Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Medium Voltage Controllers

Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

MEDIUM VOLTAGE CONTROLLERS

CENTERLINE

MEDIUM VOLTAGE MOTOR CONTROL

Manufacturers share the challenge of efficiently controlling


motors to improve performance, reduce power consumption
and protect motor investment. Of all the motors in your
manufacturing process, medium voltage motors can have a
large impact on your continued success. Developing
medium voltage motor control and protection has been a
core discipline for Rockwell Automation for more than
100 years. Medium Voltage products, from across-the-line
starters to soft starters and variable frequency AC drives,
deliver enhanced protection in applications ranging up to
several thousand horsepower. Bringing motors up to speed
in a controlled manner, limiting wear on the motor and
other mechanical components, and protecting your
investment are key benefits of Rockwell Automation medium
voltage systems.

O.E.M. frames and components provide OEMs and electrical


equipment companies with custom-engineered solutions and high
quality components. Both the medium voltage controller and SMC
product lines offer smaller, more flexible individual components to
reduce building and expansion costs. Open-frame style structures are
also available with most medium voltage components already
mounted within the frame. All OEM components are manufactured to
meet UL, CSA, CE and IEC standards.
Allen-Bradley medium voltage motor controllers are available
in a wide range of control formats allowing the flexibility to select
the best match for the application. Medium voltage full-voltage
controllers, reduced voltage controllers, solid-state reduced-voltage
controllers, two-speed controllers, synchronous controllers and load
break switches provide integrated intelligence and the lowest cost
solution for starting motors.

A COMPLETE LINE OF INDUCTION


AND SYNCHRONOUS CONTROLLERS

Solid-state reduced-voltage controllers apply reduced voltage to a medium voltage


AC motor to allow soft starting and stopping, limitation of the inrush current, and
reduction of the effects of water hammer in pumping systems. Allen-Bradley MV SMC Flex
controllers include motor protection, communication and diagnostic capabilities and high
flexibility, making it ideal for virtually any application.
IntelliCENTER provides MCC users with an integrated hardware, software and
communication solution. The IntelliCENTER features pre-configured software which shows
real-time data, trending, component history, wiring diagrams, user manuals and spare
parts. The IntelliCENTER reduces installation time with its plug-and-play set-up and
minimizes facility downtime by quickly providing intelligent diagnostic and predictive
failure information.

Arc resistant controllers Rockwell Automation has enhanced the safety of its world
recognized medium voltage control products to include an optional arc resistant class of
medium voltage control equipment. ArcShield controllers provide the additional arc
resistant safety features required by some industries. Most medium voltage control
products can be provided with the ArcShield enclosure design which meets the arc
resistant testing requirements of IEEE C37.20.7. ArcShield controllers use the same
standard reliable internal components that continue to serve industries world wide.

Variable frequency AC drives Allen-Bradley medium voltage drives provide a single


solution for all medium voltage speed control requirements. The PowerFlex 7000 family
of drives exceeds customer expectations by delivering superior reliability, ease of use and
lower total cost of ownership. The advanced power semiconductor technology reduces
component count to the lowest of any medium voltage drive available, translating to
increased savings and reliability, less downtime and fewer spare parts.

INTELLICENTER
INTEGRATED INTELLIGENCE WITHIN AN MCC

Built-in DeviceNet
DeviceNet ports in horizontal wireway
Simplifies installation
Complex I/O interwiring is reduced to a single DeviceNet cable
New 8 ampere, Class 1 DeviceNet cabling
Tested for noise immunity

Power Monitor 3000


Displays volts, amperes, hertz, watts, demand watts,
peak demand, kWH/kVARH, power factor
Logs min/max values, snapshot values, harmonic waveforms
Programmable outputs indicate over voltage, under voltage
and phase imbalance, loss or reversal
Communicates via Ethernet, ControlNet, DeviceNet,
Remote I/O, RS-232 or RS-485

DeviceNet Starter Auxiliary (DSA)


Interface module fon non-intelligent devices
Motor starter with eutectic alloy
Feeders and mains 4 input points
Ideal for monitoring contactor status, disconnect switch,
overload trip and Hand-Off-Auto switch

E3 Solid-State Overload Relay


DeviceNet on-board
2 or 4 input points
1 or 2 output points
Information:
Time-to-trip, time-to-reset
% thermal capacity utilized
Cause of last five trips
and warnings
Phase and average current

Protective functions
Overload, underload
Phase loss / imbalance
Stall and Jam
Ground fault (Plus version)
Settings for protective functions
Trip level, Warning level
Time delay

825-P Modular Protection System

DeviceNet communications (optional card)


Three output relays
Two configurable inputs
Ground fault CT input
Metering capability
RTD scanner module with 12 inputs (optional)

IntelliVAC Plus
Interface module for non-intelligent devices
DeviceNet communications
Eight digital inputs and two digital outputs
Provides consistent vacuum contactor control
Supports multi contactor schemes
4

IntelliCENTER Software

Spare parts lists specific to each unit


AutoCAD elevation and one-line drawings
User manuals specific to each unit
Event Logging, warnings, faults,
parameter edits

IntelliCENTER Software
Features pre-configured screens for each unit
Allows MCC monitoring from anywhere in the
users facility
Contains Active X controls to allow easy
integration into RSView

MV SMC FLEX
UNMATCHED INTELLIGENT MOTOR CONTROL

Why use Smart Motor Controllers (SMCs)


SMCs provide many features to benefit your system:
Minimize mechanical damage resulting from full
voltage starting of AC induction motors, enabling
longer system life
Limit line disturbances from inrush currents, resulting
in reduced downtime
Multiple Start/Stop modes increase functionality
Diagnostic monitoring helps prevent problems before
they occur
Satisfy electrical distribution restrictions by reducing
inrush currents
SMCs are ideal for applications where:
Belts, gears, and chains can be damaged by acrossthe-line starting
Materials can be damaged by sudden starts and stops
A step change in torque can damage equipment
Power company line current restrictions are imposed
With SMC soft starters you benefit from:
Advanced diagnostics, increasing system performance
Greater product functionality for increased system
flexibility
Decreased downtime due to advanced protection of
motor winding, equipment, and materials

The MV SMC Flex controller furnishes as


standard a full range of starting and stopping
methods for a variety of applications. Its unique
control options offer enhanced motor starting
and stopping capabilities to satisfy your most
demanding applications.

SOFT START

SOFT STOP

MV SMC Flex Smart Motor Controller offers:


Standard Control Module
Soft start - with selectable kickstart
Soft stop
Current limit start - with selectable kickstart
Linear speed acceleration * - with selectable kickstart
Linear speed deceleration
Full voltage
Preset slow speed
* requires motor tachometer

Optional Control Module


Pump control (eliminates water hammer)
- Separate start and stop profiles
Standard Features of SMC Flex Controller
Electronic motor overload protection
Metering
Diagnostics
Built-in DPI communications (other
communication options available)
Two-line, 16-character backlit LCD display
keypad programming
Three programmable auxiliary contacts
MV SMC Flex Power Module
Current loop gate drive (patented)
Efficient heat sink profile

CURRENT LIMIT

Bulletin 1560E

Bulletin 1562E

Retrofit Controller

Combination Controller

PUMP CONTROL
(Optional)

FULL VOLTAGE

LINEAR SPEED
7

ARCSHIELD

ARC RESISTANT MEDIUM VOLTAGE CONTROLLERS

The Allen-Bradley CENTERLINE ArcShield arc resistant controller provides


rugged process control for applications requiring a higher level of personnel
protection. ArcShield products are compliant to the IEEE C37.20.7 standard,
and provide Type 2B protection. The ArcShield product was tested and
certified for 40 kA and 0.5 second. During an arc flash, the ArcShield
controller safely redirects the arc flash energy out the top of the unit and
away from personnel. This level of protection is also maintained when the
low voltage door is open for maintenance purposes.

