Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

TM Smartcool 6 200kw

Download as pdf or txt
Download as pdf or txt
You are on page 1of 194

38 0V

22 0V /
0V / 3P
/ 3 3Ph h +
Ph + N
/ 6 N / / 50
0 H 60 H
z Hz z ((-2 ( 0)
) -1)

40

SmartCool Downflow
6 to 200kW
SN, SR and SD
SmartCool Chilled Water

Technical Manual

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Warranty

All Airedale International Air Conditioning products or parts (non consumable) supplied for installation within the UK
mainland and commissioned by an Airedale engineer, carry a full parts & labour warranty for a period of 12 months from the
date of commissioning or 18 months from the date of despatch, whichever is the sooner.
Parts or equipment supplied by Airedale for installation within the UK or for export that are properly commissioned in
accordance with Airedales standards and specification, not commissioned by an AIAC engineer; carry a 12 month warranty
on non consumable parts only from the date of commissioning or 18 months from the date of despatch, whichever is the
sooner.
Parts or equipment installed or commissioned not to acceptable Airedale standards or specification invalidate all warranty.

Warranty is only valid in the event that

In the period between delivery and commissioning the equipment: is properly protected & serviced as per Airedales
installation & maintenance manual provided where applicable the glycol content is maintained to the correct level.
In the event of a problem being reported and once warranty is confirmed as valid under the given installation and operating
conditions, the company will provide the appropriate warranty coverage (as detailed above) attributable to the rectification
of any affected Airedale equipment supplied (excluding costs for any specialist access or lifting equipment that must be
ordered by the customer).
Any spare part supplied by Airedale under warranty shall be warranted for the unexpired period of the warranty or 3 months
from delivery, whichever period is the longer.
To be read in conjunction with the Airedale conditions of sale - Warranty and warranty procedure, available upon request.

CAUTION

Warranty cover is not a substitute for maintenance. Warranty cover is conditional to maintenance being carried out
in accordance with the recommendations provided during the warranty period. Failure to have the maintenance
procedures carried out will invalidate the warranty and any liabilities by Airedale International Air Conditioning Ltd.

Spares

A spares list for 1, 3 and 5 years will be supplied with every unit and is also available from our spares department on
request.

Training

As well as our comprehensive range of products, Airedale offers a modular range of Refrigeration and Air Conditioning
Training courses, for further information please contact Airedale.

Customer Services

For further assistance, please e-mail: enquiries@airedale.com or telephone:



UK Sales Enquiries
+ 44 (0) 113 239 1000
enquiries@airedale.com





International Enquiries
+ 44 (0) 113 239 1000
Spares Hot Line
+ 44 (0) 113 238 7878
Airedale Service
+ 44 (0) 113 239 1000
Technical Support
+ 44 (0) 113 239 1000
Training Enquiries
+ 44 (0) 113 239 1000
For information, visit us at our Web Site: www.airedale.com

enquiries@airedale.com
spares@airedale.com
service@airedale.com
tech.support@airedale.com
marketing@airedale.com

Legal Notices
Airedale International Air Conditioning endeavours to ensure that the information in this document is correct and fairly stated, but none of the statements
are to be relied upon as a statement or representation of fact. AIAC Ltd does not accept liability for any error or omission, or for any reliance placed on
the information contained in this document.
The development of Airedale products and services is continuous and the information in this document may not be up to date. It is important to check the
current position with Airedale at the address stated. This document is not part of a contract or licence unless expressly agreed.
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or
information storage and retrieval systems, for any purpose other than the purchasers personal use, without the express written permission of AIAC Ltd.
Cover image for illustration only.
2014 Airedale International Air Conditioning Limited. All rights reserved. Printed in the UK.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Warranty 2
Health and Safety

Introduction 7

System Configurations
SN, SR Nomenclature

Introduction

Contents

SD Nomenclature

10

Construction 11
SN, SR Units

11

SD Units

11

Unit Overview

12

SN, SR Range

12

SD Range

12

Chilled Water Components

13

Airflow Components

18

Electrical Components

20

Humidification

24

Controls 27
General Features

33

Installation Data

43

Dimensions 43
Positioning 53
Minimum Unit Clearance SN, SR

53

Minimum Unit Clearance SD

54

Incoming Services

62

Glycol 65

Technical Data SN C000 Units


Performance Data SN C000

66
66

SN06D010-C000 68
SN06D015-C000 70
SN09D020-C000 72
SN09D025-C000 74
SN12D030-C000 76
SN12D035-C000 78
Waterside Pressure Drop Data

80

Sound Data

81

Interconnecting Wiring

82

Technical Data SR C000 Units


Performance Data SR C000

84
84

SR09D030-C000 86
SR09D040-C000 88
SR12D045-C000 90
SR12D055-C000 92
SR15D065-C000 94
SR15D075-C000 96
SR18D080-C000 98
SR18D095-C000 100
Waterside Pressure Drop Data

102

Sound Data

103

Interconnecting Wiring

104

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Contents
Technical Data SR C0C0 Units
Performance Data SR C0C0

106
106

SR09D020-C0C0 108
SR09D025-C0C0 110
SR12D030-C0C0 112
SR12D035-C0C0 114
SR15D040-C0C0 116
SR15D045-C0C0 118
SR18D050-C0C0 120
SR18D060-C0C0 122
Waterside Pressure Drop Data

124

Sound Data

125

Interconnecting Wiring

126

Technical Data SD CH00 Units


Performance Data SD CH00

128
128

SD18D110-CH00 130
SD22D140-CH00 132
SD25D175-CH00 134
SD31D215-CH00 136
SD35D255-CH00 138
Waterside Pressure Drop Data

140

Sound Data

142

Interconnecting Wiring

143

Technical Data SD CL00 Units


Performance Data SD CL00

144
144

SD18D115-CL00 146
SD22D145-CL00 148
SD25D180-CL00 150
SD31D235-CL00 152
SD35D270-CL00 154

Waterside Pressure Drop Data

156

Sound Data

158

Interconnecting Wiring

159

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units


Performance Data SD CHCH

160
160

SD18D085-CHCH 162
SD22D105-CHCH 164

Introduction

Contents

SD25D135-CHCH 166
SD31D165-CHCH 168
SD35D195-CHCH 170
Waterside Pressure Drop Data

172

Sound Data

174

Interconnecting Wiring

175

Technical Data SD CLCL Units


Performance Data SD CLCL

176
176

SD18D090-CLCL 178
SD22D120-CLCL 180
SD25D140-CLCL 182
SD31D190-CLCL 184
SD35D225-CLCL 186
Waterside Pressure Drop Data

188

Sound Data

190

Interconnecting Wiring

191

After Sales

192

Warranty 192

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Health and Safety


IMPORTANT

The information contained in this manual is critical to the correct operation of the unit and should be read by all persons
responsible for the installation, commissioning and maintenance of the Airedale unit.

Safety

The equipment has been designed and manufactured to meet international safety standards but, like any mechanical/
electrical equipment, care must be taken if you are to obtain the best results.

CAUTION

Installation, service and maintenance of Airedale equipment should only be carried out by technically trained
competent personnel.

When working with any air conditioning units, ensure that the electrical isolator is switched off prior to servicing or
repair work and that there is no power to any part of the equipment.

Also ensure that there are no other power feeds to the unit such as fire alarm circuits, BMS circuits etc.

Electrical installation commissioning and maintenance work on this equipment should be undertaken by competent
and trained personnel in accordance with local relevant standards and codes of practice.

A full hazard data sheet in accordance with COSHH regulations is available should this be required.

Personal Protective Equipment

Airedale recommends that personal protective equipment is used whilst installing, maintaining and commissioning
equipment.

Manual Handling

Some operations when commissioning, servicing or maintaining the unit may require additional assistance with regard
to manual handling. This requirement is down to the discretion of the engineer. Remember, do not perform a lift that
exceeds your ability.

Environmental Policy

It is our policy to:


Take a proactive approach to resolve environmental issues and ensure compliance with regulatory requirements
Train personnel in sound environmental practices
Pursue opportunities to conserve resources, prevent pollution and eliminate waste
Manufacture products in a responsible manner with minimum impact on the environment
Reduce our use of chemicals and minimise their release to the environment
Measure, control and verify environmental performance through internal and external audits
Continually improve our environmental performance

CE Directive

Airedale certify that the equipment detailed in this manual conforms with the following EC Directives:
Electromagnetic Compatibility Directive (EMC)
Low Voltage Directive (LVD)
Machinery Directive (MD)
Pressure Equipment Directive (PED)

2004/108/EC
2006/95/EC
89/392/EEC in the version 2006/427/EC
97/23/EC

To comply with these directives appropriate national & harmonised standards have been applied.
These are listed on the Declaration of Conformity, supplied with each product.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Designed to provide environmental precision air conditioning for applications such as telecommunication facilities, data
centers, computer rooms, clean rooms and laboratories.
Full function units provide full control of temperature, humidity and filtration.
The modular design of the SmartCool allows grouping of differing model types and capacities to be installed side by
side. The flexibility of this type of installation provides for multi-circuit functionality.

SN, SR

SD

Range
SN C000(1)
SR C000(1)
SR C0C0(1)

Range
SD CH00(1)
SD CHCH(1)
SD CL00(2)
SD CLCL(2)

Performance (kW)
105 255
75 184
92 215
75 185

rat
ion
(J/
g

Dr
yA
ir)

Based on nominal unit capacities 24C 45% RH 7C /12C Water


based on nominal unit capacities 35C 24% RH 18C / 24C Water

Airedale Extended Operating Envelope

En
tha
lpy
a

ASHRAE Recommended Operating Envelope

ts

atu

ASHRAE Allowable Operating Envelope


1

1 + 2 Airedale Operating Envelope

iv
e
el
%

60

at

70

Te
m

20

Moisture Content kg/kg Dry Air

80

pe
ra

tu
re

10
0
90

(
C)

25

ul
b

50

(2)

Performance (kW)
13 36
35 98
25 70

W
et
B

(1)

Introduction

Introduction

40

15

1
10

Moisture Content
Operating Band

2 0%

0
10%

10

15

20

18

25

30

35

40

27
Dry Bulb Temperature (C)

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Introduction

SmartCool 6 - 200kW
System Configurations
SN, SR Range

SD Range

The SN and SR range is designed for the following


nominal conditions:

The SD range is designed for the following nominal


conditions:

SN C000 Units

SD CL00 / CLCL Units

SR C000 / C0C0 Units

SD CH00 / CHCH Units

Precision Air Conditioning

Fans located within unit


Separate floorstand (min 350mm)
Return air of 24C 45% RH
Water temperatures of 7C / 12C

Fans located within unit


Separate floorstand (min 350mm)
Return air of 24C 45% RH
Water temperatures of 7C / 12C

Fans located within floorstand


Floorstand integril to unit (min 600mm)
Return air of 35C 24% RH
Water temnperatures of 18C / 24C

Fans located within floorstand


Floorstand integril to unit (min 600mm)
Return air of 24C 45% RH
Water temperatures 7C / 12C

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

S
S
R
N

Product Name

Variant

684 mm

1521 mm

18

1800 mm

010
095

C000

1242 mm

15

Flow Configuration

055

Narrow Case (600mm deep)

963 mm

Regular Case (890mm deep)

06
Case Width

12

SmartCool

09
12

Introduction

SN, SR Nomenclature

Downflow

Nominal Cooling Capacity (kW)

C000
C0C0

Separator

Cooling Configuration

Single Circuit CW
Dual Circuit CW

Separator

0
1

400V / 3Ph +N / 50Hz


Power Supply

380V / 3Ph +N / 60Hz


220V / 3Ph / 60Hz

SN, SR C000

Where a chilled water single circuit system is


preferred, warm room air is drawn across the
efficient cooling coil of the SmartCool C000 and the
heat transferred to a chilled water system such as
Airedales high efficiency chiller.
By controlling the 2 or 3-way water regulating
valve, the intelligent Airetronix microprocessor
can achieve precise control of temperature and
humidity.

SR C0C0

Where a chilled water dual circuit system is preferred, warm


room air is drawn across the efficient cooling coil of the
SmartCool C0C0 and the heat transferred to a chilled water
system such as Airedales high efficiency chillers.
By controlling the 2 or 3-way water regulating valve, the
intelligent Airetronix microprocessor can achieve precise
control of temperature and humidity.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

SD Nomenclature

S
S

Product Name

SmartCool

Product Variant

Dedicated Chilled Water

18

3100 mm
3500 mm
Flow Conguration

Separator

Chilled Water

L
C
0
H
L
-

Coil Type

Second Circuit

Coil Type Second Circuit

Downow

Coil Streamed For High Flow


Coil Streamed For Low Flow
Chilled Water Circuit
No Chilled Water Circuit
Coil Streamed For High Flow
Coil Streamed For Low Flow

Separator

0
1
2

Nominal Cooling Capacity (kW)

215

2500 mm

35

085-255

2200 mm
Case Width

31

31

1800 mm

22
25

400V / 3Ph + N / 50Hz


Power Supply

380V / 3Ph +N / 60Hz


220V / 3Ph / 60Hz

SD CH00 / SD CL00

Where a chilled water single circuit system is preferred,


warm room air is drawn across the efficient cooling coil of
the SmartCool CH00 or CL00 and the heat transferred to
a chilled water system such as Airedales high efficiency
chiller.
By controlling the single 2 way water regulating valve,
(or additional 2 way bypass) the intelligent Airetronix
microprocessor can achieve precise control of temperature
and humidity.
The CH00 is designed for high water flowrates; whilst the
CL00 is optimised for low flow conditions.

SD CHCH / SD CLCL

Where a chilled water dual circuit system is preferred,


warm room air is drawn across the efficient cooling coil of
the SmartCool CHCH or CLCL and the heat transferred to
a chilled water system such as Airedales high efficiency
chillers.
By controlling the single 2 way water regulating valve,
(or additional 2 way bypass) the intelligent Airetronix
microprocessor can achieve precise control of temperature
and humidity.
The CH00 is designed for high water flowrates; whilst the
CL00 is optimised for low flow conditions.

10

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

The computer room air conditioning equipment shall be designed specifically for precision temperature and humidity
control applications. It shall automatically monitor and control cooling, heating, humidification, de-humidification
and filtering functions for the conditioned space. The system shall be built to the highest quality engineering and
manufacturing standards and shall be subject to a functional test prior to leaving the factory.

Introduction

Precision Air Conditioning System

Construction
SN, SR Units

The cabinet shall be manufactured using an external aluminium extrusion frame with aluminium corners.
Panels shall be completely removable to gain unequalled access during installation as required. The galvanised sheet
steel panels and aluminium frame and corners shall be coated with an epoxy baked powder paint to provide a durable
finish.
Standard unit colour shall be Black Grey to RAL 7021.
Cabinets shall be lined internally with various thickness fire resistant foam (BS 476) for thermal and acoustic insulation.
The insulation density shall not be less than 75 kg/m.
The cabinet doors shall be full height, hinged and key lock secured. The hinge arrangement shall allow flexible door
opening/removal for improved access.
A propriety rubberised door seal shall reduce sound breakout and eradicate air leakage. In-seal type foam based door
seals shall not be acceptable.
The control panel is mounted on hinges to allow easy removal of filters and access to several electrical components.
The unit design shall incorporate a series of M6 fixings to the top and bottom face to ease customer ductwork
connection and reduce installation time.

SD Units

The cabinet shall be manufactured using steel frame.


Panels shall be completely removable to gain unequalled access during installation as required. The galvanised sheet
steel panels shall be coated with an epoxy baked powder paint to provide a durable finish.
Standard unit colour shall be Black Grey to RAL 7021.
Cabinets shall be lined internally with various thickness fire resistant foam (BS 476) for thermal and acoustic insulation.
The insulation density shall not be less than 75 kg/m.
The cabinet doors shall be full height, hinged and key lock secured. The hinge arrangement shall allow flexible door
opening/removal for improved access.
A propriety rubberised door seal shall reduce sound breakout and eradicate air leakage. In-seal type foam based door
seals shall not be acceptable.
The unit design shall incorporate a series of M6 fixings to the top and bottom face to ease customer ductwork
connection and reduce installation time.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

11

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Unit Overview
SN, SR Range

Cooling Coils

Air Filters

Control Panel

Electric Heat

Chilled Water Valves

Fans

Humidification

SD Range

Air Filter
Humidifier

Chilled
water
pipework

Control Panel

Floor
Height
Floorstand

12

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Fans

Precision Air Conditioning

SmartCool 6 - 200kW

SN, SR Range

Introduction

Chilled Water Components

Cooling Coils

Chilled Water Valves

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

13

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Chilled Water Components


SD Range

Cooling Coil
Valves

Pipework
Connections

System Configuration
Range

Chilled Water

Number of Circuits

SR

SD

Single

Single

Dual

Single

Dual

Hydrophilic Epoxy Coated RTPF Chilled Water Coil

0-10 Volts Chilled Water Regulating Valve (2 Way)

0-10 Volts Chilled Water Regulating Valve (3 Way)

0-10 Volts Chilled Water Regulating Valve (2 x 2-Way) Auto Commission

Brazed Connection

Threaded Connections

Grooved Connections

Standard Features

14

SN

Optional Features

Feature Not Available

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Chilled water coils shall be ideally positioned to optimise airflow and heat transfer, they shall be manufactured from plain
copper tubes with mechanically bonded aluminium fins. Fins shall be coated with a non-stick acrylic film (hydrophilic) to
provide additional corrosion protection and efficient surface water removal for improved performance. Plain aluminium
shall not be acceptable.

Introduction

Chilled Water Coil

The cooling coil shall be mounted over a full width stainless steel condensate tray.
For control of water flow, various valve options shall be fitted.
The factory test pressure shall not be less than 20 Barg and the maximum operating pressure shall be less than 10.
Sweat copper pipe for brazed connection shall be standard. Optional threaded and Grooved connections shall be
available.

SN, SR Coils

SD Coil
SN06

Sweat Copper Connection


Threaded Pipe Connection
Grooved Water Connection

Standard Features

SN09

SN12

Optional Features

SR09

SR12

SR15

SR18

SD18

SD22

SD25

SD31

SD35

Feature Not Available

Threaded Water Pipe Connection

As an alternative to brazed water pipe connections, BSP


brass male taper threaded connections shall be factory fitted.

Grooved Water Connections

Grooved water connections shall be avaliable enabling easy


pipework termination.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

15

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Chilled Water Valves


Chilled Water Valve Options

SN06
2 Port Chilled Water Valves
2 Port Chilled Water Valves with
2 Port Commissioning Valve
3 Port Chilled Water Valves
3 Port Chilled Water Valves with Bypass

Standard Features

SN09

SN12

Optional Features

SR09

SR12

SR15

SR18

SD18

SD22

Feature Not Available

0-10 Volts DC 3 Port Chilled Water Regulating Valve (SN, SR Units)

0-10 Volts DC 3 Port Chilled Water Regulating Valve with Bypass (SN, SR Units)

16

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

SD25

SD31

SD35

Precision Air Conditioning

SmartCool 6 - 200kW

For systems with variable speed pumps and water flow, a 2 port control valve can be fitted. The two port valve has a
shut off pressure of 13.6 Barg.

SN, SR 2 Port Valve

Introduction

0-10 Volts DC 2 Port Chilled Water Regulating Valve (SN, SR, SD Units)

SD 2 Port Valve

0-10 Volts DC 2 Port Chilled Water Regulating Valve with bypass for auto commissioning (SD Units)
For systems with variable speed pumps and water flow, a 2 port control valve can be fitted The two port valve has a
shut off pressure of 13.6 Barg.

A bypass leg fitted with a further 2 port valve enables auto commissioning.
The auto commissioning shall be enabled by using a differential pressure transducer to maintain balanced water flow
through the bypass. The controller maintains the same pressure drop through the coil and the bypass. A fixed flowrate is
required for this initial commissioning to occure.

SD 2 Port Valve with Bypass

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

17

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Airflow Components

SR, SN Ranges

SD Range

System Configuration
Range

Chilled Water

Number of Circuits

SN

SR

SD

Single

Single

Dual

Single

Dual

EC Backward Curved Centrifugal Fans in Unit

EC Backward Curved Centrifugal Fans in Floorstand

G4 Air Filtration

High Grade F7 Filtration

Airflow Monitoring

Airflow Switch

Constant Air Volume

Constant Pressure Control

Standard Features

Optional Features

Feature Not Available

Fan & Motor Assembly

Backward curved impellers, direct drive centrifugal fan assemblies shall be used with integral EC motors. They shall be
dynamically balanced for quiet operation.
Fan speed, air flow and external static pressure shall be controlled by the use of a voltage controller which shall
maintain optimised performance and reduce energy consumption.
Designed for high corrosion resistance, the impellers shall be composite plastic with a galvanised rotor.

18

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW
Introduction

Electronically Commutated (EC) Fan Motor

The fans offer maximum air flow performance while keeping sound
levels to a minimum.
It gives the flexibility of connecting to AC mains with the efficiency
and simple speed control of a DC motor. The EC fan offers significant
power reduction in comparison with an equivalent AC fan at modulated
fan speeds. The inbuilt EC fan control module allows for fan speed
modulation from 15-100%.
A standard AC fans modulating range is typically 40 -100% of full fan
speed.

Input Power

EC motors incorporate integrated electronics to convert AC power to


DC for efficient and accurate speed control and are adjustable via the
microprocessor display keypad.

Airflow
Key

EC (Electronically Commutated) Fan Speed Control

Standard voltage regulated (VR) fan speed controllers offer a linear


response. The illustration on the right shows a comparison of the typical
power input required by each method.

Regulated (VR) Fan Speed Control

G4 Filtration

Pleated disposable panel filters in a rigid frame. Conform to BS EN 779-G4.


Access and removal from unit front.
As standard the microprocessor provides an alarm following a pre set run time limit being exceeded.

High Grade F7 Filtration

Pleated disposable panel filters conforming to BS EN 779-F7 shall be provided.

Air Flow Switch

An adjustable differential pressure switch shall activate a visual alarm at the status panel and break the power supply in
the event of a fan or motor failure.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

19

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Electrical Components

System Configuration
Range

Electrical

Number of Circuits

SN

SR

Single

Single

Dual

Single

Dual

Door Interlocked Mains Isolator

Electrical Switch Gear

Customer Connection Terminals

Power Monitoring

Phase Monitoring Relay

Ultra Capacitive Module (Controller Power Backup)*

Dual Power Supply

Variable Humidification

Electric Heating

Modulating Electric Heating

Standard Features

Optional Features

Feature Not Available

* Fitted as standard when dual power supply is fitted.

20

SD

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW
Introduction

Electrical Panels

The control panel contains the necessary contactors, transformer, sub circuit protection, volt free contacts for a common
alarm and mains and inter-connecting terminals. The panel is situated within the cabinet and can be opened to allow for
essential maintenance of other components within the unit (SN, SR Units only). The electrical control panels are wired to
the latest European standards and codes of practice.

Control Panel Closed (SN, SR Units)

Control Panel Open (SN,SR Units)

SD Units

Optional Control Panel

Optional Control Panels are


fitted dependent on which
optional featurers are fitted.

