Press. Regulator
Press. Regulator
Press. Regulator
The industry standard for pressure regulators and flow control products.
Conversion Tables
TEMPERATURE CONVERSION FORMULAS
From Fahrenheit (F) to Celsius (C)
(F - 32) x 5/9
(F + 459.67) / 1.8
(C x 9/5) + 32
(C + 273.15)
(1.8 x K) - 459.67
(K - 273.15)
PRESSURE CONVERSION
FROM
TO
bar
bar
kPa
mm Hg (0C)
mm H2O (4C)
kg/cm2
in H2O (4C)
psi
in Hg (32C)
100
750.064
10197.443
1.02
401.474
14.504
29.53
kPa
0.01
7.501
101.974
0.01
4.015
0.145
0.295
mm Hg (0C)
0.001
0.133
13.595
0.001
0.535
0.019
0.039
mm H2O (4C)
0.0001
0.01
0.074
0.0001
0.039
0.001
0.003
kg/cm2
0.981
98.067
735.561
10000.275
393.712
14.223
28.959
in H2O (4C)
0.002
0.249
1.868
25.4
0.003
0.036
0.074
psi
0.069
6.895
51.715
703.089
0.07
27.681
2.036
in Hg (32C)
0.034
3.386
25.4
345.324
0.035
13.595
0.491
TO
3
Nm /hr
SCFH
SCFM
in3/min
Nliters/min
Nm3/hr
35.31
0.59
1,017
16.67
SCFH
0.03
0.02
28.8
0.47
SCFM
1.7
60
1,728
28.32
in3/min
0.001
0.03
0.0006
0.02
Nliters/min
0.06
2.12
0.04
61.02
TO
liters/sec
liters/min
m3/h
ft3/min
ft3/hr
US
gallon/min
UK
gallon/min
barrels
(petroleum)/min
liters/sec
60
3.6
2.12
127.1
15.85
13.2
0.38
liters/min
0.02
0.06
0.04
2.12
0.26
0.22
0.01
m /h
0.28
16.67
0.59
35.31
4.4
3.67
0.1
ft3/min
0.47
28.32
1.7
60
7.48
6.23
0.18
ft3/hr
0.01
0.47
0.03
0.02
0.12
0.1
0.003
US gal/min
0.06
3.79
0.23
0.13
8.02
0.83
0.02
UK gal/min
0.08
4.55
0.27
0.16
9.63
1.2
0.03
barrels (petroleum)/min
2.65
159
9.54
5.62
336.9
42
34.97
Table of Contents
INTRODUCTION
Introduction to Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Industrial Regulator Quick Selection Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 7
Fisher Industrial Regulator Plant Utility Application Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 - 9
Regulators
Air
Liquids
MR95 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Type MR105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
MR98 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Type MR108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
67C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Type 92W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1301F/1301G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Type 63EG-98HM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
67D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
MR95 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
627 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
MR98 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
63EG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Type LR125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Steam
Type LR128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Type 92B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Type 1098-EGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Type 92S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Type 75A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Type SR5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Process Gas
MR95 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Type 1098-EGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Type 92C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
MR95 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
MR98 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
MR98 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
T205 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
T205 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
T208 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Type T205B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
T205VB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
T208 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Fuel Gas
Type Y692 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Type 310A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Type Y693 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Type EZR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Type ACE95 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Y600A Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Type 1190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Type 1098-EGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Type 1290 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pilot-Operated Regulators
MAIN
REGULATOR
pilot
Regulator
DIAPhRagm
valve
inlet pressure
outlet pressure
ATMOSPHERIC PRESSURE
Direct-Operated Regulators
Direct-Operated regulators are the simplest style of the
regulators. At low set pressures, typically below 1 psig /
0.07 bar, they can have very accurate (1%) control. At
high control pressures, up to 500 psig / 34.5 bar, 10% to
20% control is typical.
In operation, a direct-operated, pressure reducing
regulator senses the downstream pressure through either
internal pressure registration or external control line. This
downstream pressure opposes a spring which moves the
diaphragm and valve plug to change the size of the flow
path through the regulator.
