Design Solar PV System
Design Solar PV System
Design Solar PV System
fractional part of result to the next highest full number and that
will be the number of PV modules required.
Result of the calculation is the minimum number of PV panels. If
more PV modules are installed, the system will perform better and
battery life will be improved. If fewer PV modules are used, the
system may not work at all during cloudy periods and battery life
will be shortened.
3. Inverter sizing
An inverter is used in the system where AC power output is
needed. The input rating of the inverter should never be lower
than the total watt of appliances. The inverter must have the
same nominal voltage as your battery.
For stand-alone systems, the inverter must be large enough to
handle the total amount of Watts you will be using at one time.
The inverter size should be 25-30% bigger than total Watts of
appliances. In case of appliance type is motor or compressor then
inverter size should be minimum 3 times the capacity of those
appliances and must be added to the inverter capacity to handle
surge current during starting.
For grid tie systems or grid connected systems, the input rating
of the inverter should be same as PV array rating to allow for safe
and efficient operation.
4. Battery sizing
The battery type recommended for using in solar PV system is
deep cycle battery. Deep cycle battery is specifically designed for
to be discharged to low energy level and rapid recharged or cycle
charged and discharged day after day for years. The battery
should be large enough to store sufficient energy to operate the
appliances at night and cloudy days. To find out the size of
battery, calculate as follows:
4.1 Calculate total Watt-hours per day used by appliances.
4.2 Divide the total Watt-hours per day used by 0.85 for
battery loss.
4.3 Divide the answer obtained in item 4.2 by 0.6 for depth of
discharge.
4.4 Divide the answer obtained in item 4.3 by the nominal
battery voltage.
4.5 Multiply the answer obtained in item 4.4 with days of
autonomy (the number of days that you need the system to
operate when there is no power produced by PV panels) to get the
required Ampere-hour capacity of deep-cycle battery.
Battery Capacity ( Ah )
3. Inverter sizing
The inverter 300
4. Battery sizing
Nominal battery voltage =12v
Days of autonomy=1
Battery capacity=
(2611)
=43
( 0.850.612)