Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Fluke 360

AC Leakage Current Clamp Meter

Technical Data

The Fluke 360, a rugged and accurate


solution for leakage current measurement
Ideally designed for non-invasive checks of insulation
condition, the Fluke 360 allows you to perform tests without
powering down the installation or disconnecting equipment saving you time, without compromising on quality or safety.
The unique jaw design of the Fluke 360 eliminates the
influence of adjacent current conductors, and minimizes the
effects of external magnetic fields, even at low currents.
This allows you to perform accurate and reliable tests in
todays crowded electrical environments. The tough and
high-quality clamp design of the Fluke 360 guarantees high
stability for long-term repeatability.

Measurement of leakage current with 3 mA range and 1 A of


resolution, for accurate monitoring of insulation erosion

Broad range of measurement, from 1 A up to 60 A, for all


installation needs

Advanced shielding to ensure accurate results when measuring near

other conductors
The high durability clamp construction can withstand over 50,000
operations - added ruggedness that extends the life of your clamp.
Easy-to-carry, pocket-sized clamp with wide 40 mm (1.5 in) jaw size
Handy Display-Hold button for capturing readings in hard-
to-reach places
Auto power-off, with warning buzzer, saves battery life
Conformance to IEC1010 and EMC standard for confident
measurements
Meets all of the applications and performance classes in safety
standard VDE0404-4 and VDE0702 for leakage current and
differential current measurement of electrical appliances

Special Features
IEC 61010 and EMC Conformance

High Accuracy

IEC 61010 safety features including a tactile barrier and


special jaw design provide the user with confidence
when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability
through reduced susceptibility to electromagnetic interference.
The Fluke 360 also meets the latest safety standard
VDE0404-4 and the new VDE0702 requirements.

Advanced jaw design means that the Fluke 360 accuracy


is little affected by external magnetic fields even at low
currents. Typical external current rejection is 200,000:1.

General Specification
Method of detection

Mean value

Display

Digital display: 3200 counts


Bar-graph display: 32 segments, LCD

Measurement cycle

2 times/second (Digital display), 12 times/second (Bar-graph display)

Range switching

Auto-range

Ambient temperature and humidity

0 C to 50 C, 80 % RH or less (no condensation)

Temperature coefficient

0.05 % of range/C or less (within the ranges of 0 C to 18 C and


28 C to 50 C for measurement of 0-50 A)

Influence of external magnetic field

0.0005 % typical 1 (on current value of adjacent cable)

Influence of conductor position

Within accuracy

Circuit voltage

300 Vrms

Safety standard

EN 61010-1, EN 61010-2-032. 300 V CAT II, Pollution Degree 2

Withstanding voltage

3.7 kV ac for one minute

Battery type

1 x 3 V Lithium battery (button cell) CR2032

Battery life

Approx. 90 hours (when continuously used)

Auto power-off

Approx. 10 minutes

Diameter of measurable conductor

40 mm max.

Weight

200 g (441 lb)

Dimension

176 mm x 70 mm x 25 mm (6.9 in x 2.8 in x 1 in)

Operating altitude

2000 m (6,562 ft)

Electrical Specification

Specifications at 23 5 C. 80 % RH max
Accuracy: (% rdg + dgt) = (% readout + value of least significant digit)

AC Current Measurement
Measuring range

Resolution

3 mA

0.001 mA

30 mA

0.01 mA

30 A

0.01 A

60 A

0.1 A

Accuracy

Max Permissible current

1%+5
1 % + 5 (0~50 A)
5 % + 5 (50~60 A)

Mean value detection and rms-value calibration.


Accuracy specified at 50/60 Hz
Frequency range 15 Hz to 150 Hz
 Fluke Corporation Fluke 360 AC Leakage Current Clamp Meter

60 A rms

Fluke. Keeping your world



up and running.
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
2006 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 12/2006 Pub_ID: 11201-eng