Actual photographs of successful ArcShield tests

Offering a wide variety of CENTERLINE ArcShield products:


The ArcShield products are available in a
number of different controller configurations.
Here are just a few of the products available:
Bulletin 1591A/B Incoming units
Bulletin 1512A/AT One high controller
Bulletin 1512B/BT Two high controller
Bulletin 1562E MV SMC Flex controller
Bulletin 1506 Reversing controller

Side view (common to all products)

Arc Pressure Relief Vent


Safely vents arc gases and material away from
personnel during an arc flash
Arc gases are vented out the top of the
enclosure through the plenum exhaust structure
Heavy Duty Enclosure Design
Reinforced side sheets, doors, roof, and back
plates designed to contain arc flash energy
while vents open
Added support plates secured with multiple
bolts provide increased rigidity and security

Front

Robust Power Cell Door Design


Multi-point latching mechanism,
reinforced cross bracing and gasket
sealing provide arc containment
A viewing window in the power
cell door allows the operator to
view the status of the isolation
switch before opening the door
Once the latching mechanism is
engaged, the power cell door is
bolted shut for added protection

BUILDING BLOCKS
At Rockwell Automation, we are committed to
providing the products and services that our
customers demand. Over the past eighty years,
Allen-Bradley medium voltage CENTERLINE
controllers have set the standard by which others
are measured. Our unmatched quality and
innovative designs have made us the leader in
medium voltage motor control products.

ADVANCED DIGITAL CONTROL


OF VACUUM CONTACTORS
The Allen-Bradley Bulletin 1503VC IntelliVAC
controller offers a superior and efficient means of
controlling vacuum contactors. IntelliVAC controllers
are a quantum leap beyond traditional
electromechanical control circuits. Here are just a few
of the beneficial characteristics:
The performance and flexibility of digital control,
allowing the control of a wide array of contactor
types (400A, 800A electrically held, and
mechanical latch)
Enhanced reliability as a result of embedded self
diagnostics and better coordination between unit
power fuses and the vacuum contactor drop-out time
Increased productivity with features like power loss
ride through (TDUV) and contactor anti-kiss, which
were previously offered as optional features
Motor and process protection with delayed restart
built-in

NON-LOAD BREAK ISOLATION SWITCH


Electrical and mechanical interlocks prevent the switch from
opening when the contactor is energized
Ensures normal operation only when the switch is fully closed
Allows for separate source testing when in the OFF position
Grounded in the OFF position
When in the open position, a visible barrier isolates the power cell
from the power bus compartment
Status of the isolation switch can be viewed through a window in
the power cell door

HANDLE AND INTERLOCK MECHANISM


Simple direct drive mechanism improves reliability and ensures
operator safety
Mechanical interlock mechanism remains part of the enclosure
to eliminate setup adjustment
Power cell door is interlocked with the handle mechanism to
prevent the door from being opened when the cell is energized

LOW VOLTAGE COMPARTMENT


Separate 120 volt source is required for Test position
control power
Allows testing and troubleshooting of the power cell without
exposing personnel to medium voltage
Prevents backfeeding medium voltage through the control
transformer, in Test mode
All low voltage components are located in the low voltage panel
Low voltage panel interior painted white for better visibility

POWER CELL COMPARTMENT


Power cell, low voltage panel, and bus compartment are isolated
from each other for better fault containment
Swing out low voltage panel for easy access to install load cables
Isolated load cable compartments between top and bottom
power cell
Easy access for cable installation and stress cones
Bar type current transformers are supplied as standard for
overload protection and metering

POWER BUS COMPARTMENT


CENTERLINE bus designed as an integral part of the structure
Dissipates heat more efficiently
Edge-to-edge configuration maximizes resistance to magnetic
forces and minimizes moisture or dust collection
Molded bus brace reduces maintenance and provides better
distribution of forces during a fault
Accessible without a ladder, for installation and maintenance
Allows for incoming line cables to enter through the top or
bottom of the compartment

11

INTELLIGENT
MOTOR CONTROL
OPTIMIZE PLANT PERFORMANCE & PROTECT YOUR INVESTMENT

We understand that you need to control performance, reduce


downtime, improve safety, increase productivity, and perform
diagnostics. Thats why weve combined leading-edge motor control
and protection devices with the advanced networking and diagnostic
capabilities of Rockwell Automations Integrated Architecture to
provide you with Intelligent Motor Control.

PROTECTION
Thanks to integrated I/O and advanced diagnostic and protection
capabilities, all Intelligent Motor Control products constantly
monitor the motor operation to help you follow performance trends
and take remedial action before potential failures occur. Reduce
unwanted downtime by 75% while increasing overall production
efficiency by 10% or more.

12

COMMUNICATIONS
Because you have a wide range of
application needs, Intelligent
Motor Control offers a variety of
motor control technologies.
Simplified control technologies are
designed to suit your needs
DeviceLogix component
technology increases the control
PowerFlex 7000
One-High MV SMC Flex IntelliCENTER
possibilities with function block
Controller
Controller
AC Drive
Controller
diagrams that operate at the
device level
SCALABLE FUNCTIONALITY
DriveLogix offers embedded Login control
for application programmability and control of
auxiliary functions in one package
Integrated Architecture enables you to reduce your total cost of
ownership by using a single control infrastructure for the entire range of
factory automation applications, large or small
Reuse engineering designs and practices to reduce development time
and cost
Quickly respond to customer or market demands
Reduce maintenance costs and downtime
Easily access plant and production data from business systems
or better management decision-making

COMMUNICATIONS
The key to intelligence in motor control...
Utilize open networked architecture to enhance
motor protection, share diagnostic information
and speed troubleshooting for a more productive,
intelligent process.
From simple I/O to complex power monitoring
tasks, DeviceNet lets your cost effectively
integrate many low-level manufacturing functions
NetLinx open network technology provides
seamless communications throughout your
enterprise (DeviceNet, ControlNet, and EtherNet/IP)
Flexibility and commonality of communications
across the product offering makes Intelligent Motor
Control easy to use

O.E.M. PRODUCTS
QUALITY COMPONENTS FOR THE OEM MARKET

OEM Frames and components leverage the existing family of motor controllers built by Rockwell
Automation. They also incorporate some of the most fundamental, high volume components available
in our OEM product line for Original Equipment Manufacturers and electrical equipment companies.
Bulletin 1502 vacuum contactors are a comprehensive line of vacuum contactors used as isolating
contactors or as bypass contactors. Light weight and maintainability are but two of the features of this
fixed-mounted design.
Bulletin 1503F OEM components are a series of medium voltage frame-mounted components designed
to mount into new or existing structures or enclosures. These assemblies can also be used to retrofit
existing motor controllers. These products are available as a complete OEM frame or sold individually
as components.
Bulletin 1503E MV SMC Flex OEM kits are a series of solid-state reduced voltage components
designed to mount into new or existing structures or enclosures. These assemblies can also be used to
retrofit existing motor controllers. These products are available as an OEM frame and components.
The Bulletin 857 motor and feeder protection device includes all the essential protection functions
needed to protect feeders and motors in distribution networks of utilities, heavy industry, power plants
and offshore applications. The Bulletin 857 can also be used to retrofit existing motor controllers.
The IntelliVAC control module is an efficient and flexible solution for controlling medium voltage
contactors used in motor starter and feeder applications. The IntelliVAC control model manages 400
and 800 amp contactors, as well as both electrically-held and
mechanically-latched contactor types.
The IntelliVAC Plus is an enhanced version of the IntelliVAC
control module. Some of incremental benefits are DeviceNet
communications (including IntelliCENTER software
compatibility), digital I/O (8 inputs and 2 outputs),
DeviceLogix control and enhanced diagnostics.

