power solutions

VEGA

UPS Series

VM 10-100kVA 3/1
VT 10-200kVA 3/3
VT-HP 100-600kVA 3/3
With transformer isolated inverter
High Efficiency and Reliable Power Protection for:
Datacenter and IT Systems
Industrial Applications
Medical, diagnostic and test devices
Bank and Finance applications
Chemical and Manufacturing process
Emergency care systems for building

Optimal protection with highest efficiency


LEVER VEGA Series UPS is the top line in the power quality
solutions for mission critical applications, including datacenters,
industrial processes, building and medical emergency systems.
From scalability to redundancy, from user-friendliness to
maintainability, from parallel to connectivity, and from investment
protection to lower cost of ownership, whichever value you
need, VEGA provides industry leading efficiency.
In fact has been carefully designed to deliver maximum Return
On Investment (ROI) and MTBF ,with the quickest Mean Time
To Repair (MTTR).
VEGA is an online double conversion UPS (VFI SS 111 IEC EN
62040-3) with isolated inverter.
The VEGA Series range includes three-phase input and singlephase output versions from 10 to 100kVA with 6-Pulse thyristor
rectifier (optional 12-Pulse for 60-80kVA) with and without
optional input filter for harmonics-less distortion; from 10 to
200kVA three-phase input and output with 6-Pulse thyristor
rectifier; from 100 to 600kVA three-phase input and output
versions HP with IGBT Power Factor Correction rectifier.

Flexibility and dedicated solutions

Inverter with transformer: full galvanic isolation

VEGA Series has a flexible control which allows several


operational configuration as On-Line or Normal Mode, Ecomode,
Smart Active, Stand-by, Frequency Converter and Voltage
Stabilizer. A broad range of accessories and options, complex
configurations and system architectures can be achieved to
guarantee maximum power availability and the option to add
new UPS without interruption to existing users. Using the
LEVER UPS Group Synchronizer (UGS) and Parallel Systems
Joiner (PSJ), sophisticated inter group parallel and redundant
systems can be achieved to provide the highest possible levels
of resilience and availability.
VEGA UPS can be adapted to meet the most specific
requirements. Contact LEVER offices to discuss customized or
dedicated solutions for your site.

The output isolation transformer on the inverter, inside the UPS


cabinet, provides galvanic isolation for the critical load improving
versatility in system application:
Galvanic isolation for medical loads and special infrastructure;
Two truly separate network inputs (main and emergency),
coming from two different sources (with different neutrals);
this is particularly well suited to parallel system in order to
ensure selectivity between either sources, thus improving the
reliability of the entire installation;
Installation in networks without neutral.

www.lever.it

Typical VEGA UPS design includes as standard splitted input and bypass line, inverter with transformer for total isolation
Input-Bypass-Output-Maintenance disconnectors, Backefeed protection for your network:

Maximum availability

Intelligent battery care: best battery performances

Distributed or centralized parallel configuration of up to 8


units per redundant (N+1) or power parallel system. Parallel
configurations between model with different power ratings are
also possible.
Hot System Expansion (HSE): allows the addition of a further
UPS into an existing system, without the need to switch off the
working UPS or transfer them to bypass mode. This guarantees
maximum load protection, even during maintenance and system
expansion.
Efficiency Control System (ECS): a system to optimize the
operating efficiency of parallel systems, according
Maximum levels of availability, even in the event of an interruption
to the parallel bus cable: the system is FAULT TOLERANT. It is
not affected by connections cable faults and continues powering
the load without disruption, signaling an alarm condition.

VEGA UPS battery care system consists of several features


to optimize the battery performances and operating life, for
example:
Dual level charging to reduce the charging time.
Deep discharging protection to reduce the ageing.
Temperature compensation.
Automatic and Manual Battery test.
Charge blocking system to reduce electrolyte consumption.
VEGA can operate with Open Vented and VRLA, Gel, Ni-Cd
batteries.

VEGA-HP: Zero Impact Source


The VEGA-HP Series features the added advantages of the
Zero Impact Source formula offered by an IGBT-based rectifier.
Such eliminates problems related with installation in networks
with limited power capacity, where the UPS is supplied by a
generator set or anywhere there compatibility problems with
loads generating current harmonics. VEGA-HP has very low
input Total Harmonic Distortion in current, less than 3% in all
load conditions and input Power Factor 0.99, plus the start-up
delay function to restart the rectifier when mains power is really
restored. Such input features provide saving cost in installation
because smaller circuit protections devices, smaller electrical
infrastructure (as genset and transformer) and less wiring size.