Standard Control Panel

Optional Control Panel

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

21

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Electric Heating
SN, SR Units

These shall be multi-stage finned electric heating elements complete with auto and manual reset overheat cut-out
protection, element shall be phase balanced for increased efficiency.
The electric heating elements are designed to be located between coil blocks, prior to fans. This enables the unit to
effectively re-heat the air and evenly distribute the temperature within the floor void. All sizes of electric heating are
configurable based upon customer requirements.
A maximum bank of 7.5kW is allocated per coil block The avaliable heating shall be 3kW, 6kW or 7.5kW. Consequently
the level of configuration is dependent on the number of coils in the unit.

SD Units

These shall be multi-stage finned electric heating elements complete with auto and manual reset overheat cut-out
protection, element shall be phase balanced for increased efficiency.
The electric heating elements are designed to be located within the units fan module. This enables the unit to effectively
re-heat the air and evenly distribute the temperature within the floor void. All sizes of electric heating are configurable
based upon customer requirements.
A bank of 7.5kW is allocated per fan and as standard each can be downsized in banks of 7.5kW. Consequently the level
of configuration is dependent on the number of fans in the unit.

Electric Heating Thyristor Control

In addition to the electric heat option a 0 100% Thyristor shall be provided to deliver accurate heating control.

SN06
3kW Electric Heat
6kW Electric Heat
7.5kW Electric Heat
15kW Electric Heat
22.5kW Electric Heat
30kW Electric Heat

SN09

SN12

Standard Features Optional Features


22

SR09

SR12

SR15

SR18

Feature Not Available

SD18

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

SD22

SD25

SD31

SD35

Precision Air Conditioning

SmartCool 6 - 200kW
Introduction

Humidification
SR and SN Ranges

The SmartCool SR and SN range have configurable


humidification selections delivering 3, 8,15 kg/hr:
SN06 configurable with 3kg/hr only
SN09 - SR15 configurable between 3 - 8kg/hr
SR15 to SR18 configurable between 3 -15kg/hr

SD Range

The SmartCool SD Range has configurable


humidification selections delivering 3,8,15 or 30 kg/hr
SD18 configurable between 3-8 kg/hr
SD22-SD35 configurable between 3-30 kg/hr

The flexibility of the humidification options across the SmartCool SD range enables the humidification to be configured
to meet the customers design requirements and conditions.
Note: the 30 kg/hr option utilises 2x 15 kg/hr bottles.

Humidification Sizes
3kg/hr Humidification
8kg/hr Humidification
15kg/hr Humidification
30kg/hr Humidification

Standard Features

SN06

SN09

SN12

SR09

SR12

Optional Features

SR15

SR18

SD18

SD22

SD25

SD31

SD35

Not Avaliable

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

23

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Humidification
Control Principles

In a humidifier with electrodes, steam shall be produced by passing a current between electrode plates to generate heat.
The higher the current being passed between the electrodes, the greater the quantity of steam that is produced.
To modulate the rate of steam production, this system shall vary the level of water within the cylinder, thereby increasing
the immersion level of the electrodes and the current being passed between them. The more conducting area that is
available to pass current between the electrodes, the larger the amount of steam that shall be produced.
Modulated by the controller, the water level is varied so that the level of steam being produced ensures that the room
humidity set-point is continually maintained within a tight tolerance.

Optimised Lifetime

The life span of the Airedale humidification system shall be optimised by the inclusion of a water conductivity sensor
into the bottle feed. This sensor shall determine the conductivity level of the supply water and by using an algorithm
embedded in the software, determines the frequency that the bottle should be drained.
Example: (Optimised Lifetime with High Water Conductivity Supply)
As liquid water is boiled off into steam, mineral deposits are left in solution increasing the conductivity of the water.
To counter this, the intelligent software increases the frequency of drain meaning that the replenishing supply water
keeps the concentration of minerals diluted. By maintaining an acceptable mineral concentration, the bottle lifespan is
maximised.

De-humidification

(With Electric Heating and Humidification only)


Controlled by the microprocessor the de-humidification feature reduces fan speeds by 20% (adjustable). The reduction
of fan speed increases de-humidification which means that the time taken to reduce the room humidity to the required
level is drastically decreased, along with the energy required to do so.
The return temperature is monitored during de-humidification to ensure that the temperature does not fall to a critical
level. If the temperature reaches the low limit de-humidification is cancelled until the return air temperature increases.

24

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Humidification shall be provided by an electrode boiler. The sealed humidifier design shall ensure that only clean sterile
steam is supplied to the conditioned area and corrosive salts and minerals are held in the disposable bottle. The steam
shall be distributed through a sparge pipe fitted to the coil assembly.
Featuring modulating capacity output control as standard, the system shall provide continuous modulation of steam
output in response to a proportional control signal. The output control shall range from 20%-100% of the humidifier rated
value and be designed to give an approximate steam output of +/- 5% at 25C (at the sensor), thus ensuring precise
control of the conditioned space.

Introduction

Humidifier - Intelligent Modulation

The cylinder operating life time shall be automatically optimised via the integrated water conductivity sensor, which
combined with the controls shall monitor and regulate the water refill cycle to reduce excessive salt deposits and the
progressive wear of the cylinder.
All humidifier parameters and alarms shall be accessible and adjustable via the microprocessor display keypad unit,
main features shall include not less than:
Supply water conductivity (S/cm)
Actual steam output (kg/h)
Required steam output (kg/h)
Actual current rating (A)
Required current rating (A)
Status mode (Start Up, Running, Filling, Draining)

Water Conductivity & Cylinder Type

Three different cylinders shall be available which correspond to the supply water conductivity.
The cylinder type shall be matched with the standard conductivity of the supply water to ensure optimum performance
and to increase the life span of the cylinder.
1
2
3

Low Conductivity (Soft Water)


Standard Conductivity (Moderate / Hard Water)
High Conductivity (Very Hard Water)

100 to 350 S/cm


350 to 750 S/cm
750 to 1250 S/cm

Conductivity is a measure of the ability of water to pass an electric current, measured in micro Siemens / centimetre (S/
cm).
As standard the humidifier shall be fitted with the standard conductivity cylinder which shall cover the majority of water
supplies.
Where the water conductivity is known, please specify at order.
For further details please contact Airedale.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

25

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Dual Power Supply

The SmartCool range shall be designed with dual power supply capability,
so that in the event of a power failure the supply can be switched from utility
to an alternative power supply (such as second utility or generator).
A dual power supply changeover switch shall be provided to enable
continuous power to the SmartCool in order to reduce unit downtime and
therefore loss of cooling to a minimum.
For the dual power supply feature to operate effectively the two incoming
power supplies must have the same voltage and frequency.
During changeover of power there is an interval of 180ms with no power.
For critical applications a power backup module can be added to maintain
power to the unit controls, allowing for immediate reinstatement of cooling
following changeover.
The option as standard offers switch position status and supply priority set,
both of which are configurable via the units display.
Supply priority set is fully configurable via the units display and is used to
set which of the two power supplies power will be drawn from when both
power supplies are active.
Switch position status indicates to the end user which position the switch is
currently in i.e. A or B and is shown via the units display.
When the dual power supply is fitted the UltraCap UPS is fitted as standard.

Ultracap UPS

The Ultracap module is an external backup device for the controller. The
module guarantees temporary power to the controller in the event of power
failures and allows for enough time to keep the controller running with time to
change power supplies.
The module is made using Ultracap storage capacitors (EDLC = Electric
Double Layer Capacitor), which are recharged independently by the module.
These ensure reliability in terms of much longer component life than a module
made with lead batteries: the life of the Ultracap module is at least 10 years.
When the dual power supply is fitted the Ultracap UPS is fitted as standard.

Energy Manager

Analysis of system energy consumption can be monitored via a


dedicated LCD display. Unit parameters can be adjusted via the unit
microprocessor control to affect energy usage in line with the system
need.

26

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW
Introduction

Controls

Display for illustration only

System Configuration
Range

Controls

Number of Circuits

SN

SR

SD

Single

Single

Dual

Single

Dual

PCO5 Microprocessor

Airetronix Controls

PGD1 Display (Door Mounted)

PGD1 Display with Audible Alarm (Door Mounted)

PDG Touch Display

Constant Air Volume

Constant Pressure Control

Temperature Control

Temperature & Humidity Control

Supply Air Temp Control

NTC Water Temperature Sensor / Probe

Filter Change Switch

BMS and SNMP Compatibility

Drip Tray Level Detection

Fire Detection

Smoke Detection

Water Detection

Standard Features

Optional Features

Feature Not Available

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

27

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Controls

The units shall be supplied with a European ROHS Directive 2002/95/EC compatible microprocessor controller
connected to an 8 x 22 back-lit LCD keypad display. LEDs shall not be acceptable.
The microprocessor controller offers powerful analogue and digital control to meet a wide range of monitoring and
control features including a real time clock and Industry standard communication port and network connections.
All the boards feature a 16 bit microprocessor, and consequently the calculation power and operation processing speed
have been significantly increased.
Also featured are a visual alarm and the facility to adjust and display control settings by local operator for information
and control.

Display / Keypad

The display keypad features a simple array of keys to navigate through the in built menus.
With an 8 x 22 character (132 x 64 pixel) screen size, back lit in white for improved contrast, the larger screen shall
provide for user friendly viewing and easy status recognition by displaying a combination of text and icons.
The default screen shall show the unit status and room condition (C/RH %) without the need for interrogation and an
easy to navigate menu structure for further interrogation and adjustment shall be provided.

Fan Operating

De-humidification

Cooling - Up to 6 Stages
Humidification - Variable

Heating - Various Stages


SN - 2 Stages
SR - 3 Stages
SD - 4 Stages

28

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Password Protection

The control system integrity shall be maintained by restricting access with a password PIN number.

IMPORTANT

Introduction

Controls

To change the PIN , please contact Airedale at time of order with the preferred 4 digit number.

Remote On/Off

Terminals for interlocking shall be provided to enable or disable the unit remotely.

Fire Shut Down

Terminals for interlocking shall be provided to shut down the unit in the event of fire.

Evaporator Fan Hours Run Log & Reset

Shall allow the user to monitor the running times of the evaporator fans and reset after maintenance.
Hours run log or visual service indicator shall be provided.

Evaporator Fan Speed Control

Evaporator fan speed control shall be easily set via the display keypad and can be incrementally increased or decreased
to meet on site airflow and external static pressure requirements.

Filter Change Alarm

Filter change shall be managed by the software, and shall be based on fan(s) hours run with an alarm being generated
when the pre-set run time limit has been exceeded. The set-point value shall be adjusted to suit each application and is
factory set to 4000 hours.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

29

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Controls
Standard Network Features

As standard the controller shall be capable of providing a platform for the following and shall be enabled on request for 2
to 8 units, please specify at order:

Networking

A Local Area Network (pLAN ) shall be used to connect up to 8 units to offer intercommunication and Run / Standby
control. This also allows the connection of computers, printers and modems on the same communications ring.
For further details, please contact Airedale Controls.

CAUTION

When adding to an existing network, please consult Airedale to ensure strategy compatibility.

Run / Standby Operation

The controller shall enable units to operate in run/standby mode, with up to 8 units networked together, without the need
for additional hardware or controllers. Standby units shall be configured to start when the run unit has a critical alarm.

Smart Key

A smart key shall be supplied to offer software back-up of the control strategy. The key shall feature simple plug in
operation and allow transfer of software programs from the key to the microprocessor and vice versa. The use of a
service laptop shall not be necessary.

Audible Alarm

The display keypad shall be upgraded to include audible alerts.

Water Detector

Three methods shall be available:


1.
A solid state (probe) sensor shall be supplied loose for remote mounting on site.
2.
Tape suitable for sensing water droplets shall be supplied loose for remote mounting on site. Standard tape

length 10m.
3.
Condensate drain tray level detection.

Fire Detection

Shall be supplied loose for installation in the return air stream to shut down the unit in the event of an unusually high
return air temperature.

Smoke Detector

Shall be supplied loose for remote mounting to shut down the unit and activate the alarm upon sensing the presence of
smoke.

30

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Temperature Control

A temperature sensor shall be mounted in the return air side of the unit to sense the return dry bulb condition (cooling
only variants). A combined temperature and humidity sensor shall be supplied on full function units.

Introduction

Controls

The temperature sensor shall be an NTC type thermistor with an accuracy of not less than +/ - 5% at 25C at the sensor.
The microprocessor shall sense the return air conditions and maintain the return air temperature and humidity by
controlling cooling, heating, humidification and dehumidification outputs accordingly.
The microprocessor shall monitor and display the following values as a minimum:

Return Air Temperature

Return Air Humidity (Optional on Full Function units)

Fan run hours

Coil Temperature Sensor (Indoor)
The maintenance of key components such as air filters shall be monitored via a service indicator which visually
demonstrates the status relative to the component service intervals.

Alarm Log

The controller shall log and allow viewing of not less than the last 100 conditions recorded in descending chronological
order through the keypad display.
The standard display keypad shall visually display operating alarms, however, as an optional extra, a display keypad
with audible alarms is available.

Supply Air Temperature Control

Modulation of unit capacity to ensure that user defined supply air set points shall be maintained and / or a high / low
return air temperature alarm.
During peak demand, the standby units shall temperature assist.

Duty Rotation

Networked units shall be configured to duty rotate, providing equal hours run of fans.

BMS Interface Cards

BMS Interface Card controlled units shall be interfaced with most BMS, factory fitted, please contact Airedale.
A wide range of protocols shall be accommodated through the use of interface devices. Available as a standard option
are: ModBus / Jbus, and Carel.
For interfaces such as SNMP, LonWorks, Metasys and BACnet, please contact Airedale.
Also available shall be Airedales own supervisory plug-in BMS card pCOWEB.
Based on Ethernet TCP/IP secure technology with SNMP features.
It shall require no proprietary cabling or monitoring software and be supplied pre - programmed with an IP address for
ease of set up. Cables to the BMS to be supplied by others.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

31

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Constant Pressure Control

Constant pressure control is a method of controlling air pressure within a space, such as a floor void or a duct. The air
pressure is controlled using a variable speed fan that is modulated to maintain a given set point.
Constant pressure control monitors the air pressure differential between two points. In a typical application (shown
below) the pressure under the raised floor (red) is compared to the room pressure (blue).

The two pressure points, positive and negative, are routed back to an air differential pressure sensor inside the CRAC
unit. The value from the air pressure sensor is compared to the set point and a fan speed demand is generated, to
maintain the required pressure differential.
It is the responsibility of the installer to fit the air pressure sensor(s). The sensor shall be be located under the false
floor with the 6mm flamtronix tubing routed back into the control panel of the unit (the tubing must not be obstructed /
damaged to ensure accurate pressure control).
The contant pressure system shall be commissioned by Airedale following routing of tubing from the pressure diffuser
and the unit.
A maximum of 8m/s air velocity is allowed at the diffuser so consideration must be made to its location.

Constant Air Volume

Constant air volume is a method of automatically adjusting the unit fan speed to deliver a specific air volume.
When faced with a change in system resistance, the fan speed modulates to obtain the air volume set point.
Constant air volume monitors the air pressure differential between two points.
These two pressure points, positive and negative, are routed back to an air differential pressure sensor inside the unit.

32

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW
Introduction

General Features

System Configuration
Range
Circuits
Condensate Pump (Hot or Cold Water)*

General

Condensate Drain Tray Monitoring


Straight and L Shaped Ceiling Duct Extensions
Open Floorstand
Front and Rear Floorstands (enclosed)
UPS Floorstand
Sterling Board LAT (Wooden Case) Packing

Standard Features

Optional Features

SN

SR

SD

Single

Single

Dual

Single

Dual

Feature Not Available

* Condensate pump type depends if humidification is selected


Open & Enclosed Floorstand

Open or enclosed floor stands shall be available, complete with adjustable feet and floor tile lip. Enclosed floor stands
shall incorporate an air turning vane (SN,SR only). The height of the floor stand shall be specified at order.

Discharge Air Configuration

Standard configuration shall be downflow draw through design.

Straight and L shaped Ceiling Duct Extension

Straight and L shaped duct extensions up to a height of 1350mm shall be constructed and finished to match the unit.
For extensions greater than 1350mm, please contact Airedale.
Height shall be specified at order.

Sterling Board LAT (Wooden Case) Packing

Units shall be supplied complete with additional LAT corner protection and cross braces to afford extra transit protection.
Sterling board heat treated man made material shall be used (including pallet) to comply with phytosanity import
regulations, please contact Airedale for this option).

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

33

Introduction

SmartCool 6 - 200kW

Precision Air Conditioning

Condensate Pumps

The SmartCool condensate pump shall be either hot water (full function units when a humidifier is fitted) or cold water
type (cooling only).

Performance

The following graphs illustrate the TOTAL static (head) pressure available. The system horizontal pipe losses and
vertical lift should be factored in when calculating the condensate pump performance.

Cold Water (Cooling only units)


SN, SR Units

The cold water condensate


pump has 10mm quarter turn
plastic barbed connection.

5
Head (m)

4
3
2
1
0
0.0

0.5

1.0

1.5

SD Units

2.0

2.5

3.0

Head (m)

Flow Rate (l/min)

9
8
7
6
5
4
3
2
1
0
2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

Flowrate l/min

Hot Water (Full function units, SN,SR,SD type units)


12
10

The hot water condensate


pump uses 10mm (3/8) copper
tube when connecting to the
discharge stub of the pump.

Head (m)

8
6
4

Important

2
0

5.0

7.0

9.0

11.0

Flow Rate (l/min)

Condensate Drain Tray Monitoring

13.0

15.0

The discharge line from the pump


should rise no more than 6 metres
vertically and no more than 8 metres
in total length before being interrupted
with a swan neck air break and
tundish.

A float level switch shall be incorporated into the unit drain tray for indication of a high water alarm.

34

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

All sound data quoted has been measured in the third-octave band limited values, using a Real Time Analyser calibrated
sound intensity meter in accordance with BS EN ISO9614 Part 1: 1995.
All Sound Power Levels quoted are calculated from measured sound intensity according to BS EN ISO9614 Part 1:
1995.

Introduction

Measurement of Sound Data

Semi Hemispherical

Sound Pressure Levels are calculated from sound power using the semi-hemispherical method where the noise source
is in junction with 2 boundaries i.e. the floor and 1 wall.

Free Field

For comparison, the semi hemispherical figures can typically be reduced by 6dB to provide free field conditions.

IMPORTANT

The sound data quoted is based on the unit having a ducted return air and standard backwards curved EC motors fitted,
refer to illustration below.
Case breakout sound data is therefore independent of the discharge air and return air sound data.
For non-ducted return air applications, the overall case breakout sound levels may increase, due to the return air sound
being predominant.
Within the conditioned space, sound from in-room ducted discharge air grilles and other equipment will contribute to the
overall sound level and should therefore be considered as part of sound calculations.
Specialist acoustic advice is recommended for noise critical applications.

(1)

(2)

(3)

(1)
(2)
(3)

Return Air
Case Breakout
Discharge Air

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

35

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions

Installation

SN 06D - C000

171

600

570

165

270

165

342

15

684
171

15

654

M6 FIXINGS
EIGHT POSITIONS

600

684

1980

RETURN AIR

FRONT
DISCHARGE AIR

36

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

REAR

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SN 09D - C000

Installation

240.8

600

570

165

270

165

481.5

15

963
240.8

933

15

RETURN AIR

600

1980

963

FRONT

REAR

DISCHARGE AIR

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

37

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions

1242
621

310.5

570
600

165

270

165

310.5

15

Installation

SN 12D - C000

1212

15

RETURN AIR

600

1980

1242

FRONT
DISCHARGE AIR

38

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

REAR

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SR 09D - C000 / C0C0

Installation

240.8

890

860

180

530

180

481.5

15

963
240.8

15

933

890

963

1980

RETURN AIR

FRONT

REAR

DISCHARGE AIR

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

39

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions

Installation

SR 12D C000 / C0C0

310.5

890

860

180

530

180

621

15

1242
310.5

15

1212

890

1242

1980

RETURN AIR

FRONT
DISCHARGE AIR

40

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

REAR

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SR 15D - C000 / C0C0

Installation

760.5

380.2

890

180

530

860

180

380.2

15

1521

15

1491

890

1521

1980

RETURN AIR

FRONT
REAR
DISCHARGE AIR

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

41

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions

Installation

SR 18D C000 / C0C0

450

860
890

180

530

180

900

15

1800
450

15

1770

890

1800

1980

RETURN AIR

FRONT
DISCHARGE AIR

42

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

REAR

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SD 18 Single Circuit
RETURN AIR

Installation

900
1770

450

15

890

15

180

860

530

180

15

450
15

890

1980

1800

FLOOR LEVEL

600 MIN

FLOOR LEVEL

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

43

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions
SD 22 Single Circuit

Installation

RETURN AIR

1000
2170

600

15

530

15

180

860

180

15

600
15

2200

1980

890

FLOOR LEVEL

600 MIN

FLOOR LEVEL

44

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SD 25 Single Circuit

600

600

1300

15

2470

15

180

860

530

180

15

15

Installation

RETURN AIR

2500

1980

890

FLOOR LEVEL

600 MIN

FLOOR LEVEL

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

45

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions
SD 31 Single Circuit

Installation

RETURN AIR

1500
3070

800
15

530

15

180

860

180

15

800
15

890

1980

3100

FLOOR LEVEL
600 MIN

FLOOR LEVEL

46

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SD 35 Single Circuit

900

15
180 530 180

1700
3470

15

860

15

900
15

Installation

RETURN AIR

3500

1980

890

FLOOR LEVEL
600 MIN

FLOOR LEVEL

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

47

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions
SD 18 Dual Circuit

Installation

RETURN AIR

15

900
1770

450
15

530

15

180

860

180

15

450

1800

1980

890

FLOOR LEVEL

600 MIN

FLOOR LEVEL

48

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SD 22 Dual Circuit

600

1000
2170

600

15

530

15

180

860

180

15

15

Installation

RETURN AIR

2200

1980

890

FLOOR LEVEL

600 MIN

FLOOR LEVEL

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

49

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions
SD 25 Dual Circuit

Installation

RETURN AIR

1300
2470

600
15

15

180

530

860

180

15

600
15

2500

1980

890

FLOOR LEVEL
600 MIN

FLOOR LEVEL

50

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

RETURN AIR

Precision Air Conditioning

SmartCool 6 - 200kW

Installation Data
Dimensions
SD 31 Dual Circuit

1500
3070

800

15

530

15

180

860

180

15

800
15

Installation

RETURN AIR

3100

1980

890

FLOOR LEVEL

589

FLOOR LEVEL

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

51

SmartCool 6 - 200kW

Precision Air Conditioning

Installation Data
Dimensions
SD 35 Dual Circuit

Installation

RETURN AIR

1700
3470

900
530 180

15

15

180

860

15

900
15

890

1980

3500

FLOOR LEVEL
600 MIN

FLOOR LEVEL

52

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Positioning

Installation

Minimum Unit Clearance SN, SR


Open and Enclosed Floorstand Option
A

B
600

SN06D

mm

684

SN09D / SR09D

mm

963

880

SN12D / SR12D

mm

1242

880

SR15D

mm

1521

880

SR18D

mm

1800

880

C - Floorstand(3)

Min 350 Max 750


(+ 50mm Feet Adjustable +/-20mm) (4)

Minimum Ceiling Clearance- (D)


Forward Only

Forward and 1 Side

Forward and 2 Sides

All Faces

SN06D

mm

720

500

380

250

SN09D / SR09D

mm

720

500

380

250

SN12D / SR12D

mm

720

500

380

250

SR15D

mm

740

550

440

280

SR18D

mm

750

590

480

300

(1) Shown with optional open floor stand.


