for electrical signalling of circuit-breaker open/closed and one changeover
contact for signalling circuit-breaker in tripped position due to thermomagnetic trip unit or SOR-C or
UVR-C intervention (2Q+1SY)
6) One changeover contact for electrical signalling of circuit-breaker open/closed and one changeover
contact for signalling circuit-breaker in tripped position due to thermomagnetic trip unit or SOR-C or
UVR-C intervention (1Q+1SY)

Caption
Q/1, 2
SY
V1
V4
XV

5/6
1SDC210032D0202

= Circuit-breaker auxiliary contacts


= Contact for electrical signalling circuit-breaker open due to trip of the thermomagnetic trip
unit YO (SOR-C), YU (UVR-C) (tripped position)
= Circuit-breaker applications
= Indicative apparatus and connections for control and signalling, outside the circuit-breaker
= Terminal boards of the applications

Auxiliary contacts A3

Figure:
5) Three changeover contacts for electrical signalling of circuit-breaker open/closed and one changeover contact for signalling circuit-breaker in tripped position due to thermomagnetic trip unit or SORC or UVR-C intervention (3Q+1SY)
6) One changeover contact for electrical signalling of circuit-breaker open/closed and one changeover
contact for signalling circuit-breaker in tripped position due to thermomagnetic trip unit or SOR-C or
UVR-C intervention (1Q+1SY)

Caption
Q/1, 2, 3 = Circuit-breaker auxiliary contacts
SY
= Contact for electrical signalling circuit-breaker open due to trip of the thermomagnetic trip
unit YO (SOR-C), YU (UVR-C) (tripped position)
V1
= Circuit-breaker applications
V4
= Indicative apparatus and connections for control and signalling, outside the circuit-breaker
XV
= Terminal boards of the applications
X2, X7
= Connectors for the circuit-breaker auxiliary circuits

5/7
1SDC210032D0202

You might also like