Advanced communications
Advanced multi-platform communications for all operating
systems and network environments : PowerShield monitoring
and shutdown software included, with SNMP agent, for
Windows operating systems 8, 7, 2008, Vista, 2003, XP,
Linux, Mac OS X, Sun Solaris, Linux, Novell and other Unix
operating systems (IBM AIX on RS6000 PowerPC, HP UNIX,
SUN Solaris INTEL, SUN Solaris SPARC, SCO OpenServer 5,
SCO UnixWare, Silicon Graphics IRIX, DEC UNIX, Compaq
Tru64 UNIX, Digital UNIX, BSD UNIX, NCR Unix, FreeBSD
UNIX, Open VMS).
The UPS is provided with a cable for direct connection to a
PC (Plug and Play).
Compatible with TeleNetGuard for remote monitoring.
Double RS232 serial port.
Communications slot for network adapter installation; EPO
contact (Emergency Power Off) for switching off the UPS by
remote emergency button.
Remote display panel with graphic display.

MODEL
VM010 VM015 VM020 VM030 VM040 VM060 VM080 VM100
Nominal Power (kVA)
10 15 20 30 40 60 80 100
Active Power (kVA)
9 13.5 18 27 36 54 72 90
INPUT
Input Voltage to Rectifier
380/400/415 Vac 3-phase, 3-wire
Input Voltage to Bypass
380/400/415 Vac 3-phase + N, 4-wire
Permissible Input Voltage
400V +20% / - 25%
Input Frequency
50 or 60 Hz
Permissible Input Frequency
45 65 Hz
Input THDI with input filter
< 5% at nominal voltage and full load
Input Power Factor
> 0,9 with input filter at nominal voltage
Flex Power Walk-In
0 120 sec (selectable)

DC PARAMETERS
Battery Type
VRLA (Valve Regulated Lead Acid), Wet, Ni-Cd
Nominal battery Bus
384Vdc (Float Voltage: 432V) 396Vdc (FV:446V
End Cell Voltage
Selectable from 1.65 to 1.90 V/cell (for VRLA / Wet cells)
DC Ripple Voltage
< 1% (RMS value)
Temperature compensation
Available

OUTPUT
Inverter Type
IGBT-based Sinewave PWM controlled
Output Voltage
220/230/240 Vac 1-phase + N, 2-wire
Output Voltage Regulation
from 210Vac to 242Vac (phase to N)
Output Frequency
50 or 60 Hz (Frequency Converter Mode selectable)
Static Variation
1%
Dynamic Variation
5%
Output Frequency Regulation
0,05% (on battery mode)
Voltage Distortion THDV
1% (typical), 2% (max)
Crest Factor Load Capability
3:1 (compliant with IEC 62040-3)
Speed of frequency variation
1 Hz/sec (settable from 0,1 to 3)
Overload Conditions
110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute (% of Nominal Load)
Short circuit Current
250% for 1 second in current limitation (% of Nominal Load)
Inverter efficiency (%)
95%
Voltage Displacement
120 1 el (with 100% unbalanced load)

SYSTEM PARAMETERS
UPS Efficiency
up to 98% in ECOmode and Smart Active

PHYSICAL PARAMETERS & STANDARDS
Dimensions WxDxH (mm)
800x800
555x740x1400 800x740x1400
x1900
Weight without batteries (kgs) 200 220 230 270 302 440 500 580
Noise level at 1m
60 dBA
62 dBA
Operating temperature
0 +40C
Relative humidity
< 95% non-condensing
Altitude site
< 1000m without derating
Colour
Light Grey 7035
IP Rating
IP20 (further as request)
Remote signals
Dry contact (as standard)
Remote Controls
EPO and Bypass (as standard)
Communications
Double RS232 port + 2 slots for communications interface
Options for communication
SNMP Adapter, Centralized Monitoring Software, Thermal and Humidity sensors,

J-Bus/ModBus, ProfiBus, Additional programmable contacts
Standards
IEC 62040-3, IEC 62040-2, IEC 62040-1-1,

CE Mark; IEC 62040-1-1, EN 50091-2, EN 60950, EN 60529 and VFI 111
Classification as IEC 62040-3
(Voltage Frequency Independent) VFI-SS-111
Cable entrance
Bottom
Moving the UPS
Transpallet
Storage temperature
-25 +70C

