JIS G3455 Carbon Steel Pipes for High Pressure Service


1. Scope
This Japanese Industrial Standard specifies the carbon steel pipes, hereinafter referred to as the "pipes" , used for high pressure service at an approximate maximum temperature
of 350
Remarks
1. With the previous agreement of the manufacturer, the purchaser may designate part or all of the supplementary quality requirements Z2, Z3 ,Z4 and Z5 specified in this text.
Appendix Z 2: Elevated Temperature Yield Point or Proof Stress
Appendix Z 3: Ultrasonic Examination
Appendix Z 4: Eddy Current Examination
Appendix Z 5: Charpy Impact Test
2. The units and numerical values given un { } in this Standard are based on the International System of Units (SI) and are appended for informative reference.
Further, the traditional units accompanied by numerical values in this Standard shall be converted to the SI units and numerical values on Jan. 1, 1991.
2. Grade and Designation
The pipe shall be classified into three grades and their letter symbols shall be as given in Table 1-1 or Table 1-2.
Table 1
Letter symbol of grade

(Informative reference) Traditional symbol

STS 370

STS 38

STS 410

STS 42

STS 480

STS 49

World standard comparative table


KS
Grade
Number
D 3564

ASTM
GRADE
SPPH 370
SPPH 38
SPPH 410
SPPH 42

Grade
Number
A524

JIS

DIN

GRADE

Grade Number GRADE

Gr ,

G-3455

STS 370(New)
STS 38 (Old)
STS 410(New)
STS 42 (Old)

Grade
Number
1630

BS
GRADE

St 37.4

St 44.4

Grade
Number
-

GRADE

www.TubeSolution.com

Global Marketing for Tube & Pipe

SPPH 480
SPPH 49

STS 480(New)

St 52.4

STS 49 (Old)

3. Method of Manufacture
Appearance shall be as follows:
3.1 The pipe shall be manufactured from killed steel by the seamless process
3.2 The pipe shall be subjected to the heat treatment specified in Table 5-1 of Table 5-2. The heat treatment other than those specified in Table 5-1 of Table 5-2 shall be agreed
upon by the purchaser and the manufacturer.
Table 2
Letter symbol of grade

Hot-finished seamless steel pipe

STS 370

As manufactured. However, low temperature annealing of normalizing

STS 410
STS 480

Cold-finished seamless steel pipe

may be applied, as necessary.

Low temperature annealed of normalized

Low temperature annealed of normalized

3.3 When required by the purchaser, the pipe may be furnished with a bevel end (2)
Note (2)Unless otherwise specified, the shape of the bevel end shall be as shown in Fig. 1.

4. Chemical Composition
The pipe shall be tested in accordance with 9.1 and the resulting ladle analysis values obtained shall conform to Table 2-1 of Table 2-2.
Table 3
Letter symbol of grade

Elongation %
C

Si

Mn

www.TubeSolution.com

Global Marketing for Tube & Pipe

STS 370

0.25 max.

0.10~0.35

0.30~1.10

0.035 max.

0.035 max.

STS 410

0.30 max.

0.10~0.35

0.30~1.40

0.035 max.

0.035 max.

STS 480

0.33 max.

0.10~0.35

0.30~1.50

0.035 max.

0.035 max.

Remark
When product analysis is required by the purchaser, the tolerances on the abovementioned values shall be as given in Table 2 in JIS G 0321
5. Mechanical Properties
5.1 Tensile Strength, Yield Point or Proof Stress and Elongation
The pipe shall be tested in accordance with 9.2 and the tensile strength, yield point of proof stress and elongation of the pipe obtained shall comply with Table 4-1 or Table 4-2.
Table 4
Mechanical Properties
Letter symbol of grade

Tensile strength

Yield point of proof stress

kgf/mm2 {N/mm2}

kgf/mm2 {N/mm2}

Elongation %
No.11 and No.12 test piece

No. 5 test piece

No. 4 test piece

Longi-tudinal

Trans- tudinal

Longi- tudinal

Trans- tudinal

STS 370

38 {373} min.

22{216} min.

30 min.

25 min.

23 min.

28 min.

STS 410

42{412} min.

25{245} min.

25 min.

20 min.

19 min.

24 min.