Direct-operated regulators have many commercial and
residential uses. Typical applications include industrial,
commercial, and domestic gas service or instrument air.
4
pilot
main relief
valve
restriction
Control
line
pilot
exhaust
main regulator
Exhaust
flow
inlet pressure
atmospheric pressure
loading pressure
exhaust
Internal Relief
The regulator shown in Figure 5 includes an internal relief
valve. The relief valve has a measuring element (the main
regulator diaphragm), a loading element (a light spring),
and a restricting element (a valve seat and disk).
opened internal relief
valve
vent
flow
system pressure
closed restriction
lower-pressure system
(usually atmosphere)
inlet pressure
outlet pressure
ATMOSPHERIC PRESSURE
OUTLET PRESSURE
RANGE*, psig / bar
Ste
am
Ta
nk
B
Liq lank
eti
uid
ng
Pr
oc
es
sG
Fu
a
el
Ga s
s
Air
TYPE OR OPERATION
SERIES
METHOD
0-125 / 0-8.6
0-150 / 0-10.3
0-150 / 0-10.3
10-500 / 0.69-34.5
67C
67CS
67D
1301
Direct
Direct
Direct
Direct
2-400 / 0.14-27.6
MR95
Direct
2-135 / 0.14-9.3
SR5
Direct
2-250 / 0.14-17.2
92B
Pilot
2-250 / 0.14-17.2
92S
Pilot
5-250 / 0.34-17.2
92C
Pilot
20-80 / 1.4-5.5
75A
Direct
2-250 / 0.14-17.2
92W
Pilot
REFERENCES
MAXIMUM MAXIMUM
INLET
FLOW
PRESSURE, CAPACITY, PAGE BULLETIN NO.
psig / bar SCFH / Nm3/h
250 / 17.2
400 / 27.6
400 / 27.6
6000 / 414
4350 / 117
4350 / 117
20,900 / 560
4500 / 121
17,000 lbs/h /
1/4 to 2
1000 / 68.9
7600 kg/h
6820 lbs/h /
1/2 to 3
210 / 14.5
3096 kg/h
42,400 lbs/h /
1, 1-1/2, 2, 3, and 4
300 / 20.7
19,234 kg/h
45,100 lbs/h /
1 to 6 x 4
300 / 20.7
20,457 kg/h
3600 lbs/h /
1/2, 3/4, and 1
300 / 20.7
1633 kg/h
260 gpm /
1/2 to 2-1/2
200 / 13.8
984 l/min
960 gpm /
1 to 4
300 / 20.7
3720 l/min
3/4, 1, and 2
2000 / 138 162,000 / 4342
82 gpm /
3/4, 1, and 2
900 / 62.1
310 l/min
1650 gpm /
1, 2, 3, and 4
400 / 27.6
6240 l/min
11,934 gpm /
1 to 12 x 6
400 / 27.6
45,170 l/min
1, 2, 3, 4, 6, 8 x 6, and
2,811,000 /
400 / 27.6
12 x 6
75,335
2
1000 / 69.0 265,000 / 7102
2, 3, and 4
10 / 0.69
49,000 / 1313
3/4 and 1
200 / 13.8 12,919 / 346.2
5-500 / 0.34-34.5
627
Direct
10-500 / 0.69-34.5
627W
Direct
MR105
Direct
4"wc-300 / 10 mbar-20.7
1098-EGR
Pilot
1190
Pilot
2"wc-100 / 5 mbar-6.9
2"wc-5 / 5 mbar-0.34
1"wc-7 / 2 mbar-0.48
99
66
T205
Pilot
Direct
Direct
T205B
Direct
3/4 and 1
200 / 13.8
1"wc-10 / 2 mbar-0.69
0.5"wc-10 / 1 mbar-0.69
2"wc-60 / 5 mbar-4.1
Y692
Y693
133
Direct
Direct
Direct
1-1/2 and 2
1-1/2 and 2
2
150 / 10.3
150 / 10.3
150 / 10.3
ACE95
Pilot
3/4, 1, and 1 x 2
200 / 13.8
ACE95jr
Direct
200 / 13.8