(2) Shaded area indicates minimum service and maintenance requirements. The unit must be installed with allowance for carpet tile clearance.
(3) Dimension C denotes recommended minimum/maximum floor stand height, refer to Airedale for special applications, please specify at order.
(4) Min = Threaded foot at minimum extension (additional to C dimension).
Max = Threaded foot at maximum extension (additional to C dimension).

Packed Dimensions

For specific markets units shall be shipped, mounted on


wooden pallet and covered with polythene. The pallet shall
be mechanically fixed to the unit for transportation only
(Please contact Airedale for this option). Add 50mm to
length and width, 160mm to height.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

53

SmartCool 6 - 200kW

Precision Air Conditioning

Installation

Positioning

Minimum Unit Clearance SD


Open and Enclosed Floorstand Option

B
880

SD18D

mm

1800

SD22D

mm

2200

880

SD25D

mm

2500

880

SD31D

mm

3100

880

SD35D

mm

3500

880

C - Floorstand(3)

Min 600 Max 750

Minimum Ceiling Clearance- (D)

SD18D

mm

Forward Only

Forward and 1 Side

Forward and 2 Sides

All Faces

720

500

380

250

SD22D

mm

720

500

380

250

SD25D

mm

720

500

380

250

SD31D

mm

740

550

440

280

SD35D

mm

750

590

480

300

(1) Shown with standard open floor stand.


(2) Shaded area indicates minimum service and maintenance requirements. The unit must be installed with allowance for carpet tile clearance.
(3) Dimension C denotes recommended minimum/maximum floor stand height, refer to Airedale for special applications, please specify at order.

54

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Pipework Schematics
SN Single Circuit

BL

BL

BL

BL

Installation

BI
SN06
2 COILS

M
WTS

DR

BI

BI

OPTIONAL

BI

BL

BINDER POINT

WTS

BLEED VALVE

DRAIN VALVE

SN12
4 COILS

OPTIONAL

M
DR

SN09
3 COILS

WATER TEMPERATURE SENSOR

2-WAY REGULATING BALL VALVE


(ACTUATOR DRIVEN)

THREADED CONNECTION (BSPT MALE)

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

55

SmartCool 6 - 200kW

Precision Air Conditioning

Pipework Schematics
SN Single Circuit

BL

BL

BL

Installation

BL

BI

SN06
2 COILS

OPTIONAL

WTS

BI

BL

DR

OPTIONAL

BINDER POINT

WTS

BLEED VALVE

M
DR

DRAIN VALVE

WATER TEMPERATURE SENSOR

3-WAY REGULATING BALL VALVE


(ACTUATOR DRIVEN)

THREADED CONNECTION (BSPT MALE)

2-WAY REGULATING BALL VALVE

56

SN12
4 COILS

BI

OPTIONAL

BI

SN09
3 COILS

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Pipework Schematics
SR Single Circuit

BL

BL

BL

BL

Installation

BL

BL

BI

SR09
3 COILS

SR12
4 COILS

SR15
5 COILS

SR18
6 COILS

M
WTS

DR

BI

BI

OPTIONAL

BI

BL

OPTIONAL

BINDER POINT

WTS

BLEED VALVE

M
DR

DRAIN VALVE

WATER TEMPERATURE SENSOR

2-WAY REGULATING BALL VALVE


(ACTUATOR DRIVEN)

THREADED CONNECTION (BSPT MALE)

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

57

SmartCool 6 - 200kW

Precision Air Conditioning

Pipework Schematics
SR Single Circuit

Installation

BL

BL

BL

BL

BL

BL

BI

SR09
3 COILS
M
WTS

OPTIONAL

BI

BL

OPTIONAL

BINDER POINT

WTS

BLEED VALVE

DRAIN VALVE

WATER TEMPERATURE SENSOR

3-WAY REGULATING BALL VALVE


(ACTUATOR DRIVEN)

THREADED CONNECTION (BSPT MALE)

2-WAY REGULATING BALL VALVE

58

SR18
6 COILS

DR

M
DR

SR15
5 COILS

BI

OPTIONAL

BI

SR12
4 COILS

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Pipework Schematics
SR Dual Circuit
OPTIONAL

OPTIONAL
BI

WTS

DR

Installation

BI

BI

BL

BL

BL

BL

BL

BL

BL

BL

BL

BL

BL

BL

BI

SR09
3 COILS

M
WTS

DR

BI

BI

OPTIONAL

BI

BL

BINDER POINT

WTS

BLEED VALVE

DRAIN VALVE

SR15
5 COILS

SR18
6 COILS

OPTIONAL

M
DR

SR12
4 COILS

WATER TEMPERATURE SENSOR

2-WAY REGULATING BALL VALVE


(ACTUATOR DRIVEN)

THREADED CONNECTION (BSPT MALE)

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

59

SmartCool 6 - 200kW

Precision Air Conditioning

Pipework Schematics
SR Dual Circuit
OPTIONAL

Installation

OPTIONAL
BI

BI

WTS

DR
M

OPTIONAL

BI

BL

BL

BL

BL

BL

BL

BL

BL

BL

BL

BL

BL

BI

SR09
3 COILS

M
WTS

DR

BI

BI

OPTIONAL

BI

BL

BINDER POINT

WTS

SR18
6 COILS

BLEED VALVE

DRAIN VALVE

WATER TEMPERATURE SENSOR

3-WAY REGULATING BALL VALVE


(ACTUATOR DRIVEN)

THREADED CONNECTION (BSPT MALE)

2-WAY REGULATING BALL VALVE

60

SR15
5 COILS

OPTIONAL

M
DR

SR12
4 COILS

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Pipework Schematics
SD Single Circuit
INLET LEG

PDZAL

OPTIONAL BYPASS
LEG

BL

BI

Installation

CHILLED WATER
COIL

WTS

DR

BL

BLEED VALVE (ON HIGHEST POINT OF HEADER)

DR

DRAIN VALVE (ON LOWEST POINT OF


HEADER)

OUTLET LEG

M
BI

SD Dual Circuit
CIRCUIT 1

CIRCUIT 2

INLET LEG

INLET LEG

DR

OUTLET LEG

BL

BL

BLEED VALVE (ON HIGHEST POINT OF HEADER)

DR

DRAIN VALVE (ON LOWEST POINT OF


HEADER)

BI

BINDER POINT

BL

BLEED VALVE

DR

WTS

OUTLET LEG

BL

DRAIN VALVE
WATER
TEMPERATURE
SENSOR

DR

BI

WTS BI

DR

PDZAL

BL

OPTIONAL BYPASS
LEG

BL
CHILLED WATER
COIL

DR

PDZAL

OPTIONAL BYPASS LEG

WTS

CHILLED WATER
COIL

BI

2 WAY
REGULATING
BALL VALVE
(ACTUATOR
DRIVEN)

BI

PDZAL

DIFFERENTIAL
PRESSURE TRANDUCER

CENTRIFUGAL FAN

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

61

SmartCool 6 - 200kW

Precision Air Conditioning

Incoming Services
SN Single Circuit

FRONT OF UNIT

70

72

93

186

272

105

179

80

600

521

92

VIEW FROM ABOVE

451

Installation

79

163.8

684

A
B
E
F
G
H
J

DIA 22mm WATER INLET


DIA 22mm WATER OUTLET
POWER (CONNECT VIA EXTERNAL CONNECTION BOX)
CONTROLS (CONNECT VIA CONNECTORS)
CONDENSATE DRAIN (TEE TO HUMIDIFIER DRAIN - IF USED)
HUMIDIFIER DRAIN (TEE TO CONDENSATE DRAIN)
HUMIDIFIER FILL

Incoming Services
SR Single Circuit

79

75

FRONT OF UNIT

811
343

199

129

254

105

80

632.5

890

92

VIEW FROM ABOVE

98
216

963

A
B
E
F
G
H
J

62

DIA 35mm WATER INLET


DIA 35mm WATER OUTLET
POWER (CONNECT VIA EXTERNAL CONNECTION BOX)
CONTROLS (CONNECT VIA CONNECTORS)
CONDENSATE DRAIN (TEE TO HUMIDIFIER DRAIN - IF USED)
HUMIDIFIER DRAIN (TEE TO CONDENSATE DRAIN)
HUMIDIFIER FILL

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

SR Dual Circuit

G
E

98

75
FRONT OF UNIT

890

199

111
105

343

408

80

632.5

B
259

811

VIEW FROM ABOVE

Installation

92

C
556

79

216

1800

A
B
C
D
E
F
G
H
J

DIA 42mm CIRCUIT 1 WATER INLET


DIA 42mm CIRCUIT 1 WATER OUTLET
DIA 42mm CIRCUIT 2 WATER INLET
DIA 42mm CIRCUIT 2 WATER OUTLET
POWER (CONNECT VIA EXTERNAL CONNECTION BOX)
CONTROLS (CONNECT VIA CONNECTORS)
CONDENSATE DRAIN (TEE TO HUMIDIFIER DRAIN - IF USED)
HUMIDIFIER DRAIN (TEE TO CONDENSATE DRAIN)
HUMIDIFIER FILL

SN, SR Electrical Power Connections


HUMIDIFIER
(OPTIONAL)

FRONT OF
UNIT

CONDENSATE
DRAIN

HUMIDIFIER
DRAIN
FLOOR
LEVEL

HUMIDIFIER
FILL
POWER IN

CUSTOMER POWER
CONNECTIONS

CONTROLS
IN

CONDENSATE PUMP
(OPTIONAL)

VIEW ON RIGHT HAND SIDE


SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

63

SmartCool 6 - 200kW

Precision Air Conditioning

Incoming Services

170

1980

Installation

SD Single Circuit

90 298

FLOOR LEVEL

FLOOR LEVEL

106

WATER INLET

247

2ND GLAND POINT FOR DUAL POWER OPTION


POWER CABLE GLAND POINT

WATER OUTLET

H VARIES
CLIENT SPECIFIED FLOOR VOID

238
115

170

236
115

FLOOR LEVEL

90

368

FLOOR LEVEL

170

1980

SD Dual Circuit

WATER INLET
CIRCUIT 1
WATER INLET
CIRCUIT 2 WATER OUTLET
CIRCUIT 1
WATER OUTLET
CIRCUIT 2
H VARIES
CLIENT SPECIFIED FLOOR VOID

64

108

2ND GLAND POINT FOR DUAL POWER OPTION


POWER CABLE GLAND POINT

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Glycol
Specific Heat Capacity (Cp) (kj/kg K)
Water/Glycol
Temperature C

Ethylene Glycol (Volume) / Freezing Point C


0% / 0C

10% / -4C

20% / -9C

30% / -15C

40% / -23C

Cp

Cp

Cp

Cp

Cp

4.183

3.972

3.815

3.645

3.468

4.181

3.981

3.826

3.660

3.485

30

4.179

3.989

3.838

3.674

3.502

35

4.178

3.998

3.849

3.688

3.518

40

4.179

4.007

3.861

3.702

3.535

45

4.181

4.015

3.872

3.716

3.552

0% / 0C

10% / -4C

20% / -9C

30% / -15C

40% / -23C

20

998

1013

1030

1045

1060

25

997

1012

1028

1043

1058

30

996

1010

1026

1041

1055

35

994

1008

1024

1039

1053

40

992

1006

1022

1036

1050

45

990

1003

1020

1035

1048

Installation

20
25

Density () (kg/m)
Water/Glycol
Temperature C

Ethylene Glycol (Volume) / Freezing Point C

Pressure Drop Correction Factor (Px)


Water/Glycol
Temperature C

20

Ethylene Glycol (Volume)


0%

10%

20%

30%

40%

Px

Px

Px

Px

Px

0.983

1.0125

1.054

1.0958

1.15

(1) All data based upon ASHRAE fundamentals 2001.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

65

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units


Performance Data SN C000
Chilled water inlet and outlet temperatures
Air On

SN06D010-C000-0

Technical

SN06D015-C000-0

SN09D020-C000-0

SN

SN09D025-C000-0

SN12D030-C000-0

10 / 15 C

8 / 14 C

66

10 / 16 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

22 / 50

11.0

9.7

7.1

7.1

8.0

8.0

4.0

4.0

24 / 45

12.8

11.4

8.7

8.7

9.3

9.2

7.9

7.9

26 / 40

14.5

13.0

10.3

10.3

10.9

10.6

9.5

9.5

22 / 50

14.4

13.1

9.6

9.6

10.9

10.9

8.5

8.5

24 / 45

16.8

15.3

11.8

11.8

12.7

12.7

10.7

10.7

26 / 40

18.9

17.5

13.9

13.9

14.7

14.7

12.8

12.8

22 / 50

18.6

16.7

12.2

12.2

14.1

14.1

10.7

10.7

24 / 45

21.7

19.5

15.0

15.0

16.0

16.0

13.6

13.6

26 / 40

24.5

22.2

17.7

17.7

18.7

18.4

16.3

16.3

22 / 50

23.0

21.2

15.5

15.5

17.6

17.6

13.7

13.7

24 / 45

26.9

24.8

19.1

19.1

21.5

21.5

17.3

17.3

26 / 40

30.4

28.3

22.5

22.5

24.0

24.0

20.7

20.7

22 / 50

26.9

24.3

17.8

17.8

20.4

20.4

15.6

15.6

24 / 45

31.3

28.3

21.8

21.8

23.4

23.4

19.8

19.8

26 / 40

35.4

32.3

25.7

25.7

27.1

27.0

23.7

23.7

22 / 50

31.1

28.7

21.0

21.0

23.8

23.8

18.5

18.5

24 / 45

36.3

33.5

25.8

25.8

29.0

29.0

23.4

23.4

26 / 40

41.0

38.3

30.4

30.4

32.5

32.5

28.0

28.0

C0C0
C000

SN12D035-C000-0

7 / 12 C

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SN C000 Units


Performance Data SN C000
Chilled water inlet and outlet temperatures
Air On

SN06D010-C000-0

SN06D015-C000-0

SN09D025-C000-0

SN12D035-C000-0

18 / 24 C

20 / 26 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

33 / 26.7

13.5

13.5

10.9

10.9

7.9

7.9

6.3

6.3

35 / 23.9

14.8

14.8

12.2

12.2

9.1

9.1

7.6

7.6

37 / 21.4

16.1

16.1

13.4

13.4

10.3

10.3

8.7

8.7

33 / 26.7

18.3

18.3

14.8

14.8

10.6

10.6

8.5

8.5

35 / 23.9

20.1

20.1

16.5

16.5

12.2

12.2

10.2

10.2

37 / 21.4

21.8

21.8

18.2

18.2

13.8

13.8

11.8

11.8

33 / 26.7

23.3

23.3

18.8

18.8

13.5

13.5

10.9

10.9

35 / 23.9

25.5

25.5

21.0

21.0

15.6

15.6

13.0

13.0

37 / 21.4

27.7

27.7

23.1

23.1

17.6

17.6

15.0

15.0

33 / 26.7

29.7

29.7

23.9

23.9

17.1

17.1

13.8

13.8

35 / 23.9

32.6

32.6

26.7

26.7

19.8

19.8

16.5

16.5

37 / 21.4

35.4

35.4

29.5

29.5

22.4

22.4

19.0

19.0

33 / 26.7

33.9

33.9

27.3

27.3

19.6

19.6

15.8

15.8

35 / 23.9

37.2

37.2

30.5

30.5

22.7

22.7

18.9

18.9

37 / 21.4

40.3

40.3

33.6

33.6

25.6

25.6

21.8

21.8

33 / 26.7

40.1

40.1

32.3

32.3

23.1

23.1

18.6

18.6

35 / 23.9

44.1

44.1

36.2

36.2

26.8

26.8

22.3

22.3

37 / 21.4

47.8

47.8

39.8

39.8

30.3

30.3

25.8

25.8

SN

SN12D030-C000-0

15 / 20 C

Technical

SN09D020-C000-0

12 / 17 C

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

67

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units

SN06D010-C000

Mechanical Data
SN06D010-C000-0

C0C0
C000

SN

Technical

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

68

Material / Colour
Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP /
Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW

SN06D010-C000-1

SN06D010-C000-2

12.8
0.25

12.8
12.8
0.25
0.25
684 x 600 x 1980
181 / 194
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
13
13
13
0.61
0.61
0.61
18.7
18.7
18.7
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 0.78
1 x 0.78
1 x 0.78

rpm
Pa
m/s

1954 / 2680
552
0.70

1954 / 2680
552
0.70

1954 / 2680
552
0.70

mm
mm

22
22

22
22

kW

6
3.0

22
22
Disposable to BS EN 779-G4
6
2.7

kg/hr
l/m

6
3.0

3
7

3
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

3
7

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SN C000 Units

SN06D010-C000

Electrical Data
Unit Data - Full Function

SN06D010-C000-0

SN06D010-C000-1

SN06D010-C000-2

(1)

Nominal Run Amps

10.3

10.3

18.9

Recommended Mains Fuse Size

16

16

25
5.02

Unit Data - Cooling Only


Nominal Run Amps

2.55

2.55

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

16

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 0.78

1 x 0.78

1 x 0.78

1.6

1.6

3.1

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

3.0

2.7

3.0

Current Per Phase

4.4

4.2

7.9

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

2.25

2.25

2.25

Full Load Amps

3.3

3.5

SN

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

69

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units

SN06D015-C000

Mechanical Data
SN06D015-C000-0

C0C0
C000

SN

Technical

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

70

Material / Colour
Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP /
Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW

SN06D015-C000-1

SN06D015-C000-2

16.8
0.62

16.8
16.8
0.62
0.62
684 x 600 x 1980
181 / 194
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
13
13
13
0.80
0.80
0.80
31.8
31.8
31.8
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 0.78
1 x 0.78
1 x 0.78

rpm
Pa
m/s

2590 / 2680
87
0.95

2590 / 2680
87
0.95

2590 / 2680
87
0.95

mm
mm

22
22

22
22

kW

6
3.0

22
22
Disposable to BS EN 779-G4
6
2.7

kg/hr
l/m

6
3.0

3
7

3
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

3
7

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SN C000 Units

SN06D015-C000

Electrical Data
Unit Data - Full Function

SN06D015-C000-0

SN06D015-C000-1

SN06D015-C000-2

(1)

Nominal Run Amps

10.3

10.3

18.9

Recommended Mains Fuse Size

16

16

25
5.02

Unit Data - Cooling Only


Nominal Run Amps

2.55

2.55

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

16

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 0.78

1 x 0.78

1 x 0.78

1.6

1.6

3.1

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

3.0

2.7

3.0

Current Per Phase

4.4

4.2

7.9

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

2.25

2.25

2.25

Full Load Amps

3.3

3.5

SN

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

71

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units

SN09D020-C000

Mechanical Data
SN09D020-C000-0

C0C0
C000

SN

Technical

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

72

Material / Colour
Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP /
Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW

SN09D020-C000-1

SN09D020-C000-2

21.7
0.65

21.7
21.7
0.65
0.59
963 x 600 x 1980
242 / 262
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
19
19
19
1.03
1.03
1.03
23.2
23.2
23.2
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.5
1 x 2.5
1 x 1.9

rpm
Pa
m/s

2120 / 2970
1126
1.20

2120 / 2970
1126
1.20

2013 / 2720
831
1.20

mm
mm

28
22

28
22

kW

9
6.0

28
22
Disposable to BS EN 779-G4
9
5.4

kg/hr
l/m

9
6.0

8
7

8
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

8
7

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SN C000 Units

SN09D020-C000

Electrical Data
Unit Data - Full Function

SN09D020-C000-0

SN09D020-C000-1

SN09D020-C000-2

(1)

Nominal Run Amps

22.4

22.5

39.4

Recommended Mains Fuse Size

32

32

50
7.8

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 1.96

1 x 1.96

1 x 1.96

5.8

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

6.0

5.4

6.0

Current Per Phase

8.7

8.3

15.8
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SN

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

73

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units

SN09D025-C000

Mechanical Data
SN09D025-C000-0

C0C0
C000

SN

Technical

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

74

Material / Colour
Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP /
Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW

SN09D025-C000-1

SN09D025-C000-2

26.9
1.32

26.9
26.5
1.32
1.18
963 x 600 x 1980
242 / 262
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
19
19
19
1.28
1.28
1.26
35.4
35.4
34.4
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.5
1 x 2.5
1 x 1.9

rpm
Pa
m/s

2474 / 2970
618
1.55

2474 / 2970
618
1.55

2515 / 2720
310
1.55

mm
mm

28
22

28
22

kW

9
6.0

28
22
Disposable to BS EN 779-G4
9
5.4

kg/hr
l/m

9
6.0

8
7

8
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

8
7

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SN C000 Units

SN09D025-C000

Electrical Data
Unit Data - Full Function

SN09D025-C000-0

SN09D025-C000-1

SN09D025-C000-2

(1)

Nominal Run Amps

22.4

22.5

39.4

Recommended Mains Fuse Size

32

32

50
7.8

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 2.5

1 x 2.5

1 x 1.9

5.8

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

6.0

5.4

6.0

Current Per Phase

8.7

8.3

15.8
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SN

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

75

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units

SN12D030-C000

Mechanical Data
SN12D030-C000-0

C0C0
C000

SN

Technical

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

76

Material / Colour
Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP /
Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW

SN12D030-C000-1

SN12D030-C000-2

31.3
0.99

31.3
29.0
0.99
0.78
1242 x 600 x 1980
294 / 319
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
25
25
25
1.49
1.49
1.38
24.8
24.8
21.4
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.4
1 x 2.4
1 x 1.95

rpm
Pa
m/s

1985 / 2400
589
1.75

1985 / 2400
589
1.75

1818 / 2250
557
1.60

mm
mm

35
22

35
22

kW

12
6.0

35
22
Disposable to BS EN 779-G4
12
5.4

kg/hr
l/m

12
6.0

8
7

8
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

8
7

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SN C000 Units

SN12D030-C000

Electrical Data
Unit Data - Full Function

SN12D030-C000-0

SN12D030-C000-1

SN12D030-C000-2

(1)

Nominal Run Amps

22.3

22.4

39.5

Recommended Mains Fuse Size

32

32

50
7.9

Unit Data - Cooling Only


Nominal Run Amps

4.9

4.9

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 2.4

1 x 2.4

1 x 1.95

3.9

3.9

5.9

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

6.0

5.4

6.0

Current Per Phase

8.7

8.3

15.8
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SN

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

77

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units

SN12D035-C000

Mechanical Data
SN12D035-C000-0

C0C0
C000

SN

Technical

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

78

Material / Colour
Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP /
Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW

SN12D035-C000-1

SN12D035-C000-2

36.3
1.75

36.3
33.5
1.75
1.31
1242 x 600 x 1980
294 / 319
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
25
25
25
1.73
1.73
1.60
32.9
32.9
28.2
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.4
1 x 2.4
1 x 1.95

rpm
Pa
m/s

2361 / 2400
85
2.10

2361 / 2400
85
2.10

2138 / 2250
183
1.90

mm
mm

35
22

35
22

kW

12
6.0

35
22
Disposable to BS EN 779-G4
12
5.4

kg/hr
l/m

12
6.0

8
7

8
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

8
7

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SN C000 Units

SN12D035-C000

Electrical Data
Unit Data - Full Function

SN12D035-C000-0

SN12D035-C000-1

SN12D035-C000-2

(1)

Nominal Run Amps

22.3

22.4

39.5

Recommended Mains Fuse Size

32

32

50
7.9

Unit Data - Cooling Only


Nominal Run Amps

4.9

4.9

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 2.4

1 x 2.4

1 x 1.95

3.9

3.9

5.9

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

6.0

5.4

6.0

Current Per Phase

8.7

8.3

15.8
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SN

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

79

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units


Waterside Pressure Drop Data
180
160
140

Pressure Drop (kPa)

Technical

120

100

80
60
40
20
0

SN

0.00

1
2
3

0.50

1.00

1.50

2.00

Flow Rate (l/s)

2.50

3.00

3.50

SN06D010-C000 / SN06D015-C000
SN09D020-C000 / SN09D025-C000
SN12D030-C000 / SN12D035-C000

Includes coil, 2 or 3 port valve and pipework.