STS 510

49{481} min.

28{275} min.

25 min.

20 min.

17 min.

22 min.

Remarks
1. When the tensile test is carried out for No. 12 of No. 5 test piece for the pipe under 8mm in wall thickness, the minimum value of elongation shall be obtained by subtracting
1.5% from the values of elongation given in Table 3-2 for each 1 mm decrease in wall thickness, and rounding off to an integer in accordance with JIS Z 8401 Examples of
calculation are given in Informative Reference Table.
2. The value of elongation given in Table 3-2 shall not be applied to the pipe whose nominal outside diameter is under 40 mm. However, the value of elongation shall be recorded.
Informative Reference Table 2.
Examples of Elongation Values Calculated for No. 12 Test Piece (Longitudinal) and No. 5 Test Piece (Transverse) for pipes under 8 mm in Wall Thickness
Elongation value relating to wall thickness %
Letter symbol of grade

STS 370

Shape of test piece

No.12 test piece

Over 7mm up to Over 6mm up to Over 5mm up to Over 4mm up to Over 3mm up to Over 2mm up to Over 1mm up to and
and excl.

and excl.

and excl.

and excl.

and excl.

and excl.

excl.

8mm

7mm

6mm

5mm

4mm

3mm

2mm

30

28

27

26

24

22

21

www.TubeSolution.com

Global Marketing for Tube & Pipe

No.5 test piece

25

24

22

20

19

18

16

STS 410

No.12 test piece

25

24

22

20

19

18

16

STS 480

No.5 test piece

20

18

17

16

14

12

11

5.2 Flatness
When tested in accordance with 9.3, the pipe shall not generate flaws of cracks on its wall surface.
In this case, the distance between the two plates shall be in accordance with the following formula:

Where
H : distance between flattening plates (mm)
t : wall thickness of pipe (mm)
D : outside diameter of pipe (mm)
e : constant individually defined for each grade of pipe, 0.08 for STS 38 0.07 for STS 42 and STS 49
5.3 Bending
For the pipe whose outside diameter is 50mm of smaller, the purchaser may specify the bending test instead of the flattening test. In the test of 9.4, the pipe shall be free form
the occurrence of flaws or cracks on its wall surface. In this case, the pipe shall be bent through 90 around an inside radius that is 6 times its outside diameter.
6. Hydrostatic Characteristic of Nondestructive Characteristic
The pipe shall be tested in accordance with 9.5 and the resulting hydrostatic characteristic of nondestructive characteristic shall conform to either of the following two. The
preference for which of them shall be left to specification by the purchaser or to the discretion of the manufacturer.
6.1 Hydrostatic Characteristic (Applicable to the end of 1990) When a hydrostatic pressure that is specified by the purchaser, of in the absence of that specification, the values
given in Attached Table 1-1 is applied, the pipe shall withstand is without leakage, In this case, the purchaser, may specify a value of pressure lower or higher than those given in
Attached Table 1-1.
In a hydrostatic pressure test designated by the purchaser, a test pressure exceeding either the value of P calculated from the following formula or 200kgf/{196bar} shall be
agreed upon by the purchaser and the manufacturer. In this case, the hydrostatic test pressure shall be expressed in each 5 kgf/ {4.9 bar} and its multiples, and in calculation.
the value P in the following formula shall be obtained to the number of units and rounded off to the nearest 5kgf/{4.9 bar}.
P=200st / D
Where
P: test pressure [ kgf/{10-1 bar(2 )}
t: wall thickness of pipe (mm)
D: outside diameter of pipe(mm)