General Features

Medium Voltage Motor Controllers

Description of Features
Designed for Safety, Convenience and Reliability

IntelliVAC control module for each vacuum contactor, mounted


in low voltage panel, with advanced features:
Universal input voltage (110-240V AC, 50/60 Hz or 100-250V DC)
Selectable vacuum contactor drop-out time and consistent
pick-up time
Altitude compensation
Power loss ride-through (TDUV) may require additional
hardware (external capacitor)
Anti-kiss and anti-plugging protection
Delayed motor re-start and temporary motor jog function
One device is suitable for all contactors and control schemes

The Allen-Bradley medium voltage controller offers:


Three isolated compartments:
- Power bus
- Low voltage
- Power cell
Large swing-out low voltage panel painted white for high
visibility
Test circuit and plug for remote control power supply
External operating handle to operate the isolation switch
Bolted power cell door(s)
Centerline horizontal power bus with removable cover plates
for accessibility
1/4 x 2 continuous copper ground bus
Line, load and control wire conduit openings with removable
cover plates at the top or bottom of the structure
Base mounting sill channels with mounting holes and removable
lifting means
Hybrid epoxy powder paint finish

Input Voltage

Controller Standard Features

NEMA Class E2 design


Removable lifting angles or brackets
Non-removable sill channels
Removable backplates
Top or bottom plates to accommodate cable entry/exit
Tin-plated copper horizontal power bus located in an isolated
compartment
A x 2 continuous bare copper ground bus
A main non-load break isolation switch with visible blades
and shutter mechanism, and operating handle
Mechanical and electrical interlocks between isolation switch,
vacuum contactor and MV door
Vacuum contactor(s)
Three (3) current limiting power fuses for NEMA Class E2
operation
Three (3) current transformers
Control circuit transformer with primary and secondary fuses
A low voltage control panel
Space for necessary auxiliary control and metering devices
Polycarbonate viewing window in power cell door

2400V, 3300V, 4200V, 6600V or 6900V AC (+5/-10%)


3 phase 50/60 Hz ( 3%)

Ambient Temperature
0C to 40C (32F to 104F) with relative humidity of
up to 95% (non-condensing)

Enclosure Types
NEMA Type 1 General purpose (IP10)
NEMA Type 1 w/g General purpose with gasket (IP21)
NEMA Type 12 Dust-tight and drip proof (IP52)
NEMA Type 3R Non walk-in weatherproof (IP34)
Arc Resistant (NEMA Type 12) Accessibility Type 2B
Tested per IEEE C37.20.7-2001

Standards
Canadian Standards Association (CSA),
Industrial Control Equipment C22.2 No. 14 and TIL D-21
American Nation Standards Institute (ANSI),
Instrument Transformers C57.13
Institute of Electrical & Electronic Engineers (IEEE)
National Electrical Code (NEC)
Occupational Safety & Health Act (OSHA)
Guide for Harmonic Control and Reactive
Compensation of Static Power Converters (IEEE 519-1992)
National Electrical Manufacturers Association (NEMA),
Medium Voltage Controllers Rated 1501 to 7200 V AC ICS 3-2
(formerly ICS 2-324)
Underwriters Laboratories, Inc. (UL),
High Voltage Industrial Control Equipment 347
European Directives for EMC

Visit our Web site: www.ab.com.catalogs

15

General Features

Medium Voltage Motor Controllers


Description of Features (cont.)
Paint Finishes
Description
Color
Procedure
Preparation

Painting

Baking

Hybrid epoxy power paint


ANSI 49 medium light grey (standard)
ANSI 61 light grey (optional)
Continuous paint line. All parts are painted
before assembly
Alkaline wash/rinse/iron phosphate
rinse/iron-chrome sealer
rinse/recirculated de-ionized water
rinse and virgin de-ionized water rinse
Air-atomized electrostatic spray
Total paint thickness 0.002
(0.051 mm) minimum
Natural gas oven at 179C (355F) minimum

Power Bus (Optional)


Located at the center rear of the structure
Mounted on the edge to a molded bus support insulator
in a common vertical plane
Centerline horizontal tin-plated copper bus
optional silver-plated or insulated
1200/2000/3000 A
Front/rear access

Ground Bus
Continuous bare copper ground bus 6 x 52 mm (1/4 in x 2 in)
as standard
#8 - #1/0 AWG or #6 250 MCM mechanical lug
supplied at the incoming end of the lineup

16

Visit our Web site: www.ab.com.catalogs

Bulletin 1500

Medium Voltage Controller Components


Description of Features

Operating Handle and Interlock Mechanism

The Rockwell Automation Medium Voltage Controller,


Bulletin 1500, is comprised of three core elements:

Simple direct drive mechanism improves reliability and ensures


operator safety
Mechanical interlock mechanism remains part of the enclosure to
eliminate setup adjustment

Power cell compartment


Low voltage compartments
Power bus compartments

Power cell door is interlocked with the handle mechanism to


prevent the door from being opened when the cell is energized

Power Cell Compartment


Isolation Switch
Electrical and mechanical interlocks prevent the switch from
opening when the contactor is energized
Ensures normal operation only when the switch is fully closed
Allows for separate source testing when in the OFF position
Grounded in the OFF position

Current Transformers
Three (3) current transformers are supplied as standard
for overload protection and metering
Five (5) amp secondary output

Visible Isolation
When in the open position, a visible barrier isolates the power cell
from the power bus compartment
Status of the isolation switch can be viewed through a window in
the power cell door

Isolated Cable Ducts

Control Power Transformers

Easy access for cable installation

110/120 or 220/240 V AC

Ample room for stress cones

500 VA as standard with 350 VA extra capacity

Provides isolated load cable compartments between top and


bottom power cells

Appropriately sized primary and secondary fuses


1000 VA, 2000 VA, and 3000 VA CPTs (optional)

Vacuum Contactor
Modular design for simplified maintenance and reliability
Fixed mounted design eliminates hot spots and
reduces maintenance
Visible contact wear indicator eliminates the need for special tools

Swing-out Low Voltage Panel (for 2-high structure)


Allows for easy access to install load cables
Maximizes low voltage panel space

Visit our Web site: www.ab.com.catalogs

17

Bulletin 1500

Medium Voltage Controller Components


Power Bus Compartment

Description of Features (cont.)

Centerline Bus Design


Designed as an integral part of the structure

Low Voltage Compartment

Dissipates heat more efficiently


Edge-to-edge configuration maximizes resistance to magnetic
forces and minimizes moisture or dust collection
Molded bus brace reduces maintenance and provides better
distribution of forces during a fault
Accessible without a ladder, for installation and maintenance
Allows for incoming line cables to enter through the top or bottom of
the compartment

Low Voltage Compartment Control Panel


Separate 120 volt source is required for Test position control
power
Allows testing and troubleshooting of the power cell without
exposing personnel to medium voltage
Prevents backfeeding medium voltage through the control power
transformer, in Test mode

Isolated Compartment
All low voltage components are located in the low voltage panel
Low voltage panel interior painted white for better visibility
Power cell, low voltage panel, and bus compartment are isolated
from each other for better fault containment
IntelliVAC control module

18

Visit our Web site: www.ab.com.catalogs

Bulletin 1500

Medium Voltage Controller Components IntelliVAC Family


IntelliVAC Control Module
The IntelliVAC control module has a universal input voltage range
(110 - 240 VAC, 50/60 Hz or 110 - 250 VDC)
Consistent vacuum contactor pick-up time, ensures optimal
synchronization
Selectable and repeatable vacuum contactor drop-out times (50,
75, 100, 130, 150, 175, 200 or 240 msec) for tighter coordination
with power fuses
Altitude compensation ( -1,000 to 5,000 meters) eliminates
mechanical hardware changes at high altitude (400 Amp vacuum
contactors)
Power loss ride-through logic (TDUV) with selectable drop out time
(0.2, 0.5, 1.0 or 2.0 sec) requires only an external capacitor
Anti-kiss and anti-plugging protection
IntelliVAC

