Elite 440 Cew3
Elite 440 Cew3
Elite 440 Cew3
Applications
Features
Benefits
(RS-485/Ethernet)
Detachable connectors for easy installation
voltage applications
Cost-effective online monitoring
Field-configurable CT/PT primary and secondary values using
push-buttons
Elite 440
Features
Models
441
442
443 444
445
P-N voltage
Average P-N voltage
P-P voltage
Average P-P voltage
Line current (L1, L2, L3 and Average)
Active / Reactive Current
Frequency
Power factor
Average Power factor
Active Power
Total Active Power
Reactive Power
Total Reactive Power
Apparent Power
Total Apparent Power
Active Total Import / Export Energy
Reactive Import (Q1+Q2) / Export (Q3+Q4) Energy
Reactive (Q1,Q2,Q3,Q4) Energy
Apparent Import / Export Energy
Active / Apparent Forwarded Energy
Reactive Lag / Lead Forwarded Energy
Cumulative MD
Phase Angle
Power On / Off Hours
Load On / Off Hours
Feeder Interruptions Count (When Aux is also off)
Min / Max Values
THD Voltage
THD Current
THD Power
RPM with Freq and VUnb and IUnb
Modbus on RS 485
Note:
Ethernet (add on) module is available for all Elite 440 models as single meter module or gateway
Additional modules (Two pulse input & output or four analogue outputs) can be available in Elite 443 to Elite 448
# Optional software config view is available for reading and configuration
446
447
448
Elite 440
Connection Diagram
LT34W
HT33W
HT34W
1
2
3
1
2
3
1
2
3
N
V1 V2 V3 VN
AUX
+/P -/N
S1 S2 S1 S2 S1 S2
I1
I2
RS-485
+
S1 S2 S 1 S2 S1 S 2
I3
I1
I2
V1 V2 V3 VN
I3
AUX
+/P -/N
- SG
Auxiliary P
supply N
AUX
+/P -/N
RS-485
- SG
RS-485
- SG
Auxiliary P
supply N
Auxiliary P
supply N
In case of CT/PT operated
meter, ensure that meter is
connected on secondary side
of instrument transformer.
V1 V2 V3 VN
In case of 33W, VN is
replaced by V2 .
Mechanical Dimensions
Available Option
(2 Pulse input & output) Or
4 analogue outputs
m
65 m
96 m
m
45 m
57
65
mm
96 mm
mm
56 mm
55 mm
96
6 mm
96 mm
m
45
58 m
I/O module
Ethernet module
Ethernet
Elite 440
Technical specifications
Electrical
Connection type
Voltage range :
Measurement voltage range
Tolerance
Aux power supply range
Current range
Main frequency
Accuracy Class
Burden
Approvals
Standards
Mechanical
Dimensions (WXHXD)
96 x 96 x 65 mm (w/o module);
96 x 96 x 110 mm (with module)
Cut out size 92 x 92 mm
0.5 kg (approx)
FRPC
Combicon connector
2
2.5 mm
Weight
Enclosure
Terminals
Max conductor size
Environmental
Ingress protection
Insulation
Impulse withstand
Temperature
Humidity
Feature
Favourite page
CT/VT primary
Communication
Baud rate
Load survey
Modules
2 Digital pulse input and output (single module)
Ethernet
4 analogue outputs
Input supports voltage range of 8-40VDC with pulse duration of 5 ms for input 1 and
40 ms for input 2. Output are normally open type, voltage rating of 230 V AC @ 100 mA or
48 V DC @ 100 mA with pulse width of 80 ms or 240 ms
10/100base-T for Modbus over TCP/IP communication
Analogue output supports current range of 4-20 mA non-isolated with loop impedance
750 , auxiliary supply 20-40V DC @ 100 mA
Cewe Instrument AB
Box 1006 | SE-611 29 Nykping | Sweden | Tel: +46 (0)155 775 00 | E: info@ceweinstrument.se | Fax: +46 (0)155 775 97 | www.ceweinstrument.se
UK Channel Partner
Secure House, Moorside Road, Winchester, Hampshire, SO23 7RX, England | T: +44 (o) 1962 840048 | F: +44 (o) 1962 841046
E: sales@securetogether.co.uk | www.securetogether.com
Brochure Version Number - 2.5
On / Off
Configurable in field through keypad
RS485 Modbus half duplex (Default) and data will be available in floating point format
(IEEE754)
From 1200-38400 bps (Default 9600 bps)
40 days for 6 parameters @ 30 minutes integration period
Options for 15 or 60-minute integration period.