C0C0
C000

To calculate 3 port valve pressure drop:


P valve =
where P =

Q

M

Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

80

Valve Kv

SN06 C000

10.0

0.28

SN09 C000

16.0

0.44

SN12 C000

25.0

0.69

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data
Sound Data

SN06D010-C000

SN06D015-C000

125

250

500

1000

2000

4000

8000

Discharge Air

70

64

66

71

69

64

58

51

27

Return Air

68

64

66

69

68

63

58

50

26

Case Breakout

70

68

71

72

69

64

58

51

30

Sound Pressure @ 3m

56

53

57

58

54

50

44

37

15

Discharge Air

81

75

76

81

80

75

69

62

38

Return Air

79

75

76

79

79

73

68

61

37

Case Breakout

81

79

82

83

80

75

69

62

41

Sound Pressure @ 3m

66

64

67

68

65

61

54

48

26

Discharge Air

69

68

70

74

69

60

57

51

34

Return Air

68

68

70

72

68

58

56

50

34

Case Breakout

70

72

75

76

68

60

56

52

37

Sound Pressure @ 3m

56

57

61

61

54

45

42

37

23

Discharge Air

76

73

72

82

75

67

63

57

40

Return Air

75

73

72

80

74

65

62

56

SN09D025-C000

39

Case Breakout

77

77

77

83

74

67

63

57

43

Sound Pressure @ 3m

62

62

63

69

60

52

48

43

29

Discharge Air

69

65

72

73

67

60

57

56

37

Return Air

68

65

72

71

66

58

56

55

SN12D030-C000

36

Case Breakout

70

69

78

75

67

60

57

57

40

Sound Pressure @ 3m

55

55

63

60

52

45

42

42

26

Discharge Air

73

64

74

78

71

64

62

58

44

Return Air

72

64

73

76

70

62

61

57

SN12D035-C000

43

Case Breakout

74

68

79

79

71

64

61

58

47

Sound Pressure @ 3m

59

53

64

65

56

49

47

44

32

SN

63

Technical

SN09D020-C000

Frequency (Hz) dB

Overall
dB(A)

Sound Measurement

(1) dB(A) is the overall sound level, measured on the A scale


(2) All sound data measured at nominal conditions, Discharge Air, Return air and case breakout is sound power.

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

81

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SN C000 Units


Interconnecting Wiring

N1

Neutral (Supply 1)

301

L1 (Supply 1)

302

L2 (Supply 1)

303

L3 (Supply 1)

N2

Neutral (Supply 2)

304

L1 (Supply 2)

305

L2 (Supply 2)

306

L3 (Supply 2)

PE

Protective Earth

502

Fire Detector

583

Fire Detector

583

Smoke Detector

584

Smoke Detector

502

Remote On/Off

522

Remote On/Off

Condensate Pump Supply (230V)

N (3*)

Condensate Pump Supply (230V)

534

Condensate Pump High Level Alarm

535

Condensate Pump High Level Alarm

609

Flood Detection Tape / Probe

610

Flood Detection Tape / Probe

810

Supply Air Temperature Sensor

811

Supply Air Temperature Sensor

560

Non-Critical Alarm N/O

561

Non-Critical Alarm Common

563

Critical Alarm N/O

564

Critical Alarm Common

565

Critical Alarm N/C

881

BMS Connection

882

BMS Connection

883

BMS Connection

C0C0
C000

SN

Technical

CONN17

WIRE

1
2
3
4

502
583 or 584
2
N or 3

PIN 1

Conn 17
CONN14

Conn 14

PIN No.

WIRE

1
2
3
4
5
6
7

502
522
560
561
563
564
565

PIN 1

Conn 16

CONN16

PIN No.

WIRE

1
2
3
4
5
6
7
8

2
N or 3
534
535
609
610
810
811

PIN 1

Conn 14

CONN15

Conn 15

*For 220V/3PH NO neutral units the Neutral connection is replaced with a live phase.

82

PIN No.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

PIN 1

PIN No.

WIRE

1
2
3

881
882
883

Precision Air Conditioning

SmartCool 6 - 200kW

Intentionally Blank

Technical
SN
C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

83

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units


Performance Data SR C000
Chilled water inlet and outlet temperatures
Model

SR09D030-C000-0

Technical

SR09D040-C000-0

SR12D045-C000-0

SR

SR12D055-C000-0

SR15D065-C000-0

SR15D075-C000-0

C0C0
C000

SR18D080-C000-0

84

SR18D095-C000-0

Air On

7 / 12 C

10 / 15 C

8 / 14 C

10 / 16 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

22 / 50

30.0

26.1

19.3

19.3

21.4

20.6

17.3

17.3

24 / 45

34.7

30.4

23.5

23.5

26.9

26.1

21.6

21.6

26 / 40

39.0

34.5

27.6

27.6

29.3

27.3

25.6

25.6

22 / 50

36.6

32.5

24.0

24.0

26.4

25.9

21.5

21.5

24 / 45

42.3

37.7

29.2

29.2

31.6

30.1

26.8

26.8

26 / 40

47.6

43.0

34.3

34.3

36.6

34.7

31.8

31.8

22 / 50

43.5

38.2

28.2

28.2

31.2

30.2

25.3

25.3

24 / 45

50.3

44.4

34.4

34.4

38.9

37.8

31.5

31.5

26 / 40

56.6

50.5

40.3

40.3

42.9

40.3

37.4

37.4

22 / 50

51.9

46.4

34.3

34.3

37.6

37.3

30.8

30.8

24 / 45

60.1

54.0

41.8

41.8

45.2

43.3

38.3

38.3

26 / 40

67.6

61.5

49.0

49.0

52.3

50.1

45.5

45.5

22 / 50

60.4

53.6

39.7

39.7

43.7

42.8

35.6

35.6

24 / 45

70.0

62.4

48.3

48.3

52.3

49.7

44.3

44.3

26 / 40

78.7

71.0

56.6

56.6

60.4

57.4

52.6

52.6

22 / 50

65.8

59.0

43.6

43.6

47.8

47.5

39.1

39.1

24 / 45

76.3

68.6

53.1

53.1

57.4

55.2

48.7

48.7

26 / 40

85.8

78.2

62.3

62.3

66.4

63.8

57.8

57.8

22 / 50

73.1

64.9

48.0

48.0

52.8

51.9

43.1

43.1

24 / 45

84.6

75.5

58.4

58.4

63.2

60.2

53.6

53.6

26 / 40

95.2

85.9

68.5

68.5

73.1

69.5

63.7

63.7

22 / 50

84.7

76.7

56.6

56.6

62.2

62.2

50.8

50.8

24 / 45

98.3

89.3

69.0

69.0

74.4

72.4

63.3

63.3

26 / 40

110.7

101.7

81.1

81.1

86.2

83.7

75.1

75.1

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units


Performance Data SR C000
Chilled water inlet and outlet temperatures
Air On

SR09D030-C000-0

SR09D040-C000-0

SR12D055-C000-0

SR15D075-C000-0

SR18D080-C000-0

20 / 26 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

33 / 26.7

36.0

36.0

29.1

29.1

21.1

21.1

17.1

17.1

35 / 23.9

39.4

39.4

32.5

32.5

24.3

24.3

20.4

20.4

37 / 21.4

42.7

42.7

35.7

35.7

27.4

27.4

23.4

23.4

33 / 26.7

44.9

44.9

36.3

36.3

26.2

26.2

21.2

21.2

35 / 23.9

49.2

49.2

40.5

40.5

30.2

30.2

25.3

25.3

37 / 21.4

53.3

53.3

44.5

44.5

34.1

34.1

29.1

29.1

33 / 26.7

52.7

52.7

42.6

42.6

30.8

30.8

25.0

25.0

35 / 23.9

57.7

57.7

47.5

47.5

35.5

35.5

29.7

29.7

37 / 21.4

62.5

62.5

52.2

52.2

40.0

40.0

34.2

34.2

33 / 26.7

64.2

64.2

51.9

51.9

37.4

37.4

30.3

30.3

35 / 23.9

70.4

70.4

57.9

57.9

43.2

43.2

36.1

36.1

37 / 21.4

76.4

76.4

63.7

63.7

48.7

48.7

41.5

41.5

33 / 26.7

74.2

74.2

59.9

59.9

43.3

43.3

35.1

35.1

35 / 23.9

81.2

81.2

66.9

66.9

49.9

49.9

41.7

41.7

37 / 21.4

88.1

88.1

73.5

73.5

56.3

56.3

48.0

48.0

33 / 26.7

81.7

81.7

66.0

66.0

47.6

47.6

38.5

38.5

35 / 23.9

89.5

89.5

73.7

73.7

54.9

54.9

45.9

45.9

37 / 21.4

97.1

97.1

81.0

81.0

61.9

61.9

52.8

52.8

33 / 26.7

89.8

89.8

72.6

72.6

52.4

52.4

42.4

42.4

35 / 23.9

98.4

98.4

80.9

80.9

60.4

60.4

50.5

50.5

37 / 21.4

106.6

106.6

89.0

89.0

68.1

68.1

58.1

58.1

33 / 26.7

106.3

106.3

85.8

85.8

61.8

61.8

50.0

50.0

35 / 23.9

116.6

116.6

95.9

95.9

71.4

71.4

59.6

59.6

37 / 21.4

126.5

126.5

105.5

105.5

80.5

80.5

68.7

68.7

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

C0C0
C000

SR18D095-C000-0

18 / 24 C

SR

SR15D065-C000-0

15 / 20 C

Technical

SR12D045-C000-0

12 / 17 C

85

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR09D030-C000

Mechanical Data
SR09D030-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material/Colour

86

Cooling Coil
Cooling/Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR09D030-C000-2

34.7
0.8

34.7
34.7
0.8
0.8
963 x 890 x 1980
307 / 337
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
30
30
30
1.65
1.65
1.65
25.9
25.9
25.9
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 1.96
1 x 1.96
1 x 1.96
1174 / 1560
1174 / 1560
1174 / 1560
463
463
463
1.85
1.85
1.85

mm
mm

35
22

kW

9
7.5

kg/hr
l/m

SR09D030-C000-1

8
7

35
22
Disposable to BS EN 779-G4
9
6.8

35
22
9
7.5

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
1 x 3.6
1521 / 2260
1010

4
1.7

(4) kW
rpm
Pa

1 x 3.6
1521 / 2260
1010

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

1 x 3.6
1527 / 2260
1010

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR09D030-C000

Electrical Data
Unit Data - Full Function

SR09D030-C000-0

SR09D030-C000-1

SR09D030-C000-2

(1)

Nominal Run Amps

26.4

26.3

48.5

Recommended Mains Fuse Size

32

32

63
7.9

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 1.96

1 x 1.96

1 x 1.96

5.9

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

7.5

6.77

7.5

Current Per Phase

10.9

10.3

19.7
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

1 x 3.6

1 x 3.6

1 x 3.6

5.8

5.8

11

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

87

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR09D040-C000

Mechanical Data
SR09D040-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material / Colour

88

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR09D040-C000-2

42.3
1.45

42.3
42.3
1.45
1.45
963 x 890 x 1980
307 / 337
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
30
30
30
2.01
2.01
2.01
37.4
37.4
37.4
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 1.96
1 x 1.96
1 x 1.96
1440 / 1560
1440 / 1560
1440 / 1560
202
202
202
2.30
2.30
2.30

mm
mm

35
22

kW

9
7.5

kg/hr
l/m

SR09D040-C000-1

8
7

35
22
Disposable to BS EN 779-G4
9
6.8

35
22
9
7.5

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
1 x 3.6
1863 / 2260
678

4
1.7

(4) kW
rpm
Pa

1 x 3.6
1863 / 2260
678

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

1 x 3.6
1932 / 2260
547

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR09D040-C000

Electrical Data
Unit Data - Full Function

SR09D040-C000-0

SR09D040-C000-1

SR09D040-C000-2

(1)

Nominal Run Amps

26.4

26.3

48.5

Recommended Mains Fuse Size

32

32

63
7.9

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 1.96

1 x 1.96

1 x 1.96

5.9

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

7.5

6.77

7.5

Current Per Phase

10.9

10.3

19.7
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

1 x 3.6

1 x 3.6

1 x 3.6

5.8

5.8

11

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

89

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR12D045-C000

Mechanical Data
SR12D045-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material / Colour

90

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR12D045-C000-2

50.3
1.25

50.3
50.3
1.25
1.25
1242 x 890 x 1980
380 / 420
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
40
40
40
2.4
2.4
2.4
30.8
30.8
30.8
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.9
1 x 2.9
1 x 2.9
1313 / 1660
1313 / 1660
1313 / 1660
508
508
508
2.70
2.70
2.70

mm
mm

42
22

kW

12
15.0

kg/hr
l/m

SR12D045-C000-1

8
7

42
22
Disposable to BS EN 779-G4
12
13.5

42
22
12
7.5

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR12D045-C000

Electrical Data
Unit Data - Full Function

SR12D045-C000-0

SR12D045-C000-1

SR12D045-C000-2

(1)

Nominal Run Amps

35.8

35.2

64.7

Recommended Mains Fuse Size

50

50

80

Nominal Run Amps

5.43

5.43

9.5

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 2.9

1 x 2.9

1 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

15

13.54

15

21.7

20.6

39.4
8

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

Current Per Phase

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

91

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR12D055-C000

Mechanical Data
SR12D055-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material / Colour

92

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR12D055-C000-2

60.1
2.34

60.1
60.1
2.34
2.34
1242 x 890 x 1980
380 / 420
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
40
40
40
2.86
2.86
2.86
41.9
41.9
41.9
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.9
1 x 2.9
1 x 2.9
1592 / 1660
1592 / 1660
1592 / 1660
129
129
129
3.30
3.30
3.30

mm
mm

42
22

kW

12
15.0

kg/hr
l/m

SR12D055-C000-1

8
7

42
22
Disposable to BS EN 779-G4
12
13.5

42
22
12
7.5

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
N/A
N/A
N/A
N/A

4
1.7

(4) kW
rpm
Pa

N/A
N/A
N/A

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

N/A
N/A
N/A

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR12D055-C000

Electrical Data
Unit Data - Full Function

SR12D055-C000-0

SR12D055-C000-1

SR12D055-C000-2

(1)

Nominal Run Amps

35.8

35.2

64.7

Recommended Mains Fuse Size

50

50

80

Nominal Run Amps

5.43

5.43

9.5

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 2.9

1 x 2.9

1 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

15

13.54

15

21.7

20.6

39.4
8

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

Current Per Phase

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

93

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR15D065-C000

Mechanical Data
SR15D065-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material / Colour

94

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR15D065-C000-2

70.0
2.12

70.0
70.0
2.12
2.12
1521 x 890 x 1980
461 / 512
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
51
51
51
3.33
3.33
3.33
46.8
46.8
46.8
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 1.96
2 x 1.96
2 x 1.96
1276 / 1560
1276 / 1560
1276 / 1560
354
354
354
3.80
3.80
3.80

mm
mm

42
22

kW

15
15.0

kg/hr
l/m

SR15D065-C000-1

15
7

42
22
Disposable to BS EN 779-G4
15
13.5

42
22
15
15.0

15
15
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
2 x 3.6
1632 / 2260
903

4
1.7

(4) kW
rpm
Pa

2 x 3.6
1632 / 2260
903

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

2 x 3.6
1701 / 2260
854

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR15D065-C000

Electrical Data
Unit Data - Full Function

SR15D065-C000-0

SR15D065-C000-1

SR15D065-C000-2

(1)

Nominal Run Amps

50.6

50.3

93

Recommended Mains Fuse Size

63

63

125
13.8

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 1.96

2 x 1.96

2 x 1.96

5.9

Stage of Reheat

Number of Elements

15

13.54

15

21.7

20.6

39.4

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

Current Per Phase

Technical

Quantity x Motor Size

Humidifier
kg/hr

15

15

15

kW

11.25

11.25

11.25

Full Load Amps

16.3

17.1

29.6

2 x 3.6

2 x 3.6

2 x 3.6

5.8

5.8

11

SR

Capacity
Rating
First upgrade EC Motor - Per Fan
Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

95

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR15D075-C000

Mechanical Data
SR15D075-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material / Colour

96

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR15D075-C000-2

76.3
2.79

76.3
76.3
2.79
2.79
1521 x 890 x 1980
461 / 512
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
51
51
51
3.63
3.63
3.63
54.4
54.4
54.4
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 1.96
2 x 1.96
2 x 1.96
1400 / 1560
1400 / 1560
1400 / 1560
227
227
227
4.20
4.20
4.20

mm
mm

42
22

kW

15
15.0

kg/hr
l/m

SR15D075-C000-1

15
7

42
22
Disposable to BS EN 779-G4
15
13.5

42
22
15
15.0

15
15
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
2 x 3.6
1792 / 2260
753

4
1.7

(4) kW
rpm
Pa

2 x 3.6
1792 / 2260
753

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

2 x 3.6
1865 / 2260
660

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR15D075-C000

Electrical Data
Unit Data - Full Function

SR15D075-C000-0

SR15D075-C000-1

SR15D075-C000-2

(1)

Nominal Run Amps

50.6

50.3

93

Recommended Mains Fuse Size

63

63

125
13.8

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 1.96

2 x 1.96

2 x 1.96

5.9

Stage of Reheat

Number of Elements

15

13.54

15

21.7

20.6

39.4

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

Current Per Phase

Technical

Quantity x Motor Size

Humidifier
kg/hr

15

15

15

kW

11.25

11.25

11.25

Full Load Amps

16.3

17.1

29.6

2 x 3.6

2 x 3.6

2 x 3.6

5.8

5.8

11

SR

Capacity
Rating
First upgrade EC Motor - Per Fan
Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

97

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR18D080-C000

Mechanical Data
SR18D080-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material / Colour

98

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR18D080-C000-2

84.6
2.22

84.6
84.6
2.22
2.22
1800 x 890 x 1980
528 / 593
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
65
65
65
4.03
4.03
4.03
35.3
35.3
35.3
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1227 / 1660
1227 / 1660
1227 / 1660
557
557
557
4.60
4.60
4.60

mm
mm

54
22

kW

18
22.5

kg/hr
l/m

SR18D080-C000-1

15
7

54
22
Disposable to BS EN 779-G4
18
20.3

54
22
18
22.5

15
15
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR18D080-C000

Electrical Data
Unit Data - Full Function

SR18D080-C000-0

SR18D080-C000-1

SR18D080-C000-2

(1)

Nominal Run Amps

58.7

57.9

105.7

Recommended Mains Fuse Size

80

80

125

Nominal Run Amps

9.86

9.86

17

Recommended Mains Fuse Size

16

16

20

Unit Data - Cooling Only

Max Mains Incoming Cable Size

mm

Mains Supply

70

70

70

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

22.5

20.31

22.5

Current Per Phase

32.5

30.9

59.1

Technical

Quantity x Motor Size

Humidifier
kg/hr

15

15

15

kW

11.25

11.25

11.25

Full Load Amps

16.3

17.1

29.6

SR

Capacity
Rating
First upgrade EC Motor - Per Fan
Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

99

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR18D095-C000

Mechanical Data
SR18D095-C000-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0
C000

SR

Technical

Material / Colour

100

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR18D095-C000-2

98.3
3.8

98.3
98.3
3.8
3.8
1800 x 890 x 1980
528 / 593
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
65
65
65
4.68
4.68
4.68
46.3
46.3
46.3
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1455 / 1660
1455 / 1660
1455 / 1660
325
325
325
5.50
5.50
5.50

mm
mm

54
22

kW

18
22.5

kg/hr
l/m

SR18D095-C000-1

15
7

54
22
Disposable to BS EN 779-G4
18
20.3

54
22
18
22.5

15
15
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units

SR18D095-C000

Electrical Data
Unit Data - Full Function

SR18D095-C000-0

SR18D095-C000-1

SR18D095-C000-2

(1)

Nominal Run Amps

58.7

57.9

105.7

Recommended Mains Fuse Size

80

80

125

Nominal Run Amps

9.86

9.86

17

Recommended Mains Fuse Size

16

16

20

Unit Data - Cooling Only

Max Mains Incoming Cable Size

mm

Mains Supply

70

70

70

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

22.5

20.31

22.5

Current Per Phase

32.5

30.9

59.1

Technical

Quantity x Motor Size

Humidifier
kg/hr

15

15

15

kW

11.25

11.25

11.25

Full Load Amps

16.3

17.1

29.6

SR

Capacity
Rating
First upgrade EC Motor - Per Fan
Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

101

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units


Waterside Pressure Drop Data

180
6

160

140

Pressure Drop (kPa)

Technical

120

100
80
60

SR

40
20
0
0.00

C0C0
C000

4
5
6
7

1.00

2.00

3.00

4.00

Flow Rate (l/s)

5.00

6.00

7.00

8.00

SR09D030 - C000 / SR09D040 - C000


SR12D045 - C000 / SR09D055 - C000
SR15D065 - C000 / SR15D075 - C000
SR18D080 - C000 / SR18D095 - C000

Includes coil, 2 or 3 port valve and pipework.


To calculate 3 port valve pressure drop:
Q

M

P valve =

where
P = Pressure Drop in kPa,
Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.


