936fce7864aa
FAIL-SAFE
DIMENSIONS
DESCRIPTION
FWW
FWE
13W-80W
Fluorescent
P O LY C A R B O N AT E H I G H
A B U S E WA L L O R C E I L I N G
LUMINAIRE
C L E A R P R I S M AT I C
OR WHITE
A
A
B
B
MOUNTING
A
A
FWW
2' (nominal)
FWE
2' (nominal)
FWW
4' (nominal)
FWE
4' (nominal)
5 1/4"
(133mm)
5 1/4"
(133mm)
5 1/4"
(133mm)
5 1/4"
(133mm)
25"
(635mm)
25"
(635mm)
49"
(1245mm)
49"
(1245mm)
END VIEWS
5 1/4" (133mm)
5 1/4"
Lamps by others
Double wall lens channel
captivates lens to prevent
unauthorized xture
penetration
Copper wound HPF, rapid
start, Class P, CBM/ETL
ballast is standard
U.L. listed, C.S.A. certied,
standard damp label
5"
(133mm)
(127mm)
FWE
FWW
5" (127mm)
O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: FWW-240-120-LE3-GLR
Voltage 3
120=120V
277=277V
347=347V
Product Family
FWW=High Abuse
Wall Luminaire
FWE=High Abuse
Ceiling Mount
Luminaire
Lamp Type
2'
T5 Fluorescent
128=(1) 28W Lamp
228=(2) 28W Lamps
328=(3) 28W Lamps 3
154=(1) 54W T5HO
Lamp
254=(2) 54W T5HO
Lamps
T8 Fluorescent
117=(1) 17W Lamp
217=(2) 17W Lamps
T12 Fluorescent
120=(1) 20W Lamp 2
220=(2) 20W Lamps 2
4'
T5 Fluorescent
128=(1) 28W Lamp
228=(2) 28W Lamps
328=(3) 28W Lamps 3
154=(1) 54W T5HO
Lamp
254=(2) 54W T5HO
Lamps
T8 Fluorescent
132=(1) 32W Lamp
232=(2) 32W Lamps
Ballast 3
LE3=Energy Saving
Ballast
Electronic Ballast 1
EB81=(1) Ballast for
use with T8 Lamp
EB82=(2) Ballasts for
use with T8 Lamp
EB21=(1) Ballast for
use with T12 Lamp
2
Options
EBP=Emergency
Battery Pack
FNL=Fluorescent
Night Light (Lamp
by others)
GCO=Grounded
Convenience
Outlet
GLR=Fuse and Holder
OPL=Opal Diffuser
RIF=Radio
Interference Filter
SPS=Security Push
Button On/Off
Switch
WL=Wet Location
(covered ceiling
only)
Accessories
(Order Separately)
VRSD=Torxhead
Vandal
Resistant
Screwdriver
T12 Fluorescent
140=(1) 40W Lamp
240=(2) 40W Lamps
Biaxial Fluorescent
140BX=(1) 40W Biax
Lamp
240BX=(2) 40W Biax
Lamp
Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice.
1438
COOPER LIGHTING
1 For specific electronic ballast, specify brand and catalog number. 2 Electronic ballast not available with F20T12 lamps. 3 Products also
available in non-US voltages and 50Hz for international markets. Consult your Cooper Lighting Representative for availability and ordering
information.
1438