ACE95sr
Pilot
200 / 13.8
ACE97
Pilot
200 / 13.8
6"wc-1000 / 15 mbar-69.0
EZR
Pilot
1 to 8
1500 / 103
3.5"wc-60 / 9 mbar-4.1
299H
Pilot
175 / 12.1
10
11
11
71.1:67C
71.1:67C
71.1:67D
71.1:1301
13
71.1: MR95
13
71:1:SR5
12
71.2:92B
12
71.2:92S
13
71.2:92C
17
71.1:75A
16
71.2:92W
11
71.1:627
71.1:627W
16
71.1:MR105
18
71.2:1098-EGR
15
74.1:1190
21
14
71.2:99
74.1:T205
18,568 / 498
14
74.1:T205B
19,820 / 531
26,700 / 716
170,000 / 4556
499,600 /
13,390
3330 / 89.2
499,600 /
13,390
Pad: 499,600 /
13,389
De-pad:
106,200 / 2846
26,138,000 /
700,498
108,120 / 2898
15
15
21
74.1:Y692
74.1:Y693
71.1:133
15
74.1:ACE95
71.1:66
Backpressure Regulator
74.1:ACE95jr
74.1:ACE95
74.3:ACE97
20
71.2:EZR
71.2:299H
Selection Table
OUTLET PRESSURE
RANGE*, psig / bar
Ste
am
Ta
nk
B
Liq lank
eti
uid
ng
Pr
oc
es
sG
Fu
a
el
Ga s
s
Air
Backpressure Regulators
Relief Valve
Backpressure Regulator
TYPE OR OPERATION
SERIES
METHOD
REFERENCES
MAXIMUM MAXIMUM
INLET
FLOW
PRESSURE, CAPACITY, PAGE BULLETIN NO.
psig / bar SCFH / Nm3/h
15-150 / 1-10.3
LR125
Pilot
1, 2, 3, and 4
300 / 20.7
LR128
Pilot
1, 2, 3, and 4
450 / 31.0
4"w.c. to 7 psig /
10 mbar to 0.48 bar
Y600A
Direct
3/4 and 1
150 / 10.3
2"wc-10 / 5 mbar-0.69
CS800
Direct
2052 gpm /
7769 l/min
3368 gpm /
12,748 l/min
17
71.2:LR125
17
71.4:LR128
6660 / 178
20
71.1:Y600A
125 / 8.6
36,270 / 974
71.1:CS800
21
71.2:EZH and
EZHSO
14.5-1160 / 1.0-80.0
EZH
Pilot
1 to 4
1500 / 103
13,833,000 /
370,724
3-500 / 0.21-34.5
630
Direct
1 and 2
1500 / 103
96,000 / 2573
71.1:630
10-700 / 0.69-48.3
310A
Pilot
1 to 4 x 6
1500 / 103
21,170,000 /
567,356
20
71.2:310A
5"wc-75 / 12 mbar-5.2
289
Direct
100 / 6.9
120,000 / 3216
71.4:289
3-125 / 0.21-8.6
1808
Pilot
150 / 10.3
298,000 / 7986
71.4:1808
15-375 / 1.0-25.9
63EG-98HM
Pilot
2 to 6 and 8 x 6
450 / 31.0
4900 gpm /
18,547 l/min
16
71.4:63EG-98HM
2-375 / 0.14-25.9
MR98
Direct
1/4 to 2
400 / 27.6
300 gpm /
1150 l/min
17
71.4: MR98
MR108
Direct
1, 2, 3, and 4
400 / 27.6
1460 gpm /
5530 l/min
16
71.4:MR108
2-125 / 0.14-8.6
SR8
Direct
1/2 to 3
210 / 14.5
5460 lbs/h /
2479 kg/h
71.4:SR8
10-400 / 0.69-27.6
63EG
Pilot
1 to 6 and 8 x 6
400 / 27.6
8,795,000 /
235,706
11
71.4:63EG
2"wc-5 / 5 mbar-0.34
66R
Direct
2, 3, and 4
8 / 0.55
115,000 / 3082
71.4:66
2"wc-7 / 5 mbar-0.48
T208
Direct
3/4 and 1
75 / 5.2
2286 / 61.3
14
74.2:T208
2"wc-7 / 5 mbar-0.48
Y696
Direct
1-1/2 and 2
15 / 1.0
13,100 / 351
74.2:Y696
1290
Pilot
1, 2, 3, 4, 6, 8 x 6, and
12 x 6
12.5 / 0.86
327,400 / 8774
15
74.2:1290
0.5"wc-7 / 1 mbar-0.48
3-60 / 0.21-4.1
