Chloride 80-NET: Secure Power For Mission Critical Applications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Chloride 80-NET from 60 to 500 kW

Secure Power for Mission Critical Applications

Emerson Network Power, a division of Emerson, is a global company that combines technology
with design to supply innovative solutions for the benefit of its customers.
Emerson Network Power protects and optimizes critical infrastructure for data centers,
communications networks, healthcare and industrial facilities.
Emerson Network Powers broad technology base and global expertise support a full spectrum of
enterprise-wide solutions for todays vital business needs.

Regardless of your size,


you cant afford for your
critical business systems
to go down and you cant
waste time recovering your
IT infrastructure after a
disruption.
Leave that to us, the experts
grid to chip solutions, from
the biggest to the smallest
data centers, we are ready
to serve your needs with the
solutions we have developed.

More standardization,
so you dont need further
budget allocations to install it.
More simplification so you
dont need to be a specialist to
get the best for your business.
More support, so while you
are enjoying doing business,
we are protecting you.

Chloride 80-NET From 60 To 500 kW


Maximized active power,
high efficiency and complete
compatibility for modern,
mission critical IT loads.
Features and Performance
Transformer-free design
Full IGBT double conversion
technology
Full input Power Factor
Correction (PFC) and excellent
input performances:
- PF > 0.99
- THDi < 3%
Automatic output power
upgrade up to +10%
High conversion efficiency
(certified up to 98%)
Hi-tech user interface for
monitoring system status
and performance
Full galvanic isolation as
standard built-in option.

Chloride 80-NET 60 - 500 kW


Performances
Chloride 80-NET features a
transformer-free design with
full IGBT double conversion
technology allowing it to
provide extraordinary savings
on installation and running
costs, while at the same time
providing first class load
protection.
Chloride 80-NET also features
a full IGBT rectifier allowing for
reductions in the size of gen
sets, circuit protection, cabling
and transformers.
Flexibility And Compatibility
Chloride 80-NET can be fully
adapted to meet diverse
requirements in terms of
battery backup time, power,
redundancy and harmonic
control.
Maximum flexibility is also
ensured from:
Output Power Factor 1
Output Power Factor diagram
symmetrical respect to zero

Permanent 100% kVA - no


derating with any load
(lagging or leading)
Optimum space/power ratio
Full compatibility with static
transfer switches
Wide range of standard
options including: Isolation
transformer (integrated in
UPS cabinet), System Bypass
Switch and Synchronization
Module (MBSM).

User Interface
9

8
4

1. Bypass Input
Voltage, and frequency
measurements.
2. Mains Input
Current, voltage and frequency
values of the three input phases.
3. Warning/fault
Alerts of anomalies on bypass,
rectifier, inverter, booster/
charger, battery and load.

4. Events log
Date and time of important
UPS events, alarms and other
warnings.
5. Measurements
Voltage, current and frequency
values of each internal functional
block.
6. Battery
Status/values including
temperature, cell voltage, capacity
run time and testing.

7
7. LIFE
Status of the LIFE.net
connections and calls.
8. Tools
LCD settings and language
selection.
9. Output
Voltage, current, frequency,
and battery measurements.

Sustainability And Environment

Advanced digital technology


and maximum energy savings
for increased performance
and optimized TCO.
Chloride 80-NETs control
platform incorporates double
DSP and a micro-controller,
allowing it to provide the
most powerful control in the
UPS industry. Together with
the patented Vector Control
technology it enables an
increased performance of power
converters and real time control
of output power quality.
This combination of technology
provides the following benefits:
Zero impact on upstream
equipment
Perfect compatibility with
generators
Enhanced performance for
specific unbalanced load
conditions
Perfect load sharing for
parallel configurations
Enhanced fault clearing
capacity (up to 300% of the
inverter nominal current)
Intelligent double conversion
for maximum reliability and
highest energy savings.

Maximum Energy Savings


As a result of the transformerfree architecture and intelligent
double conversion technology,
Chloride 80-NET can achieve
optimum efficiency values in all
operating conditions, making
it capable of reducing running
costs also at partial load.
This architecture also allows for
reduced energy dissipation (kW)
thus significantly minimizing
the consumption of the cooling
system.
Full Galvanic Isolation
Chloride 80-NET is the only UPS
in its power range that offers
integrated full galvanic isolation,
meaning that the isolation
transformer is housed inside the
UPS cabinet. This greatly
reduces the footprint thus
providing space saving
advantages. In addition, the
transformer can be connected to
the input or to the output of the
UPS, providing:
Full galvanic isolation for
medical and other critical
applications
Installation with two
independent input sources
(with different neutrals)
Installation in distribution
without neutral.

