Professional Documents
Culture Documents
Fluke 115: Multimeter
Fluke 115: Multimeter
Multimeter
Technical Data
Features include:
Resistance, continuity, frequency, capacitance, and diode test Measures 10 A (20 A overload for 30 seconds) Large white LED backlight to work in poorly lit areas Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak) True-rms for accurate measurements on non-linear loads Min/Max/Average with elapsed time to record signal CAT III 600 V safety rated
General specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ( [ % of reading ] + [ counts ] )
Maximum voltage between any terminal and earth ground Surge protection Fuse for A input 600 V 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 11 A, 1000 V FAST Fuse (Fluke PN 803293) Digital: 6,000 counts, updates 4/sec 33 segments, updates 32/sec -10 C to + 50 C -40 C to + 60 C 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 400 hours typical, without backlight
fluctuations
Actual size
Display Bar graph Operating temperature Storage temperature Battery Battery life
N10140
Accuracy specifications
Measurement DC millivolts DC volts Range 600.0 mV 6.000 V 60.00 V 600.0 V Auto volts AC millivolts1 true-rms AC volts1 true-rms 600.0 V 600.0 mV 6.000 V 60.00 V 600.0 V Continuity Ohms 600 600.0 6.000 k 60.00 k 600.0 k 6.000 M 40.00 M Diode test Capacitance 2.000 V 1000 nF 10.00 F 100.0 F 9999 F 100 F to 1000 F > 1000 F Lo-Z capacitance AC amps true-rms (45 Hz to 500 Hz) 1 nF to 500 F 6.000 A 10.00 A 6.000 A 10.00 A Hz (V or A input)2 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz 0.001 A 0.01 A 0.001 A 0.01 A 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 % + 2 Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M 0.001 V 1 nF 0.01 F 0.1 F 1 F 1.9 % + 2 5 % + 20 10 % + 2 typical 1.5 % + 3 1.9 % + 2 5%+2 0.9 % + 2 0.9 % + 1 Beeper on < 20 off > 250 ; detects opens or shorts of 500 s or longer. 0.9 % + 2 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 0.5 % + 2 Accuracy ([% of reading] + [counts]) 0.5 % + 2
Ordering information
Fluke-115 Multimeter
Included TL75 Test leads, holster, Users manual and 9 V battery (installed).
Notes: 1 All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac coupled and ac mV is dc coupled. 2 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
2 Fluke Corporation
115 Multimeter