www.TubeSolution.com

Global Marketing for Tube & Pipe

s: 60% of the minimum value of yield point or proof stress specified in Table 3-1 [kgf/mm2{N/mm2}]
Note (1) 1bar = 105Pa
6.2 Nondestructive Examination Characteristic
A nondestructive examination by either an ultrasonic test or an eddy current test shall be made on the pipe, and there shall be no signal greater than those produced by the
artificial defects of the reference test block of division UD of the working sensitivity specified in JIS G 0582 or of division EY of the working sensitivity specified in JIS G 0583.
7. Appearance
Appearance shall be as follows:
7.1 The pipe shall be practically straight, and its both ends shall be at right angles to its axis.
7.2 The inside and outside surfaces of the pipe shall be well-finished and free from defects that are detrimental to practical use.
8.Dimensions, Weight and Dimensional Tolerances
8.1 Dimensions and Weight
The outside diameter, wall thickness and mass of the pipe shall be as specified in Attached Table 5.
8.2 Dimensional Tolerances
The tolerances on the outside diameter, wall thickness and wall thickness deviation of the pipe shall conform to Table5.
In the case where the pipe length is designated, the value shall be the minimum length.
Table 5. Tolerances on Outside Diameter, Wall Thickness and Wall Thickness Deviation
Division

Tolerances on outside diameter


50mm Under 0.5mm
50mm or over 200mm to and excl.

Tolerances on wall thickness

Tolerances on wall thickness


deviation

4mm Under
+0.6mm

Hot-finished seamless steel 1.6mm

-0.5mm

Within 20%

pipe

4mm or over

of wall thickness

200mm of over 0.8%


For the pipe 350mm of over, the tolerances on outside diameter may be determined by the
measurement of the length of circumference. shall be 0.5%.

Cold-finished seamless steel


pipe

40mm Under0.3mm

+15%
-12.5%
2mm Under
0.2mm

40mm of over 0.8%

2mm or over

Global Marketing for Tube & Pipe

www.TubeSolution.com

For the pipe 350mm or over, the tolerances on outside diameter may be determined by the 10%
measurement of the length of circumference, In this case, the tolerances shall be 0.5%.

Remarks
1. The wall thickness deviation means the ratio of the difference between the maximum and the minimum of the wall thickness measured in the same section the specified wall
thickness, The wall thickness deviation shall not be applied to the pipe under 5.6mm in wall thickness.
2. When the length of circumference is used in measuring the outside diameter, either the measured value of the length of circumference of the diameter derived form the
measured value may be used as the criteria, In both cases, the same value (0.5%) of tolerances shall be applied. The diameter (D) and the length of circumference () shall
be calculated reversibly from the following formula.
= D
where =3.1416
3. In the case where the tolerances on wall thickness are confirmed to meet the specifications in the above table, the tolerances on outside diameter in the above table shall not
be applied to the local part being subjected to repairing, etc.
9. Test
9.1 Chemical analysis
9.1.1 Chemical Analysis
General matters common to chemical analysis and method of sampling specimens for analysis shall be in accordance with 3. in JIS G 0303.
9.1.2 Analytical Method
The analytical method shall be in accordance with one of the following Standards:
JIS G 1253
JIS G 1256
JIS G 1257
JIS G 1214
JIS G 1215
JIS G 1211
JIS G 1212
JIS G 1213
9.2 Tensile Test
9.2.1 Test piece
The test specimen shall be No. 11, No. 12A , No. 12B, No. 12C No. 4 or No.5 test piece specified in JIS Z 2201 and shall be sampled from a pipe. In this case, the gauge length
for No. 4 test piece shall be 50 mm.
9.2.2 Test Method

Global Marketing for Tube & Pipe

www.TubeSolution.com

The test specimen shall in accordance with JIS Z 2241


9.3 Flattening Test
9.3.1 Test piece
A test piece 50 mm or over in length shall be cut off from the end of a pipe. From the pipe whose wall thickness is 15% and over of the outside diameter, a C-shape test piece may
be prepared by removing a part of the circumference of the full-section test piece may be used.
9.3.2 Test Method
The test piece shall be placed between two flat plates at ordinary temperatures and flattened by compression until the distance fence of flaws or cracks on its wall surface. In this
case, the C-shape test piece shall be placed as shown in Fig. 2.