Efficiency (%)
98

0 50

75 100

Load (%)

Chloride 80-NET efficiency curve

UPS with isolation transformer

Respecting The
Environment
Chloride 80-NET respects the
highest level of environmental
standards as a result of the
following features:
Premium energy savings
Most silent UPS in its power range
Maximized battery life with
Advanced Battery Care (ABC).
ABC allows the Chloride 80-NET
series to maximize the running time
of the battery by up to 50% and
includes the following main battery
care features:
Ambient temperature
compensated battery charger
Automatic battery test (can be set
by user at selectable intervals)
Time compensated end of
discharge voltage
Exact determination of remaining
battery life thanks to sophisticated
algorithms able to analyze real
operating conditions such as
temperature, discharge/charging
cycles and discharge depth.

Servicing Critical Infrastructure


Proactive equipment maintenance reduces downtime and extends
equipment life which in turn maximizes return on investment and
increases system availability. Emerson Network Power supports entire
critical infrastructures with an extensive service offering, guaranteeing
network availability and total peace of mind 24/7.
Our approach to servicing critical infrastructure covers all aspects of
availability and performance, from single units to entire mission critical
systems, providing customers with tailored services to meet their
individual business needs and further guaranteeing critical continuity.
Emerson Network Powers service program is designed to ensure that
your critical power protection system is maintained in an optimum state
of readiness at all times. The LIFE remote monitoring and diagnostic
service provides early warning of UPS conditions and out of tolerances.
This allows effective proactive maintenance, fast incident response
and remote trouble shooting, giving customers complete security and
peace of mind.
Maximize Availability
Pre-Emptive Maintenance
Regular preventive maintenance increases uptime. Emerson
Network Powers LIFE provides early warning of operating
anomalies allowing real-time diagnosis and swift identification
and resolution.
Minimize Downtime
Immediate Identification of Problems
Should an emergency condition arise, an engineer in the 24/7
manned LIFE service center carries out an immediate fault
analysis and instigates appropriate corrective action.
Reduce Operating Costs
Superior Asset Management
Through comprehensive data collection and analysis, LIFEs
detailed reporting system provides valuable information on
power and equipment trends, over any selected period of time.
8

Connectivity And Tracking


Interactive control, connectivity
and LIFE remote monitoring and
diagnostics allow for real time
tracking and fast intervention.
Communication
Chloride 80-NET features a hitech, 15 language user interface,
for closely controlling and
monitoring the system status
and performance.
The UPS offers the following
standard communication
features:
Voltage-free contact ports
Digital inputs and outputs
Two serial ports and LAN
connection
Two internal slots for LIFE and
connectivity options.
Hardware Connectivity
ManageUPS NET ensures the
monitoring and control of the
networked UPS, through the
TCP/IP protocol.
Two different options permit:
The integration of Chloride
UPS with Building Monitoring

and Automation Systems via


MODBUS RTU, MODBUS/TCP
or JBUS protocols
The monitoring of
environmental conditions where
the UPS systems are installed.
Software Connectivity
MopUPS Professional provides
the safe shutdown of the
operating system in the event of
an interruption to the load.
This includes event logging and
gives notifications via e-mail.
ManageUPS CIO software
provides a central management
system for critical power
infrastructures distributed within
a building, campus or wide area
network environment.

Hardware Connectivity

Servicing And Security


The Chloride 80-NETs modular
drawer-design allows modules to
be removed easily by extracting
the drawers from the front of the
UPS.
This architecture considerably
minimizes the time needed for
repairs and optimizes
installation and serviceability.
Each UPS will be equipped with
an ID card, including all UPS
working parameters. This card,
univocally related to the UPS,
shortens UPS off time in the
case that the control board
needs to be replaced.

