IS5026 Operating Instruction
IS5026 Operating Instruction
Inductive sensors
This info card is to be regarded as a supplement to the main position sensors catalogue and to the individual data sheets. For further information and contact addresses please visit our homepage at www.
ifm.com.
Hysteresis
Short-circuit protection
Standard target
Connection
Housing
Downstream electronics
Capacitor
5:
6:
7:
8:
10 / 2014
1 D 2226 / 04
Leakage current
Current for the internal supply of 2-wire units; also flows through the
load when the output is blocked.
Switching frequency
Pot core
Coil
Alternating electromagnetic field = active zone
Target = electrically conductive material
Important Glossary
Active zone / active face
Area above the sensing face in which the sensor reacts to the approach of the target.
Output function
Normally open:
IEC 60947-5-2
Repeatability
Sn
2
The time the sensor needs to be ready for operation after application
of the operating voltage (in the millisecond range).
Operating voltage
The voltage range in which the sensor functions reliably. A stabilised and smoothed direct voltage should be used! Take into account
residual ripple!
Utilisation category
Current consumption
Degree of soiling
+ 10 %
- 10 %
2a
1:
2:
3:
4:
Product standard
Sn
Sr
Sumax
+ 10 %
- 10 %
Sumin
Sa
UK
Info card
Tips on flush and non-flush mounting in metal
Inductive sensors
Correction factors
Non-flush:
Sr [%]
2x
100
Sn
V2A
50
Ms Al
Cu
* Standard target
Influence of the target size
UK
Sr [%]
100
Installation instructions rectangular designs
50
Flush:
0
0,2
0,5
Non-flush:
1,0
h
h
Lateral approach and ranges (valid for structural steel, e.g. S235JR)
2xa
1,5
xa
a
2xa
Sn
[6
h = any
Q
6
1,5
xa
2xa
2xa
i
i
Distance to the background
Recommended target distance
Recommended degree of coverage of the sensing
face
Recommended target size
If the required clear space is not observed for non-flush units, the sensor is predamped. This may lead
to permanent switching.
Possibly deviating installation instructions for rectangular units with increased sensing range Notes
on mounting and operation.
Info card
Parallel connection (OR)
Inductive sensors
+UB
Minimum clearance for installing units of the same type (side-by-side installation)
Applies to cylindrical and rectangular sensors.
Flush:
Non-flush:
2x
0V
Sn
UK
Sn
Positive switching
Configuration of cables
and connectors
Connection systems
+UB / L1
+UB
0V / N
Two-wire technology
(negative or positive switching)
+UB
0V
0V
3-wire technology
(negative or positive switching)
4-wire technology
(positive switching, normally closed
and normally open)
+UB / L1
U1
Un
UL
0V
0V / N
Sensor n
Cable
BN
BU
Terminal chamber
1/3
2/4
Output
BK
Pin 4: BK
Pin 1: BN
US-100 plug
Pin 1 / BN
Pin 3 / BU
Pin 2 / WH
Pin 4 / BK
Pin 3: BU
Pin 2: WH
For the cable and the pin configuration as well as the unit data of special versions please refer to the wiring diagrams in our main catalogue
for position sensors.