Datasheet Eaton 93E UPS 80-400 kVA

Eaton 93E UPS


80/100/120/160/200/300/400 kVA

Double conversion UPS

Simply effective power protection


• Double conversion provides the highest level of protection
available by isolating the output power from all input
anomalies.
• With a transformer-free design and sophisticated sensing and
control circuitry the 93E UPS delivers an efficiency
of up to 98,5%.
• Active power factor correction (PFC) provides unbeatable 0,99
input power and <5% ITHD, thus eliminating interference with
other critical equipment in the same network and enhancing
compatibility with generators.
• The UPS is optimized for protecting modern 0,9 p.f. rated
IT equipment without the need to oversize.

True reliability
• Patented Powerware Hot Sync® technology makes possible
to parallel up to 3 UPSs in capacity and up to 4 UPSs in
redundancy. The technology enables load sharing without any
communication line, thus eliminating single point of failure and
increasing power availability.
• ABM testing and charging cycle helps you to prevent battery
93E 80-200 kVA
problems and in addition lessens corrosion prolonging battery
servicelife up to 50%.
Advanced power protection for:
Extensive configurability
• Financial services
• The 93E offers over 20% smaller footprint compared to
• Building management
competitive UPS offerings.
• Telecommunications
• A multilingual graphical LCD display makes possible to monitor
• Industrial automation equipment the UPS status easily.
• Healthcare
• Wide software and connectivity options provide monitoring,
• Government management and shutdown capabilities over the network.
• Data centres • Connectivity options are available to suit nearly any
communication requirements, from standard serial
communications to secure remote monitoring over the Web.

Cost savings and sustainability


• A new technical platform used in Eaton´s three-phase UPS
products guarantee easy upgrades, low MTTR, similarity on
service trainings and documentation, thus lowering total cost
of ownership.
• A range of service agreement options can be easily
customized for customers’ needs and budget.
Eaton 93E UPS 80-400 kVA Technical Spec­i­fi­ca­t ions
General Output
80 100 120 160 200 300 400 kVA Output wiring 3 ph + neutral
UPS output power rating (0.9 p.f.)
72 90 108 144 180 270 360 kW
220/380, 230/400 (default),
Efficiency in double conversion mode Nominal voltage rating (configurable)
94% 240/415 V 50/60 Hz
(full load)
Output UTHD <2% (100% linear load)
Distributed paralleling
3+1 Output power factor 0.9
with Hot Sync technology
Inverter/rectifier topology Transformer-free IGBT with PWM Permitted load power factor 0.7 lagging – 0.9 leading
≤65 dB (80-120kVA), ≤70dB 10 min 102-125% load
Audible noise (160-200kVA) and ≤73dB Overload on inverter 1 min 126-150% load
(300-400kVA) at 1 m, 75% load 150 ms >151% load

Altitude (max) 1000 m without derating (max 2000 m) Continuous <115% load, 20 ms 1000%
Overload when bypass available peak current. Note! External bypass
600 x 800 x 1876 (mm) 80-200 kVA fuses may limit the overload capability.
Dimensions W x D x H 1600 x 820 x 1880 (mm) 300-400 kVA
Accessories
UPS ambient service temperature 0°C to +40°C
External battery cabinets, internal manual bypass switch up to 120 kVA,
Input external maintenance bypass switch, MiniSlot connectivity
Input wiring 3 ph + neutral (Web/SNMP, ModBus/Jbus, Relay)

Nominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz Communications

+20% / -15% at 100% load MiniSlot 2 communication bays


Input voltage range
+20% / -50% at 50% load Serial ports USB, RS232
Input frequency range 42-70 Hz Relay inputs/outputs Three Signal inputs
Input Power Factor 0,99 Compliance with standards
Input ITHD < 5% Safety (CB certified) IEC 62040-1
EMC IEC 62040-2, EMC Category C3
Soft start capability Yes
Performance IEC 62040-3
Internal backfeed protection Yes Due to continuous product improvement programs, specifications are subject to change without notice.
Battery
Battery type VRLA
Charging method ABM technology or Float
432 V (36 x 12 V, 216 cells)
Battery nominal voltage (lead-acid) 456 V (38 x 12 V, 228 cells)
480 V (40 x 12 V, 240 cells)
Charging current / Model 80 100 120 160 200 300 400 kVA
Default 20 20 20 20 20 20 20 A
Max* 40 40 40 80 80 120 160 A
*May be limited by maximum UPS input current rating

93E 300-400 kVA

Eaton is a registered trademark


© 2014 Eaton of Eaton Corporation.
All Rights Reserved
93E01DAT, Rev C All other trademarks are property of their
April 2014 www.eaton.eu/powerquality respective owners.