IntelliVAC Plus

Status indication (LEDs and relay outputs) allows integration in


control system and aids troubleshooting
Temporary motor jog function (separate input) to allow process
set-up

Description of Features
The Allen-Bradley Bulletin 1503VC family of IntelliVAC controllers
offers a superior, efficient and flexible means of controlling vacuum
contactors. The IntelliVAC family offers a scalable solution for
multiple medium voltage control applications. The IntelliVAC family
has three main products:
IntelliVAC provides basic control capabilities for 400 and 800 Amp
contactors (electrically held and mechanical latch) using a single
device. It offers enhanced reliability through better diagnostics and
coordination between the power fuses and the vacuum contactor
drop-out time. Productivity is improved using the power loss ride
through (TDUV) and contactor anti-kiss and anti-plugging features.
IntelliVAC Plus builds on IntelliVAC with incremental benefits such
as DeviceNet communication (including IntelliCENTER software
compatibility), digital I/O (8 inputs, 2 outputs), DeviceLogix
control and enhanced diagnostics.
IntelliVAC MC is used in multi-contactor applications, allowing
one IntelliVAC Plus to control up to four IntelliVAC MC control
modules in a Master-Slave configuration. Control and timing logic
is handled in DeviceLogix, minimizing control hardware and wiring.
IntelliVAC controllers are designed to perform with Bulletin 1502
vacuum contactors. These industry-proven contactors are available
in 400A and 800A ratings up to 7,200 volts.

Delayed motor re-start prevents rapid cycling of vacuum contactor,


protecting the connected motor

IntelliVAC Plus Control Module


The IntelliVAC Plus control module has the same feature as the
IntelliVAC, with the additional capabilities below:
DeviceNet communication
DeviceLogix control
Digital inputs (8), rated for 110 to 250 VAC or VDC, and outputs (2),
rated up to 250 VAC or FDC, with all LEDs indicating status
Support for multi-contactor (MC) control schemes, with up to four
slave IntelliVAC MC units connected on RS485, and DeviceLogix
pre-configured for standard MV controller logic (can also define
Custom MC control configurations)
Enhanced operational information and diagnostics with features
like real-time clock, extended contactor close time monitoring and
tracking of contactor usage
IntelliCENTER software compatibility
Configurable using either RS Networx or handheld configuration
terminal (Bulletin 193-DNCT) for DeviceNet

IntelliVAC MC Control Module


The IntelliVAC MC control module has the same feature as the
IntelliVAC, with the additional capabilities below:
Communication board (RS485) to allow the MC module to
be controlled by one IntelliVAC Plus for multi-contactor control
schemes

Visit our Web site: www.ab.com.catalogs

19

Bulletin 1500

Medium Voltage Controller Components IntelliVAC Family


Specifications

20

Visit our Web site: www.ab.com.catalogs

Bulletin 1500

Medium Voltage Controller Components Vacuum Contactors


Applications
Medium Voltage (1,000 to 7,200 V) vacuum switching for:
Motor Starters (asynchronous, synchronous)
Full voltage
Reduced voltage
Variable frequency drives
Transformer feeder units
Capacitors

Product Approvals

UL347
CSA 22.2 No. 14 and TIL D-21
IEC 60470
CE Mark

Modular Construction

Description of Features
The Allen-Bradley vacuum contactors are designed as fixed
mounted devices for heavy-duty industrial performance. This design
eliminates the worries typically associated with drawout contactors.
The compact design of the contactor eliminates the need for it to be
removed from the power cell. Also there are no drawout stab and
finger assemblies, which require routine maintenance.
The Series E contactors are designed for operation with Rockwell
Automations IntelliVAC family of control modules.

Designed to be interchangeable with other contactors of the same


rating
Horsepower rated devices are located elsewhere in the power cell,
not on the contactor
Easily removed for maintenance and repair

Vacuum Bottles

Designed to industry specifications


Arcing confined inside vacuum bottle for ionized gas protection
Mounted on the front of the contactor for visible inspection
Contact wear indicators located on the bottle eliminates the need
for special tools
Excellent dielectric recovery provides high switching frequency

Advantages

Lightweight, compact design


High interrupting capability
Low chop current
Visual contact wear indicator (no measurement tools required)
Provisions for mechanical interlocking (to isolation switch)
Excellent dielectric recovery allowing for high switching frequency
Single coil/core magnet assembly (800 A only)
Control power transformer primary fuse holders (400 A only)
Minimal maintenance required
All major components are easily accessed from the front
Mechanical latch design (optional)
Easily integrated into control circuit with quick connector and wire
harness (optional)
Designed to complement the advanced features of the IntelliVAC
contactor control module

Long Electrical and Mechanical Life


1,000,000 electrical operations (400 A)
2,500,000 mechanical operations (400 A)

Visit our Web site: www.ab.com.catalogs

21

Bulletin 1500

Medium Voltage Controller Components Vacuum Contactors


Specifications
Bulletin 1502 Medium Voltage Contactor Ratings

400 A

Voltage Ratings
Maximum Rated Voltage

7200
2400
4800

System Voltages
Dielectric Voltage Withstand Rating
Basic Impulse Level (B.I.L.) Withstand
Frequency Ratings
Current Ratings
Rated Open Continuous Current
Maximum Interrupting Current Rating
(RMS Sym Amps)
Maximum Interrupting MVA Rating
(Sym MVA)
Short-Circuit Withstand at Rated Voltage
Short Time Current Rating Capability

For 60 seconds (kV)


Phase to Ground, Phase to Phase (kV)
Hertz

7200
4160
6900
60
50/60

400
6300
6300
6000
25
50
75
60
6.0
2.4
0.5
4.0
40

800
12500
12500
12500
50
100
150
85
12.0
4.8
0.5
8.0
40

4.3
.248
95
75
5.5
70

12
0.7
95
75
5.2
70

2500
100
1000
600
150
800
1400
2000

250
100
250
600
150
2000
3000
4000

-1000 to 5000 /
-3300 to 16500
21.8 / 48
A600
3 N.O. / 3. N.C.

-1000 to 5000 /
-3300 to 16500
45 / 100
A600
3 N.O. / 3. N.C.

2400 V
5000 V
7200 V
2400 V
5000 V
7200 V
Current Peak cycle (kA)
For 1 second (kA)
For 30 seconds (kA)

System Voltage

3300
6600
18.2 / 20 kV (IEC)

60
50/60

Chop Current (Average RMS Amps)


Make and Break Capability at Rated Voltage (kA)
Ambient Temperature
C
Contactor Coil Data
Close Current (ADC, 200 ms)
V AC:
Hold Current (ADC)
110 to 240 V AC
VCL = 2 x V CTL
or
Pick-up Voltage
(Max.)
110 to 250 V DC
Drop-out Voltage
V DC:
Trip Current (ADC, 200 ms)
VCL = V CTL
Trip Voltage
Operational Characteristics
Electrically Held
Mechanical Life (Operations) x 1000
Mechanical Latch
Electrical Life (Operations) x 1000
Electrically Held
Switching Frequency (Operations per hour)
Mechanical Latch
Capacitor Switching (max. kVAR)

800 A

2400 V
4160 V
6900 V

General
Standard Altitude Capabilities (meters / feet)
Contactor Weight (kg / lbs)
Auxiliary Contact Rating
Auxiliary Contacts on the Vacuum Contactor (max.)

