Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

B0409

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Data Sheet

Spider8,
Spider8-30
Spider8-01
PC-Measurement
Electronics
Special features
- Simultaneous measurement acquisition
- High sampling rate at 16-bit
resolution
- Optional digital filters
- Calibrated complete measuringchain
- Easy to operate and configure
- No PC intervention required
- Up to 64 channels can be
cascaded
- EMC-tested metal housing
- Compensating resistors with
shunt calibration (Spider8-30)

Individual and mixed operation of all device types


Example:
Spider8-01
1
3

Spider8-30
Individual operation
Spider8-30

Spider8

Mixed operation

B0409-40 en

Specifications

0
1

4,8kHz

RS-232C

A/D
"10V

4,8kHz

4 channels of
the basic
device

2
A/D

"10V

CPU

PC Printerport

DC

A/D
SR01

up to 4
expansion
modules

4,8kHz

A/D

To next Spider8 or to
printer

SR55

"10V
+

3 status signals

8 inputs

8 I/Os

Trigger

Diagrammatic view of measurement signal processing in a Spider8

600 Hz

RS-232C

A/D

4 channels of
the basic
device

"10V

U
+

CPU

DC

PC Printerport

A/D
SR01

up to 4
expansion
modules

600Hz

A/D

3 status signals

Trigger

8 I/Os

SR30

8 inputs

"10V

To next Spider8 or
to printer

Diagrammatic view of measurement signal processing in a Spider8-30


HBM

B0409-40 en

Specifications

DC

RS-232C

A/D

4 channels
of the basic
device

CPU

DC

PC Printerport

A/D
SR01

up to 4
expansion
modules

600Hz

To next Spider8
or to printer

A/D
"10V

SR30

3 status signals

Trigger

8 I/Os

8 inputs

Diagrammatic view of measurement signal processing in a Spider8-01/30

DC

RS-232C

A/D

4 channels
of the basic
device

+
U
+

CPU

DC

PC Printerport

A/D
SR01

up to 4
expansion
modules

4,8 kHz

A/D

3 status signals

8 I/Os

Trigger

SR55

8 inputs

"10V

To next Spider8
or to printer

Diagrammatic view of measurement signal processing in a Spider8-01/55


B0409-40 en

HBM

Specifications
Series
Accuracy class

Spider8 / SR55

Spider8-30 / SR30

Spider8-01 / SR01
0.2

0.1

Digital resolution in the case of final value of the


measuring range

Digit

"25000

Measured value buffer

Meas

< 20000

Baud
Meas/s
Meas/s
Meas/s
Meas/s
-

600, 1200, 2400, 4800, 9600, 19200, 38400, 57600


> 6500
> 19000
> 24000
> 76000
-

Sampling rate (21 levels) per channel

1/s

1...9600

Digital filter
Aperiodic
Average value
Butterworth (4th order)
Bessel (4th order)

Hz
Hz
Hz
Hz

0.1
Sampling rate/8 to sampling rate/4
0.1...200
0.1...200

Transfer rate:
serial
parallel1)

USB

Nibble mode
8Bit mode
Byte mode (two-way)
EPP mode
view data sheet USB

Number of amplifiers
Transducers that can be connected

0.1...1200
0.1...1200

0.1...1200
0.1...1200

4/1

4/1

Strain gauge and ind.


full bridge/half bridge

S/G full bridge / half


bridge/ quarter bridge

DC voltage sources
DC power sources
Resistors
Thermocouples

Channel 02) and 12)

Pulse/frequency
2-phase sensor

Transducer current feed

mA

Transducer excitation voltage

Vrms

0.25
2.5

Carrier frequency (sine / symmetric)

Hz

Transducer resistance

Compensating resistors

120, 350, 700

Shunt calibration signal

mV/V

Transducer cable length up to


Dimensions (W x H x D) Housing
Measuring ranges
Strain gauge / Ind. transducer
Voltage
max. differential input voltage
max. permissible common-mode voltage
(differential voltage input-ground)
input resistance

1)

4800

600
110...1100

50

mm

330 x 75 x 270
"3; "12; "125; "500
"10
-

mV/V
V
V
V

"0.1; "1; "10


"15
50

Current
Resistance

mA

"20; "200
400; 4000

Frequency2)
Period length2)
Counter2)

kHz
s
d

0.1; 1; 10; 100; 1000


0.01; 0.1; 1; 10; 100
25,000; 2,500,000

Depends on the power and hardware of the PC.

2) Only for the Spider8 basic device (channels 0 to 3)


3) Transmission format: counter/100

Accessory:
Subcon 5

(2-9278.0346) Socket for SR01 (included in delivery)

DP15P

(2-3312.0182) Sub-D connector for SR30/SR55

USB/Adapt

(see separate data sheet)

Modifications reserved.
All details describe our products in general form only. They
are not to be understood as express warranty and do not
constitute any liability whatsoever.

B0409-40 en

Hottinger Baldwin Messtechnik GmbH


Postfach 10 01 51, D-64201 Darmstadt
Im Tiefen See 45, D-64293 Darmstadt
Tel.: +49/61 51/ 8 03-0; Fax: +49/61 51/ 8039100
E-mail: support@hbm.com www.hbm.com

You might also like