Pandaros
Pandaros
Pandaros
1502-0065
1. Function:___________________________________________________________1
1.1
1.2
1
1
2. Assembly:__________________________________________________________2
2.1
2.2
Wiring:
Terminal strip allocation:
2
3
3. Settings: ___________________________________________________________4
3.1
3.2
Current range:
Position settings auto adjust:
5
5
General:
Controller warnings / self-resetting:
Controller emergency shutdowns:
7
7
7
5. Troubleshooting: ____________________________________________________8
5.1
1. Function:
1.1
1.2
Protection functions:
The servo amplifier is equipped with protection functions both for the actuator (current limiter) and the
auto-protection functions (short-circuit protection, etc.).
Short-circuit protection:
If a short circuit occurs in the power output side of the actuator circuit, the amplifiers output transformer is
switched off automatically.
The controller is pole-error protected and short-circuit protected at all the digital and analogue inputs and
outputs of the control electronics against the positive and negative of the power supply.
Overvoltage / undervoltage protection:
If the supply voltage exceeds 32 V or falls below 9 V, the amplifier is switched off and the failure
transmitting output is activated.
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 1 / 9
1502-0065
Current limiter:
A peak current of 6.4 A (max. 20 sec.) and a constant current of 3.2 A are permitted in order to protect the
actuator from thermal overload. The controller guarantees these limiting conditions by reducing the
current to the constant current approx. 5 seconds after the permissible constant current is exceeded. The
power consumption of the actuator can be checked by measuring the current at the output side of the
actuator circuit.
The current limiter is only activated if the actuator is obstructed or overloaded. This is an
indication of the incorrect setting of a mechanical component (control rod assembly, throttle
valve) or a malfunction!
2. Assembly:
The controllers control electronics are contained in a metal housing (B x H x D = 165 x 105 x 65mm),
which is suitable for top-hat rail mounting. The connection is established via the terminal strip on the
circuit board.
2.1
Wiring:
Cable sets with prepared connectors (for actuators) are used to make the electrical connection with the
actuators.
TL 234658
StG 10
Type 2 and 3 engines
TL 234666
StG 30
Type 6 engines
The connection with the actuators is established by means of two cables.
L1: approx. 9 m 2-pole, 1.5 mm, shielded plastic-sheathed cable (engine connection)
L2: approx. 9 m 3-pole, 0.75 mm, shielded plastic-sheathed cable (signal connection)
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 2 / 9
1502-0065
Both cables are led to the connection on the actuator in a common connector (MIL). The cable shields
must be led to the terminal strip on the controllers circuit board. The shield for the signal cable L2 must
be connected to the corresponding terminal strip (14 | Shld). The shields for L1 and L2 must be earthed at
the entry to the module interface box.
2.2
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Function
Not in use!
Not in use!
Not in use!
Not in use!
Shield for mA signal
Not in use!
mA signal setpoint (+)
mA signal setpoint (-)
Dig. input for auto adjust
(bridge to Terminal No. 11)
Failure transmitting output
Dig. input for servomotor stop
(bridge to Terminal No. 9 for
actuator - auto adjust)
Not in use!
Not in use!
Shield for position signal
GND for StG position sensor
StG position signal
Power supply for StG position
sensor
Bridge to Terminal No. 22
Bridge to Terminal No. 23
0 V supply
+24 V supply
Bridge to Terminal No. 18
Bridge to Terminal No. 19
Engine 1
Engine 2
Description on
cover
Pin No. of
actuator
Cable conductors
for L1 and L2
SHIELD
FB-COM
FB-MEA
FB-REF
Connector housing
E
A
D
Shield for L2
3 L2
2 L2
1 L2
DRIVEDRIVE+
+
DRIVEDRIVE+
DRIVE- to Actuator
DRIVE+ to Actuator
B
C
1 L1
2 L1
SHIELD
AC symbol
GND
Closing contact
symbol (SpD)
Lamp symbol
STOP / DI (Stp)
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 3 / 9
1502-0065
Function
Shield for position signal
X9: 2
+12 V
X9: 3
X9: 4
X9: 5
X9: 6
X9: 7
X9: 8
X9: 9
X9: 10
/
/
/
/
/
/
/
/
Pos.
GND
+mA
+mA
Earth symbol
Opening contact
Base
Closing contact
Function
+24 V supply
0 V supply
Shield for engine
Engine 1
Engine 2
Shield
X10: 4
X10: 5
X10: 6
/
/
/
M1
M2
Earth symbol
Cable L2
(3 x 0.75)
Shield
16
15
7
8
5
2
3
A
E
Cable L1
(2 x 1.75)
Shield
1
2
3. Settings:
As supplied, the preset 0% and 100% position of the controller is only approximate. All other settings,
such as control circuit amplification, have already been adjusted to the optimum value for operating with
the StG 10 and StG 30. It is essential that the 0% and 100% position is set accurately before the engine
is operated for the first time. The setting is made by means of an auto adjust function, i.e. when a wire
jumper is connected to the Pandaros controller the actuator is adjusted automatically for the 0% and
100% position.
The auto adjust function must be carried out each time the controller or the actuator is replaced. An auto
adjust is also required when the Pandaros is retrofitted to a field system and mechanical changes are
made, e.g. adjustments to the control rod assembly!
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 4 / 9
1502-0065
3.1
Current range:
The Pandaros must be selected for the analogue position setpoint with a current signal in the range of 0
20 mA. The setpoint cannot be switched from 0 20 mA to 0 200 mA, as is the case with the Alge
servo amplifier (TL No. 319169).
When the Pandaros is retrofitted to EMS 2000 systems the 0 200 mA setpoint signal must be
adjusted to a 0 20 mA setpoint signal by means of an active measuring transducer with 3-way
galvanic separation (input / output / supply).
The measuring transducer is part number 399003.
3.2
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 5 / 9
1502-0065
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 6 / 9
1502-0065
General:
The controller has a cumulative failure transmitting outlet (warning and emergency shutdown), in the form
of a group alarm via a switching transistor output. When an internally monitored failure occurs, the
transistor switches over and internally connects the failure transmitting output (terminal 10) to the earth
for the power supply (0V | terminal 20). Pandaross internal diagnosis system can distinguish between
self-resetting error warnings and errors which will result in emergency shutdown of the servomotor.
This cumulative failure transmitting output (warning and emergency shutdown) is integrated by means of
a pull-up resistor directly into the dia.ne AMM as warning number 1192 with the text Actuator/Controller
Failure (closed-circuit principle). In general, controllers in new installations have been switched off during
engine standstill since the year 2000. This extends the service life of the device. As the controller is not
activated during engine standstill, the controllers cumulative failure transmitting output is only monitored
by the dia.ne AMM when the engine is running.
4.2
4.3
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 7 / 9
1502-0065
5. Troubleshooting:
5.1
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 8 / 9
1502-0065
Issued:
Greuter/Elektronik
Checked:
Elektronik
EN
1502-0065_EN.doc
Index:
Date: 2003-12
Page - No.: 9 / 9