The voltage and current ratings listed are valid up to 1,000 m (3,300 feet).
The IEC rating at 7200 V (RMS Sym.) is 5300 amps / 66 MVA.
Provided that regular maintenance is performed, as detailed in publication 1500-SR020_-EN-P.
The full altitude range is available with the IntelliVAC control module only, and the IntelliVAC is to be configured accordingly (refer to publication 1503-UM051_-EN-P).
The standard mechanical latch contactors, if used with electro-mechanical control, are designed for -1000 to 1000 meters (-3300 to 3300 feet).
Higher altitudes are possible by changing the contactor return springs.
The number of contactor auxiliary contacts depends on the contactor type. Some of the contacts are used in the typical control schemes.
Control voltage, as measured at the input of the IntelliVAC module.
Applicable to mechanical latch contactors only.
Altitude is field adjustable using a mechanical arrangement.

22

Visit our Web site: www.ab.com.catalogs

Bulletins 857 and 865

Key Rockwell Automation Options Modular Protection System


Description of Features

The Allen-Bradley 857 motor and feeder protection relay includes the
essential functions needed to protect motors and feeders in diverse
industrial applications. The programmable Bulletin 857 includes the
optional arc protection feature, thermal, trip circuit supervision and circuit
breaker protection. The device can include numerous communication
protocols, as well as a twelve-channel RTD scanner mounted up to
1000m from the relay, with a fiber optic connection to the relay.

The Allen-Bradley Bulletin 865 differential protection relay includes


the necessary functions to protect transformers for distribution
networks of utilities, industry power plants and offshore applications,
as well as motor and generator differential protection. The devices
programmable functions include thermal and circuit breaker protection,
and numerous communication protocols. An optional arc flash
protection system is available.

Description of Relay Features for Bulletin 857 and 865


Fully digital signal handling utilizing a 16-bit microprocessor with high
measuring accuracy on all the setting ranges through the utilization of
a 16-bit A/D conversion technique.
Wide setting ranges for the protection functions can reach
sensitivities up to 0.5% accuracy
Capable to disable certain Functions and Protection Elements for
specific applications.
The control of up to six external objects (e.g. circuit-breakers,
contactors disconnects)
Ability to actively display the status of eight objects on the local
display panel (e.g. MIMIC for circuit breakers, contactors disconnects,
switches, etc.)
Capable of freely configuring of the Local Display with six selectable
measurement values
All settings, events and indications are stored in non-volatile memory
Easily configuration from the Local Display or with the free
SetPointPS user software
Include a built-in, self-regulating, AC/AC power Supply with an
operating range from 40-265 VDC or VAC.

Visit our Web site: www.ab.com.catalogs

23

Bulletin 825-P

Key Rockwell Automation Options Modular Protection System


Description of Features
Converter Modules
Compact Three-Phase current transformer modules
Provides electrical isolation
Six current ranges
0.5 to 2.5 A
2.5 to 20 A
20 to 180 A
160 to 630 A
Compatibility with MCS PLUS Bulletin 100-D contactors

Core Balance Current Transformer


Sensitive, low level ground fault detection
100:1 ratio
110 mm window opening
The Bulletin 825-P Modular Protection System for motors offers a
compact, modular design that uniquely allows an installer to configure a
devices functional capabilities to match the application requirements.

Note: The 825-P is compatible with core balance current transformer


ratios of 1:1 to 2000:1.

Flexibility is also afforded by accommodating future expansion of the


system as the application requirements grow. Ease of installation is
provided through pluggable options and accessories.

RTD Scanner Module

Finally, this next generation design offers greater capabilities with the
option of full metering for line voltage and power monitoring in addition
to expanded RTD monitoring.
The 825-P Modular Protection System is a key component to Bulletin
1500 medium voltage controllers.

System Overview
Basic Unit
0.5 to 5000A Current Range
Suitable for Low- and Medium-Voltage Applications
Built-in Keypad and Backlit 2-Line LCD
Test / Reset Button
Status LEDs
Front accessible RS 232 port
Wide Supply Voltage Range (110...240V AC/DC)
Three Output Relays
Two Configurable Inputs
PTC thermistor Input
Core Balance Current Transformer Input
Fiber Optic Port for Remote RTD Scanner
Three option card slots
NEMA 12 (IP65) Housing

24

12-channel inputs
Compatible with 100 Platinum, 100 Nickel, 120 Nickel,
and 10 Copper type RTDs
Can be remote mounted near the motor, simplifying wiring
Class 1, Division 2, Group T4A rated
Noise immune fiber optic connection to the Basic Unit
Channels are individually configurable for RTD type and location
(winding, bearing, ambient, or other).

Option Cards
Voltage Input
Input terminations for VA, VB, VC and VN
Enables voltage and power measurement and related protection
functions
Accommodates potential transformers for levels exceeding 250V AC
DeviceNetor Modbus Communications
Direct network access for control and monitoring
DeviceNet communications card features DeviceLogix component
technology for enhanced control capability
DeviceNet communication card provides compatibility with the
IntelliCENTER software
Expansion I/O
Three Configurable Inputs
Four Auxiliary Relay Outputs
4 to 20mA Isolated Analog Output

Visit our Web site: www.ab.com.catalogs

ArcShield

The ArcShield products have a robust enclosure design which contain


the arc flash energy and exhaust materials until vents on top of the
enclosure open. Once opened, the vents provide a path for materials
to exit the enclosure. An overhead plenum is used to direct the
materials to a safe location, away from personnel near the equipment.
The low voltage panel is reinforced and sealed, to prevent arc flash
exhaust materials from entering this compartment.
As standard, a plenum exhaust section is provided with each new
ArcShield order. The plenum exhaust section can be mounted on
either the left or right end of the line-up, and it extends 40 inches (or
1016 mm) past the end of the line-up.
As the ArcShield may have an impact on horsepower ratings, please
contact your Rockwell Automation office to confirm.
Engineered Features
Reinforced cabinet and power cell door closure mechanism
Multi-point latching mechanism, reinforced cross bracing and
gasket sealing

Description of Features
The Allen-Bradley Centerline ArcShield arc resistant controller provides
rugged process control for applications requiring a higher level of
personnel protection. ArcShield products are compliant to the IEEE
C37.20.7 standard, and provide Type 2B protection during an arc flash.
The ArcShield controller safely redirects the arc flash energy out the
top of the unit and away from personnel. This level of protection is
also maintained when the low voltage door is open for maintenance
purposes.

Reinforced back plates added support plates secured with multiple bolts provide increased rigidity and security
Reinforced low voltage panel to withstand arc flash energy and
shield maintenance personnel while working in the isolated low
voltage compartment
Arc Pressure Relief vent to safely vent arc gases and material
away from personnel during an arc flash
Available with removable arc exhaust plenum

Specifications
Bulletin Number
1506

1512A

1512AT
1512B
1512BT
1562E

1591A/B

Approximate Dimensions
Inches (mm)
Width

Depth

Height

Approximate
Weight
lb (kg)

36 (915)
26 (661)
44 (1118)
36 (915)
54 (1372)
62 (1575)
80 (2032)
26 (661)
36 (915)
36 (915)
54 (1372)
36 (915)
36 (915)
54 (1372)
18 (457)
18 (457)
36 (915)
36 (915)

36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)
36 (915)

128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
128.5 (3264)
91 (2315)
128.5 (3264)
128.5 (3264)
128.5 (3264)

2310 (1050)
1380 (627)
2435 (1107)
1700 (773)
2750 (1250)
3080 (1400)
4135 (1882)
1380 (627)
1700 (773)
2310 (1050)
3365 (1530)
2310 (1050)
1950 (886)
3000 (1364)
950 (432)
1020 (464)
1610 (732)
1610 (732)

Controller Size
200/400
200/400/450
200/400/450
600
600
800
800
200/400/450
600
200/400
200/400
200/400
200/400
200/400
18
18
36
36

Arc resistant with plenum


Arc resistant with plenum, plus PFCC option
Arc resistant without plenum
Arc resistant with plenum c/w low voltage panel
1591B
Added height above standard 91 for the plenum

Visit our Web site: www.ab.com.catalogs

25

Bulletin 1506

Medium Voltage Controller Full Voltage Reversing Starter


Description of Features
Fixed mounted vacuum contactors (FORWARD and REVERSE)
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
Available for motor loads
Plugging or anti-plugging duty
Mechanically and electrically interlocked contactors

400 amp

Specifications
Starter
Size
200A

Approximate Dimensions
Inches (mm)

Maximum Horsepower
2400V

3300V

4160V

4800V

Width

Depth

800

1000

1250

1500

36 (915)

36 (915)

91 (2315)

1770 (802)

91 (2315)

1770 (802)

400A

1500

2250

2750

3000

36 (915)

36 (915)

800A

3500

5000

6000

7000

56 (1422)

36 (915)

Height

91 (2315)

Height is 128.5 inches (3254 mm) with ArcShield enclosure and plenum.
Weight will be different with ArcShield.