119
Direct
150 / 10.3
----
71.1:119
3-150 / 0.21-10.3
167D
Direct
400 / 27.6
----
71.7:167D
14-125 / 0.97-8.6
167DA
Direct
125 / 8.6
----
71.7:167D
2-150 / 0.14-10.3
168
Direct
1/4
150 / 10.3
----
71.7:168
T205VB
Direct
3/4 and 1
200 / 13.8
2468 / 66
19
71.3:T205VB
1"wc-3 / 2 mbar-0.21
Y692VB
Direct
1-1/2 and 2
30 / 2.1
2500 / 67
71.3:Y692VB
0-12.8 / 0-0.88
T208VR
Direct
3/4 and 1
Full Vacuum
1345 / 36.0
71.3:T208VR
1"wc-3 / 2 mbar-0.21
Y696VR
Direct
1-1/2 and 2
Full Vacuum
6953 / 186
71.3:Y696VR
*Inlet/Outlet Pressure Range and Maximum Inlet Pressure are indicated as psig/bar or inches w.c./mbar.
Industrial Regulators
For Plant Utility Applications
Regulator
Industrial
Gas Plant
Control Valve
Control Line
Fuel Gas
Oxygen
Pneumatic Air
Hydrogen
Steam
Nitrogen
Process Liquids
Water
Lube Oil
Water
Tower
MR95
LR128
Pump
MR95
Process
Storage
167DA
MR105
easy-e
67DFR
Compressor
MR98
Feedwater Tank
MR95
Safety Shower/
Eyewash Station
92C
63EG98HM
1098
EGR
66
T205
ACE 95
1290
T208VR
Instrument Purge
Vacuum
Regulator
Glove
Box
Vacuum
Pump
Vapor
Recovery
Vacuum
Breaker
easy-e
Process
Reactor
Process
Reactor
Tank Blanket
T205VB
1098
EGR
Packaging
Station
67DFR
Batch
Reactor
Heat Exchanger
easy-e
92B
92S
Boiler
Air
Compact
Rugged Construction
Integral Filters
Wide Selection
Built to Last
Time-Proven Design
Pressure Reducing
MR95 Series
Body Size
Body Material
Pressure Reducing
67C Series
Body Size NPS 1/4
Outlet Pressure Range 0 to 150 psig / 0 to 10.3 bar
Maximum Inlet
400 psig / 27.6 bar
Pressure
Maximum Capacity 4350 SCFH / 117 Nm3/h
Relief/Backpressure
MR98 Series
NPS 1/4, 1/2, 3/4, 1, 1-1/2, and 2 /
DN 15, 20, 25, 40, and 50
2 to 375 psig /
Relief Pressure Range
0.14 to 25.9 bar
Maximum Inlet
400 psig / 27.6 bar
Pressure
Body Size
10
Pressure Reducing
Pressure Reducing
1301 Series
627 Series
Body Size
Pressure Reducing
Relief/Backpressure
67D Series
63EG Series
NPS 1, 2, 3, 4, 6, and 8 x 6 /
Body Size DN 25, 50, 80, 100, 150, and
200 x 150
Outlet Pressure 10 to 400 psig /
Range 0.69 to 27.6 bar
Maximum Inlet
400 psig / 27.6 bar
Pressure
8,795,000 SCFH /
Maximum Capacity
235,706 Nm3/h
Operation Method Pilot-Operated
Body Material
11
Steam
High Turndown
Rugged Construction
Noise Reduction
Low Maintenance
Accurate
Reliable
Long Service Life
Steam is used throughout industries for
process and space heating. Within the process
industries, steam is used in oil refineries; pulp
and paper mills; chemical production, such
as ethylene and ammonia; food and grain
processing; and textiles.