Unit

102

Valve Kv

SR09 C000

25.0

0.69

SR12 C000

40.0

1.11

SR15 C000

40.0

1.11

SR18 C000

63.0

1.75

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C000 Units


Sound Data

SR09D030-C000

SR09D040-C000

63

125

250

500

1000

2000

4000

Discharge Air

74

73

71

72

73

71

65

56

26

Return Air

73

73

71

71

71

69

64

55

25

SR12D055-C000

SR15D075-C000

SR18D080-C000

75

76

76

74

72

71

64

56

29

60

62

62

60

58

56

50

42

14

Discharge Air

80

78

77

78

78

76

70

61

31

Return Air

78

78

77

76

77

74

69

60

31

Case Breakout

80

82

82

80

78

76

70

62

34

Sound Pressure @ 3m

65

67

67

65

63

62

55

47

20

Discharge Air

76

73

76

75

74

73

67

61

37

Return Air

75

73

76

73

73

71

66

60

36

Case Breakout

77

76

81

77

74

73

66

61

40

Sound Pressure @ 3m

62

62

67

62

59

58

52

47

25

Discharge Air

82

78

81

80

79

79

73

67

43

Return Air

81

78

81

79

78

77

72

66

42

Case Breakout

82

82

87

82

79

79

72

67

46

Sound Pressure @ 3m

68

67

72

68

64

64

58

53

31

Discharge Air

79

78

76

77

78

76

70

61

31

Return Air

78

78

76

76

77

74

69

60

30

Case Breakout

80

81

82

79

77

76

69

61

34

Sound Pressure @ 3m

65

67

67

65

63

61

55

47

19

Discharge Air

82

80

79

80

80

78

72

63

34

Return Air

81

80

79

78

79

77

72

62

33

Case Breakout

82

84

84

82

80

78

72

64

37

Sound Pressure @ 3m

68

69

70

67

65

64

57

49

22

Discharge Air

78

74

77

76

75

74

68

62

38

Return Air

76

74

77

74

74

72

67

61

37

Case Breakout

78

78

82

78

75

74

68

62

41

Sound Pressure @ 3m

64

63

68

64

60

60

53

48

27

Discharge Air

82

78

82

81

80

79

73

67

43

Return Air

81

79

82

79

79

77

72

66

42

Case Breakout

83

82

87

83

79

79

72

67

46

Sound Pressure @ 3m

68

68

72

68

65

64

58

53

31

C0C0
C000

SR18D095-C000

Case Breakout
Sound Pressure @ 3m

SR

SR15D065-C000

8000

Technical

SR12D045-C000

Frequency (Hz) dB

Overall
dB(A)

Sound Measurement

(1) dB(A) is the overall sound level, measured on the A scale


(2) All sound data measured at nominal conditions, Discharge Air, Return air and case breakout is sound power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

103

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C000 Units

SR

Technical

Interconnecting Wiring

N1

Neutral (Supply 1)

301

L1 (Supply 1)

302

L2 (Supply 1)

303

L3 (Supply 1)

N2

Neutral (Supply 2)

304

L1 (Supply 2)

305

L2 (Supply 2)

306

L3 (Supply 2)

PE

Protective Earth

502

Fire Detector

583

Fire Detector

583

Smoke Detector

584

Smoke Detector

502

Remote On/Off

522

Remote On/Off

Condensate Pump Supply (230V)

N (3*)

Condensate Pump Supply (230V)

534

Condensate Pump High Level Alarm

535

Condensate Pump High Level Alarm

C0C0
C000

609

Flood Detection Tape / Probe

Flood Detection Tape / Probe

810

Supply Air Temperature Sensor

811

Supply Air Temperature Sensor

560

Non-Critical Alarm N/O

561

Non-Critical Alarm Common

563

Critical Alarm N/O

564

Critical Alarm Common

565

Critical Alarm N/C

881

BMS Connection

882

BMS Connection

883

BMS Connection

610

CONN17

WIRE

1
2
3
4

502
583 or 584
2
N or 3

PIN 1

Conn 17
CONN14

Conn 14

PIN No.

WIRE

1
2
3
4
5
6
7

502
522
560
561
563
564
565

PIN 1

CONN16

Conn 16

PIN No.

WIRE

1
2
3
4
5
6
7
8

2
N or 3
534
535
609
610
810
811

PIN 1

Conn 14

CONN15

Conn 15

*For 220V/3PH NO neutral units the Neutral connection is replaced with a live phase.

104

PIN No.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

PIN 1

PIN No.

WIRE

1
2
3

881
882
883

Precision Air Conditioning

SmartCool 6 - 200kW

Intentionally Blank

Technical
SR
C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

105

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units


Performance Data SR C0C0
Chilled water inlet and outlet temperatures
Air On

SR09D020-C0C0-0

Technical

SR09D025-C0C0-0

SR12D030-C0C0-0

SR

SR12D035-C0C0-0

SR15D040-C0C0-0

SR15D045-C0C0-0

C0C0

SR18D050-C0C0-0

106

SR18D060-C0C0-0

7 / 12 C

10 / 15 C

8 / 14 C

10 / 16 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

22 / 50

21.5

21.5

15.3

15.3

17.2

17.2

13.1

13.1

24 / 45

25.3

25.3

19.1

19.1

21.0

21.0

17.0

17.0

26 / 40

29.1

29.1

22.7

22.7

24.7

24.7

20.7

20.7

22 / 50

25.9

25.9

18.4

18.4

20.8

20.8

15.9

15.9

24 / 45

30.5

30.5

23.0

23.0

25.3

25.3

20.5

20.5

26 / 40

35.1

35.1

27.4

27.4

29.8

29.8

24.9

24.9

22 / 50

31.0

31.0

22.1

22.1

24.9

24.9

19.0

19.0

24 / 45

36.5

36.5

27.5

27.5

30.4

30.4

24.6

24.6

26 / 40

42.0

42.0

32.8

32.8

35.7

35.7

29.8

29.8

22 / 50

36.6

36.6

26.0

26.0

29.3

29.3

22.5

22.5

24 / 45

43.1

43.1

32.5

32.5

35.8

35.8

29.0

29.0

26 / 40

49.6

49.6

38.7

38.7

42.1

42.1

35.2

35.2

22 / 50

42.8

42.8

30.5

30.5

34.4

34.4

26.3

26.3

24 / 45

50.5

50.5

38.0

38.0

41.9

41.9

33.9

33.9

26 / 40

58.1

58.1

45.3

45.3

49.2

49.2

41.2

41.2

22 / 50

46.3

46.3

33.0

33.0

37.2

37.2

28.5

28.5

24 / 45

54.7

54.7

41.2

41.2

45.4

45.4

36.7

36.7

26 / 40

62.9

62.9

49.1

49.1

53.4

53.4

44.6

44.6

22 / 50

51.7

51.7

36.8

36.8

41.5

41.5

31.8

31.8

24 / 45

61.0

61.0

45.9

45.9

50.7

50.7

41.0

41.0

26 / 40

70.2

70.2

54.8

54.8

59.5

59.5

49.8

49.8

22 / 50

59.3

59.3

42.2

42.2

47.6

47.6

36.5

36.5

24 / 45

70.1

70.1

52.7

52.7

58.1

58.1

47.0

47.0

26 / 40

80.7

80.7

62.9

62.9

68.3

68.3

57.1

57.1

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units


Performance Data SR C0C0
Chilled water inlet and outlet temperatures
Air On

SR09D020-C0C0-0

SR09D025-C0C0-0

SR12D035-C0C0-0

SR15D045-C0C0-0

SR18D050-C0C0-0

20 / 26 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

33 / 26.7

30.5

30.5

24.5

24.5

17.1

17.1

13.6

13.6

35 / 23.9

33.7

33.7

27.5

27.5

20.0

20.0

16.5

16.5

37 / 21.4

36.7

36.7

30.5

30.5

22.8

22.8

19.3

19.3

33 / 26.7

36.9

36.9

29.5

29.5

20.5

20.5

16.3

16.3

35 / 23.9

40.7

40.7

33.2

33.2

24.1

24.1

19.9

19.9

37 / 21.4

44.4

44.4

36.8

36.8

27.5

27.5

23.2

23.2

33 / 26.7

44.1

44.1

35.3

35.3

24.6

24.6

19.6

19.6

35 / 23.9

48.7

48.7

39.8

39.8

28.9

28.9

23.8

23.8

37 / 21.4

53.1

53.1

44.0

44.0

32.9

32.9

27.8

27.8

33 / 26.7

52.2

52.2

41.8

41.8

29.0

29.0

23.1

23.1

35 / 23.9

57.7

57.7

47.0

47.0

34.1

34.1

28.1

28.1

37 / 21.4

62.9

62.9

52.1

52.1

38.9

38.9

32.8

32.8

33 / 26.7

61.0

61.0

48.8

48.8

34.0

34.0

27.0

27.0

35 / 23.9

67.4

67.4

55.0

55.0

39.9

39.9

32.9

32.9

37 / 21.4

73.5

73.5

61.0

61.0

45.5

45.5

38.4

38.4

33 / 26.7

66.2

66.2

52.9

52.9

36.8

36.8

29.2

29.2

35 / 23.9

73.1

73.1

59.6

59.6

43.2

43.2

35.6

35.6

37 / 21.4

79.8

79.8

66.1

66.1

49.3

49.3

41.6

41.6

33 / 26.7

73.8

73.8

59.0

59.0

41.1

41.1

32.7

32.7

35 / 23.9

81.5

81.5

66.5

66.5

48.2

48.2

39.7

39.7

37 / 21.4

88.8

88.8

73.7

73.7

55.0

55.0

46.4

46.4

33 / 26.7

84.9

84.9

67.9

67.9

47.1

47.1

37.4

37.4

35 / 23.9

93.8

93.8

76.5

76.5

55.3

55.3

45.6

45.6

37 / 21.4

102.4

102.4

84.8

84.8

63.2

63.2

53.3

53.3

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

C0C0

SR18D060-C0C0-0

18 / 24 C

SR

SR15D040-C0C0-0

15 / 20 C

Technical

SR12D030-C0C0-0

12 / 17 C

107

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR09D020-C0C0

Mechanical Data
SR09D020-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

108

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR09D020-C0C0-2

25.3
0.81

25.3
25.3
0.81
0.81
963 x 890 x 1980
320 / 351
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
16
16
16
1.2
1.2
1.2
18.7
18.7
18.7
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 1.96
1 x 1.96
1 x 1.96
1178 / 1560
1178 / 1560
1178 / 1560
459
459
459
1.85
1.85
1.85

mm
mm

35
22

kW

9
7.5

kg/hr
l/m

SR09D020-C0C0-1

3
7

35
22
Disposable to BS EN 779-G4
9
6.8

35
22
9
7.5

3
3
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
1 x 3.6
1524 / 2260
1006

4
1.7

(4) kW
rpm
Pa

1 x 3.6
1524 / 2260
1006

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

1 x 3.6
1523 / 2260
1014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR09D020-C0C0

Electrical Data
Unit Data - Full Function

SR09D020-C0C0-0

SR09D020-C0C0-1

SR09D020-C0C0-2

(1)

Nominal Run Amps

21

20.6

38.7

Recommended Mains Fuse Size

25

25

50
7.9

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 1.96

1 x 1.96

1 x 1.96

5.9

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

7.5

6.8

7.5

Current Per Phase

10.9

10.3

19.7

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

2.25

2.25

2.25

Full Load Amps

3.3

3.5

1 x 3.6

1 x 3.6

1 x 3.6

5.8

5.8

11

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

109

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR09D025-C0C0

Mechanical Data
SR09D025-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

110

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR09D025-C0C0-2

30.5
1.47

30.5
30.5
1.47
1.47
963 x 890 x 1980
320 / 351
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
16
16
16
1.45
1.45
1.45
26.6
26.6
26.6
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 1.96
1 x 1.96
1 x 1.96
1444 / 1560
1444 / 1560
1444 / 1560
197
197
197
2.30
2.30
2.30

mm
mm

35
22

kW

9
7.5

kg/hr
l/m

SR09D025-C0C0-1

3
7

35
22
Disposable to BS EN 779-G4
9
6.8

35
22
9
7.5

3
3
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
1 x 3.6
1866 / 2260
673

4
1.7

(4) kW
rpm
Pa

1 x 3.6
1866 / 2260
673

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

1 x 3.6
1936 / 2260
543

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR09D025-C0C0

Electrical Data
Unit Data - Full Function

SR09D025-C0C0-0

SR09D025-C0C0-1

SR09D025-C0C0-2

(1)

Nominal Run Amps

21

20.6

38.7

Recommended Mains Fuse Size

25

25

50
7.9

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

10

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 1.96

1 x 1.96

1 x 1.96

5.9

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

7.5

6.8

7.5

Current Per Phase

10.9

10.3

19.7

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

2.25

2.25

2.25

Full Load Amps

3.3

3.5

1 x 3.6

1 x 3.6

1 x 3.6

5.8

5.8

11

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
C000
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

111

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR12D030-C0C0

Mechanical Data
SR12D030-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

112

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR12D030-C0C0-2

36.5
1.26

36.5
36.5
1.26
1.26
1242 x 890 x 1980
380 / 424
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
22
22
22
1.74
1.74
1.74
21.5
21.5
21.5
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.9
1 x 2.9
1 x 2.9
1316 / 1660
1316 / 1660
1316 / 1660
504
504
504
2.70
2.70
2.70

mm
mm

42
22

kW

12
7.5

kg/hr
l/m

SR12D030-C0C0-1

3
7

42
22
Disposable to BS EN 779-G4
12
6.8

42
22
12
7.5

3
3
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR12D030-C0C0

Electrical Data
Unit Data - Full Function

SR12D030-C0C0-0

SR12D030-C0C0-1

SR12D030-C0C0-2

(1)

Nominal Run Amps

19.6

19.2

35.2

Recommended Mains Fuse Size

25

25

50

Nominal Run Amps

5.43

5.43

9.5

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 2.9

1 x 2.9

1 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

7.5

6.8

7.5

Current Per Phase

10.9

10.3

19.7

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

2.25

2.25

2.25

Full Load Amps

3.3

3.5

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

113

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR12D035-C0C0

Mechanical Data
SR12D035-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

114

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR12D035-C0C0-2

43.1
2.36

43.1
43.1
2.36
2.36
1242 x 890 x 1980
380 / 424
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
22
22
22
2.05
2.05
2.05
29
29
29.0
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
1 x 2.9
1 x 2.9
1 x 2.9
1595 / 1660
1595 / 1660
1595 / 1660
124
124
124
3.30
3.30
3.30

mm
mm

42
22

kW

12
7.5

kg/hr
l/m

SR12D035-C0C0-1

3
7

42
22
Disposable to BS EN 779-G4
12
6.8

42
22
12
7.5

3
3
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR12D035-C0C0

Electrical Data
Unit Data - Full Function

SR12D035-C0C0-0

SR12D035-C0C0-1

SR12D035-C0C0-2

(1)

Nominal Run Amps

19.6

19.2

35.2

Recommended Mains Fuse Size

25

25

50

Unit Data - Cooling Only


Nominal Run Amps

5.43

5.43

9.5

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

16

16

35

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

1 x 2.9

1 x 2.9

1 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

7.5

6.8

7.5

Current Per Phase

10.9

10.3

19.7

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

2.25

2.25

2.25

Full Load Amps

3.3

3.5

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

115

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR15D040-C0C0

Mechanical Data
SR15D040-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

116

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR15D040-C0C0-2

50.5
2.15

50.5
50.5
2.15
2.15
1521 x 890 x 1980
464 / 518
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
27
27
27
2.4
2.4
2.4
30.5
30.5
30.5
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 1.96
2 x 1.96
2 x 1.96
1281 / 1560
1281 / 1560
1281 / 1560
349
349
349
3.80
3.80
3.80

mm
mm

42
22

kW

15
15.0

kg/hr
l/m

SR15D040-C0C0-1

8
7

42
22
Disposable to BS EN 779-G4
15
13.5

42
22
15
15.0

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
2 x 3.6
1636 / 2260
898

4
1.7

(4) kW
rpm
Pa

2 x 3.6
1636 / 2260
898

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

2 x 3.6
1705 / 2260
849

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR15D040-C0C0

Electrical Data
Unit Data - Full Function

SR15D040-C0C0-0

SR15D040-C0C0-1

SR15D040-C0C0-2

(1)

Nominal Run Amps

43

42.4

79.2

Recommended Mains Fuse Size

50

50

100
13.8

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 1.96

2 x 1.96

2 x 1.96

5.9

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

2 x 3.6

2 x 3.6

2 x 3.6

5.8

5.8

11

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

117

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR15D045-C0C0

Mechanical Data
SR15D045-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

118

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR15D045-C0C0-2

54.7
2.82

54.7
54.7
2.82
2.82
1521 x 890 x 1980
464 / 518
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
27
27
27
2.60
2.60
2.60
35.3
35.3
35.3
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 1.96
2 x 1.96
2 x 1.96
1404 / 1560
1404 / 1560
1404 / 1560
221
221
221
4.20
4.20
4.20

mm
mm

42
22

kW

15
15.0

kg/hr
l/m

SR15D045-C0C0-1

8
7

42
22
Disposable to BS EN 779-G4
15
13.5

42
22
15
15.0

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection
Backwards Curved, Centrifugal Direct Drive
2 x 3.6
1796 / 2260
747

4
1.7

(4) kW
rpm
Pa

2 x 3.6
1796 / 2260
747

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

2 x 3.6
1869 / 2260
655

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR15D045-C0C0

Electrical Data
Unit Data - Full Function

SR15D045-C0C0-0

SR15D045-C0C0-1

SR15D045-C0C0-2

(1)

Nominal Run Amps

43

42.4

79.2

Recommended Mains Fuse Size

50

50

100
13.8

Unit Data - Cooling Only


Nominal Run Amps

Recommended Mains Fuse Size

10

10

16

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 1.96

2 x 1.96

2 x 1.96

5.9

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

Quantity x Motor Size

Humidifier
kg/hr

kW

Full Load Amps

8.7

9.2

15.8

2 x 3.6

2 x 3.6

2 x 3.6

5.8

5.8

11

SR

Capacity
Rating
First upgrade EC Motor - Per Fan
Quantity x Motor Size

kW

Full Load Amps

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

119

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR18D050-C0C0

Mechanical Data
SR18D050-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

120

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR18D050-C0C0-2

61.0
2.25

61.0
61.0
2.25
2.25
1800 x 890 x 1980
540 / 609
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
35
35
35
2.9
2.9
2.9
26.2
26.2
26.2
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1231 / 1660
1231 / 1660
1231 / 1660
551
551
551
4.60
4.60
4.60

mm
mm

54
22

kW

18
15.0

kg/hr
l/m

SR18D050-C0C0-1

8
7

54
22
Disposable to BS EN 779-G4
18
13.5

54
22
18
15.0

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR18D050-C0C0

Electrical Data
Unit Data - Full Function

SR18D050-C0C0-0

SR18D050-C0C0-1

SR18D050-C0C0-2

(1)

Nominal Run Amps

40.3

39.7

72.2

Recommended Mains Fuse Size

50

50

100

Nominal Run Amps

9.86

9.86

17

Recommended Mains Fuse Size

16

16

20

Unit Data - Cooling Only

Max Mains Incoming Cable Size

mm

Mains Supply

35

35

70

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

121

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

SR18D060-C0C0

Mechanical Data
SR18D060-C0C0-0
Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine / Operating
Construction

(1) kW
(2) kW
mm
(3) kg

C0C0

SR

Technical

Material / Colour

122

Cooling Coil
Cooling / Dehum Stages
Water volume
Water flow rate
Pressure drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain pump flow rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SR18D060-C0C0-2

70.1
3.86

70.1
70.1
3.86
3.86
1800 x 890 x 1980
540 / 609
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)
Frame: Anodised Aluminium Frame with Aluminium Corners, Epoxy
Baked Powder Coated Paint - Black Grey (RAL 7021)
Copper Tube / Hydrophilic Coated Aluminium Fins
1 (Modulated) / 1
35
35
35
3.34
3.34
3.34
33.1
33.1
33.1
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1460 / 1660
1460 / 1660
1460 / 1660
318
318
318
5.50
5.50
5.50

mm
mm

54
22

kW

18
15.0

kg/hr
l/m

SR18D060-C0C0-1

8
7

54
22
Disposable to BS EN 779-G4
18
13.5

54
22
18
15.0

8
8
7
7
3/4 BSPF Braided Flexible Hose / 19mm Hose Connection

m
l/m

5
10.8

5
10.8
10mm Stainless Steel Stub Connection

5
10.8

m
l/m

4
1.7

4
1.7
10mm Quarter Turn Plastic Barb Connection

4
1.7

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C /45% RH water 7C/ 12C.


(2) Fan Gain / Fan power input based upon fan operating with design airflow at 25Pa ESP, these values may change with different ESP.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units

SR18D060-C0C0

Electrical Data
Unit Data - Full Function

SR18D060-C0C0-0

SR18D060-C0C0-1

SR18D060-C0C0-2

(1)

Nominal Run Amps

40.3

39.7

72.2

Recommended Mains Fuse Size

50

50

100

Nominal Run Amps

9.86

9.86

17

Recommended Mains Fuse Size

16

16

20

Unit Data - Cooling Only

Max Mains Incoming Cable Size

mm

Mains Supply

35

35

70

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4
8

Technical

Quantity x Motor Size

Humidifier
kg/hr

Rating

kW

Full Load Amps

8.7

9.2

15.8

SR

Capacity

First upgrade EC Motor - Per Fan


Quantity x Motor Size

kW

N/A

N/A

N/A

Full Load Amps

N/A

N/A

N/A

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

123

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units


Waterside Pressure Drop Data

90.0

80.0
70.0

10
11

Pressure Drop (kPa)

Technical

60.0
50.0
40.0
30.0
20.0
10.0
0.0
1.00

2.00

3.00
Flow Rate (l/s)

4.00

5.00

6.00

SR

0.00

C0C0

8
9
10
11

SR09D020 - C0C0 / SR09D025 - C0C0


SR12D030 - C0C0 / SR12D035 - C0C0
SR15D040 - C0C0 / SR15D045 - C0C0
SR18D050 - C0C0 / SR 18D060 - C0C0

Includes coil, 2 or 3 port valve and pipework.