Trellis Platform
Emerson Network Powers
Trellis platform is a real-time
infrastructure optimization
platform that enables the unified
management of data centre IT and
facilities infrastructure.
The Trellis platform software
can manage capacity, track
inventory, plan changes, visualize
configurations, analyze and
calculate energy usage, and
optimize cooling and power
equipment as well as enable for
virtualization.
The Trellis platform monitors
the data center, providing a
thorough understanding of
system dependencies to help IT
and facilities organizations keep
the data center running at peak
performance. This unified and
complete solution, delivers the
power to see the real situation in
your data center, make the right
decision and take action with
confidence.

ID card

Flexibility And Security

Parallel Configurations
Chloride 80-NET can be connected with up to eight units in parallel for an increased level of capacity as well as
redundancy, thus enhancing its fault management capability by preventing a single point of failure. The parallel
architecture of Chloride 80-NET allows single units to be serviced while the remaining units continue to power the load.
A single Chloride 80-NET unit can be upgraded to parallel simply, via dedicated and easy to modify software settings.
Chloride 80-NETs self configuring, hot plug parallel feature allows the system to automatically detect when new
units have been added without the need for stopping the system. This simplified parallel process provides maximum
flexibility in terms of scalability for capacity and redundancy.
The Loop CAN BUS connection, used to connect the paralleled UPS also allows for unprecedented reliability, perfect load
sharing and fast detection of any variation in status of the UPS system.
Chloride 80-NET can support both distributed and centralized parallel configurations:

Distributed Parallel Configuration


Paralleling single Chloride 80-NET
units offers advanced scalability. In
a distributed parallel configuration
each unit has a dedicated static
bypass switch, providing parallel
operation without the need for
a system control cabinet, thus
reducing initial installation costs.

AC Bypass
AC
Mains

AC
Mains

AC
Mains

AC
Mains

AC
Mains

AC
Mains

AC
Mains

AC
Mains

Load

Chloride 80-NET distributed parallel configuration, with 8 UPS units in parallel.

Centralized Parallel Configuration


With the Chloride 80-NETs
centralized parallel configuration,
the internal static bypass switch of
each unit is disabled and an external
Main Static Switch (MSS) rated for
the desired maximum capacity, is
installed. Therefore, the reserve
supply to the loads operates via one
central piece of equipment (MSS).
The MSS can be easily integrated
into any switchgear, thus simplifying
cabling and installation. System level
commands are given to the MSS via
its integrated touch screen display.
10

AC
Bypass

AC
Mains

AC
Mains

AC
Mains

AC
Mains

AC
Mains

AC
Mains

AC
Mains

MSS

Load

Chloride 80-NET centralized parallel configuration, with MSS plus 8 UPS units in parallel.

AC
Mains

Intelligent Paralleling Feature


for Centralized Parallel
Configuration
Activating the the Main Static
Switch (MSS) intelligent paralleling
feature optimizes efficiency at
partial load, thus achieving superior
running cost savings. Enabling
this feature allows the system to
automatically adapt capacity to
meet immediate load requirements
by switching excess units to standby
mode, while ensuring continued
system availability. Furthermore,
the Main Static Switch allows each
Chloride 80-NET unit to operate in
standby mode for the same amount
of time, ensuring an equal life-span
of module components.
This Main Static Switch intelligent
paralleling feature further maximizes Chloride 80-NETsdouble conversion efficiency at partial load and
allows for an overall energy dissipation reduction.

MSS

65%

Chloride 80-NET Intelligent Paralleling mode in centralized parallel configuration with MSS
Two units @65% load each = 95 % efficiency.

100%

Efficiency (%)

95%
90%
85%
80%

0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Load (%)

Chloride 80-NET AC/AC efficiency with MSS Intelligent Paralleling feature.

Intelligent ECO Mode for


Centralized Parallel
Configuration
In a centralized parallel
configuration it is possible to
activate the intelligent ECO mode
feature, thus powering the critical
loads through the central main
static switch, allowing it to operate
at an efficiency up to 98.5%, further
maximizing energy savings for an
optimized total cost of ownership
(TCO).

100%

Efficiency (%)

95%
90%
85%
80%

0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Load (%)

MSS Intelligent ECO mode efficiency for centralized parallel configuration.