Refineries and chemical plants use steam tracing
to reduce pumping costs of viscous material
and prevent freezing of process piping. Steam is
used for heat exchangers and reactors to assist
or create process chemical or thermal reactions.
Paper mills utilize major steam generation
systems to generate power and to dry paper
products. Steam is widely used for district
energy systems found in major municipalities
and central plants of universities and hospitals.
Pressure Reducing
Type 92B
NPS 1, 1-1/2, 2, 3, and 4 /
DN 25, 40, 50, 80, and 100
2 to 250 psig /
Outlet Pressure Range
0.14 to 17.2 bar
Maximum Inlet
300 psig / 20.7 bar
Pressure
Maximum Temp
600F / 316C*
Capacity
42,400 lbs/h /
Maximum Capacity
19,234 kg/h
Body Size
Pressure Reducing
Type 92S
NPS 1, 1-1/2, 2, 2-1/2, 3, 4, and
Body Size 6 4 / DN 25, 40, 50, 65, 80,
100, and 150 x 100
Outlet Pressure 2 to 250 psig /
Range 0.14 to 17.2 bar
Maximum Inlet
300 psig / 20.7 bar
Pressure
Maximum Temp
650F / 343C*
Capacity
Maximum
45,100 lbs/h / 20,457 kg/h
Capacity
Operation
Pilot-Operated
Method
Cast Iron, Steel, and
Body Material
Stainless Steel
Bulletin No. 71.2:92S
The Type 92S regulator is piston actuated for high cycle steam service with hardened trim
for improved durability. This valve should be used with clear, dry, or superheated steam.
Noise reduction trim is available.
*
Maximum temperature limitation may vary according to body and construction materials.
Please refer to the product Bulletin or local Sales Office for further information.
12
Pressure Reducing
Pressure Reducing
Type SR5
Type 92C
Pressure Reducing
Relief/Backpressure
MR95 Series
MR98 Series
*
Maximum temperature limitation may vary according to body and construction materials.
Please refer to the product Bulletin or local Sales Office for further information.
13
Tank Blanketing
Tank Blanketing
T205 Series
NPS 3/4 and 1 /
DN 20 and 25
1-inch w.c. to 7 psig /
Control Pressure Range
2 mbar to 0.48 bar
Body Size
12,919 SCFH /
346.2 Nm3/h of Nitrogen
The T205 Series is a compact tank blanketing regulator ideal for blanketing small tanks
and vessels. The unit is easy to install and to maintain.
For larger applications, the Type Y692 is available in NPS 1-1/2 and 2 / DN 40 and 50 sizes.
Tank Blanketing
Type T205B
NPS 3/4 and 1 /
DN 20 and 25
2-inches w.c. to 7 psig /
Control Pressure Range
5 mbar to 0.48 bar
Maximum Inlet
200 psig / 13.8 bar
Pressure
18,568 SCFH /
Flow up to
498 Nm3/h of Nitrogen
Body Size
Vapor Recovery
T208 Series
NPS 3/4 and 1
DN 20 and 25
2-inches w.c. to 7 psig /
Control Pressure Range
5 mbar to 0.48 bar
Body Size
2286 SCFH /
61.3 Nm3/h of Nitrogen
The T208 Series is ideal for small vapor recovery systems. The unit may also be utilized as
a backpressure or relief valve. A larger NPS 1-1/2 and 2 DN 40 and 50 units are available in
the Type Y696.