9.4 Bending Test


9.4.1 Test Piece
A test piece with an appropriate length shall be cut off from the end of a pipe.
9.4.2 Test Method
The test piece shall be bent at ordinary temperature through the angle around a cylinder with the inside radius specified in 4,3 and examined for the occurrence of flaws of cracks
on its wall surface.
9.5 Hydrostatic Test of Nondestructive Examination
The hydrostatic test of non destructive examination shall be in accordance shall be in accordance with one of the following:
9.5.1 When the pipe is subjected to hydrostatic pressure and kept under the specified pressure, its strength to withstand the pressure without leakage shall be examined.
9.5.2 The test method of nondestructive examination shall be in accordance with either JIS G 0582 or JIS G 0583.
10. Inspection
Inspection shall be as follows:

Global Marketing for Tube & Pipe

www.TubeSolution.com

10.1 General matters common to inspection shall be in accordance with JIS G 0303.
10.2 The chemical composition, mechanical properties, hydrostatic characteristic of nondestructive characteristic, dimensions and appearance shall conform to the requirements
specified in 3., 4., 5., 6., and 7. However, appropriate nondestructive examination other than those specified in 9.5(2) may substitute as agreed upon by the purchaser and the
manufacturer. Further, when the supplementary quality requirements given in Appendix are specified by agreement between the purchaser and the manufacturer, the results of
inspection shall conform to the requirements specified in Z2, Z3, Z4 ofZ5.
10.3 Either the hydrostatic test of the nondestructive examination shall be performed for each pipe.
10.4 The number of specimens for the product analysis shall be as agreed upon by the purchaser and the manufacturer.
10.5 The method of sampling test specimens and the number of test pieces for tensile test and flattening test of bending test shall be as follows, For the pipe as-manufactured,
take one pipe as the specimen from each 50 pipes of its fraction of the same dimensions(3) , while for the pipe to be heat-treated, take one pipe as the specimen form each 50
pipes or its fraction of the same dimensions(3) and of the concurrent heat treatment, and than take one tensile test piece from the test specimen. Further, for the pipe up under
50mm in outside diameter, take one test piece for the flattening test of the bending test, while for the pipe over 50mm in outside diameter, take one flattening test piece.
Note (3) The term "same dimensions" means the same outside diameter as well as the same wall thickness.
11.Reinspection
The pipe may be determined for final acceptance by a retest requirements of 4.4 JIS G 0303.
12. Marking
Each pipe having passed the inspection shall be marked with the following items. However, the smaller pipes of other pipes specified by the purchaser may be bundled together
and marked for each bundle by a suitable means. In both cases, the order of arranging the marked items is not specified.
When approved by the purchaser, part of the items may be omitted.
(1) Letter symbol of grade
(2) Letter symbol indicating the manufacturing process(4)
(3) Dimensions(5)
(4) Manufactures name or its identifying brand
(5) Letter symbol Z indicating the supplementary quality specification
Notes (4)
The letter symbol indicating the manufacturing process shall be as follows, provided that the dash may be omitted leaving a blank.
Hot-finished seamless steel pipe - S - H
Cold-Finished seamless steel pips - S - C
Note (5)
The dimensions shall be expressed as follows:
Nominal dia. x nominal wall thickness or outside dia. x wall thickness

www.TubeSolution.com

Global Marketing for Tube & Pipe

Example : 50A Sch 80


13. Report
The manufacturer shall, as a rule, submit to the purchaser the report carrying the test results, method of manufacture, ordered dimensions, quantity and work lot number
traceable to the manufacturing conditions, etc.
Attached Table 1-1. Hydrostatic Test Pressure
Unit: kgf/{bar}
Schedule number Sch

40

60

80

100

120

140

160

Hydrostatic Test Pressure

60 {59}

90 {88}

120 {118}

150 {147}

180 {176}

200{196}

200 {196}

Remark:
Attached Table2 For the pipe whose dimension is other than those given in Attached Table 2, the hydrostatic test pressure shall conform to the following table depending on the
division of the ratio (t/D) of the wall thickness to the outside diameter of the pipe.
Over 0.80 up Over 1.60 up to Over 2.40 up to Over 3.20 up to Over 4.00 up to Over 4.80 up to Over 5.60 up to Over 6.30 up to Over 7.10 up to
t/D%

Hydrostatic Test Pressure


kgf/{bar}

to and incl.

and incl.

and incl.

and incl.

and incl.

and incl.

and incl.

and incl.

and incl.

1.60

2.40

3.20

4.00

4.80

5.60

6.30

7.10

7.90

Over 7.90

20 {20}

40 {39}

60 {59}

80 {79}

100 {98}

120 {118}

140

160

180

200

{137}

{157}

{176}

{196}

Attached Table 2. Dimensions and Mass of Carbon Steel Pipes for High Pressure Service
Nominal wall thickness
Nominal Diameter
Outside dia.

