Solid-State Power OFF-delay Timer: H3CR-H
Solid-State Power OFF-delay Timer: H3CR-H
H3CR-H
Ordering Information
TIMERS
Timing function
Power-OFF delay
Contact type
DPDT
Forced resetting
Available
Timing units
S-series
(seconds)
Terminal form
11-pin models
Supply voltages
Part number
H3CR-HRL
Note:
SPDT
Available
M-series
(minutes)
S-series
(seconds)
M-series
(minutes)
S-series
(seconds)
8-pin models
H3CR-H8L
H3CR-H8RL
Specify both the supply voltage and time unit code (S or M) in addition to the model number when ordering.
Example: H3CR-H8L 24 VAC/DC M
Time unit code
Supply voltage
2 3
1. Classification
H: Power OFF-delay timer
2. Configuration
None: 11-pin socket
8: 8-pin socket
3. Input
None: Without reset input
R: With reset input
4. Dimensions
L: Long-body model
M-series
(minutes)
H3CR-H
H3CR-H
Part Number
Panel
a e mounting
ou
g
adapters
d t
Y92F-30
Fits behind panel, ideal for side by side installation. Use P3G-08 socket.
Installs through panel front; timer face fits bezel, rear of timer clips to adapter. Use P3G-08
Y92F-70
socket Fits 65-66 mm (2.56
socket,
(2 56 - 2.59
2 59 in) x 52-53 (2.04
(2 04 x 2.09
2 09 in) panel cutout.
cutout Charcoal gray face
plate measures 88 H x 58 W mm (3.46 x 2.28 in)
Installs through panel front; timer face fits bezel, rear of timer clips to adapter. Use P3G-08
socket, Fits 55 x 45 mm (2.17 x 1.77 in) panel cutout. Charcoal gray face plate measures 58 H
x 50 W mm (2.28 x 1.97 in)
Y92F-71
PFP-50N
PFP-100N
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Protective Cover
Hard plastic cover protects against dust dirt and water: not for use with panel covers.
Y92A-48B
Sockets
Soc
es
Bottom surface or track mounting, top screw terminals. Use with 8-pin terminal form timer.
P2CF-08
Bottom surface or track mounting, top screw terminals. Use with 11- pin terminal form timer.
P2CF-11
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals. Use with
8-pin terminal form timer.
P3G-08
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals. Use with
11-pin terminal form timer.
P3GA-11
Mounting Track
RANGE SELECTION
Output indicator (red)
Time range
Setting
Time range
selector (select one
from 0.6, 1.2, 6, 12)
S-series
M-series
seconds
minutes
0.6
0.05 to 0.6
1.2
0.1 to 1.2
0.5 to 6
12
1 to 12
0.1 sec
min.
2 sec
min.
H3CR-H
H3CR-H
Specifications
H3CR-H8L
Part number
Supply voltage (see
note)
100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz)
AC/DC
AC
AC/DC
Control outputs
H3CR-HRL
AC
Operating voltage
Power consumption
H3CR-H8RL
Type
DPDT relay
Max. load
Min. load
10 mA at 5 VDC
SPDT relay
DPDT relay
Repeat accuracy
0.3% full scale max. (0.3% full scale max.10 ms in ranges of 0.6 and 1.2 s)
Setting error
Resetting system
Instantaneous operation/
Time-limit reset
Resetting time
50 ms min.
Indicators
Materials
Mounting
Connections
Weight
Approvals
Ambient temperature
Shock
Operating
Storage
Humidity
Vibration
35% to 85%
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
0.5% full scale max. (0.5% full scale max. 10 ms in ranges of 0.6 and 1.2 s)
2% full scale max. (2% full scale max. 10 ms in ranges of 0.6 and 1.2 s)
Service life
Mechanical
Electrical
Insulation resistance
Note:
A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC model.
H3CR-H
H3CR-H
Engineering Data
Switching operations (x 10 3 )
10,000
5,000
1,000
Note:
30 VDC L/R = 7 ms
500
250 VAC/30 VDC
(cos = 1)
100
250 VAC (cos = 0.4)
Operation
BLOCK DIAGRAMS
Without Reset Input (H3CR-H8L)
Time range
selector
Power supply
circuit
Oscillation
circuit
Counting
circuit
Power failure
detection circuit
Output
circuit
Indicator
circuit
LCD
AC (DC) input
Output
indicator
Time range
selector
Power supply
circuit
Oscillation
circuit
Counting
circuit
Power failure
detection circuit
Reset input
Output
circuit
Indicator
circuit
Input circuit
LCD
AC (DC) input
Output
indicator
H3CR-H
H3CR-H
Timing Charts
H3CR-H8L
Rt
Power
Rt
ON
OFF
Output (1 -- 3)
Output (1 -- 4)
(--)
(~)
(+)
(~)
Output (8 -- 6)
Power supply
Output (8 -- 5)
Output
indicator
Lit
Not lit
H3CR-H8RL
ON
Power
Rt
Rt
OFF
0.05 s min.
0.05 s min.
ON (Short-circuited)
Reset input
OFF (Open)
Reset
input
(--)
(~)
(+)
(~)
Output (8 -- 6)
Output (8 -- 5)
Power supply
Note:
Output
indicator
Lit
Not lit
H3CR-HRL
Rt
Power
ON
0.05 s min.
0.05 s
min.
Reset input
Output (1 -- 3)
Output (1 -- 4)
(--)(~)
(+)(~)
Output (11 -- 9)
Power supply
Output (11 -- 8)
Note:
OFF
Reset input
Note:
Rt
t
Output
indicator
Lit
Not lit
t: Set time
Rt: Minimum power ON time (S-series: 0.1 s min.; M-series: 2 s min.)