14
Tank Blanketing
Tank Blanketing
Type Y692
Type 1190
19,820 SCFH /
531 Nm3/h of Nitrogen
NPS 1, 2, 3, 4, 6, 8 x 6, and 12 x 6 /
Body Size DN 25, 50, 80, 100, 150,
200 x 150, and 300 x 150
Control Pressure 0.25-inch w.c. to 7 psig /
Range 0.6 mbar to 0.48 bar
Maximum Inlet
400 psig / 27.6 bar
Pressure
2,811,000 SCFH /
Flow up to
75,335 Nm3/h of Nitrogen
Operation
Pilot-Operated
Method
Cast Iron, Steel, and
Body Material
Stainless Steel
Bulletin No. 74.1:1190
The Type 1190 provides very accurate pressure control on low-pressure blanketing
systems. The regulator helps to control emissions and provides protection against any
contamination from atmospheric conditions.
Tank Blanketing
Vapor Recovery
Type Y693
Type 1290
26,700 SCFH /
716 Nm3/h of Nitrogen
NPS 1, 2, 3, 4, 6, 8 x 6, 12 x 6 /
Body Size DN 25, 50, 80, 100, 150,
200 x 150, and 300 x 150
Control Pressure 0.5-inch w.c. to 7 psig /
Range 1 mbar to 0.48 bar
Maximum Inlet
12.5 psig / 0.86 bar
Pressure
327,400 SCFH /
Flow up to
8774 Nm3/h of Nitrogen
Operation
Pilot-Operated
Method
Cast Iron, Steel, and
Body Material
Stainless Steel
Bulletin No. 74.2:1290
The Type 1290 vapor recovery valve is a very accurate high-capacity which monitors
the tank vapor pressure and opens when the tank pressure increases above the desired
setpoint. The unit is ideal for use with vapor recovery systems because it is not affected by
changes in pressure of the recovery system.
Tank Blanketing
ACE95 Series
NPS 3/4, 1, 1 x 2, and 2 /
DN20, 25, 25 x 50, and 50
Control Pressure -5-inch w.c. to 1.5 psig /
Range -12 mbar to 0.10 bar
Maximum Inlet
200 psig / 13.8 bar
Pressure
Body Size
499,600 SCFH /
13,390 Nm3/h of Nitrogen
15
Liquid
Highest Quality Construction
Best Product Selection
Large Turndown Ratios
Excellent Fluid Capability
Quick and Easy Maintenance
Application Experience
Pressure Reducing
Type MR105
NPS 1, 2, 3, and 4 /
DN 25, 50, 80, and 100
5 to 300 psig /
Outlet Pressure Range
0.34 to 20.7 bar
Body Size
Body Material
Relief/Backpressure
Type MR108
Body Size
NPS 1, 2, 3, and 4 /
DN 25, 50, 80, and 100
Backpressure Control
5 to 300 psig / 0.34 to 20.7 bar
Range
Maximum Inlet Pressure 400 psig / 27.6 bar
Maximum Capacity 1460 gpm / 5530 l/min
Operation Method Direct-Operated
Body Material
Pressure Reducing
Relief/Backpressure
Type 92W
Type 63EG-98HM
Body Size
Outlet Pressure Range
Maximum Inlet
300 psig / 20.7 bar
Pressure
Maximum Capacity 960 gpm / 3720 l/min
Operation Method Pilot-Operated
Body Material Cast Iron and Steel
Bulletin No. 71.2:92W
The Type 92W regulator is piston actuated for high cycle liquid service. The design
utilizes hardened stainless steel trim for durability.
*Maximum temperature limitation may vary according to body and construction materials.
Please refer to the product Bulletin or local Sales Office for further information.