Schedule

Schedule

Schedule

Schedule

Schedule

Schedule

Schedule

40

60

80

100

120

140

160

Thickness Unit mass

Thickness

Unit mass

Thickness Unit mass

Thickness

Thickness Unit mass

Thickness

Unit mass

Thickness Unit mass

mm

kg/m

mm

kg/m

mm

kg/m

mm

mm

kg/m

mm

kg/m

mm

kg/m

mm
A

Unit
mass
kg/m

1/8

10.5

1.7

0.369

2.4

0.479

1/4

13.8

2.2

0.629

3.0

0.799

10

3/8

17.3

2.3

0.851

3.2

1.11

15

1/2

21.7

2.8

1.31

3.7

1.64

4.7

1.97

www.TubeSolution.com

Global Marketing for Tube & Pipe

20

3/4

27.2

2.9

1.74

3.9

2.24

5.5

2.94

25

34.0

3.4

2.57

4.5

3.27

6.4

4.36

32

1 1/4

42.7

3.6

3.47

4.9

4.57

6.4

5.73

40

1 1/2

48.6

3.7

4.10

5.1

5.47

7.1

7.27

50

60.5

3.9

5.44

5.5

7.46

8.7

11.1

65

2 1/2

76.3

5.2

9.12

7.0

12.0

9.5

15.6

80

89.1

5.5

11.3

7.6

15.3

11.1

21.4

90

3 1/2

101.6

5.7

13.5

8.1

18.7

12.7

27.8

100

114.3

6.0

16.0

8.6

22.4

11.1

28.2

13.5

33.6

125

139.8

6.6

21.7

9.5

30.5

12.7

39.8

15.9

48.6

150

165.2

7.1

27.7

11.0

41.8

14.3

53.2

18.2

66.0

200

216.3

8.2

42.1

10.3

52.3

12.7

63.8

15.1

74.9

18.2

88.9

20.6

99.4

23.0

110

250

10

267.4

9.3

59.2

12.7

79.8

15.1

93.9

18.2

112

21.4

130

25.4

152

28.6

168

300

12

318.5

10.3

78.3

14.3

107

17.4

129

21.4

157

25.4

184

28.6

204

33.3

234

350

14

355.6

11.1

94.3

15.1

127

19.0

158

23.8

195

27.8

225

31.8

254

35.7

282

400

16

406.4

12.7

123

16.7

160

21.4

203

26.2

246

30.9

286

36.5

333

40.5

365

450

18

457.2

14.3

156

190

205

23.8

254

29.4

310

34.9

363

39.7

408

45.2

459

500

20

508.0

15.1

184

20.6

248

26.2

311

32.5

381

38.1

441

44.4

508

50.0

565

550

22

558.8

15.9

213

22.2

294

28.6

374

34.9

451

41.3

527

47.6

600

54.0

672

600

24

609.6

17.5

256

24.6

355

31.0

442

38.9

547

460

639

52.4

720

59.5

807

650

26

660.4

18.9

299

26.4

413

34.0

525

41.6

635

491

740

56.6

843

64.2

944

Remarks
1. The designation of the pipes shall be based on the nominal diameter and nominal wall thickness (Schedule number: Sch) However, for the nominal diameter, either A or B
suffixed to the figures of nominal diameter for identification.
2. The mass value shall be calculated form the following formula assuming 1 of steel to be 7.85g and rounded off to 3significant figures in accordance with JIS Z 8401. However,
the values exceeding 1000 kg/m shall be rounded off to whole numbers in kg/m.
W=0.02466 t (D - t)
Where

www.TubeSolution.com

Global Marketing for Tube & Pipe

W: Unit mass of pipe (kg/m)