To calculate 3 port valve pressure drop:
Q

M

P valve =

where P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

SR09 C0C0

124

Valve Kv

16.0

0.44

SR12 C0C0

25.0

0.69

SR15 C0C0

25.0

0.69

SR18 C0C0

40.0

1.11

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SR C0C0 Units


Sound Data

Sound Measurement
Discharge Air
SR09D020-C0C0

SR09D025-C0C0

SR12D035-C0C0

SR15D045-C0C0

SR18D050-C0C0

250

500

1000

2000

4000

8000

74

73

71

72

73

71

65

56

26

Return Air

73

73

71

71

72

69

64

55

25

Case Breakout

75

77

77

74

72

71

64

56

29

Sound Pressure @ 3m

60

62

62

60

58

56

50

42

14

Discharge Air

80

78

77

78

78

76

70

61

31

Return Air

79

78

77

76

77

74

69

60

31

Case Breakout

80

82

82

80

78

76

70

62

34

Sound Pressure @ 3m

66

67

67

65

63

62

55

47

20

Discharge Air

77

73

76

75

74

73

67

61

37

Return Air

75

73

76

73

73

71

66

60

36

Case Breakout

77

76

81

77

74

73

66

61

40

Sound Pressure @ 3m

62

62

67

62

59

59

52

47

26

Discharge Air

82

78

81

81

79

79

73

67

43

Return Air

81

78

81

79

78

77

72

66

42

Case Breakout

82

82

87

82

79

79

72

67

46

Sound Pressure @ 3m

68

68

72

68

64

64

58

53

31

Discharge Air

80

78

76

78

78

76

70

61

31

Return Air

78

78

76

76

77

74

69

60

30

Case Breakout

80

82

82

79

77

76

70

61

34

Sound Pressure @ 3m

65

67

67

65

63

61

55

47

20

Discharge Air

82

80

79

80

80

78

72

63

34

Return Air

81

80

79

78

79

77

72

63

33

Case Breakout

82

84

84

82

80

78

72

64

37

Sound Pressure @ 3m

68

70

70

67

65

64

58

49

22

Discharge Air

78

74

77

76

76

74

68

62

38

Return Air

76

74

77

75

74

72

67

61

38

Case Breakout

78

78

82

78

75

74

68

63

41

Sound Pressure @ 3m

64

63

68

64

60

60

53

48

27

Discharge Air

82

79

82

81

80

79

73

67

43

Return Air

81

79

82

79

79

77

72

66

42

Case Breakout

83

82

87

83

79

79

72

67

46

Sound Pressure @ 3m

68

68

72

68

65

64

58

53

32

C0C0

SR18D060-C0C0

125

SR

SR15D040-C0C0

63

Technical

SR12D030-C0C0

Frequency (Hz) dB

Overall
dB(A)

(1) dB(A) is the overall sound level, measured on the A scale


(2) All sound data measured at nominal conditions, Discharge Air, Return air and case breakout is sound power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

125

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SR C0C0 Units

C0C0

SR

Technical

Interconnecting Wiring

N1

Neutral (Supply 1)

301

L1 (Supply 1)

302

L2 (Supply 1)

303

L3 (Supply 1)

N2

Neutral (Supply 2)

304

L1 (Supply 2)

305

L2 (Supply 2)

306

L3 (Supply 2)

PE

Protective Earth

502

Fire Detector

583

Fire Detector

583

Smoke Detector

584

Smoke Detector

502

Remote On/Off

522

Remote On/Off

Condensate Pump Supply (230V)

N (3*)

Condensate Pump Supply (230V)

534

Condensate Pump High Level Alarm

535

Condensate Pump High Level Alarm

609

Flood Detection Tape / Probe

610

Flood Detection Tape / Probe

810

Supply Air Temperature Sensor

811

Supply Air Temperature Sensor

560

Non-Critical Alarm N/O

561

Non-Critical Alarm Common

563

Critical Alarm N/O

564

Critical Alarm Common

565

Critical Alarm N/C

881

BMS Connection

882

BMS Connection

883

BMS Connection

CONN17

WIRE

1
2
3
4

502
583 or 584
2
N or 3

PIN 1

Conn 17
CONN14

Conn 14

PIN No.

WIRE

1
2
3
4
5
6
7

502
522
560
561
563
564
565

PIN 1

Conn 16

CONN16

PIN No.

WIRE

1
2
3
4
5
6
7
8

2
N or 3
534
535
609
610
810
811

PIN 1

Conn 14

CONN15

Conn 15

*For 220V/3PH NO neutral units the Neutral connection is replaced with a live phase.

126

PIN No.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

PIN 1

PIN No.

WIRE

1
2
3

881
882
883

Precision Air Conditioning

SmartCool 6 - 200kW

Intentionally Blank

Technical
SR
C0C0
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

127

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CH00 Units


Performance Data SD CH00
Chilled water inlet and outlet temperatures
Air On

SD18D110-CH00-0

Technical

SD22D140-CH00-0

SD25D175-CH00-0

SD35D255-CH00-0

7 / 12 C

8 / 14 C

128

10 / 16 C

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

22 / 50

117.0

93.8

89.6

81.5

68.6

68.6

54.0

54.0

24 / 45

132.4

106.7

105.3

94.6

82.9

82.9

69.2

69.2

26 / 40

145.4

119.6

118.6

107.7

96.5

96.5

83.2

83.2

22 / 50

145.9

113.5

114.2

99.0

85.6

85.6

69.0

69.0

24 / 45

163.8

128.6

132.4

114.3

104.9

98.8

86.0

86.0

26 / 40

179.2

143.8

147.9

129.6

120.8

113.8

102.1

102.1

22 / 50

192.3

149.1

151.4

130.3

116.7

111.2

92.2

92.2

24 / 45

215.4

168.9

174.7

150.2

139.3

128.9

113.9

113.9

26 / 40

235.3

188.6

194.8

170.1

159.8

148.6

134.6

134.6

22 / 50

239.9

190.2

185.8

165.7

141.5

141.5

113.2

113.2

24 / 45

270.2

216.0

216.5

191.9

169.3

169.3

142.2

142.2

26 / 40

296.1

241.8

242.9

217.9

196.1

196.1

169.8

169.8

22 / 50

281.6

220.7

220.2

192.6

166.2

166.2

134.2

134.2

24 / 45

316.2

250.3

255.2

222.5

202.8

193.8

167.0

167.0

26 / 40

346.0

279.8

285.2

252.2

233.6

223.4

198.1

198.1

CH00

SD

SD31D215-CH00-0

5 / 10 C

Temp. (C)

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units


Performance Data SD CH00
Chilled water inlet and outlet temperatures
Model

SD18D110-CH00-0

SD22D140-CH00-0

SD31D215-CH00-0

17 / 22 C

18 / 24C

20 / 26 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

33 / 26

99.5

99.5

86.8

86.8

76.6

76.6

63.3

63.3

35 / 24

111.3

111.3

98.9

98.9

89.2

89.2

76.3

76.3

37 / 22

123.1

123.1

110.8

110.8

101.5

101.5

88.9

88.9

33 / 26

119.8

119.8

104.8

104.8

93.6

93.6

77.9

77.9

35 / 24

133.6

133.6

118.9

118.9

108.1

108.1

93.0

93.0

37 / 22

147.4

147.4

132.9

132.9

122.5

122.5

107.7

107.7

33 / 26

157.2

157.2

137.5

137.5

123.1

123.1

102.8

102.8

35 / 24

175.1

175.1

155.8

155.8

142.0

142.0

122.3

122.3

37 / 22

193.1

193.1

174.1

174.1

160.6

160.6

141.4

141.4

33 / 26

200.8

200.8

175.5

175.5

155.8

155.8

129.3

129.3

35 / 24

224.4

224.4

199.4

199.4

180.6

180.6

155.0

155.0

37 / 22

247.9

247.9

223.2

223.2

205.1

205.1

179.9

179.9

33 / 26

232.6

232.6

203.5

203.5

181.5

181.5

151.1

151.1

35 / 24

259.3

259.3

230.8

230.8

209.6

209.6

180.4

180.4

37 / 22

286.3

286.3

258.1

258.1

237.6

237.6

208.9

208.9

SD

SD35D255-CH00-0

15 / 20 C

Technical

SD25D175-CH00-0

Air On

CH00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

129

SmartCool 6 - 200kW
Technical Data SD CH00 Units

Precision Air Conditioning


SD18D110-CH00

Mechanical Data

CH00

SD

Technical

SD18D110-CH00-0

130

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD18D110-CH00-2

105.3
105.3
105.3
2.6
2.6
2.6
1800 x 890 x 1980
1800 x 890 x 1980
1800 x 890 x 1980
463 / 175 / 699
463 / 175 / 699
463 / 175 / 699
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
62
62
62
5.0
5.0
5.0
35.7
35.7
35.7
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1334 / 1657
1334 / 1657
1334 / 1657
485
485
485
5.7
5.7
5.7

mm
mm

54
22

kW

6
15.0

kg/hr
l/m

SD18D110-CH00-1

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

8
8
8
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C.


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units

SD18D110-CH00

Electrical Data
Unit Data - Full Function

SD18D110-CH00-0

SD18D110-CH00-1

SD18D110-CH00-2

(1)

Nominal Run Amps

40.3

39.7

72.2

Recommended Mains Fuse Size

50

50

100
17.0

Unit Data - Cooling Only


Nominal Run Amps

9.9

9.9

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

EC

EC

EC

kW

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2)

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

Quantity x Motor Size

Humidifier
kg/hr

kW

6.0

6.0

6.0

Full Load Amps

8.7

9.2

15.8

SD

Capacity
Rating

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CH00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

131

SmartCool 6 - 200kW
Technical Data SD CH00 Units

Precision Air Conditioning


SD22D140-CH00

Mechanical Data

CH00

SD

Technical

SD22D140-CH00-0

132

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD22D140-CH00-1

SD22D140-CH00-2

132.4
132.4
132.4
3.5
3.5
3.5
2200 x 890 x 1980
2200 x 890 x 1980
2200 x 890 x 1980
525 / 189 / 787
525 / 189 / 787
525 / 189 / 787
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
73
73
73
6.3
6.3
6.3
55.6
55.6
55.6
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1503 / 1657
1503 / 1657
1503 / 1657
266
266
266
6.7
6.7
6.7

mm
mm

54
22

kW

6
15.0

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C.


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units

SD22D140-CH00

Electrical Data
Unit Data - Full Function

SD22D140-CH00-0

SD22D140-CH00-1

SD22D140-CH00-2

(1)

Nominal Run Amps

64.2

64.7

115.6

Recommended Mains Fuse Size

80

80

160
17.0

Unit Data - Cooling Only


Nominal Run Amps

9.9

9.9

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

70

70

70

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

24

24

24

Mains Supply

Control Circuit

VAC

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity
Rating

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CH00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

133

SmartCool 6 - 200kW
Technical Data SD CH00 Units

Precision Air Conditioning


SD25D175-CH00

Mechanical Data

CH00

SD

Technical

SD25D175-CH00-0

134

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD25D175-CH00-1

SD25D175-CH00-2

174.7
174.7
174.7
4.7
4.7
4.7
2500 x 890 x 1980
2500 x 890 x 1980
2500 x 890 x 1980
588 / 244 / 919
588 / 244 / 919
588 / 244 / 919
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
88
88
88
8.3
8.3
8.3
77.2
77.2
77.2
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
3 x 2.9
3 x 2.9
3 x 2.9
1409 / 1657
1409 / 1657
1409 / 1657
392
392
392
8.8
8.8
8.8

mm
mm

67
22

kW

6
22.5

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
20.3

67
22
6
22.5

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C.


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units

SD25D175-CH00

Electrical Data
Unit Data - Full Function

SD25D175-CH00-0

SD25D175-CH00-1

SD25D175-CH00-2

(1)

Nominal Run Amps

79.4

79.4

142.8

Recommended Mains Fuse Size

100

100

200

Nominal Run Amps

14.3

14.3

24.5

Recommended Mains Fuse Size

20

20

32

Max Mains Incoming Cable Size

mm

70

70

185

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

24

24

24

Unit Data - Cooling Only

Mains Supply

Control Circuit

VAC

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

3 x 2.9

3 x 2.9

3 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

22.5

20.3

22.5

Current Per Phase

32.5

30.9

59.1

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CH00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

135

SmartCool 6 - 200kW
Technical Data SD CH00 Units

Precision Air Conditioning


SD31D215-CH00

Mechanical Data

CH00

SD

Technical

SD31D215-CH00-0

136

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD31D215-CH00-1

SD31D215-CH00-2

216.5
216.5
216.5
5.9
5.9
5.9
3100 x 890 x 1980
3100 x 890 x 1980
3100 x 890 x 1980
690 / 305 / 1101
690 / 305 / 1101
690 / 305 / 1101
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
107
107
107
10.3
10.3
10.3
76.3
76.3
76.3
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1374 / 1657
1374 / 1657
1374 / 1657
428
428
428
11.3
11.3
11.3

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C.


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units

SD31D215-CH00

Electrical Data
Unit Data - Full Function

SD31D215-CH00-0

SD31D215-CH00-1

SD31D215-CH00-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CH00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

137

SmartCool 6 - 200kW
Technical Data SD CH00 Units

Precision Air Conditioning


SD35D255-CH00

Mechanical Data

CH00

SD

Technical

SD35D255-CH00-0

138

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD35D255-CH00-1

SD35D255-CH00-2

255.2
255.2
255.2
7.8
7.8
7.8
3500 x 890 x 1980
3500 x 890 x 1980
3500 x 890 x 1980
745 / 326 / 1190
745 / 326 / 1190
745 / 326 / 1190
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
120
120
120
12.1
12.1
12.1
106.5
106.5
106.5
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1532 / 1657
1532 / 1657
1532 / 1657
225
225
225
13.0
13.0
13.0

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C.


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units

SD35D255-CH00

Electrical Data
Unit Data - Full Function

SD35D255-CH00-0

SD35D255-CH00-1

SD35D255-CH00-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

24

24

24

Unit Data - Cooling Only

Mains Supply

Control Circuit

VAC

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CH00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

139

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CH00 Units


Waterside Pressure Drop Data

200.0
180.0
160.0

Technical

Pressure Drop (kPa)

140.0

1 and 2

120.0

100.0
80.0
60.0
40.0

SD

20.0
0.0
0.00

2.00

4.00

SD18D110-CH00-0

1
2
3

6.00
Flow Rate (l/s)
SD22D140-CH00-0

8.00

SD25D175-CH00-0

SD18D110 - CH00 - 0
SD22D140 - CH00 - 0
SD25D175 - CH00 - 0

CH00

Includes coil, 2 port valve and pipework.


To calculate 3 port valve pressure drop:
P valve =

Q

M

where P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

140

Kv Cooling

Kv Bypass

SD18D110-CH00

40

40

SD22D140-CH00

63

40

SD25D175-CH00

63

40

10.00

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

12.00

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units


Waterside Pressure Drop Data

180.0
160.0
140.0

4
5

100.0

Technical

Pressure Drop (kPa)

120.0

80.0
60.0
40.0
20.0

SD

0.0
0.00

2.00

4.00

6.00

8.00

10.00

12.00

14.00

16.00

Flow Rate (l/s)


SD31D215-CH00-0
SD35D225-CH00-0

4
5

SD31D215 - CH00 - 0
SD35D225 - CH00 - 0

Includes coil, port valve and pipework.

P valve =

Q

M

CH00

To calculate 3 port valve pressure drop:

where P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

Kv Cooling

Kv Bypass

SD31D215-CH00

63

63

SD35D255-CH00

63

63

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

141

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CH00 Units


Sound Data

SD18D110-CH00-0

SD

Technical

SD22D140-CH00-0

SD25D175-CH00-0

SD31D215-CH00-0

SD35D225-CH00-0

Frequency (Hz) dB

Overall
dB(A)

63

125

250

500

1000

2000

4000

8000

Discharge Air

63.0

66.1

77.1

63.9

56.1

49.9

47.3

39.9

32.2

Return Air

58.3

64.3

71.3

59.2

52.7

46.8

47.1

39.6

32.1

Case Breakout

64.3

71.6

76.3

66.7

60.4

54.0

50.5

46.5

37.9

Sound Pressure @ 3m

49.8

57.1

61.8

52.1

45.8

39.4

36.0

31.9

23.3

Sound Measurement

Discharge Air

66.0

69.2

80.1

66.9

58.9

53.1

50.7

43.4

35.6

Return Air

61.3

67.5

74.4

62.2

55.5

49.9

50.5

43.1

35.4

Case Breakout

67.3

74.8

79.4

69.7

63.2

57.2

53.9

50.0

41.2

Sound Pressure @ 3m

52.8

60.2

64.8

55.1

48.6

42.6

39.4

35.4

26.6

Discharge Air

66.0

69.2

80.1

66.9

59.1

53.0

50.5

43.1

35.4

Return Air

61.3

67.4

74.4

62.3

55.7

49.9

50.3

42.8

35.2

Case Breakout

67.4

74.7

79.4

69.7

63.4

57.1

53.7

49.7

41.0

Sound Pressure @ 3m

52.8

60.2

64.9

55.2

48.8

42.5

39.2

35.1

26.5

Discharge Air

66.7

69.8

80.8

67.6

59.8

53.6

51.1

43.7

36.0

Return Air

62.0

68.0

75.0

62.9

56.3

50.5

50.9

43.4

35.8

Case Breakout

68.0

75.3

80.0

70.4

64.0

57.7

54.3

50.2

41.6

Sound Pressure @ 3m

53.5

60.8

65.5

55.8

49.5

43.2

39.7

35.7

27.0

Discharge Air

69.6

72.8

83.7

70.4

62.4

56.7

54.4

47.1

39.2

Return Air

64.9

71.1

77.9

65.8

59.0

53.6

54.2

46.8

39.1

Case Breakout

70.9

78.4

82.9

73.2

66.7

60.8

57.6

53.7

44.8

Sound Pressure @ 3m

56.4

63.8

68.4

58.7

52.1

46.3

43.1

39.1

30.3

CH00

(1) dB(A) is the overall sound level, measured on the A scale


(2) All sound data measured at nominal conditions, Discharge Air, Return air and case breakout is sound power.

142

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CH00 Units


Interconnecting Wiring
Neutral (Supply 1)

L1 (Supply 1)

302

L2 (Supply 1)

303

L3 (Supply 1)

N2

Neutral (Supply 2)

304

L1 (Supply 2)

305

L2 (Supply 2)

306

L3 (Supply 2)

PE

Protective Earth

502

Fire Detector

583

Fire Detector

583

Smoke Detector

584

Smoke Detector

502

Remote On/Off

522

Remote On/Off

Condensate Pump Supply (230V)

N (3*)

Condensate Pump Supply (230V)

534

Condensate Pump High Level Alarm

535

Condensate Pump High Level Alarm

609

Flood Detection Tape / Probe

610

Flood Detection Tape / Probe

810

Supply Air Temperature Sensor

811

Supply Air Temperature Sensor

560

Non-Critical Alarm N/O

561

Non-Critical Alarm Common

563

Critical Alarm N/O

564

Critical Alarm Common

565

Critical Alarm N/C

881

BMS Connection

882

BMS Connection

883

BMS Connection

CH00

SD

301

Technical

N1

*For 220V/3PH NO neutral units the Neutral connection is replaced with a live phase.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

143

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CL00 Units


Performance Data SD CL00
Chilled water inlet and outlet temperatures
Air On

SD18D115-CL00-0

Technical

SD22D145-CL00-0

SD25D180-CL00-0

SD

SD31D235-CL00-0

7 / 12 C

8 / 14 C

144

10 / 16 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

22 / 50

124.1

96.5

97.5

84.2

74.8

72.3

59.3

59.3

24 / 45

139.2

109.3

112.7

97.2

89.7

83.7

73.4

73.4

26 / 40

152.1

122.1

125.8

110.1

103.0

96.4

86.9

86.9

22 / 50

152.0

115.9

120.9

101.3

97.2

90.4

73.0

73.0

24 / 45

169.8

130.9

138.7

116.5

115.7

106.1

89.4

89.4

26 / 40

184.9

145.9

154.1

131.6

131.5

121.5

105.2

105.2

22 / 50

199.1

151.8

158.7

132.8

128.6

118.8

96.2

96.2

24 / 45

222.1

171.4

181.8

152.7

152.4

139.2

117.5

117.5

26 / 40

241.9

191.1

201.7

172.5

172.9

159.4

137.9

137.9

22 / 50

256.3

196.6

203.8

171.9

164.0

153.5

123.8

123.8

24 / 45

286.3

222.1

233.9

197.7

195.1

180.0

151.4

151.4

26 / 40

312.1

247.7

259.8

223.5

221.7

206.3

177.9

177.9

22 / 50

297.7

227.0

237.7

198.7

193.2

177.9

144.1

144.1

24 / 45

332.2

256.4

272.1

228.3

228.7

208.3

175.7

175.7

26 / 40

361.6

285.6

301.7

257.8

259.0

238.4

206.1

206.1

CL00

SD35D270-CL00-0

5 / 10 C

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units


Performance Data SD CL00
Chilled water inlet and outlet temperatures
Model

SD18D115-CL00-0

SD22D145-CL00-0

SD31D235-CL00-0

17 / 22 C

18 / 24C

20 / 26 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

33 / 26

101.7

101.7

89.0

89.0

79.6

79.6

66.4

66.4

35 / 24

113.3

113.3

100.8

100.8

91.8

91.8

79.0

79.0

37 / 22

125.0

125.0

112.7

112.7

103.9

103.9

91.5

91.5

33 / 26

121.7

121.7

106.8

106.8

96.1

96.1

80.6

80.6

35 / 24

135.4

135.4

120.6

120.6

110.4

110.4

95.4

95.4

37 / 22

149.1

149.1

134.5

134.5

124.6

124.6

109.8

109.8

33 / 26

159.2

159.2

139.7

139.7

125.9

125.9

105.7

105.7

35 / 24

177.1

177.1

157.8

157.8

144.6

144.6

124.9

124.9

37 / 22

195.1

195.1

176.1

176.1

163.1

163.1

143.8

143.8

33 / 26

206.1

206.1

180.7

180.7

162.6

162.6

136.4

136.4

35 / 24

229.2

229.2

204.2

204.2

186.8

186.8

161.4

161.4

37 / 22

252.6

252.6

227.9

227.9

210.9

210.9

185.8

185.8

33 / 26

237.6

237.6

208.5

208.5

188.1

188.1

158.0

158.0

35 / 24

264.3

264.3

235.6

235.6

215.9

215.9

186.6

186.6

37 / 22

291.2

291.2

262.8

262.8

243.5

243.5

214.8

214.8

SD

SD35D270-CL00-0

15 / 20 C

Technical

SD25D180-CL00-0

Air On

CL00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

145

SmartCool 6 - 200kW
Technical Data SD CL00 Units

Precision Air Conditioning


SD18D115-CL00

Mechanical Data

CL00

SD

Technical

SD18D115-CL00-0

146

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD18D115-CL00-2

91.6
91.6
91.6
2.6
2.6
2.6
1800 x 890 x 1980
1800 x 890 x 1980
1800 x 890 x 1980
463 / 175 / 699
463 / 175 / 699
463 / 175 / 699
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
62
62
62
3.6
3.6
3.6
25.9
25.9
25.9
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1334 / 1657
1334 / 1657
1334 / 1657
485
485
485
5.7
5.7
5.7

mm
mm

54
22

kW

6
15.0

kg/hr
l/m

SD18D115-CL00-1

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

8
8
8
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power. All other options quote shaft power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units

SD18D115-CL00

Electrical Data
Unit Data - Full Function

SD18D115-CL00-0

SD18D115-CL00-1

SD18D115-CL00-2

(1)

Nominal Run Amps

40.3

39.7

72.2

Recommended Mains Fuse Size

50

50

100

Nominal Run Amps

9.9

9.9

17.0

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type

EC

EC

2 x 2.9

2 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Full Load Amps

(2) kW
A

OPTIONAL EXTRAS
Electric Heating

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

EC
2 x 2.9

Quantity x Motor Size

Humidifier
kg/hr

kW

6.0

6.0

6.0

Full Load Amps

8.7

9.2

15.8

SD

Capacity
Rating

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CL00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

147

SmartCool 6 - 200kW
Technical Data SD CL00 Units

Precision Air Conditioning


SD22D145-CL00

Mechanical Data

CL00

SD

Technical

SD22D145-CL00-0

148

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD22D145-CL00-1

SD22D145-CL00-2

110.2
110.2
110.2
3.5
3.5
3.5
2200 x 890 x 1980
2200 x 890 x 1980
2200 x 890 x 1980
525 / 189 / 787
525 / 189 / 787
525 / 189 / 787
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
73
73
73
4.4
4.4
4.4
39.5
39.5
39.5
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1503 / 1657
1503 / 1657
1503 / 1657
266
266
266
6.7
6.7
6.7

mm
mm

54
22

kW

6
15.0

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power. All other options quote shaft power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units