11

Chloride 80-NET
Specifications
Technical Characteristics
Rating (from 60 - 120 kVA)

60

80

100

120

Output active power at 40 C (kW)

60

80

100

120

Apparent nominal output power at 40 C (kVA)

60

80

100

120

Apparent nominal output power at 25 C (kVA)

66

88

110

132

Input
400 (250 to 460), three phase + neutral

Nominal primary mains input voltage/voltage range (V)*


Nominal bypass input voltage/voltage tolerance (V)

400 10% (380 V, 415 V selectable) three phase + neutral

Nominal input frequency/frequency tolerance (Hz)

50 10% (60 Hz selectable)


<3

Input current distortion (THDi) (%)

>0.99

Primary input Power Factor


Output

400 (380 V, 415 V selectable) three phase + neutral

Nominal output voltage (V)


Output voltage stability by load variation 0 - 100% (%)
- static
- dynamic

1
Complies with IEC/EN 62040-3, Class 1

Nominal output frequency (Hz)

50 (60 Hz selectable)

Output frequency variation (%)


- with mains synchronization
- with internal reference

1 (2, 3, 4 selectable)
0.1
125% for 10 min., 150% for 1 min.

Inverter overload capacity

Any power factor (leading or lagging) up to 1


without output derating; crest factor up to 3:1

Compatibility with loads

110% at 25C, 100% at 40C

Automatic adjustment of nominal output power with temperature


General

VFI - SS - 111

Classification according to IEC/EN 62040-3


Operating temperature (C)

0 - 40

Relative humidity (without condensation at 20C)

<95%

Protection level

IP 20
RAL 7016

Frame Color
Noise at 1 m (dBA)*

62

62

AC/AC efficiency (%)*

up to 98%

Parallel configuration

up to 8 units

65

65

845

845

400

400

Dimensions And Weight


1780

Height (mm)
Width (mm)

570

570
858

Depth (mm)
UPS weight (kg)
* Conditions apply

12

290

290

Technical Characteristics
Rating (from 160 - 500 kVA)

160

200

300

400

500

Output active power at 40 C (kW)

160

200

300

400

500

Apparent nominal output power at 40 C (kVA)

160

200

300

400

500

Apparent nominal output power at 25 C (kVA)

176

220

330

440

550

Input
400 (250 to 460), three phase + neutral

Nominal primary mains input voltage/voltage range (V)*


Nominal bypass input voltage/voltage tolerance (V)

400 10% (380 V, 415 V selectable) three phase + neutral

Nominal input frequency/frequency tolerance (Hz)

50 10% (60 Hz selectable)


<3

Input current distortion (THDi) (%)

>0.99

Primary input Power Factor


Output

400 (380 V, 415 V selectable) three phase + neutral

Nominal output voltage (V)


Output voltage stability by load variation 0 - 100% (%)
- static
- dynamic

1
Complies with IEC/EN 62040-3, Class 1

Nominal output frequency (Hz)

50 (60 Hz selectable)

Output frequency variation (%)


- with mains synchronization
- with own reference

1 (2, 3, 4 selectable)
0.1
125% for 10 min., 150% for 1 min.

Inverter overload capacity

Any power factor (leading or lagging) up to 1


without output derating; crest factor up to 3:1

Compatibility with loads

110% at 25C, 100% at 40C

Automatic adjustment of nominal power with temperature


General

VFI - SS - 111

Classification according to IEC/EN 62040-3


Operating temperature (C)

0 - 40

Relative humidity (without condensation at 20C)

<95%

Protection level

IP 20
RAL 7016

Frame Color
Noise at 1 m (dBA)*

67

67

69

AC/AC efficiency (%)*

up to 98%

Parallel configuration

up to 8 units

70

71

1675

1900

1190

1430

Dimensions And Weight


1780

Height (mm)
Width (mm)

975

975

858

Depth (mm)
UPS weight (kg)

1675

550

632

1035

* Conditions apply

13

Chloride 80-NET Main Static Switch (MSS)


Specifications
MSS Technical Specification
Electrical Data

1000A

2000A

3000A

4000A

5000A

Nominal current (A)

1000

2000

3000

4000

5000

Power @380V (kVA)

658

1316

1975

2633

3291

Power @400V (kVA)

693

1386

2078

2771

3464

Power @415V (kVA)

719

1437

2156

2875

3594

400 (380/415)

Nominal voltage (selectable) (V)

50 (60)