t: wall thickness of pipe (mm)
D: outside diameter of pipe (mm)
3. Dimensions other than those given in the above table, as required, shall be agreed upon by the purchaser and the manufacturer.
Appendix Supplementary Quality Requirements
The supplementary quality requirements shall be applied only when requested by the purchaser, and the designed items among them shall be carried out by the manufacturer.
Z2 Elevated Temperature Yield Point or proof Stress The elevated temperature yield point or proof stress shall be as follows:
Z2.1 The value of elevated temperature yield point or proof stress and the testing temperature of the pipe shall be agreed upon by the purchaser and the manufacturer.
Z2.2 The test piece and the test method shall be in accordance with JIS G 0567 However, when it is practically difficult for a pipe to provide the test piece specified in JIS G 0567,
the shape of the test piece shall be agreed upon by the purchaser and the manufacturer.
Z2.3 The method of sampling test specimens and the number of test piece shall be as follows. Take one test piece for each testing temperature.
Z3 Ultrasonic Examination
Ultrasonic Examination shall be as follows:
Z3.1 The criterion of the working sensitivity for the ultrasonic examination shall comply with the division UB or UC specified in JIS G 0582, and there shall be no signal greater than
those produced by the artificial defects of the reference test block.
Z3.2 The test method of the ultrasonic examination shall be in accordance with JIS G 0582
Z3.3 The ultrasonic examination shall be performed for each pipe and the results shall conform to the requirements specified in (1)
Z4 Eddy current Examination
Z4.1 The criterion of the working sensitivity for the eddy current examination shall comply with the division EV , EW , or EX specified in JIS G 0583, and there shall be no signal
greater than those produced by the artificial defects of the reference test block.
Z4.2 The test method of the eddy current examination shall be in accordance with JIS G 0583.
Z4.3 The eddy current examination shall be performed for each pipe and the results shall conform to the requirements specified in (1).
Z5. Charpy Impact Test
The Charpy impact test shall be as follows:
Z5.1 The absorbed energy of the pipe in the Charpy impact test shall conform to the requirements given in Appendix Table 1 or Table 2. In this case, the test temperature shall be
-10oC, -20oC or -30oC by agreement between the purchaser and the manufacturer.
Absorption Energy in Charpy Impact Test (Applicable to the end of 1990)
Dimensions of test piece mm

10 10

Absorbed energy in Charpy impact test kgfm {J}


Average value of one set (3 piece)

Each value of 2 pieces

Value of each piece

2.1 {20.6} min.

2.1 {20.6} min.

1.4 {13.7} min.

www.TubeSolution.com

Global Marketing for Tube & Pipe

10 7.5

1.8 {17.7} min.

1.8 {17.7} min.

1.2 {11.8} min.

10 5

1.4 {13.7} min.

1.4 {13.7} min.

1.0 {9.8} min.

Z5.2 The test piece shall be No. 4 test piece specified in JIS Z 2202 to be cut from a pipe in the longitudinal direction. However, the width of the test piece may be altered to 7.5
mm of 5 mm according to the dimensions of the pipe.
Z5.3 The test method shall be in accordance with the method of Charpy impact test specified in JIS Z 2242.
Z5.4 The test results of Charpy impact test shall conform to the requirements of (1).
Z5.5 The method of sampling the test specimens and the number of test pieces shall be an follows. Take one pipe as the specimen from each 100 pipes of its fraction of the
concurrent heat treatment, and then from each specimen take one set (3pieces) of test piece.
Z5.6 Reinspection
When the test results fail to satisfy the requirements. a retest may be made to attain final acceptance provide satisfied the specified value and also the following conditions are
met.
(1) Two of the three values are equal to or higher than the specified average value and only one fails to conform to the "value of each piece" given in Appendix Table.
(2) Two of the three values satisfy the "value of each piece" given in Appendix Table but fail to conform to the specified average value.
In these cases, one set (3 piece) of test pieces shall be newly taken from the same lot to be retested, and each of the three individual tested values shall conform to the "average
value of one set" given in Appendix Table.
JIS Number and Corresponding Foreign Standards
JIS

DIN

NF

ISO

Standard

Standard

Standard

Standard

Number
G3455

Grade

Type

STPT370

Number
1630

Grade

Type

St37,4

(STS38)
STS411

1630

St44.4

(STS42)
STS480
(STS49)

1630

St52.4

Grade

Type

A49-211

TU37b

A49-410

TUE220b

A49-210

TU42b

A49-410

TUE220b

Number

Index
Grade

Type

Number

2604/2

TS4

C003

2604/2

TS9

2604/2

TS13

Number