SD22D145-CL00

Electrical Data
Unit Data - Full Function

SD22D145-CL00-0

SD22D145-CL00-1

SD22D145-CL00-2

(1)

Nominal Run Amps

64.2

64.7

115.6

Recommended Mains Fuse Size

80

80

160

Nominal Run Amps

9.9

9.9

17.0

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

70

70

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CL00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

149

SmartCool 6 - 200kW
Technical Data SD CL00 Units

Precision Air Conditioning


SD25D180-CL00

Mechanical Data

CL00

SD

Technical

SD25D180-CL00-0

150

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD25D180-CL00-1

SD25D180-CL00-2

144.3
144.3
144.3
4.7
4.7
4.7
2500 x 890 x 1980
2500 x 890 x 1980
2500 x 890 x 1980
588 / 244 / 919
588 / 244 / 919
588 / 244 / 919
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
88
88
88
5.7
5.7
5.7
62.4
62.4
62.4
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
3 x 2.9
3 x 2.9
3 x 2.9
1409 / 1657
1409 / 1657
1409 / 1657
392
392
392
8.8
8.8
8.8

mm
mm

67
22

kW

6
22.5

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
20.3

67
22
6
22.5

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power. All other options quote shaft power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units

SD25D180-CL00

Electrical Data
Unit Data - Full Function

SD25D180-CL00-0

SD25D180-CL00-1

SD25D180-CL00-2

(1)

Nominal Run Amps

79.4

79.4

142.8

Recommended Mains Fuse Size

100

100

200

Nominal Run Amps

14.3

14.3

24.5

Recommended Mains Fuse Size

20

20

32

Max Mains Incoming Cable Size

mm

70

70

185

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

24

24

24

Unit Data - Cooling Only

Mains Supply

Control Circuit

VAC

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

3 x 2.9

3 x 2.9

3 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

22.5

20.3

22.5

Current Per Phase

32.5

30.9

59.1

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CL00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

151

SmartCool 6 - 200kW
Technical Data SD CL00 Units

Precision Air Conditioning


SD31D235-CL00

Mechanical Data

CL00

SD

Technical

SD31D235-CL00-0

152

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD31D235-CL00-1

SD31D235-CL00-2

186.4
186.4
186.4
5.9
5.9
5.9
3100 x 890 x 1980
3100 x 890 x 1980
3100 x 890 x 1980
690 / 305 / 1101
690 / 305 / 1101
690 / 305 / 1101
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
107
107
107
7.4
7.4
7.4
67.1
67.1
67.1
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1374 / 1657
1374 / 1657
1374 / 1657
428
428
428
11.3
11.3
11.3

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power. All other options quote shaft power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units

SD31D235-CL00

Electrical Data
Unit Data - Full Function

SD31D235-CL00-0

SD31D235-CL00-1

SD31D235-CL00-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CL00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

153

SmartCool 6 - 200kW
Technical Data SD CL00 Units

Precision Air Conditioning


SD35D270-CL00

Mechanical Data

CL00

SD

Technical

SD35D270-CL00-0

154

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD35D270-CL00-1

SD35D270-CL00-2

215.4
215.4
215.4
7.8
7.8
7.8
3500 x 890 x 1980
3500 x 890 x 1980
3500 x 890 x 1980
745 / 326 / 1190
745 / 326 / 1190
745 / 326 / 1190
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
120
120
120
8.6
8.6
8.6
95.1
95.1
95.1
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1532 / 1657
1532 / 1657
1532 / 1657
225
225
225
13.0
13.0
13.0

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Machine weight excludes water charge.
(4) Backward curved EC fan options quote electrical power. All other options quote shaft power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units

SD35D270-CL00

Electrical Data
Unit Data - Full Function

SD35D270-CL00-0

SD35D270-CL00-1

SD35D270-CL00-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

24

24

24

Unit Data - Cooling Only

Mains Supply

Control Circuit

VAC

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CL00
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

155

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CL00 Units


Waterside Pressure Drop Data
300.0
280.0
260.0

240.0
220.0

Technical

Pressure Drop (kPa)

200.0
180.0

1 and 3

160.0
140.0
120.0
100.0
80.0
60.0
40.0
20.0

SD

0.0
0.00

2.00

4.00

SD18D115-CL00-0

1
2
3

6.00
Flow Rate (l/s)
SD22D145-CL00-0

8.00

SD25D180-CL00-0

SD18D115 -CL00-0
SD22D145-CL00-0
SD25D180-CL00-0

CL00

Includes coil, 2 port valve and pipework.


To calculate 2 port valve pressure drop:
P valve =

Q

M

where
P = Pressure Drop in kPa,
Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

156

Kv Cooling

Kv Bypass

SD18D115-CL00

40

40

SD22D145-CL00

63

40

SD25D180-CL00

63

40

10.00

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

12.00

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units


Waterside Pressure Drop Data

300.00

250.00

5
4

150.00

Technical

Pressure Drop (kPa)

200.00

100.00

50.00

0.00

2.00

4.00

6.00

8.00

10.00

12.00

14.00

16.00

SD

0.00
Flow Rate (l/s)
SD31D235-CL00-0
SD35D270-CL00-0

4
5

SD31D235-CL00-0
SD35D270-CL00-0

Includes coil, 2 port valve and pipework.


To calculate 2 port valve pressure drop:
Q

M

CL00

P valve =

where P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

Kv Cooling

Kv Bypass

SD31D235-CL00

63

63

SD35D270-CL00

63

63

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

157

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CL00 Units


Sound Data

SD18D115-CL00-0

SD

Technical

SD22D145-CL00-0

SD25D180-CL00-0

SD31D235-CL00-0

SD35D270-CL00-0

Frequency (Hz) dB

Overall
dB(A)

63

125

250

500

1000

2000

4000

8000

Discharge Air

63.0

66.1

77.1

63.9

56.1

49.9

47.3

39.9

32.2

Return Air

58.3

64.3

71.3

59.2

52.7

46.8

47.1

39.6

32.1

Sound Measurement

Case Breakout

64.3

71.6

76.3

66.7

60.4

54.0

50.5

46.5

37.9

Sound Pressure @ 3m

49.8

57.1

61.8

52.1

45.8

39.4

36.0

31.9

23.3

Discharge Air

66.0

69.2

80.1

66.9

58.9

53.1

50.7

43.4

35.6

Return Air

61.3

67.5

74.4

62.2

55.5

49.9

50.5

43.1

35.4

Case Breakout

67.3

74.8

79.4

69.7

63.2

57.2

53.9

50.0

41.2

Sound Pressure @ 3m

52.8

60.2

64.8

55.1

48.6

42.6

39.4

35.4

26.6

Discharge Air

66.0

69.2

80.1

66.9

59.1

53.0

50.5

43.1

35.4

Return Air

61.3

67.4

74.4

62.3

55.7

49.9

50.3

42.8

35.2

Case Breakout

67.4

74.7

79.4

69.7

63.4

57.1

53.7

49.7

41.0

Sound Pressure @ 3m

52.8

60.2

64.9

55.2

48.8

42.5

39.2

35.1

26.5

Discharge Air

66.7

69.8

80.8

67.6

59.8

53.6

51.1

43.7

36.0

Return Air

62.0

68.0

75.0

62.9

56.3

50.5

50.9

43.4

35.8

Case Breakout

68.0

75.3

80.0

70.4

64.0

57.7

54.3

50.2

41.6

Sound Pressure @ 3m

53.5

60.8

65.5

55.8

49.5

43.2

39.7

35.7

27.0

Discharge Air

69.6

72.8

83.7

70.4

62.4

56.7

54.4

47.1

39.2

Return Air

64.9

71.1

77.9

65.8

59.0

53.6

54.2

46.8

39.1

Case Breakout

70.9

78.4

82.9

73.2

66.7

60.8

57.6

53.7

44.8

Sound Pressure @ 3m

56.4

63.8

68.4

58.7

52.1

46.3

43.1

39.1

30.3

CL00

(1) dB(A) is the overall sound level, measured on the A scale


(2) All sound data measured at nominal conditions, Discharge Air, Return air and case breakout is sound power.

158

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CL00 Units


Interconnecting Wiring
Neutral (Supply 1)

L1 (Supply 1)

302

L2 (Supply 1)

303

L3 (Supply 1)

N2

Neutral (Supply 2)

304

L1 (Supply 2)

305

L2 (Supply 2)

306

L3 (Supply 2)

PE

Protective Earth

502

Fire Detector

583

Fire Detector

583

Smoke Detector

584

Smoke Detector

502

Remote On/Off

522

Remote On/Off

Condensate Pump Supply (230V)

N (3*)

Condensate Pump Supply (230V)

534

Condensate Pump High Level Alarm

535

Condensate Pump High Level Alarm

609

Flood Detection Tape / Probe

610

Flood Detection Tape / Probe

810

Supply Air Temperature Sensor

811

Supply Air Temperature Sensor

560

Non-Critical Alarm N/O

561

Non-Critical Alarm Common

563

Critical Alarm N/O

564

Critical Alarm Common

565

Critical Alarm N/C

881

BMS Connection

882

BMS Connection

883

BMS Connection

CL00

SD

301

Technical

N1

*For 220V/3PH NO neutral units the Neutral connection is replaced with a live phase.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

159

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CHCH Units


Performance Data SD CHCH
Chilled water inlet and outlet temperatures
Model

SD18D085-CHCH-0

Technical

SD22D105-CHCH-0

SD25D135-CHCH-0

SD

SD31D165-CHCH-0

5 / 10 C

7 / 12 C

8 / 14 C

160

10 / 16 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

22 / 50

83.0

75.5

63.4

63.4

51.4

51.4

37.6

37.6

24 / 45

95.6

86.9

75.2

75.2

64.3

64.3

52.4

52.4

26 / 40

106.2

98.2

86.6

86.6

76.3

76.3

65.0

65.0

22 / 50

114.2

98.4

83.9

83.9

71.1

71.1

55.8

55.8

24 / 45

130.2

112.3

98.3

98.3

86.2

86.2

71.8

71.8

26 / 40

143.8

126.3

112.3

112.3

100.7

100.7

86.6

86.6

22 / 50

147.6

124.3

109.4

105.1

91.6

91.6

73.1

73.1

24 / 45

175.0

151.2

128.4

121.0

110.0

110.0

92.2

92.2

26 / 40

184.1

159.1

145.4

138.9

127.9

127.9

110.4

110.4

22 / 50

171.4

155.9

130.7

130.7

106.3

106.3

78.4

78.4

24 / 45

197.3

179.3

155.0

155.0

132.7

132.7

108.3

108.3

26 / 40

218.9

202.7

178.5

178.5

157.4

157.4

134.1

134.1

22 / 50

207.7

184.4

156.0

156.0

130.3

130.3

100.7

100.7

24 / 45

237.3

211.3

183.6

183.6

159.6

159.6

131.9

131.9

26 / 40

262.6

238.2

210.5

210.5

187.5

187.5

160.7

160.7

CHCH

SD35D195-CHCH-0

Air On

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units


Performance Data SD CHCH
Chilled water inlet and outlet temperatures
Model

SD18D085-CHCH-0

SD22D105-CHCH-0

SD31D165-CHCH-0

17 / 22 C

18 / 24C

20 / 26 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

33 / 26

81.0

81.0

70.1

70.1

60.3

60.3

48.7

48.7

35 / 24

91.4

91.4

80.7

80.7

71.3

71.3

60.2

60.2

37 / 22

101.7

101.7

91.1

91.1

82.1

82.1

71.3

71.3

33 / 26

104.7

104.7

91.1

91.1

79.7

79.7

65.4

65.4

35 / 24

117.4

117.4

104.0

104.0

93.2

93.2

79.4

79.4

37 / 22

130.3

130.3

117.0

117.0

106.5

106.5

93.0

93.0

33 / 26

131.9

131.9

115.0

115.0

101.2

101.2

83.6

83.6

35 / 24

147.8

147.8

131.0

131.0

117.9

117.9

100.7

100.7

37 / 22

163.8

163.8

147.2

147.2

134.4

134.4

117.5

117.5

33 / 26

167.0

167.0

144.5

144.5

124.4

124.4

100.5

100.5

35 / 24

188.2

188.2

166.2

166.2

147.0

147.0

124.2

124.2

37 / 22

209.5

209.5

187.8

187.8

169.1

169.1

147.0

147.0

33 / 26

196.5

196.5

170.5

170.5

148.1

148.1

121.0

121.0

35 / 24

220.8

220.8

195.4

195.4

173.9

173.9

147.7

147.7

37 / 22

245.3

245.3

220.1

220.1

199.5

199.5

173.7

173.7

SD

SD35D195-CHCH-0

15 / 20 C

Technical

SD25D135-CHCH-0

Air On

CHCH
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

161

SmartCool 6 - 200kW
Technical Data SD CHCH Units

Precision Air Conditioning


SD18D085-CHCH

Mechanical Data

CHCH

SD

Technical

SD18D085-CHCH-0

162

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD18D085-CHCH-2

75.2
75.2
75.2
2.3
2.3
2.3
1800 x 890 x 1980
1800 x 890 x 1980
1800 x 890 x 1980
477 / 175 / 702
477 / 175 / 702
477 / 175 / 702
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
50
50
50
3.6
3.6
3.6
23.0
23.0
23.0
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1266 / 1657
1266 / 1657
1266 / 1657
538
538
538
5.3
5.3
5.3

mm
mm

54
22

kW

6
15.0

kg/hr
l/m

SD18D085-CHCH-1

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

8
8
8
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units

SD18D085-CHCH

Electrical Data
Unit Data - Full Function

SD18D085-CHCH-0

SD18D085-CHCH-1

SD18D085-CHCH-2

(1)

Nominal Run Amps

40.3

39.7

72.2

Recommended Mains Fuse Size

50

50

100

Nominal Run Amps

9.9

9.9

17.0

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

Quantity x Motor Size

Humidifier
kg/hr

kW

6.0

6.0

6.0

Full Load Amps

8.7

9.2

15.8

SD

Capacity
Rating

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CHCH
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

163

SmartCool 6 - 200kW
Technical Data SD CHCH Units

Precision Air Conditioning


SD22D105-CHCH

Mechanical Data

CHCH

SD

Technical

SD22D105-CHCH-0

164

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD22D105-CHCH-1

SD22D105-CHCH-2

98.3
98.3
98.3
3.5
3.5
3.5
2200 x 890 x 1980
2200 x 890 x 1980
2200 x 890 x 1980
547 / 189 / 798
547 / 189 / 798
547 / 189 / 798
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
62
62
62
4.7
4.7
4.7
39.5
39.5
39.5
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1491 / 1657
1491 / 1657
1491 / 1657
287
287
287
6.5
6.5
6.5

mm
mm

54
22

kW

6
15.0

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units

SD22D105-CHCH

Electrical Data
Unit Data - Full Function

SD22D105-CHCH-0

SD22D105-CHCH-1

SD22D105-CHCH-2

(1)

Nominal Run Amps

64.2

64.7

115.6

Recommended Mains Fuse Size

80

80

160

Nominal Run Amps

9.9

9.9

17.0

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

70

70

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CHCH
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

165

SmartCool 6 - 200kW
Technical Data SD CHCH Units

Precision Air Conditioning


SD25D135-CHCH

Mechanical Data

CHCH

SD

Technical

SD25D135-CHCH-0

166

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD25D135-CHCH-1

SD25D135-CHCH-2

128.4
128.4
128.4
4.1
4.1
4.1
2500 x 890 x 1980
2500 x 890 x 1980
2500 x 890 x 1980
618 / 244 / 940
618 / 244 / 940
618 / 244 / 940
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
79
79
79
6.1
6.1
6.1
43.5
43.5
43.5
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
3 x 2.9
3 x 2.9
3 x 2.9
1337 / 1657
1337 / 1657
1337 / 1657
463
463
463
8.2
8.2
8.2

mm
mm

67
22

kW

6
22.5

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
20.3

67
22
6
22.5

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units

SD25D135-CHCH

Electrical Data
Unit Data - Full Function

SD25D135-CHCH-0

SD25D135-CHCH-1

SD25D135-CHCH-2

(1)

Nominal Run Amps

79.4

79.4

142.8

Recommended Mains Fuse Size

100

100

200

Nominal Run Amps

14.3

14.3

24.5

Recommended Mains Fuse Size

20

20

32

Max Mains Incoming Cable Size

mm

70

70

185

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type

EC

EC

3 x 2.9

3 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Full Load Amps

(2) kW
A

OPTIONAL EXTRAS
Electric Heating

Rating

kW

22.5

20.3

22.5

Current Per Phase

32.5

30.9

59.1

Technical

EC
3 x 2.9

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CHCH
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

167

SmartCool 6 - 200kW
Technical Data SD CHCH Units

Precision Air Conditioning


SD31D165-CHCH

Mechanical Data

CHCH

SD

Technical

SD31D165-CHCH-0

168

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD31D165-CHCH-1

SD31D165-CHCH-2

155.0
155.0
155.0
5.4
5.4
5.4
3100 x 890 x 1980
3100 x 890 x 1980
3100 x 890 x 1980
727 / 305 / 1127
727 / 305 / 1127
727 / 305 / 1127
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
96
96
96
7.4
7.4
7.4
37.1
37.1
37.1
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1322 / 1657
1322 / 1657
1322 / 1657
473
473
473
10.7
10.7
10.7

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units

SD31D165-CHCH

Electrical Data
Unit Data - Full Function

SD31D165-CHCH-0

SD31D165-CHCH-1

SD31D165-CHCH-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

24

24

24

Unit Data - Cooling Only

Mains Supply

Control Circuit

VAC

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CHCH
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

169

SmartCool 6 - 200kW
Technical Data SD CHCH Units

Precision Air Conditioning


SD35D195-CHCH

Mechanical Data

CHCH

SD

Technical

SD35D195-CHCH-0

170

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD35D195-CHCH-1

SD35D195-CHCH-2

183.6
183.6
183.6
7.2
7.2
7.2
3500 x 890 x 1980
3500 x 890 x 1980
3500 x 890 x 1980
788 / 326 / 1221
788 / 326 / 1221
788 / 326 / 1221
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
108
108
108
8.7
8.7
8.7
51.3
51.3
51.3
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1479 / 1657
1479 / 1657
1479 / 1657
302
302
302
12.4
12.4
12.4

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 24C / 45% RH water 7C / 12C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units

SD35D195-CHCH

Electrical Data
Unit Data - Full Function

SD35D195-CHCH-0

SD35D195-CHCH-1

SD35D195-CHCH-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CHCH
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

171

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CHCH Units


Waterside Pressure Drop Data

140.0
120.0

Technical

Pressure Drop (kPa)

100.0

80.0

60.0
40.0

SD

20.0
0.0
0.00

1.00

2.00

3.00

SD18D085-CHCH-0

CHCH

1
2
3

4.00

5.00

Flow Rate (l/s)


SD22D105-CHCH-0

6.00

7.00

SD25D135-CHCH-0

SD18D085-CHCH-0
SD22D105-CHCH-0
SD25D135-CHCH-0

Includes coil, 2 port valve and pipework.


To calculate 2 port valve pressure drop:
P valve =
where

Q

M

P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.


Kv Cooling

172

Kv Bypass

SD18D110-CH00

40

40

SD22D140-CH00

63

40

SD25D175-CH00

63

40

8.00

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

9.00

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units


Waterside Pressure Drop Data

120.00

100.00

4 and 5

60.00

Technical

Pressure Drop (kPa)

80.00

40.00

20.00

SD

0.00
0.00

2.00

4.00

6.00

8.00

10.00

12.00

14.00

Flow Rate (l/s)


SD31D165-CHCH-0
SD35D195-CHCH-0

4
5

SD31D165-CHCH-0
SD35D195-CHCH-0

To calculate 2 port valve pressure drop:


P valve =

Q

M

CHCH

Includes coil, 2 port valve and pipework.

where P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

Kv Cooling

Kv Bypass

SD31D215-CH00

63

63

SD35D255-CH00

63

63

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

173

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CHCH Units


Sound Data

Sound Measurement

SD18D085-CHCH-0

Technical

SD22D105-CHCH-0

SD25D135-CHCH-0

SD

SD31D165-CHCH-0

SD35D195-CHCH-0

Overall
dB(A)

Frequency (Hz) dB
63

125

250

500

1000

4000

8000

Discharge Air

61.8

64.9

75.9

62.7

54.9

48.7

46.2

38.7

31.1

Return Air

57.1

63.2

70.2

58.1

51.5

45.6

46.0

38.4

30.9

Case Breakout

63.2

70.4

75.2

65.5

59.2

52.8

49.3

45.3

36.7

Sound Pressure @ 3m

48.6

55.9

60.6

51.0

44.7

38.3

34.8

30.8

22.1

Discharge Air

65.8

69.0

79.9

66.6

58.7

52.8

50.5

43.1

35.3

Return Air

61.1

67.2

74.1

62.0

55.3

49.7

50.3

42.8

35.1

Case Breakout

67.1

74.5

79.1

69.5

63.0

56.9

53.7

49.7

40.9

Sound Pressure @ 3m

52.6

60.0

64.6

54.9

48.4

42.4

39.1

35.1

26.4

Discharge Air

64.8

67.9

78.9

65.7

57.9

51.7

49.2

41.7

34.1

Return Air

60.1

66.1

73.2

61.0

54.5

48.6

49.0

41.4

33.9

Case Breakout

66.1

73.4

78.2

68.5

62.2

55.8

52.3

48.3

39.7

Sound Pressure @ 3m

51.6

58.9

63.6

54.0

47.6

41.3

37.8

33.8

25.1

Discharge Air

65.8

68.9

79.9

66.7

58.9

52.7

50.1

42.7

35.0

Return Air

61.1

67.1

74.2

62.0

55.5

49.6

49.9

42.4

34.9

Case Breakout

67.1

74.4

79.2

69.5

63.2

56.8

53.3

49.3

40.7

Sound Pressure @ 3m

52.6

59.9

64.6

54.9

48.6

42.2

38.8

34.7

26.1

Discharge Air

68.5

71.8

82.6

69.4

61.5

55.6

53.2

45.8

38.0

Return Air

63.9

70.0

76.9

64.8

58.1

52.5

53.0

45.5

37.9

Case Breakout

69.9

77.3

81.9

72.2

65.8

59.7

56.4

52.4

43.7

Sound Pressure @ 3m

55.4

62.8

67.4

57.7

51.2

45.1

41.9

37.9

29.1

CHCH

(1) dB(A) is the overall sound level, measured on the A scale


(2) All sound data measured at nominal conditions, Discharge Air, Return air and case breakout is sound power.