16
Body Size
Pressure Reducing
Relief/Backpressure
MR95 Series
MR98 Series
Pressure Reducing
Relief/Backpressure
Type LR125
Type LR128
NPS 1, 2, 3, 4 /
Body Size
DN 25, 50, 80, and 100
Outlet Pressure Range 15 to 150 psig / 1 to 10.3 bar
Maximum Inlet Pressure 300 psig / 20.7 bar
Maximum Capacity 2052 gpm / 7769 l/min
Operation Method Pilot-Operated
Body Material
Body Size
Pressure Reducing
Type 1098-EGR
Type 75A
Pressure Reducing
NPS 1, 2, 3, 4, 6, 8 x 6, and 12 x 6 /
Body Size DN 25, 50, 80, 100, 150, 200 x
150, and 300 x 150
Outlet Pressure 4 inches w.c. to 300 psig /
Range 10 mbar to 20.7 bar
Maximum Inlet
400 psig / 27.6 bar
Pressure
NPS 1, 2, 3, and 4 /
DN 25, 50, 80, and 100
The Type 1098 regulators are capable of providing accurate, fast response, and
high-capacities in low-pressure drop systems. Typical applications include: inert gas and
plant airheaders.
*Maximum temperature limitation may vary according to body and construction materials.
Please refer to the product Bulletin or local Sales Office for further information.
The 75A regulator is designed to reduce domestic or industrial water pressure, thus
protecting plumbing fixtures and meters from high pressure surges. Type 75A is selfcontained, requiring no external control line for operation. Downstream pressure is
directly registered under the diaphragm. As the downstream pressure increases, the
diaphragm force overcomes the spring compression, causes the valve disk to rise, and
reduces flow through the regulator.
17
Process Gas
Fully Balanced System
High-Capacity
High Sensitivity
Tight Shutoff
Low Setpoints
In-line Maintenance
Broad Material Selection
Pressure Reducing
Type 1098-EGR
NPS 1, 2, 3, 4, 6, 8 x 6, and 12 x 6 /
Body Size DN 25, 50, 80, 100, 150,
200 x 150, 300 x150
Outlet Pressure 4 inches w.c. to 300 psig /
Range 10 mbar to 20.7 bar
Maximum Inlet
400 psig / 27.6 bar
Pressure
11,331,000 SCFH /
Maximum Capacity
303,671 Nm3/h
Operation Method Pilot-Operated
compliance,
manufacturing,
chemical
electronic
production,
Pressure Reducing
MR95 Series
Body Size
The
regulators
and
relief/backpressure
18
Relief/Backpressure
Relief/Backpressure
MR98 Series
T208 Series
Pressure Reducing
Vacuum Breaker
T205 Series
T205VB Series
19
Fuel Gas
High speed response
High-Capacity
Flexibility
Control Accuracy
Easy Maintenance
Safe Operation
Natural gas (methane) is a clean-burning fuel
gas used for many residential, commercial, and
industrial applications. This colorless, naturally
occurring gas can be found in many countries
Pressure Reducing
Type 310A
NPS 1, 2, 3, 4, and 4 x 6 /
Body Size DN 25, 50, 80, 100, and
100 x 150
Outlet Pressure 10 to 700 psig /
Range 0.69 to 48.3 bar
Maximum Inlet
1500 psig / 103 bar
Pressure
21,170,000 SCFH /
Maximum Capacity
567,356 Nm3/h
Operation Method Pilot-Operated
Body Material WCC Steel
Bulletin No. 71.2:310A
The Type 310A pilot-operated high-pressure regulator is used where high-capacity , fast
response, and accurate control are essential. Typical applications include turbine startup
and power plant fuelsupply.