MODEL
VT010 VT015 VT020 VT030 VT040 VT060 VT080
Nominal Power (kVA)
10 15 20 30 40 60 80
Active Power (kVA)
9 13.5 18 27 36 54 72
INPUT
Input Voltage to Rectifier
380/400/415 Vac 3-phase, 3-wire
Input Voltage to Bypass
380/400/415 Vac 3-phase + N, 4-wire
Permissible Input Voltage
400V +20% / - 25%
Input Frequency
50 or 60 Hz
Permissible Input Frequency
45 65 Hz
Input THDI with 5th input filter
< 8% at nominal voltage and full load
Input Power Factor
> 0,9 with input filter at nominal voltage
Flex Power Walk-In
0 - 120 sec (selectable)

DC PARAMETERS
Battery Type
VRLA (Valve Regulated Lead Acid), Wet, Ni-Cd
Nominal battery Bus
384Vdc (Float Voltage: 432V)
End Cell Voltage
Selectable from 1.65 to 1.90 V/cell (for VRLA / Wet cells)
DC Ripple Voltage
< 1% (RMS value)
Temperature compensation
Available

OUTPUT
Inverter Type
IGBT-based Sinewave PWM controlled
Output Voltage
380/400/415 Vac 3-phase + N, 4-wire
Output Voltage Regulation
from 360Vac to 420Vac 3-phase
Output Frequency
50 or 60 Hz (Frequency Converter Mode selectable)
Static Variation
1%
Dynamic Variation
5%
Output Frequency Regulation
0,05% (on battery mode)
Voltage Distortion THDV
1% (typical), 2% (max)
Crest Factor Load Capability
3:1 (compliant with IEC 62040-3)
Speed of frequency variation
1 Hz/sec (settable from 0,1 to 3)
Overload Conditions
110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute (% of Nominal Load)
Short circuit Current
250% for 1 second in current limitation (% of Nominal Load)
Inverter efficiency (%)
95%
Voltage Displacement
120 1 el (with 100% unbalanced load)

SYSTEM PARAMETERS
UPS Efficiency
up to 98% in ECOmode and Smart Active

PHYSICAL PARAMETERS & STANDARDS
Dimensions WxDxH (mm)
555x740x1400
800x740x1400
Weight without batteries (kgs)
228
241
256
315
335
460
540
Noise level at 1m
60 dBA
62 dBA
Operating temperature
0 +40C
Relative humidity
< 95% non-condensing
Altitude site
< 1000m without derating
Colour
Light Grey 7035
IP Rating
IP20 (further as request)
Remote signals
Dry contact (as standard)
Remote Controls
EPO and Bypass (as standard)
Communications
Double RS232 port + 2 slots for communications interface
Options for communication
SNMP Adapter, Centralized Monitoring Software, Thermal and Humidity sensors,

J-Bus/ModBus, ProfiBus, Additional programmable contacts
Standards
IEC 62040-3, IEC 62040-2, IEC 62040-1-1,

CE Mark; IEC 62040-1-1, EN 50091-2, EN 60950, EN 60529 and VFI 111
Classification as IEC 62040-3
(Voltage Frequency Independent) VFI-SS-111
Cable entrance
Bottom
Moving the UPS
Transpallet
Storage temperature
-25 +70C

MODEL
VT100 VT120 VT160 VT200
Nominal Power (kVA)
100
120
160
200
Active Power (kVA)
90
108
144
180
INPUT
Input Voltage to Rectifier
380/400/415 Vac 3-phase, 3-wire
Input Voltage to Bypass
380/400/415 Vac 3-phase + N, 4-wire
Permissible Input Voltage
400V +20% / - 25%
Input Frequency
50 or 60 Hz
Permissible Input Frequency
45 65 Hz
Input THDI with 5th input filter
< 10% at nominal voltage and full load
Input Power Factor
> 0,9 with input filter at nominal voltage
Flex Power Walk-In
0 120 sec (selectable)

DC PARAMETERS
Battery Type
VRLA (Valve Regulated Lead Acid), Wet, Ni-Cd
Nominal battery Bus
396Vdc (Float Voltage: 446V)
End Cell Voltage
Selectable from 1.65 to 1.90 V/cell (for VRLA / Wet cells)
DC Ripple Voltage
< 1% (RMS value)
Temperature compensation
Available

OUTPUT
Inverter Type
IGBT-based Sinewave PWM controlled
Output Voltage
380/400/415 Vac 3-phase + N, 4-wire
Output Voltage Regulation
from -8% to +10%
Output Frequency
50 or 60 Hz (Frequency Converter Mode selectable)
Static Variation
1%
Dynamic Variation
5%
Output Frequency Regulation
0,05% (on battery mode)
Voltage Distortion THDV
1% (typical), 2% (max)
Crest Factor Load Capability
3:1 (compliant with IEC 62040-3)
Speed of frequency variation
1 Hz/sec (settable from 0,1 to 3)
Overload Conditions
110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute (% of Nominal Load)
Short circuit Current
250% for 1 second in current limitation (% of Nominal Load)
Inverter efficiency (%)
95%
Voltage Displacement
120 1 el (with 100% unbalanced load)