Power Circuit Schematic 1506

26

Approximate
Weight
lb (kg)

Visit our Web site: www.ab.com.catalogs

1950 (885)

Bulletin 1512A

Medium Voltage Controller Full Voltage Non-Reversing (One-High) Starter


Description of Features
Fixed mounted vacuum contactor
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
(R-rated power fuses used for 450 A, 600 A and 800 A starters)
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
1-high structure design for one complete motor controller
Available in optional ArcShield enclosure
Also available as Prepared Space (Bulletin 1512AP, 200A and 400A
only) or Starter Kits (Bulletin 1512AS)

400 Amp

Specifications
Starter
Size

Approximate Dimensions
Inches (mm)

Maximum Horsepower

Width

Depth

Height

Approximate
Weight
lb (kg)

2400V

3300V

4160V

4800V

6600V

6900V

200A

800

1000

1250

1500

2250

2500

26 (661)

36 (915)

91 (2315)

400A

1500

2250

2750

3000

4500

5000

26 (661)

36 (915)

91 (2315)

1075 (490)

450A

1750

2500

3000

3500

N/A

N/A

26 (661)

36 (915)

91 (2315)

1075 (490)

1075 (490)

600A

2750

3500

4500

5500

N/A

N/A

36 (915)

36 (915)

91 (2315)

1350 (611)

800A

3500

5000

6000

7000

9000

9000

56 (1422)

36 (915)

91 (2315)

1800 (816)

Height is 128.5 inches (3264 mm) with ArcShield enclosure with plenum
Weight will be different with ArcShield.

Power Circuit Schematic 1512A

Visit our Web site: www.ab.com.catalogs

27

Bulletin 1512AT

Medium Voltage Controller Full Voltage Transformer Feeder Unit Starter

Description of Features
Fixed mounted vacuum contactor
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) E-rated current-limiting power fuses
(R-rated power fuses used for 450 A, 600 A and 800 A starters, and
for 400 A 6600V/6900V starters)
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
1-high structure design for one complete transformer controller
Available in optional ArcShield enclosure
Also available as Prepared Space (Bulletin 1512AP, 200 A and 400 A
only) or Feeder Kits (Bulletin 1512AU)

400 Amp

Specifications
Starter
Size

Approximate Dimensions
Inches (mm)

Transformer Size (kVA)


2400V

3300V

4160V

4800V

6600V

6900V

Width

Depth

200A

700

1000

1250

1250

2000

2000

26 (661)

36 (915)

91 (2315)

1075 (490)

400A

1250

2000

2500

2750

4500

4500

26 (661)

36 (915)

91 (2315)

1075 (490)

450A

1500

2250

2750

3000

N/A

N/A

26 (661)

36 (915)

91 (2315)

1075 (490)

600A

2250

3000

4000

4500

N/A

N/A

36 (915)

36 (915)

91 (2315)

1350 (611)

800A

3000

4000

5500

6000

N/A

N/A

56 (1422)

36 (915)

91 (2315)

1800 (816)

Height is 128.5 inches (3264 mm) with ArcShield enclosure with plenum.
Weight will be different with ArcShield.

Power Circuit Schematic 1512AT

28

Visit our Web site: www.ab.com.catalogs

Height

Approximate
Weight
lb (kg)

Bulletin 1512B

Medium Voltage Controller Full Voltage Non-Reversing (Two-High) Starter


Description of Features
Fixed mounted vacuum contactor
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
2-high structure design for two complete motor controllers
Available in optional ArcShield enclosure
Also available as Prepared Space (Bulletin 1512BP) and Starter
Kits (Bulletin 1512BS)

400 Amp

Specifications
Starter
Size

Approximate Dimensions
Inches (mm)

Maximum Horsepower

Height

Approximate
Weight
lb (kg)

2400V

3300V

4160V

4800V

6600V

6900V

Width

Depth

200A

800

1000

1250

1500

2250

2500

36 (915)

36 (915)

91 (2315)

1770 (802)

400A

1500

2250

2750

3000

4000

4000

36 (915)

36 (915)

91 (2315)

1770 (802)

Height is 128.5 inches (3264 mm) with ArcShield enclosure with plenum.
Weight will be different with ArcShield.

Power Circuit Schematic 1512B

Visit our Web site: www.ab.com.catalogs

29

Bulletin 1512BT

Medium Voltage Controller Full Voltage Transformer Feeder Unit (Two-High) Starter
Description of Features
Fixed mounted vacuum contactor
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) E-rated current-limiting power fuses
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
2-high structure design for two complete transformer controllers
Available in optional ArcShield enclosure
Also available as Prepared Space (Bulletin 1512BP) or Starter Kit
(Bulletin 1512BU)

400 Amp

Specifications
Starter
Size

Approximate Dimensions
Inches (mm)

Transformer Size (kvA)


2400V

3300V

4160V

4800V

6600V

6900V

Width

Depth

200A

700

1000

1250

1250

2000

2000

36 (915)

36 (915)

91 (2315)

1770 (802)

400A

1500

2000

2500

2750

N/A

N/A

36 (915)

36 (915)

91 (2315)

1770 (802)

Height is 128.5 inches (3264 mm) with ArcShield enclosure with plenum.
Weight will be different with ArcShield.

Power Circuit Schematic 1512BT

30

Visit our Web site: www.ab.com.catalogs

Height

Approximate
Weight
lb (kg)

Bulletin 1522E/F/G

Medium Voltage Controller Two-Speed Non-Reversing Starter

Description of Features
Fixed mounted vacuum contactor
HIGH and LOW speed settings for two-speed separate winding,
Bulletin 1522E starter
HIGH/LOW speeds and HIGH SPEED SHORTING settings for twospeed consequent pole, Bulletin 1522F/G starter
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
Six (6) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
Constant or variable torque, and constant horsepower applications

400 A

Specifications
Starter
Size

Approximate Dimensions
Inches (mm)

Maximum Horsepower
2400V

3300V

4160V

4800V

Width

Depth

Height

Approximate
Weight
lb (kg)

200A

800

1000

1250

1500

36 (915)

36 (915)

91 (2315)

1770 (802)

400A

1500

2250

2750

3000

36 (915)

36 (915)

91 (2315)

1770 (802)

Power Circuit Schematic 1522E

Power Circuit Schematic 1522F

Visit our Web site: www.ab.com.catalogs

31

Bulletin 1560E / 1562E

Medium Voltage Controller SMC Flex Smart Motor Control Starter


Metering
Access locally using the controllers built-in LCD display, or remotely
through the communication port
Three-phase voltage
Three-phase current
Three-phase power (MW, MWh, power factor)
Elapsed time
Motor thermal capacity usage
Motor speed (with optional use of tachometer input)

Diagnostics

Line Fault
Power Loss
Voltage Unbalance
Current Unbalance
Ground Fault
Communication Fault
Phase Reversal