174

2000

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CHCH Units


Interconnecting Wiring
Neutral (Supply 1)

L1 (Supply 1)

302

L2 (Supply 1)

303

L3 (Supply 1)

N2

Neutral (Supply 2)

304

L1 (Supply 2)

305

L2 (Supply 2)

306

L3 (Supply 2)

PE

Protective Earth

502

Fire Detector

583

Fire Detector

583

Smoke Detector

584

Smoke Detector

502

Remote On/Off

522

Remote On/Off

Condensate Pump Supply (230V)

N (3*)

Condensate Pump Supply (230V)

534

Condensate Pump High Level Alarm

535

Condensate Pump High Level Alarm

609

Flood Detection Tape / Probe

610

Flood Detection Tape / Probe

810

Supply Air Temperature Sensor

811

Supply Air Temperature Sensor

560

Non-Critical Alarm N/O

561

Non-Critical Alarm Common

563

Critical Alarm N/O

564

Critical Alarm Common

565

Critical Alarm N/C

881

BMS Connection

882

BMS Connection

883

BMS Connection

CHCH

SD

301

Technical

N1

*For 220V/3PH NO neutral units the Neutral connection is replaced with a live phase.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

175

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CLCL Units


Performance Data SD CLCL
Chilled water inlet and outlet temperatures
Air On

SD18D090-CLCL-0

Technical

SD22D120-CLCL-0

SD25D140-CLCL-0

SD

SD31D190-CLCL-0

7 / 12 C

8 / 14 C

176

10 / 16 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

22 / 50

94.3

79.6

69.8

67.5

58.6

58.6

46.6

46.6

24 / 45

106.8

90.7

82.0

77.7

70.4

70.4

58.9

58.9

26 / 40

117.7

101.9

93.0

89.2

81.9

81.9

70.6

70.6

22 / 50

125.6

101.9

96.9

89.1

76.8

76.8

62.0

62.0

24 / 45

141.4

115.7

112.7

103.0

91.4

91.4

77.0

77.0

26 / 40

155.0

129.6

126.1

117.0

105.6

105.6

91.4

91.4

22 / 50

147.6

124.3

109.4

105.1

91.6

91.6

73.1

73.1

24 / 45

175.0

151.2

128.4

121.0

110.0

110.0

92.2

92.2

26 / 40

184.1

159.1

145.4

138.9

127.9

127.9

110.4

110.4

22 / 50

205.3

167.7

158.0

146.6

126.0

126.0

101.8

101.8

24 / 45

231.2

190.5

183.8

169.7

150.0

150.0

126.4

126.4

26 / 40

253.3

213.4

205.9

192.8

173.3

173.3

150.2

150.2

22 / 50

242.8

195.7

188.4

171.3

148.2

148.2

120.3

120.3

24 / 45

272.6

222.1

218.3

197.8

175.8

175.8

148.6

148.6

26 / 40

298.2

248.5

243.9

224.5

202.8

202.8

175.9

175.9

CLCL

SD35D225-CLCL-0

5 / 10 C

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units


Performance Data SD CLCL
Chilled water inlet and outlet temperatures
Air On

SD18D090-CLCL-0

SD22D120-CLCL-0

SD31D190-CLCL-0

18 / 24C

20 / 26 C

Temp. (C)

TC

SC

TC

SC

TC

SC

TC

SC

/ %RH

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

33 / 26

84.5

84.5

73.6

73.6

64.8

64.8

53.5

53.5

35 / 24

94.7

94.7

83.9

83.9

75.5

75.5

64.4

64.4

37 / 22

104.9

104.9

94.3

94.3

86.1

86.1

75.2

75.2

33 / 26

107.9

107.9

94.2

94.2

83.7

83.7

69.6

69.6

35 / 24

120.4

120.4

107.1

107.1

96.9

96.9

83.2

83.2

37 / 22

133.2

133.2

119.9

119.9

110.1

110.1

96.5

96.5

33 / 26

131.9

131.9

115.0

115.0

101.2

101.2

83.6

83.6

35 / 24

147.8

147.8

131.0

131.0

117.9

117.9

100.7

100.7

37 / 22

163.8

163.8

147.2

147.2

134.4

134.4

117.5

117.5

33 / 26

177.2

177.2

154.7

154.7

137.4

137.4

114.1

114.1

35 / 24

197.9

197.9

175.8

175.8

159.1

159.1

136.5

136.5

37 / 22

218.9

218.9

197.0

197.0

180.7

180.7

158.5

158.5

33 / 26

206.5

206.5

180.4

180.4

160.7

160.7

133.9

133.9

35 / 24

230.4

230.4

204.9

204.9

185.8

185.8

159.7

159.7

37 / 22

254.6

254.6

229.3

229.3

210.9

210.9

185.0

185.0

SD

SD35D225-CLCL-0

17 / 22 C

Technical

SD25D140-CLCL-0

15 / 20 C

CLCL
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

177

SmartCool 6 - 200kW
Technical Data SD CLCL Units

Precision Air Conditioning


SD18D090-CLCL

Mechanical Data

CLCL

SD

Technical

SD18D090-CLCL-0

178

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD18D090-CLCL-2

75.3
75.3
75.3
2.3
2.3
2.3
1800 x 890 x 1980
1800 x 890 x 1980
1800 x 890 x 1980
477 / 175 / 702
477 / 175 / 702
477 / 175 / 702
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
50
50
50
3.0
3.0
3.0
23.1
23.1
23.1
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1266 / 1657
1266 / 1657
1266 / 1657
538
538
538
5.3
5.3
5.3

mm
mm

54
22

kW

6
15.0

kg/hr
l/m

SD18D090-CLCL-1

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

8
8
8
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units

SD18D090-CLCL

Electrical Data
Unit Data - Full Function

SD18D090-CLCL-0

SD18D090-CLCL-1

SD18D090-CLCL-2

(1)

Nominal Run Amps

40.3

39.7

72.2

Recommended Mains Fuse Size

50

50

100

Nominal Run Amps

9.9

9.9

17.0

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

35

35

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

2 x 2.9

2 x 2.9

2 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

Quantity x Motor Size

Humidifier
kg/hr

kW

6.0

6.0

6.0

Full Load Amps

8.7

9.2

15.8

SD

Capacity
Rating

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CLCL
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

179

SmartCool 6 - 200kW
Technical Data SD CLCL Units

Precision Air Conditioning


SD22D120-CLCL

Mechanical Data

CLCL

SD

Technical

SD22D120-CLCL-0

180

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD22D120-CLCL-1

SD22D120-CLCL-2

96.7
96.7
96.7
3.5
3.5
3.5
2200 x 890 x 1980
2200 x 890 x 1980
2200 x 890 x 1980
547 / 189 / 798
547 / 189 / 798
547 / 189 / 798
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
62
62
62
3.8
3.8
3.8
41.0
41.0
41.0
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
2 x 2.9
2 x 2.9
2 x 2.9
1491 / 1657
1491 / 1657
1491 / 1657
287
287
287
6.5
6.5
6.5

mm
mm

54
22

kW

6
15.0

54
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
13.5

54
22
6
15.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units

SD22D120-CLCL

Electrical Data
Unit Data - Full Function

SD22D120-CLCL-0

SD22D120-CLCL-1

SD22D120-CLCL-2

(1)

Nominal Run Amps

64.2

64.7

115.6

Recommended Mains Fuse Size

80

80

160

Nominal Run Amps

9.9

9.9

17.0

Recommended Mains Fuse Size

16

16

20

Max Mains Incoming Cable Size

mm

70

70

70

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type

EC

EC

2 x 2.9

2 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Full Load Amps

(2) kW
A

OPTIONAL EXTRAS
Electric Heating

Rating

kW

15.0

13.5

15.0

Current Per Phase

21.7

20.6

39.4

Technical

EC
2 x 2.9

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CLCL
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

181

SmartCool 6 - 200kW
Technical Data SD CLCL Units

Precision Air Conditioning


SD25D140-CLCL

Mechanical Data

CLCL

SD

Technical

SD25D140-CLCL-0

182

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD25D140-CLCL-1

SD25D140-CLCL-2

117.6
117.6
117.6
4.1
4.1
4.1
2500 x 890 x 1980
2500 x 890 x 1980
2500 x 890 x 1980
618 / 244 / 940
618 / 244 / 940
618 / 244 / 940
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
79
79
79
4.7
4.7
4.7
25.5
25.5
25.5
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
3 x 2.9
3 x 2.9
3 x 2.9
1337 / 1657
1337 / 1657
1337 / 1657
463
463
463
8.2
8.2
8.2

mm
mm

67
22

kW

6
22.5

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
6
20.3

67
22
6
22.5

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units

SD25D140-CLCL

Electrical Data
Unit Data - Full Function

SD25D140-CLCL-0

SD25D140-CLCL-1

SD25D140-CLCL-2

(1)

Nominal Run Amps

79.4

79.4

142.8

Recommended Mains Fuse Size

100

100

200

Nominal Run Amps

14.3

14.3

24.5

Recommended Mains Fuse Size

20

20

32

Max Mains Incoming Cable Size

mm

70

70

185

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type

EC

EC

3 x 2.9

3 x 2.9

4.5

4.5

7.5

Stage of Reheat

Number of Elements

Full Load Amps

(2) kW
A

OPTIONAL EXTRAS
Electric Heating

Rating

kW

22.5

20.3

22.5

Current Per Phase

32.5

30.9

59.1

Technical

EC
3 x 2.9

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CLCL
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

183

SmartCool 6 - 200kW
Technical Data SD CLCL Units

Precision Air Conditioning


SD31D190-CLCL

Mechanical Data

CLCL

SD

Technical

SD31D190-CLCL-0

184

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD31D190-CLCL-1

SD31D190-CLCL-2

158.8
158.8
158.8
5.4
5.4
5.4
3100 x 890 x 1980
3100 x 890 x 1980
3100 x 890 x 1980
727 / 305 / 1127
727 / 305 / 1127
727 / 305 / 1127
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
96
96
96
6.3
6.3
6.3
49.7
49.7
49.7
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1322 / 1657
1322 / 1657
1322 / 1657
473
473
473
10.7
10.7
10.7

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units

SD31D190-CLCL

Electrical Data
Unit Data - Full Function

SD31D190-CLCL-0

SD31D190-CLCL-1

SD31D190-CLCL-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

24

24

24

Unit Data - Cooling Only

Mains Supply

Control Circuit

VAC

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CLCL
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

185

SmartCool 6 - 200kW
Technical Data SD CLCL Units

Precision Air Conditioning


SD35D225-CLCL

Mechanical Data

CLCL

SD

Technical

SD35D225-CLCL-0

186

Capacity
Nom Cooling (Gross)
Fan Power Input (Fan Gain)
Dimensions - W x D x H
Weight - Machine Case / Fan Module / Operating
Construction
Material/Colour
Cooling Coil
Cooling / Dehum Stages
Water Volume
Water Flow Rate
Pressure Drop
Fan & Motor
Motor Type
Quantity x Motor Size
Speed @25Pa ESP / Maximum ESP
Maximum ESP
Nominal Airflow
Connections
Water Inlet / Outlet Condensate Drain Hose
Filtration
Quantity
Electric Heating (Total)
Humidifier
Capacity
Drain Pump Flow Rate
Feed / Drain
Hot Water Condensate Pump
Head
Flow
Drain
Cold Water Condensate Pump
Head
Flow
Drain
Upgraded Fan Motor - EC Motor
Quantity x Motor Size
Speed @ 25Pa / Maximum ESP
Maximum ESP

(1) kW
(2) kW
mm
(3) kg

l
l/s
kPa

(4) kW
rpm
Pa
m/s

SD35D225-CLCL-1

SD35D225-CLCL-2

185.4
185.4
185.4
7.2
7.2
7.2
3500 x 890 x 1980
3500 x 890 x 1980
3500 x 890 x 1980
788 / 326 / 1221
788 / 326 / 1221
788 / 326 / 1221
Frame: Sheet Metal Folded Profile, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint / Black Grey (RAL 7021)
Copper Tube / Turbulated Hydrophillic Coated Aluminium Fins
1 (Modulated) / 1
108
108
108
7.4
7.4
7.4
72.1
72.1
72.1
Backwards Curved, Centrifugal Direct Drive
EC
EC
EC
4 x 2.9
4 x 2.9
4 x 2.9
1479 / 1657
1479 / 1657
1479 / 1657
302
302
302
12.4
12.4
12.4

mm
mm

67
22

kW

9
30.0

67
22
Disposable to BS EN779:2012 - G4 - 75mm Deep
9
27.1

67
22
9
30.0

kg/hr
l/m

30
30
30
7
7
7
3/4 BSPF Braided Flexible Hose / 22mm Hose Connection

m
l/m

5
9.0

5
9.0
10mm Stainless Steel Stub Connection

5
9.0

m
l/m

5
3.1

5
3.1
10mm Plastic Barb Connection

5
3.1

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

(4) kW
rpm
Pa

(1) Entering air 35C / 24% RH water 18C / 24C


(2) Fan gain/ fan power input is shown for a unit delivering nominal air volume with 25Pa ESP. The fan gain / fan power values will change when selected with alternative airflow or
ESP values.
(3) Operating weight includes case and fan module.
(4) Backward curved EC fan options quote electrical power.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units

SD35D225-CLCL

Electrical Data
Unit Data - Full Function

SD35D225-CLCL-0

SD35D225-CLCL-1

SD35D225-CLCL-2

(1)

Nominal Run Amps

94.7

94.1

170.0

Recommended Mains Fuse Size

125

125

200

Nominal Run Amps

18.7

18.7

32.0

Recommended Mains Fuse Size

25

25

40

Max Mains Incoming Cable Size

mm

70

70

185

Mains Supply

400V / 3PH + N / 50Hz

380V / 3PH + N / 60Hz

220V / 3PH / 60Hz

Control Circuit

VAC

24

24

24

Unit Data - Cooling Only

Evaporator Fan - Motor - Per Fan


Motor Type
Full Load Amps

(2) kW
A

EC

EC

EC

4 x 2.9

4 x 2.9

4 x 2.9

4.5

4.5

7.5

OPTIONAL EXTRAS
Electric Heating
Stage of Reheat

Number of Elements

12

12

12

Rating

kW

30.0

27.1

30.0

Current Per Phase

43.4

41.2

78.8

Technical

Quantity x Motor Size

Humidifier
kg/hr

30

30

30

Rating

kW

22.5

22.5

22.5

Full Load Amps

32.6

34.2

59.2

SD

Capacity

(1) Values given for full function units with standard selections for heating, humidification, supply air fans.
(2) Stated motor power is based on maximum electrical power absorbed

CLCL
SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

187

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CLCL Units


Waterside Pressure Drop Data
250.00

200.00

Technical

Pressure Drop (kPa)

2
150.00

100.00

SD

50.00

0.00
0.00

1.00

2.00

3.00

SD18D090-CLCL-0

CLCL

1
2
3

4.00

5.00

Flow Rate (l/s)


SD22D120-CLCL-0

6.00

SD25D140-CLCL-0

SD18D090 - CLCL-0
SD22D120 - CLCL-0
SD25D140 - CLCL-0

Includes coil, 2 port valve and pipework.


To calculate 3 port valve pressure drop:
P valve =

Q

M

where P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

188

Kv Cooling

Kv Bypass

SD18D090-CLCL

40

40

SD22D120-CLCL

40

40

SD25D140-CLCL

63

63

7.00

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

8.00

9.00

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units


Waterside Pressure Drop Data
250.00

5
4

150.00

Technical

Pressure Drop (kPa)

200.00

100.00

50.00

0.00

2.00

4.00

6.00

8.00

10.00

12.00

14.00

SD

0.00
Flow Rate (l/s)
SD31D190-CLCL-0

4
5

SD35D225-CLCL-0

SD31D190 - CLCL-0
SD35D225 - CLCL-0

To calculate 3 port valve pressure drop:


P valve =

Q

M

CLCL

Includes coil, 2 port valve and pipework.

where P = Pressure Drop in kPa,


Kv

Q = Water Flow Rate in l/s and M = 36

Fluid 100% water.

Kv Cooling

Kv Bypass

SD31D190-CLCL

63

63

SD35D225-CLCL

63

63

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

189

SmartCool 6 - 200kW

Precision Air Conditioning

Technical Data SD CLCL Units


Sound Data

SD18D090-CLCL-0

SD

Technical

SD22D120-CLCL-0

SD25D135-CLCL-0

SD31D190-CLCL-0

SD35D225-CLCL-0

Frequency (Hz) dB

Overall
dB(A)

63

125

250

500

1000

2000

4000

8000

Discharge Air

61.8

64.9

75.9

62.7

54.9

48.7

46.2

38.7

31.1

Return Air

57.1

63.2

70.2

58.1

51.5

45.6

46.0

38.4

30.9

Case Breakout

63.2

70.4

75.2

65.5

59.2

52.8

49.3

45.3

36.7

Sound Pressure @ 3m

48.6

55.9

60.6

51.0

44.7

38.3

34.8

30.8

22.1

Discharge Air

65.8

69.0

79.9

66.6

58.7

52.8

50.5

43.1

35.3

Return Air

61.1

67.2

74.1

62.0

55.3

49.7

50.3

42.8

35.1

Case Breakout

67.1

74.5

79.1

69.5

63.0

56.9

53.7

49.7

40.9

Sound Pressure @ 3m

52.6

60.0

64.6

54.9

48.4

42.4

39.1

35.1

26.4

Discharge Air

64.8

67.9

78.9

65.7

57.9

51.7

49.2

41.7

34.1

Return Air

60.1

66.1

73.2

61.0

54.5

48.6

49.0

41.4

33.9

Case Breakout

66.1

73.4

78.2

68.5

62.2

55.8

52.3

48.3

39.7

Sound Pressure @ 3m

51.6

58.9

63.6

54.0

47.6

41.3

37.8

33.8

25.1

Discharge Air

65.8

68.9

79.9

66.7

58.9

52.7

50.1

42.7

35.0

Return Air

61.1

67.1

74.2

62.0

55.5

49.6

49.9

42.4

34.9

Case Breakout

67.1

74.4

79.2

69.5

63.2

56.8

53.3

49.3

40.7

Sound Pressure @ 3m

52.6

59.9

64.6

54.9

48.6

42.2

38.8

34.7

26.1

Discharge Air

68.5

71.8

82.6

69.4

61.5

55.6

53.2

45.8

38.0

Return Air

63.9

70.0

76.9

64.8

58.1

52.5

53.0

45.5

37.9

Case Breakout

69.9

77.3

81.9

72.2

65.8

59.7

56.4

52.4

43.7

Sound Pressure @ 3m

55.4

62.8

67.4

57.7

51.2

45.1

41.9

37.9

29.1

Sound Measurement

CLCL

(1) dB(A) is the overall sound level, measured on the A scale


(2) All sound data measured at nominal conditions, Discharge Air, Return air and case breakout is sound power.

190

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

Technical Data SD CLCL Units


Interconnecting Wiring
Neutral (Supply 1)

L1 (Supply 1)

302

L2 (Supply 1)

303

L3 (Supply 1)

N2

Neutral (Supply 2)

304

L1 (Supply 2)

305

L2 (Supply 2)

306

L3 (Supply 2)

PE

Protective Earth

502

Fire Detector

583

Fire Detector

583

Smoke Detector

584

Smoke Detector

502

Remote On/Off

522

Remote On/Off

Condensate Pump Supply (230V)

N (3*)

Condensate Pump Supply (230V)

534

Condensate Pump High Level Alarm

535

Condensate Pump High Level Alarm

609

Flood Detection Tape / Probe

610

Flood Detection Tape / Probe

810

Supply Air Temperature Sensor

811

Supply Air Temperature Sensor

560

Non-Critical Alarm N/O

561

Non-Critical Alarm Common

563

Critical Alarm N/O

564

Critical Alarm Common

565

Critical Alarm N/C

881

BMS Connection

882

BMS Connection

883

BMS Connection

CLCL

SD

301

Technical

N1

*For 220V/3PH NO neutral units the Neutral connection is replaced with a live phase.

SmartCool 6 - 200kW Chilled Water Technical Manual 7674716 V1.1.0_04_2014

191

SmartCool 6 - 200kW

Precision Air Conditioning

After Sales
Warranty

All Airedale products or parts (non consumable) supplied for installation within the UK mainland and commissioned by
an Airedale engineer, carry a full Parts & Labour warranty for a period of 12 months from the date of commissioning or
18 months from the date of despatch, whichever is the sooner.
Parts or Equipment supplied by Airedale for installation within the UK or for Export that are properly commissioned in
accordance with Airedale standards and specification, not commissioned by an Airedale engineer; carry a 12 month
warranty on non consumable Parts only from the date of commissioning or 18 months from the date of despatch,
whichever is the sooner.
Parts or equipment installed or commissioned not to acceptable Airedale standards or specification invalidate all
warranty.

Warranty is only valid in the event that

In the period between delivery and commissioning the equipment: is properly protected & serviced as per the Airedale
installation & maintenance manual provided where applicable the glycol content is maintained to the correct level.
In the event of a problem being reported and once warranty is confirmed as valid under the given installation and
operating conditions, the Company will provide the appropriate warranty coverage (as detailed above) attributable to the
rectification of any affected Airedale equipment supplied (excluding costs for any specialist access or lifting equipment
that must be ordered by the customer).
Any spare part supplied by Airedale under warranty shall be warranted for the unexpired period of the warranty or 3
months from delivery, whichever period is the longer.
To be read in conjunction with the Airedale Conditions of Sale - Warranty and Warranty Procedure, available upon
request.

Procedure

When a component part fails, a replacement part should be obtained through our Spares department. If the part is
considered to be under warranty, the following details are required to process this requirement. Full description of part
required, including Airedales part number, if known. The original equipment serial number. An appropriate purchase
order number.
A spares order will be raised under our warranty system and the replacement part will be despatched, usually within 24
hours should they be in stock. When replaced, the faulty part must be returned to Airedale with a suitably completed and
securely attached Faulty Component Return (FCR) tag. FCR tags are available from Airedale and supplied with each
Warranty order.
On receipt of the faulty part, suitably tagged, Airedale will pass to its Warranty department, where it will be fully
inspected and tested in order to identify the reason for failure, identifying at the same time whether warranty is justified
or not.
On completion of the investigation of the returned part, a full Report on Goods Returned will be issued. On occasion
the release of this complete report may be delayed as component manufacturers become involved in the investigation.
When warranty is allowed, a credit against the Warranty invoice will be raised. Should warranty be refused the Warranty
invoice becomes payable on normal terms.

Exclusions

Warranty may be refused for the following reasons.


Misapplication of product or component
Incorrect site installation
Incomplete commissioning documentation
Inadequate site installation
Inadequate site maintenance
Damage caused by mishandling
Replaced part being returned damaged without explanation
Unnecessary delays incurred in return of defective component

Returns analysis

All faulty components returned under warranty are analysed on a monthly basis as a means of verifying component and
product reliability as well as supplier performance. It is important that all component failures are reported correctly.

192

SmartCool Technical Manual 7525371 V1.1.0_04_2014

Precision Air Conditioning

SmartCool 6 - 200kW

SmartCool Technical Manual 7525371 V1.1.0_04_2014

193

Head Office
Airedale International Air Conditioning Ltd
Leeds Road
Rawdon
Leeds LS19 6JY

Tel: +44 (0) 113 2391000


Fax:+44 (0) 113 2507219
E-mail enquiries@airedale.com
Web www.airedale.com

TM_SMARTCOOL_6_200kW_7674716_1.1.0_04_2014

You might also like