SYSTEM PARAMETERS
UPS Efficiency
up to 98% in ECOmode and Smart Active

PHYSICAL PARAMETERS & STANDARDS
Dimensions WxDxH (mm)
800x800x1900
Weight (kgs)
600 610 690 790
Noise level at 1m
65 dBA
68 dBA
Operating temperature
0 +40C
Relative humidity
< 95% non-condensing
Altitude site
< 1000m without derating
Colour
Light Grey 7035
IP Rating
IP20 (further as request)
Remote signals
Dry contact (as standard)
Remote Controls
EPO and Bypass (as standard)
Communications
Double RS232 port + 2 slots for communications interface
Options for communication
SNMP Adapter, Centralized Monitoring Software, Thermal and Humidity sensors,

J-Bus/ModBus, ProfiBus, Additional programmable contacts
Standards
IEC 62040-3, IEC 62040-2, IEC 62040-1-1,

CE Mark; IEC 62040-1-1, EN 50091-2, EN 60950, EN 60529 and VFI 111
Classification as IEC 62040-3
(Voltage Frequency Independent) VFI-SS-111
Cable entrance
Bottom
Moving the UPS
Transpallet
Storage temperature
-25 +70C

MODEL
VT100 HP VT120 HP VT160 HP VT200 HP VT250 HP VT300 HP VT400 HP VT500 HP VT600 HP
Nominal Power (kVA)
100 120 160 200 250 300 400 500 600
Active Power (kVA)
90 108 144 180 225 270 360 450 540
INPUT
Input Voltage to Rectifier
380/400/415 Vac 3-phase + N, 4-wire
Input Voltage to Bypass
380/400/415 Vac 3-phase + N, 4-wire
Permissible Input Voltage
400V +20% / - 25%
Input Frequency
50 or 60 Hz
Permissible Input Frequency
45 65 Hz
Input THDI
< 3%
Input Power Factor
> 0,99
Flex Power Walk-In
0 120 sec (selectable)

DC PARAMETERS
Battery Type
VRLA (Valve Regulated Lead Acid), Wet, Ni-Cd
Nominal battery Bus
480Vdc (Float Voltage: 540V)
End Cell Voltage
Selectable from 1.65 to 1.90 V/cell (for VRLA / Wet cells)
DC Ripple Voltage
< 1% (RMS value)
Temperature compensation
Available

OUTPUT
Inverter Type
IGBT-based Sinewave PWM controlled
Output Voltage
380/400/415 Vac 3-phase + N, 4-wire
Output Voltage Regulation
from -8% to +10%
Output Frequency
50 or 60 Hz (Frequency Converter Mode selectable)
Static Variation
1%
Dynamic Variation
5%
Output Frequency Regulation
0,05% (on battery mode)
Voltage Distortion THDV
1% (typical), 2% (max)
Crest Factor Load Capability
3:1 (compliant with IEC 62040-3)
Speed of frequency variation
1 Hz/sec (settable from 0,1 to 3)
Overload Conditions
110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute (% of Nominal Load)
Short circuit Current
250% for 1 second in current limitation (% of Nominal Load)
Inverter efficiency (%)
95%
Voltage Displacement
120 1 el (with 100% unbalanced load)

SYSTEM PARAMETERS
UPS Efficiency
up to 98% in ECOmode and Smart Active

PHYSICAL PARAMETERS & STANDARDS
Dimensions WxDxH (mm)
800x850x1900
1000x850x1900
1500x1000x1900 2100x1000x1900
Weight (kgs)
656
700
800
910
1000
1400
1700 2100
2400
Noise level at 1m
63-68 dBA
70-72 dBA
Operating temperature
0 +40C
Relative humidity
< 95% non-condensing
Altitude site
< 1000m without derating
Colour
Light Grey 7035
IP Rating
IP20 (further as request)
Remote signals
Dry contact (as standard)
Remote Controls
EPO and Bypass (as standard)
Communications
Double RS232 port + 2 slots for communications interface
Options for communication
SNMP Adapter, Centralized Monitoring Software, Thermal and Humidity sensors,

J-Bus/ModBus, ProfiBus, Additional programmable contacts
Standards
IEC 62040-3, IEC 62040-2, IEC 62040-1-1,

CE Mark; IEC 62040-1-1, EN 50091-2, EN 60950, EN 60529 and VFI 111
Classification as
(Voltage Frequency Independent) VFI-SS-111
IEC 62040-3
Cable entrance
Bottom
Moving the UPS
Transpallet
Storage temperature
-25 +70C
Note: The VEGA HP version is also available for American Standard 480V 60Hz with UL certificate.