Bulletin 1562E
Combination Controller

Undervoltage
Jam
Overtemperature
Stall
Open Gate
Overload
Underload
Extensive Starts per hour

Communication (optional)

Description of Features
Optimized Performance, Safety, Convenience
and Reliability

DeviceNet
ControlNet
EtherNet/IP
Profibus DP
Remote I/O
RS485-DF1

Programming

The Rockwell Automation MV SMC Flex Smart Motor Controller offers:

Standard Control Module

Soft Start with Selectable Kickstart


Soft Stop
Current Limit Start with Selectable Kickstart
Linear Speed Acceleration* with Selectable Kickstart
Linear Speed Deceleration*
Dual Ramp with Selectable Kickstart
Full Voltage
Preset Slow Speed

Three-level menu structure (using standard languages)


Built-in LCD display and keypad
Multiple languages: English, French, German, Italian, Mandarin,
Portuguese, Spanish
Optional Human Interface Modules (DPI-based)
Configurable with DriveTools programming software

Vacuum Contactor

Optional Control Module

Fixed mounted vacuum contactor is standard


Main contactor for unit isolation (1562E)
Bypass contactor removes SCR Power Stack from circuit, once at full
voltage
Eliminates heat generated by SCRs - improves efficiency
Protects SCRs from voltage and current transients
Contactor can be provided with IntelliVAC solid-state control

Pump Control (eliminates water hammer)


separate start and stop profiles

Complete Package

* requires motor tachometer

Motor Protection
Electronic motor overload protection Class 10, 15, 20 and 30 or OFF

32

Quick shipment of several standard configurations


Bulletin 1560E retrofit controller (does not include isolation
switch, main contactor, power fuses and control transformer)
Bulletin 1562E combination controller
Available with optional equipment
Ready for immediate installation
Complete installation documentation
Built to Rockwell Automation quality standards and ISO9001:2000
Fully load tested with a three-phase MV motor

Visit our Web site: www.ab.com.catalogs

Bulletin 1560E / 1562E

Medium Voltage Controller SMC Flex Smart Motor Control Starter

Specifications
Bulletin

Voltage

2400V

3300V

1560E

4160V

6600V

6900V

2400V

3300V

1562E

4160V

6600V

6900V

Rating

Maximum
Horsepower

200A
400A
600A
200A
400A
600A
200A
400A
600A
200A
400A
600A
200A
400A
600A
200A
400A
600A
200A
400A
600A
200A
400A
600A
200A
400A
600A
200A
400A
600A

800
1500
2750
1000
2250
4000
1250
2750
4500
2250
4500
7500
2500
5000
7500
800
1500
2750
1000
2250
4000
1250
2750
4500
2250
4500
7500
2500
5000
7500

Approximate Dimensions
Inches (mm)
Width
26 (660)
26 (660)
44 (1117)
26 (660)
26 (660)
44 (1117)
26 (660)
26 (660)
44 (1117)
36 (914)
36 (914)
44 (1117)
36 (914)
36 (914)
44 (1117)
36 (914)
36 (914)
80 (2032)
36 (914)
36 (914)
80 (2032)
36 (914)
36 (914)
80 (2032)
36 (914)
36 (914)
80 (2032)
62 (1575)
62 (1575)
100 (2540)

Depth
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)
36 (914)

Height
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)

Approximate
Weight
lb (kg)
800 (363)
800 (363)
1,300 (590)
800 (363)
800 (363)
1,300 (590)
800 (363)
800 (363)
1,300 (590)
1,400 (636)
1,400 (636)
1,300 (590)
1,220 (554)
1,220 (554)
1,300 (590)
1,400 (636)
1,400 (636)
2,325 (1056)
1,400 (636)
1,400 (636)
2,325 (1056)
1,400 (636)
1,400 (636)
2,325 (1056)
1,400 (636)
1,400 (636)
2,700 (1227)
2,325 (1056)
2,325 (1056)
4,000 (1812)

Height is 128.5 inches (3264 mm) with ArcShield enclosure with plenum.
Weight will be different with ArcShield.

Visit our Web site: www.ab.com.catalogs

33

Bulletin 1560E / 1562E

Medium Voltage Controller SMC Flex Smart Motor Control

Power Circuit Schematic 1560E

Power Circuit Schematic 1562E

34

Visit our Web site: www.ab.com.catalogs

Bulletin 1572/1576

Medium Voltage Controller Reduced Voltage Autotransformer Starter


Description of Features

400 Amp

Fixed mounted vacuum contactor


(1S, FORWARD, REVERSE and RUN) settings, with closed
transition operation, Bulletin 1576 Reversing starter
(1S, 2S and RUN) settings, with closed transition operation, Bulletin
1572 Non-reversing starter
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
NEMA medium duty, dry type, three (3) winding autotransformer with
50, 65 and 80% taps. The 65% tap shall be used unless otherwise
specified.

Specifications

Visit our Web site: www.ab.com.catalogs

35

Bulletin 1572/1576

Medium Voltage Controller Reduced Voltage Autotransformer Starter

Power Circuit Schematic 1572

Power Circuit Schematic 1576

36

Visit our Web site: www.ab.com.catalogs

Bulletin 1582

Medium Voltage Controller Reduced Voltage Reactor, Non-reversing Starter


Description of Features
Fixed mounted vacuum contactors (START and RUN) with closed
transition operation
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
NEMA medium duty, dry type, three (3) winding reactor with 50,
65 and 80% taps. The 65% tap shall be used unless otherwise
specified.

Specifications

Power Circuit Schematic 1582

Visit our Web site: www.ab.com.catalogs

37

Bulletin 1591A/B

Medium Voltage Incoming Line Units

1591A

1591B

Description of Features (1591A)

Description of Features (1591B)

Incoming bus arrangement for top or bottom cables


Provision for low voltage panel and door
Lug pad with provision for incoming cable lug terminations

Incoming bus arrangement for top or bottom incoming cables


Provisions for the low voltage panel and door
Lug pad with provision for incoming cable lug terminations
Comes as a 2-high structure

Specifications
Approximate Dimensions
Inches (mm)
Depth

Approximate
Weight
lb (kg)

Type of
Controller

Voltage Rating
(Volts)

Incomer Size
Inches (mm)

1591A/B

2400/3300
4160/4800
6600/6900

18 (457)
36 (915)

18 (457)
36 (915)

36 (915)
36 (915)

91 (2325)
91 (2325)

600 (272)
800 (363)

44 (1118)

44 (1118)

36 (915)

91 (2325)

1200 (545)

Width

Height is 128.5 inches (3264 mm) with ArcShield enclosure with plenum.
Weight will be different with Arcshield.
Only available size for 1591B.
Note: A 44 incomer is only available when a 3000A power bus is used.

