Gefran 2400
Gefran 2400
Gefran 2400
Main characteristics
Double configurable input for
strain gauge / potentiometer /
linear signal / TC / RTD
Two auxiliary analog inputs
Differential measurement
High precision: 0.1 % f.s. 1 digit
High tripping speed
Automatic calibration for 6-wire
strain gauge
Transmitter power supply and
strain gauge probe power supply
Memory: min. peak, max. peak,
max. peak min. peak
3 configurable alarms, failsafe function
2 digital inputs
up to 4 relay/logic outputs
5-digit display
Serial communication interface:
- RS485/RS232 MODBUS RTU
protocol (optional)
- Profibus DP slave (optional)
Isolated analog retransmission output
(optional)
Main applications
Extrusion lines and injection
presses for plastics
Filling machines
Food processing plants
Pressure measurement and trip
points (direct/differential)
Position measurement and trip
points
Variable setpoints in fast
processes and automations in
general, with signal
retransmission
PROFILE
Fast microprocessor display / alarm unit,
96 x 48 (1/8 DIN) format.
Built with SMT technology for an extremely complete operator interface with
IP54 protection level (IP65 with protective
cover).
The front panel has a 6-key soft-touch
keyboard and 5-digit LED display of process variable and parameters.
The instrument is appropriate for acquisition of signals with high variation speed.
It has two main analog inputs for many
applications, including differential measurements.
The inputs are configurable from the keyboard and accept standard linear signals
(and custom linearized signals), as well as
signals from pressure probes, load cells,
potentiometers, TC, RTD.
There are two additional analog inputs for
linear signals and two digital inputs for
functions such as alarm latch reset, peak
latch reset, calibration check, hold, alarm
setpoint selection.
The outputs (up to 4) are relay or logic,
and are configurable.
The instrument manages functions such
as storage of maximum peak, minimum
peak, peak-peak values.
An optional, optically isolated analog output is available for retransmission of input
value or peak values.
Alarms
4 (10) completely configurable setpoints.
Selectable failsafe function.
MD8 expansion to replace outputs 3 and
4, with 8 additional setpoints.
TECHNICAL DATA
OPERATOR INTERFACE
Display
Configurable from -19999 to 99999 xith
settable decimal point
5 digits bicolors (R/V) 13mm
2 digits (V) 7mm
LED signals: n.14 red
Keys: n.6
Digital communication
The instrument offers an optional RS485
2/4 wire / RS232 serial interface with
MODBUS RTU protocol for access to
instrument parameters, or the option ProfiANALOG INPUTS
bus DP (slave).
Accuracy: 0,1% f.s. 1 digit
(0,2% for TC)
Configuration
Min. sampling time:
The programming procedure is facilitated
by the menu structure, with various confi- 2 msec for main inputs
10msec for auxiliary inputs
guration levels for quick and simple data
Resolution:
search.
without filter: 100000 steps@2msec
with digital filter (selectable):
100000 steps@20msec
100000 steps@100msec (50Hz)
Custom linearization:
fixed intervals: 64 sections
variable intervals: 32 sections max.
self-learning
TC - thermocouple:
J 0...1000C / 32...1832F
K 0...1300C / 32...2372F
R 0...1750C / 32...3182F
S 0...1750C / 32...3182F
T -200...400C / -328...752F
custom -1999...9999
RTD: 2-3 wires
PT100 -200...850C / -328...1562F
int./ext. cold junction compensation
INPUT 3 (auxiliary)
Linear DC:
0...10V, 0/4...20mA, Ri = 50
INPUT 4 (auxiliary)
Linear DC:
0...10V, 0/4...20mA, Ri = 50
ALLARMI
Relay: 5A/250Vac cos=1
Logic: 24Vdc source/sink
OUTPUT 1
Relay (NO/NC)* or Logic
(according to model)
OUTPUT 2
Relay (NO/NC)* or Logic
(according to model)
OUTPUT 3**
Relay (NO/NC)* or Logic
(according to model)
OUTPUT 4**
Relay (NO/NC)* or Logic
(according to model)
POWER SUPPLY
100...240Vac/dc 10%,
20...27Vac/dc 10%,
50...60Hz; max 20VA
Protection via internal fuse, not replaceable
by operator
AMBIENT CONDITIONS
Work temperature: 0...50C
Storage temperature: -20...70C
Humidity: 20...85% Ur non-condensing
WEIGHT
450g
DIMENSION
COMMUNICATION (optional)
SERIAL INTERFACE:
RS485 2/4 wires optically isolated
Protocol: MODBUS RTU
Profibus DP slave
Protocoll: Profibus DP VO (slave)
96 X 48 X 167 mm
ACCESSORIES
MD8 - EXPANSION UNIT
replaces outputs 3 and 4 with an additional 8 outputs (relay or logic, according to
model)
FRONT COVERS
standard Gefran (see catalog)
WINSTRUM KIT
TTL/RS232 interface wires + CD
CONFIGURATION
* terminal C in common
** alternate: version only with OUTPUT3
(switching contact) and interface for MD8
expansion unit
VIA PC:
TTL service interface, connectable to PC
via Winstrum kit
CONNECTIONS
Screw connections
The relay can be energized or de-energized in alarm state (selection via keyboard).
DESCRIPTION FACEPLATE
A - Process variable display, digit height 14mm, red
B - Index value for displayed process variable
C - FUNCTION button
D - LOWER button
E - RAISE button
F - special functions
G - CAL-RST button
H - PEAK button
I - Alarm setpoint signals, red LEDs
L - Function indicators
I
B
CONNECTION DIAGRAMS
IN1
Strain-gauge
Verde
Bianco
Blu
power supply
90-260Vac / 10-30Vac/dc
max. 15VA; 50/60Hz
Marrone o Arancio
Nero o Giallo
Rosso
Input in current
Input in voltage
Thermocouple
Resistance Thermometer
CAL 1
IN1 Tc, Rtd, Lin, Diff, Pot
2-wire
connection
3-wire
connection
Potentiometer
4-wire
2-wire
Potentiometer
R 100
IN2
IN1
Strain-gauge
Strain-gauge
Green
Green
White
White
Black or Yellow
Red
power supply
90-260Vac / 10-30Vac/dc
max. 15VA; 50/60Hz
Black or Yellow
Red
Blue
Brown or Orange
Blue
Brown or Orange
Thermocouple
Thermocouple
Resistance Thermometer
Resistance Thermometer
* For Profibus
connections,
please refer to
single input model
2-wire
connection
3-wire
connection
2-wire
connection
3-wire
connection
4-wire
2-wire
Potentiometer
Potentiometer
R 100
Potentiometer
R 100
108
115
96
48
70
44,5
92
170
10
ORDER CODE
POWER SUPPLY
MODEL
2400
20...27VAC/DC
100...240VAC/DC
None
RS485
DIGITAL COMMUNICATION
Strain-gauge / TC / RTD /
Potentiometer / Linear
RETRANSMISION OUTPUT
None
RS232
Profibus DP
(not available in presence of option
W)
OUTPUTS
4R
4 relay
4D
4 logic
2R
2D
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
The instrument conforms to the European Directives 2004/108/CE and 2006/95/CE with reference to the generic standards:
EN 61000-6-2 (immunity in industrial environment) EN 61000-6-3 (emission in residential environment) EN 61010-1 (safety)
DTS_2400_0509_ENG