Redundant configurations
VEGA Series is designed to include numerous useful optional configuration for redundancy in case of very critical loads.
The top 4 are listed below:

Parallel configuration up to 8 units


with distributed bypass

Parallel configuration up to 8 units


with common bypass

Parallel architecture to ensure redundancy of the power source,


adding an optional parallel kit for each UPS.
+ Flexibility and modularity and no single point of failure.

Parallel architecture to ensure redundancy of the power source,


with autonomous static and maintenance bypass management.
+ Selectivity of downstream faults in bypass mode.

Dynamic dual bus configuration

Dual bus system configuration

Solution to ensure redundancy up to the distribution of the


power supply to the loads and improved STS operation.
+ Downstream fault discrimination.

Solution to ensure redundancy of the power supply even during


maintenance. + High availability and redundancy.

UPS Group Synchronizer (UGS) allows two or more nonparallel UPS devices to remain synchronized even during mains
power failure. The UGS also enables a LEVER UPS to be
synchronized with another source that is independent and with
a different power rating.

Parallel Systems Joiner (PSJ) allows two groups of UPS


in parallel whilst operating, in the event of maintenance (with
no interruption to the output), using a power coupling switch.
Should one of the UPS in one of the parallel groups fail, it is
automatically excluded. The PSJ connects the remaining UPS,
to the other parallel group via an external bypass, in order to
continue to guarantee load redundancy.

Energy Cost Saving with the Smart Active operating mode

Direct and Indirect cost effect

The LEVER UPS work as quality power providers and protections for
critical application, within such environments, energy management
is crucial matter. The running costs must be minimized without
compromising resilience, i.e. the ability to adapt to adverse external
conditions whilst ensuring the complete availability of the services
provided. Equipment must operate at the highest possible levels of
efficiency to reduce the strain on critical power supplies and minimize
the effect on the installation area. LEVER standard UPS models have
always been compliant with the highest levels of efficiency in terms of
energy protection and are classified according to a scale with 6 levels,
corresponding with the efficiency value of the UPS with respect to the
European Code of Conduct; this is known as the Eco Energy Level.
The 6 levels have recently been updated to comply with the stringent
new efficiency levels that the CoC requires for 2013-2014. In addition
to this, the availability of the Smart Mode provides a further method
for increasing efficiency, improving the Eco Energy Levels assessment.
SMART MODE operating is an intelligent system able to switch the
UPS in ECOmode (efficiency 98%) when the input mains is reliable and
stable, transferring the UPS in On-Line mode in case mains parameters
become without the ranges. While the mains returns within the right
range for longer the UPS will be switch on ECOmode again.

The direct cost effect are easily estimated comparing with a


double conversion running at typical efficiency of around 93%
at full load (92% at 50% of load), annual savings on the UPS
can be considerable. For example at 0,15 E/kWh rate, for
100kVA UPS working at 50% load the saving is at least
3.500 E/year in almost stable network condition.
There are several indirect effects in better efficiency performance,
basically are infrastructure investments and own running cost.
For example the UPS is kept in an air
conditioned room. The heat losses from
the UPS must be compensated for
by air cooler, which further increases
electricity consumption. Therefore,
UPS efficiency affects the degree of air
conditioning system in rated capacity
and power consumption. For example
only for running cost the saving for
the above system 100kVA at 50%
load will be at least 1.300 E/year at
0,15 E/kWh.
It mean the SMART MODE allows to
recover the unit cost in few years only
by savings in running cost.

Software and Connectivity


LEVER UPS provides several solutions for monitoring and computer management.
The PowerShield is the UPS monitoring software with Multilanguage support with Mutliserver
shutdown also for cross-platform.
PowerShield STANDARD
Version for Windows, Novell Netware, Linux and - MacOS X.
Can control a single UPS (via RS232 or TCP/IP).
Actions scheduling.
Full events managing (by-pass, alarm, etc.).
Emails support, modem calls to TeleNETGuard.
SNMP agent included.
PowerShield FULL
Version for all operating systems supported.
Support up to 32 UPS (or parallel-redundant system).
The SNMP agent has several parameter sensors (Temperature, Humidity, Digital Inputs etc.)
providing the full solutions for the environment monitoring and control.

J-Bus/ModBus interface built in box and intellislot version

Remote Panel with LCD display

Alarms relays cards

Multi I/O (Input and Output)

Brochure VEGA 16/05/2014 ENG