Power Circuit Schematic 1591A/1591B

38

Visit our Web site: www.ab.com.catalogs

Height

Bulletin 1592BF/M, 1594F/M

Medium Voltage Feeders Fused and Non-Fused Load-Break Switch


Description of Features

Main load break switch for switching primary power source


Feeder load break switch for switching other loads
Isolation between upper and lower power cells
The operating handle is fully interlocked with the power cell door
Provisions on the operating handle for key interlocking
A polycarbonate viewing window in the power cell door to view the
position of the isolation handle
Protective guard over the line terminals, inside the power cell, to
barrier off medium voltage when the power door is open
Feeders for 2-high structures
Bulletin 1592BF fused load break switch, designed as a feeder for
2-high structures
Bulletin 1592F/M fused load break switch, designed for feeder and
mains
Bulletin 1594F/M non-fused load break switch, designed for feeder
and mains

Specifications 1592BF

Specifications 1592F/M / 1594F/M

Visit our Web site: www.ab.com.catalogs

39

Bulletin 1592BF/F/M, 1594F/M

Medium Voltage Feeders Fused and Non-fused Load-break Switch


Power Circuit Schematic 1592BF/F

Power Circuit Schematic 1592M


IL1

CUSTOMERS
INCOMING LINE

IL2

IL3

Power Circuit Schematic 1594F

Power Circuit Schematic 1594M


IL1

CUSTOMERS
INCOMING LINE

IL2

IL3

40

Visit our Web site: www.ab.com.catalogs

Bulletin 1906B/1912B

Medium Voltage Controller Brush-Type Synchronous Starter


Description of Features
Fixed mounted vacuum contactor for Non-reversing Bulletin 1912B
Fixed mounted vacuum contactors (FORWARD and REVERSE) for
reversing Bulletin 1906B
For constant speed applications
Available with or without static exciter
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
control circuit fusing
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
Synchronous control package:
Field application and protection relay (SyncPro II standard)
Field application control pilot relays
Field excitation switch (2-pole contactor standard, when optional
Exciter is not provided as part of the unit)
Field discharge resistor bank

Specifications 1906B

Specifications 1912B

Visit our Web site: www.ab.com.catalogs

41

Bulletin 1906B/1912B

Medium Voltage Controller Brush-Type Synchronous Starter


Power Control Schematic 1906B

Power Control Schematic 1912B

42

Visit our Web site: www.ab.com.catalogs

Bulletin 1906L/1912L

Medium Voltage Controller Brushless Synchronous Starter


Description of Features
Fixed mounted vacuum contactor for Non-reversing Bulletin 1912L
Fixed mounted vacuum contactors (FORWARD and REVERSE) for
reversing Bulletin 1906L
For constant speed applications
Three-pole, gang-operated, non-load break isolating switch with an
external operating handle, fully interlocked with main contactor and
power cell doors
A polycarbonate viewing window in the power cell door to view the
position of the isolating switch
Three (3) R-rated current-limiting power fuses
Three (3) current transformers
Control power transformer with primary and secondary fuses
Segregated low voltage panel to house standard and optional
hardware for unit control and monitoring
IntelliVAC control module for each vacuum contactor, mounted in
low voltage panel, with advanced features:
Additional low voltage control panel accessories including:
control circuit fusing
NORMAL-OFF-TEST circuit
receptacle for external test power supply
set of control circuit terminal blocks
Provisions for optional factory or customer supplied field exciter
(contact Cambridge to ensure low voltage panel space is available
for customer supplied field exciter.)

Specifications 1906L

Specifications 1912L

Visit our Web site: www.ab.com.catalogs

43

Bulletin 1906L/1912L

Medium Voltage Controller Brushless Synchronous Starter

Power Control Schematic 1912L

Power Control Schematic 1906L

44

Visit our Web site: www.ab.com.catalogs

Synchronous Control Package SyncPro II


Description of Features

Designed for Performance

The SyncPro II consists of a programmable small logic controller


(Allen-Bradley MicroLogix 1500) and protection system for squirrelcage, brush-type synchronous motors.

The SyncPro II consists of:

The SyncPro II system is designed to provide supervisory protection


and field control to a brush-type synchronous motor controller,
proper field application timing, squirrel-cage protection against long
acceleration and stall conditions as well as running pullout protection
by monitoring motor power factor. When combined with a suitable
induction motor protection relay, the SyncPro II provides the necessary
overload protection to the brush type synchronous motor.
The SyncPro II is an integral component in our Bulletin 1912B brush
type synchronous, full voltage non-reversing starter.

PanelView 300E
Power factor transducer
Analog/Digital pulse board
Conditioning resistor
Interposing relays FSR and ESR

Designed for Safety, Convenience and Reliability

Programmable motor parameters and setpoints


Wide range of settings for greater user flexibility
Monitors field contactor coil condition
Stores data from last 10 trips
Digital user interface with a high visibility two-line back-lit display
Displays trip and alarm conditions
Terminal block assembly for simple interwiring
Modular concept
Ideal for retrofit applications
Suitable for low voltage and medium voltage slip ring synchronous
motor applications
Self diagnostics

Protection/Control

Squirrel-cage winding protection


Field winding application control
Incomplete sequence
Field voltage failure
Auto load
Stall protection
Pull-out protection (power factor)
Restart lockout

Display/Metering

Detected fault conditions


Slip frequency and starting time during start-up
Power factor
Enter/view setpoints through the DTAM

Visit our Web site: www.ab.com.catalogs

45

Synchronous Control Package SyncPro II


SyncPro II Component Configuration

SyncPro II

46

Controls &
Indicators

Resistor (RF2)

Analog/Digital
Pulse Converter

Resistor (RF1)

Relays
(FSR, ESR,
etc.)

Phase Angle Transducer


PanelView 300E

Visit our Web site: www.ab.com.catalogs

857/865

MODULAR PROTECTION SYSTEM

The Allen-Bradley 857 motor and feeder protection


relay includes the essential functions needed to
protect motors and feeders in diverse industrial
applications. The programmable Bulletin 857
includes the optional arc protection feature, thermal,
trip circuit supervision and circuit breaker
protection. The device can include numerous
communication protocols, as well as a twelvechannel RTD scanner mounted up to 1000m from
the relay, with a fiber optic connection to the relay.
The Allen-Bradley Bulletin 865 differential protection
relay includes the necessary functions to protect
transformers for distribution networks of utilities,
industry power plants and offshore applications, as
well as motor and generator differential protection.
The devices programmable functions include
thermal and circuit breaker protection, and
numerous communication protocols. An optional arc
flash protection system is available.

RTD Scanner

Basic
Unit

47

Rockwell Automation Services & Support


Global Support. Local Address. Peace of Mind.
Providing the resources you need, when and where you need them, Rockwell Automation
has an integrated, global network of ISO-certified repair centers, exchange hubs, field
service professionals, IACET-recognized training centers, certified technical phone
support centers and online tools.

www.rockwellautomation.com/services

Meet Your Everyday Technical Needs


Online & Phone Support
System-level support
Unlimited, real-time support
Unlimited, online resources
and tools
Live chat and support forums

Training Services
Instructor-led and computer
or web-based courses
Virtual classroom
Training assessments
Workstations and job aids

OnSite Support
Embedded engineering
Preventive maintenance
Migrations and conversions
Start-up and commissioning

Repair Services
Product remanufacturing
Third-party repair
Annual repair agreements

Maximize Your Automation Investment


MRO Asset Management
Warranty tracking
Consolidated asset reports
Quick access to global
spare parts inventory
Owned and managed
spare parts inventory

Network & Security Services


Control system lifecycle services
Manage network convergence
Security technology, policies and
procedures services

Safety Services
Safety assessments
Safety design, integration and
validation services

Energy Services
Energy monitoring and
analysis services
General and comprehensive
energy audits

Visit the Rockwell Automation Support Center, http://rockwellautomation.custhelp.com/


for technical information and assistance, plus:
View technical/application notes
Subscribe for product/service email notifications
Obtain software patches
Submit a Question, Live Chat, Support Forums and more

Visit Get Support Now, www.rockwellautomation.com/support to select your country and find your local support information.

Allen-Bradley, CENTERLINE, IntelliCENTER, SMC Flex, ArcShield, IntelliVAC, IntelliVAC Plus, PowerFlex, DeviceNet and SyncPro are trademarks of Rockwell Automation.
Trademarks not belonging to Rockwell Automation are property of their respective companies.

Medium Voltage Products, 135 Dundas Street, Cambridge, ON, N1R 5X1 Canada, Tel: (1) 519.740.4100, Fax: (1) 519.623.8930, www.ab.com/mvb
Publication 1500-SG001B-EN-P March 2011
Supersedes Publication 1500-SG001A-EN-P September 2006

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Printed in Canada

You might also like