Nominal frequency (selectable) (Hz)

10 ( 15)

Voltage range (selectable) (%)

1 (2, 3, 4 selectable)

Freqeuncy range (selectable)(%)

350 - 460

Maximum operating voltage range (V)


Maximum overload capacity
for 10min (%)
for 1min (%)
for 600ms (%)
for 100ms (%)

125
150

125
150

125
150

125
150

125
150

500
700

500
700

500
700

500
700

500
700

SCR
4,5*106

16,2*106

16,2*106

36*106

36*106

Itsm @ Tvj=125C; 10ms (kA)

30

57

57

85

85

Withstand rating (kArms)

50

50

50

85

85

I2t @ Tvj= 125C; 8,3-10ms (A2s)

(4)

>98

ECO mode Efficiency (%)


Transfer time when in synchro

<0.5 (no break)

Inverter to reserve (ms)

<0.5 (no break)

Reserve to inverter (ms)

<20 (selectable 0 to 20 ms)

Transfer time without synchro (ms)

Retransfer delay (s)


System Data
64

Noise @ 1 metre as per ISO 3746 (dBA 2dBA)

70
IP 20

Protection degree with open door


Mechanical dimensions:
- Height (mm)

1780

1780

- Width (mm)

1025

2422 (1200(1))

- Depth (mm)

848(2)

Weight (kg)

345

848(2)
835 (571(1))

1117 (827(1))

Not included

Switches

2,05 (1,03(1))

0.87

Floor area (m2)

397

Floor loading (kg/m )


2

Cable entry

Top / Bottom

Forced Ventilation (air flow front/bottom to top)

Ventilation

Frame color (RAL scale)

545
Top / Bottom (3)
Front and Top

Access

Air flow (when SCR are ON only) (m3/h)

407

1130

5000
7016

Environmental Data
Operating Temperature (C)
Maximum relative humidity @ 20C (non condensing) (%)
Max altitude above sea level without derating (m)
Note:
(1) Central MSS cabinet only.
(2) Including handle
(3) Top and bottom cable entry through TCE cabinets
(4) With optional fuses

14

0 - 40
Up to 95%
1000 m (for higher altitudes complies with IEC/EN 62040-3)

More than 35,000 organizations


in 70 countries depend on our expertise.

Todays successful businesses depend on adaptable technologies to help them respond quickly
to market demands. Your data center must be built on a support infrastructure designed to
match the power and cooling needs of rapidly changing IT initiatives such as virtualization and
consolidation. Each IT change, move or addition will affect the entire support infrastructure
so you need products and support that ensure your IT systems will operate reliably in these
environments.
15

Ensuring The High Availability


Of Mission-Critical Data And Applications.

About Emerson Network Power


Emerson Network Power, a business of Emerson (NYSE:EMR), is
the worlds leading provider of critical infrastructure technologies
and life cycle services for information and communications
technology systems. With an expansive portfolio of intelligent,
rapidly deployable hardware and software solutions for power,
thermal and infrastructure management, Emerson Network Power
enables efficient, highly-available networks.
Learn more at www.EmersonNetworkPower.eu

Locations
Emerson Network Power
Global Headquarters
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229, USA
Tel: +1 614 8880246
Emerson Network Power
AC Power EMEA
Via Fornace, 30
40023 Castel Guelfo (BO) Italy
Tel: +39 0542 632 111
Fax: +39 0542 632 120
ACpower.Networkpower.Emea@Emerson.com
Emerson Network Power
United Kingdom
George Curl Way
Southampton
SO18 2RY, UK
Tel: +44 (0)23 8061 0311
Fax: +44 (0)23 8061 0852

While every precaution has been taken to ensure accuracy and completeness
herein, Emerson assumes no responsibility, and disclaims all liability, for
damages resulting from use of this information or for any errors or omissions.
Specifications subject to change without notice.

MKA4L0UK80NET Rev.4-08/2015

EmersonNetworkPower.eu

Globe Park
Fourth Avenue
Marlow Bucks
SL7 1YG
Tel: +44 1628 403200
Fax: +44 1628 403203
UK.Enquiries@Emerson.com

Follow us on Social Media:

Emerson. Consider it Solved, LIFE, Trellis, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. or one of its affiliated companies
2015 Emerson Electric Co. All rights reserved.