Pressure Reducing
Type EZR
NPS 1, 1-1/4 x 1, 2 x 1, 2, 3,
4, 6, and 8 / DN 25, 32 x 25,
50 x 25, 50, 80, 100, 150,
and 200
Outlet Pressure 6-inches w.c. to 1000 psig /
Range 15 mbar to 69.0 bar
Maximum Inlet
1500 psig / 103 bar
Pressure
26,138,000 SCFH /
Maximum Capacity
700,498 Nm3/h
Body Size
Pressure Reducing
Y600A Series
NPS 3/4 and 1 /
DN 20 and 1
4-inches w.c. to 7 psig /
Outlet Pressure Range
10 mbar to 0.48 bar
Maximum Inlet
150 psig / 10.3 bar
Pressure
6660 SCFH /
Maximum Capacity
178 Nm3/h of Natural Gas
Body Size
20
Pressure Reducing
Pressure Reducing
Type 1098-EGR
Type 99
NPS 1, 2, 3, 4, 6, 8 x 6, and 12 x 6 /
Body Size DN 25, 50, 80, 100, 150, 200 x
150, and 300 x 150
4 inches w.c. to 300 psig /
Outlet Pressure Range
10 mbar to 20.7 bar
Maximum Inlet Pressure 400 psig / 27.6 bar
Maximum Capacity
11,331,000 SCFH /
303,671 Nm3/h
Pressure Reducing
Pressure Reducing
133 Series
NPS 1, 2, 3, and 4 /
Body Size
DN 25, 50, 80, and 100
14.5 to 1160 psig /
Outlet Pressure Range
1 to 80.0 bar
Maximum Inlet Pressure 1500 psig / 103 bar
Maximum Capacity
13,833,000 SCFH /
370,724 Nm3/h
21
Regulator Tips
All regulators should be installed and used in accordance with federal, state, and local codes andregulations.
PRESSURE
SIZING
22
TEMPERATURE
Most regulators shown in this handbook are generally
suitable for temperatures to 180F / 82C. With high
temperature Fluorocarbon (FKM) (if available), the
regulators can be used for temperatures to 300F /
149C. Check the temperature capabilities to determine
materials and temperature ranges available. Use stainless
steel diaphragms and seats for higher temperatures, such
as steam service.
For every 15 psid / 1.0 bar, differential pressure differential
across the regulator, expect approximately one degree
drop in gas temperature due to the natural refrigeration
effect. Freezing is often a problem when the ambient
temperature is between 30F / -1C and 45F / 7C.
Emerson's sales, service and technical support are close at hand. Anywhere in the world, Emerson resources are
available by telephone or on our website. Our distribution network includes an experienced sales and support team,
with more than 2,000 technical experts available from nearly 200 offices throughout the world.
www.fisherregulators.com
23
Industrial Regulators
LP-Gas Equipment
TESCOM
North America
3200 Emerson Way
McKinney, Texas 75070 USA
Tel: +1 800 558 5853
Outside U.S. +1 972 548 3574
North America
3200 Emerson Way
McKinney, Texas 75070 USA
Tel: +1 800 558 5853
Outside U.S. +1 972 548 3574
North America
3200 Emerson Way
McKinney, Texas 75070 USA
Tel: +1 800 558 5853
Outside U.S. +1 972 548 3574
North America
Elk River, Minnesota 55330-2445, USA
Tel: +1 763 241 3238
+1 800 447 1250
Asia-Pacific
Shanghai 201206, China
Tel: +86 21 2892 9000
Asia-Pacific
Singapore 128461, Singapore
Tel: +65 6770 8337
Asia-Pacific
Singapore 128461, Singapore
Tel: +65 6770 8337
Europe
Bologna 40013, Italy
Tel: +39 051 419 0611
Europe
Bologna 40013, Italy
Tel: +39 051 419 0611
Chartres 28008, France
Tel: +33 2 37 33 47 00
Europe
Chartres 28008, France
Tel: +33 2 37 33 47 00
Latin America
Tlalnepantla 54080, Mexico
Tel: +11 52 55 2699 0400
D351342X012 2013 Emerson Process Management Regulator Technologies, Inc. All rights reserved. Printed in China. 11/13.
Fisher, Emerson Process Management, and the Emerson Process Management design are marks of one of the Emerson Process
Management group of companies. All other marks are the property of their respective owners.
Europe
Selmsdorf 23923, Germany
Tel: +49 38823 31 287
Asia-Pacific
Shanghai 201206, China
Tel: +86 21 2892 9000