Brochure - GreenMAX
Brochure - GreenMAX
Brochure - GreenMAX
GreenMAX
Benefits of GreenMAX
Exclusively From GreenMAX
Dimming and Switching in the Same Cabinet
GreenMAX allows you to set advanced control schemes from a single cabinet
Easy to Install
GreenMAX cabinets are shipped empty to increase ease of installation and components can be shipped
separately to meet your lighting demands, schedule and help manage cash flow
Easy to Design
Unlimited and flexible lighting configurations allow you to program based on behavioral relationship
commands
Configure your lighting system in the space with a portable Handheld Display Unit (HDU) or from a
remote location
Leviton GreenMAX
What is GreenMAX?
GreenMAX is a completely modular design offering a wide variety of relay options. GreenMAX includes
integrated dimming, a 25,000A Short Circuit Current Rating (SCCR) and daylight harvesting. Programming
and monitoring GreenMAX is quick and simple with a portable Handheld Display Unit (HDU) that allows
for onsite or remote access. The modular design allows total installation flexibility and labor savings.
Designed for the contractor, specifier and end user, GreenMAX offers the best performance, reliability,
flexibility and energy savings of any relay control available.
Photocell
Occupancy
Sensor
0-10V BALLAST
Loads
LumaCan
GreenMAX 16 - Relay Cabinet
Photocell
Occupancy
Sensor
0-10V BALLAST
Loads
Keyswitch
www.leviton.com/greenmax
GreenMAX
BEHAVIORS
Number
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
Description
Lights turned ON with the switch.
Can be turned OFF with switch.
Occupancy Sensor will turn OFF upon vacancy.
Lights turned ON with the Occupancy Sensor.
Can be turned ON/OFF with switch.
Occupancy Sensor will turn OFF upon vacancy.
Occupancy Sensor turns lights ON/OFF.
Switch ON/OFF.
Time triggers a Blink Warn sequence, an OFF blink followed by a variable ON delay.
Switch interrupts sequence and starts override timer.
Will automatically turn OFF relay if override timer reaches zero.
Turn ON at specific time.
Turn OFF at specific time.
Occupancy Sensor turns ON lights with occupancy.
Measured light levels above Photocell trigger point turns OFF or keeps lights OFF,
below set-point allows control by Occupancy Sensor.
Occupancy Sensor turns OFF lights with vacancy.
Switch turns ON/OFF lights.
Measured light levels above Photocell trigger point turns OFF or keep lights OFF,
below set-point allows control by Occupancy Sensor.
Occupancy Sensor turns OFF lights with vacancy.
Occupancy Sensor turns ON lights with occupancy.
Measured light levels above Photocell trigger point turns OFF or keep lights OFF,
below set-point allows Occupancy Sensor control.
Switch can turn ON/OFF lights by overriding Occupancy Sensor control.
Occupancy Sensor will turn OFF lights upon vacancy.
Switch ON/OFF.
Measured light levels above Photocell trigger point turns OFF or keep lights OFF,
below set-point allows Switch control.
Turn ON at specific time (Used for Exterior Lighting).
Measured light levels above Photocell trigger point turns OFF or keep lights OFF,
below set-point relinquishes control to the constant ON state.
www.leviton.com/greenmax
GreenMAX
To other
classrooms
GreenMAX Applications
Lumacan
Photocell
Occupancy
Sensor
4-Button
Switch
Handheld
Display
Unit (HDU)
Proven interoperability and seamless integration with building management systems allows GreenMAX
Relay Control Panels to follow set Behaviors based on time, day and the relationship between the switches,
occupancy sensors and photocells in a given area.
Schools
Offices
Retail Stores
Convention Centers
Airports
Restaurants
Government Facilities
Hospitals/Medical Offices
OFFICE EXAMPLE
Relay 1
Relay 2
Relay 3 Relay 4
To
Lights
LumaCan
GreenMAX
Low Voltage
Zone 2
Relay 5
Zone 2
Zone 1
Relay 9
Zone 2
Relay 10
Relay 8
Relay 6
Zone 1
Relay 7
Zone 1
Window
GreenMAX Cabinet
Lights
Wall
Window
Area/Zone Separator
Line/Load
Digital Switch
Remote Low Voltage
LumaCan
Low Voltage Wiring
Photocell
Occupancy Sensor
www.leviton.com/greenmax
GreenMAX
Classroom example
Window
Zone 1
Relay 1
Zone 2
Relay 2
Zone 3
LumaCan
Relay 3
GreenMAX
Classroom 3 Zones:
This typical classroom configuration achieves daylight harvesting
with a photocell and occupancy sensor that turns off the light
when the room is vacant
GreenMAX Cabinet
GreenMAX relays can dim all the lighting within the zone to the
same lighting percentage
Wall
Light
Window
Area/Zone Separator
Line/Load
Digital Switch
Remote Low Voltage
LumaCan
Low Voltage Wiring
Photocell
Occupancy Sensor
Command Module
USB Port
LumaCAN
Port
Ethernet
Port
Power
Supply
Main
Processor
Low Voltage
16-Input Card
Communication Link
(Between Command
Module and Relay
Insert Panel)
Wiring
Diagram
Relay
Insert
Panel
Lock
Right
Panel
Cover
Door
with
Split
Hinges
Left Panel
Cover
2-Pole
Relay
Grounding
Points
Lower Ventilation
Cover
Power and
Lighting
Wire Way
Manual
Actuator
GreenMAX Innovation
www.leviton.com/greenmax
GreenMAX
GreenMAX Switches
10
www.leviton.com/greenmax
11
ORDERING INFORMATION
CAT. NO.
DESCRIPTION
Tubs and Covers (all cabinets are surface mount with a locking door)
R08TC-100
R16TC-100
R32TC-100
R48TC-100
RPM08-108
Main Command Module with 8-Port Low Voltage Input Card, 100-277VAC, 50/60Hz
RPM16-116
Main Command Module with 16-Port Low Voltage Input Card, 100-277VAC, 50/60Hz
Panel Interiors
R0800-000
R1600-000
R1616-1CB
R1616-1TB
R1616-2CB
R1616-2TB
RHDU1-BKT
Remote Inputs with Power Supply (all remote inputs are rated 100-277VAC)
RLV08-110
RLV16-110
RELAY-1DS
RELAY-1TB
RELAY-2CB
RELAY-2TB
RELAY-BFM
RGBAR-008
RGBAR-016
165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 Telephone: 1-800-469-7890 FAX: 1-800-563-1853
Lago Tana 43, Mexico DF, Mexico CP 11290 Tel. (+52) 55-5082-1040 www.leviton.com.mx
12
G-8323A/K11-ak
Rev Nov 2011