Electricians Multimeter
with Non-Contact Voltage
Technical Data
Features include:
VoltAlert technology for non-contact voltage detection AutoVolt automatic ac/dc voltage selection LoZ: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True-rms for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30 seconds) Resistance, continuity, frequency and capacitance Min/Max/Average to record signal fluctuations Compatible with optional magnetic hanger (ToolPak) for
hands free operation CAT III 600 V safety rated
General specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ( [ % of reading ] + [ counts ] )
Maximum voltage between any terminal and earth ground Surge protection Fuse for A input Display Bar graph Operating temperature Storage temperature Battery
R
600 V 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 11 A, 1000 V FAST Fuse (Fluke PN 803293) Digital: 6,000 counts, updates 4/sec 33 segments, updates 32/sec -10 C to + 50 C -40 C to + 60 C 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 400 hours typical, without backlight
Actual size
N10140
Battery life
Accuracy specifications
Measurement DC millivolts DC volts Range 600.0 mV 6.000 V 60.00 V 600.0 V Auto volts AC millivolts1 true-rms AC volts1 true-rms 600.0 V 600.0 mV 6.000 V 60.00 V 600.0 V Continuity Ohms 600 600.0 6.000 k 60.00 k 600.0 k 6.000 M 40.00 M Diode test Capacitance 2.000 V 1000 nF 10.00 F 100.0 F 9999 F 100 F to 1000 F > 1000 F Lo-Z capacitance AC amps true-rms (45 Hz to 500 Hz) 1 nF to 500 F 6.000 A 10.00 A 6.000 A 10.00 A Hz (V or A input)2 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz 0.001 A 0.01 A 0.001 A 0.01 A 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 % + 2 Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M 0.001 V 1 nF 0.01 F 0.1 F 1 F 1.9 % + 2 5 % + 20 10 % + 2 typical 1.5 % + 3 1.9 % + 2 1.5 % + 2 0.9 % + 2 0.9 % + 1 Beeper on < 20 off > 250 ; detects opens or shorts of 500 s or longer. 0.9 % + 2 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 0.5 % + 2 Accuracy ([% of reading] + [counts]) 0.5 % + 2
Ordering information
Fluke-117 Electricians Multimeter with Non-Contact Voltage
Included TL75 Test leads, holster, Users manual and 9 V battery (installed).
Notes: 1 All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display nonzero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. 2 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.