H3CR-H
H3CR-H
Dimensions
Unit: mm (inch)
TIMERS
H3CR-H8L
H3CR-H8RL
15
48 (1.89)
48
(1.89)
78.0 (3.07)
6
63.7
39 dia
(1.54)
44.8 (1.76) x
44.8 (1.75
15
H3CR-HRL
48 (1.89)
48
(1.89)
78.0 (3.07)
6
63.7
39 dia
(1.54)
TRACK MOUNTING
11-Pin models
H3CR-HRL
109.4
2.3*
*These dimensions vary with the kind of DIN track (reference value).
0.7
44.8 (1.76) x
44.8 (1.75
8-Pin models
P2CF-08
P2CF-11
111.7*
0.7
100.7*
H3CR-H8L
H3CR-H8RL
98.4
2.3*
H3CR-H
H3CR-H
PANEL MOUNTING
11-Pin models
8-Pin models
P3G-08
Y92F-30
P3GA-11
Y92F-30
15
15
85.4
91.4
H3CR-H8L
H3CR-H8RL
H3CR-HRL
Panel
0.5 R max.
58
(2.28)
52
(2.05)
+0.6
45 --0
(N)
+0.6
45 --0
Note:
42 (1.65)
48 (1.89)
Recommended panel
thickness should be 1
to 3.2 mm.
Y92F-70
Panel Cutout
Panel
R0.5 max.
45
0.15
52 to 53
88
(3.46)
760.2
65 to 66
450.15
58 (2.28)
Note:
Y92F-71
Panel
56 (2.2)
58
(2.28)
450.2
R0.5 max.
+0.2
50 --0
(1.97)
+0.5
45 --0
+0.5
68
(2.68)
430.2
55 --0
Note:
H3CR-H
H3CR-H
SOCKETS
Track mounting/front connecting socket
P2CF-08
Eight
M3.5 x 7.5 sems
7.8
4.5
Terminal Arrangement/
Internal Connections
(Top View)
70 max.
35.4
(1.39)
400.2
P2CF-11
Eleven
M3.5 x 7.5 sems
4.5
7.8
400.2
35.4
(1.39)
70 max.
Two 4.5 dia.
holes
4
50 max.
31.2 max.
Terminal Arrangement/
Internal Connections
(Bottom View)
27 dia.
45
(1.77)
45
(1.77)
P3GA-11
4.9
17
(0.67)
27 dia.
45
(1.77)
25.6
45
(1.77)
4.5
6.2
16.3
(0.64)
PROTECTIVE COVER
Y92A-48B
50.5
(1.99)
50.5
(1.99)
16 (0.63)
overall depth
H3CR-H
H3CR-H
PFP-100N2
PFP-100N, PFP-50N
16
7.30.15
4.5
4.5
270.15
350.3
15
25
25
10
25
1,000 (500)
(see note)
25
15
15(5)
(see note)
10
350.3
25
25
10
25
27
25 15
10
24
29.2
1.5
PFP-S Spacer
10
6.2
16
12
5
1.8
1
35.5 35.3
50
11.5
34.8
44.3
1.8
1.3
10 M4 x 8
pan head
screw
4.8
16.5
Connections
Part number
COM
Reset
AC (common), DC--
AC (hot), DC+
COM
NC
NO
H3CR-H8L
1
8
4
5
3
6
H3CR-H8RL
H3CR-HRL
10
1
11
4
8
3
9
Installation
INPUT CONNECTIONS
(H3CR-H
OUTPUT CONNECTIONS
(H3CR-H
Design your control circuit using the relay contacts to switch the
load. Never switch a load with the contact that is being used
as an input signal. The timers circuitry may be damaged.
H3CR-H
H3CR-H
A time range (0 to 1.2, 0 to 3, 0 to 12, or 0 to 30) is selected for ONand OFF-time using the time range selector at the lower left corner
of the front panel, and the selected time range appears within the
plastic frame of the time setting knob (= scale range display windows).
TRACK MOUNTING
Using P2CF-
Socket
Mounting
The P2CF-socket has two hooks that
secure the time to the socket. Be sure to
allow at least 20 mm (0.79 in) clearance
above and below the socket to gain access
to release the hooks for servicing and
maintenance. Then clip rear of the socket
to the track. Push the bottom onto the
track until the latch hooks securely.
Hook
Removal
Pull the latch on the socket with a flat--blade
screwdriver and remove the timer and socket as one unit.
20 mm
(0.79 in)
P2CF-11
or P2CF-08
socket
Installation
Mounting tabs
Panel
Retaining clips
for timer
Mounting tabs
Precautions
CAUTIONS
WIRING PRECAUTIONS
H3CR
Except for the wiring of the power supply circuit, avoid laying input
signal wires in parallel or in the same conduit with high tension or
power lines. Use shielded wires or wiring with independent metal
conduits for the shortest possible distance.
Input
terminal
Power supply
Circuit
Rectifier circuit
Never touch the input terminals while power is being applied to the
timer to prevent electric shock.
H3CR-H
H3CR-H
ENVIRONMENT
When usin g th e Time r in an area wit h excess electroni c noi se, separat e th e Time r, wiring , and th e equipmen t whi ch generate s th e input
feren ce..signal s as far as po ss ibl e fro m th e noi se sour ces. It is also
recommende d to shiel d th e inpu t signa l wirin g to pre vent electronic
interferen ce.
Organi c sol vent s (such as pain t thinner) , as wel l as very acidi c or
basic solution s can damag e th e oute r casin g of th e Timer
OTHERS
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
11/97