Catalogue DC-UPS - 2 PDF
Catalogue DC-UPS - 2 PDF
Catalogue DC-UPS - 2 PDF
DC-Ups
Integrated Electronic Solutions
Connect
The new communication platform for ADELSYSTEM devices allows the connection of all components in a simple but very powerful way. A single
communication protocol based on MODbus-RTU
or CANbus technology. You can select any of
the two buses depending on the application. It
allows to communicate with all the accessories
provided by ADELSYSTEM and to develop an
independent system for electrical continuity. At
the same time, it allows monitoring and control
all parameters in the system, even from the
other side of the world, by means of application
tools on the cloud.
ADELSYSTEM allows you to implement very simple but sophisticated monitoring and control for
your energy system and opens your mind to new
ways to approach your applications.
Monitoring Software
Power View System is a PC-based software developed to
monitor in real time every important parameter of the DCUPS/battery system. A simple and intuitive users interface
allows monitoring of battery parameters, load output,
temperature sensor, mains presence and all alarm and
diagnostic flags. All feature are displayed in a single screen.
5 Power Bus
Multimediality
1
Ethernet
Cloud
24 V
PLC
Switch gear
Sensors
Actuators
Security systems
Load
230 Vac
TV color
Coffee
Light
Actuators
9
6
10
9 Inverter
8 Load
The DC-UPS unit mission is to always keep the load
supplied. The Load Output is the source of power for the
whole electric system and has been designed to perform
this duty under the most critical conditions, no matter if
during stand-by or back-up modes.
Power continuity
DC-UPS = Power Supply +
Battery Charger + Back Up
module
Double Output, Optimized Power Management. Thanks to the DC-UPS units,
it will be possible to smart-manage
available power. It will be automatically
allocated between load and battery.
Supplying power to the load is the first
priority of the unit; thus it is not necessary to double the power, and also the
power available for the battery will go to
the load if the load requires so.
Output Load:
Power Boost:
12, 24, 48
In x 2 Continuos
In x 3 max 4 sec.
Battery
Load
Load
Input ity
flexibil
Load
In
In
I batt
In
I batt
> 4 min.
I batt
max. 4 sec.
Time buffering
Adjustable maximum
battery charging current
c
Vd
12
Accessories
Clear definition of each system operation, via LED indications and Relay
contact:
+ Batt.
Battery Start UP cable.
Display Signals by LED
Input Main On Off
Battery Fault
Low battery (capacity less than 30%)
Type of Battery charge mode
Help through blinking code the
diagnosis of the system
AUX 2
Driver Contact
AUX 3
Battery care
One device for all battery types
All devices are suitable to charge most
batteries types thank to user selectable
charging curves. They can charge open
lead acid, sealed lead acid, Gel, Ni-Cd,
Ni-MH, Li Ion batteries. It is possible
to change or add other charging curves
connecting the device to a portable PC.
Charging mode is then completely
automatic.
Open Lead Acid (factory preset):
Trickle 2.23 V
Boost 2.40 V
Sealed Lead Acid (1):
Trickle 2.25 V
Boost 2.40 V
Recovery
charge
(blink 5/sec.)
Charge
Absorbtion
Gel:
Trickle 2.30 V
Boost 2.40 V
Boost
These devices are completely automatic and can charge any kind of
battery using factory pre-set charging
curves suitable to the most common
accumulator technologies: open lead
acid, sealed lead acid, lead gel, Ni-Cd
and Ni-MH. These devices are very
flexible and can be customized to
meet the needs of the user and the
requirements of the application. After
the installation, it is possible to carry
out functional software updates just
using any laptop computer. Doing so,
your system can always be updated to
changing requirements.
The Battery Care concept is base on
algorithms that implement rapid and
automatic charging, battery charge
optimization during time, flat batteries recovery and real time diagnostic
during installation and operation. Battery faults such as battery sulfated,
elements in short circuit, accidental
reverse polarity connection can easily
be detected, identified and removed.
The All in one Series meet the highest
standards of quality and insure high
reliability, with MTBF values up to
300.000 hours.
Trickle /
Float Charge
(blink 1/sec.)
N PE
battery voltage
Boost or float charge.
circuit
4 flashes = Overload
5 flashes = Battery to be replaced
General data
Battery Life Test
Diagnostic checks
Temperature Compensation
In special application like fire fighting
equipment, you can recharge the
battery also with the temperature
compensation charging function, for
the best condition of your battery in
the temperature fluctuation.
Technology
Switching technology
Adelsystem has a 25 year experience
in design of advanced stabilized
switching technology power supplies.
A power supply/battery charger unit
based on this technology is much
more efficient.
Element in
Short Circuit
Norms
In Conformity to:
IEC/EN 60335-2-29 Battery chargers;
EN60950 / UL1950;
Electrical safety EN54-4 Fire
Detection and fire alarm systems;
EMC Directive;
DIN 41773 (Charging cycle).
DC UPS
In Vac
12 Vdc
110 - 230 Vac
Battery
Mains or Backup
Battery Low or
Battery Replacement
Output
CBI123A
12Vdc - 3A - 36W
CBI126A
12Vdc - 6A - 72W
CBI1210A
12Vdc - 10A - 120W
CBI1235A
12Vdc - 35A - 420W
INPUT
DATA
90 - 305 Vac
90 - 305 Vac
90 - 305 Vac
90 - 135 Vac
180 - 305 Vac
Frequency
47 - 63 Hz 6%
47 - 63 Hz 6%
47 - 63 Hz 6%
47 - 63 Hz 6%
OUTPUT
DATA
Out load
Output Vdc / IN
12Vdc - 3A
12Vdc - 6A
12Vdc - 10A
12Vdc - 35A
90%
90%
90%
> 91%
10 - 14.4Vdc
10 - 14.4Vdc
10 - 14.4Vdc
10 - 14.4Vdc
1.1 x In A 5%
1.1 x In A 5%
1.1 x In A 5%
1.1 x In A 5%
3A
6A
10A
35A
6A
12A
20A
70A
9A max
18A max
30A max
105A max
6A max
12A max
20A max
70A max
Time Buffering
14.4Vdc
14.4Vdc
14.4Vdc
14.4Vdc
15h
15h
15h
15h
1min.
1min.
1min.
1min.
13.8Vdc
13.8Vdc
13.8Vdc
13.8Vdc
20 100 % / Ibatt
20 100 % / Ibatt
20 100 % / Ibatt
10 100 % / Ibatt
BATTERY CHARGER
OUTPUT
LOAD
OUTPUT
Model
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel;
NiCd 1.5V/cell (10 elem.) trickle (Imax 10%)
Boost / Trickle
Boost / Trickle
AUXILIARY SIGNAL
OUTPUT* OUTPUT
FOR: (RELAY)
CLIMATIC
DATA
by ext. Probe
by ext. Probe
by ext. Probe
by ext. Probe
UPS active
-25 +70C
-25 +70C
-25 +70C
-25 +70C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
-40 +85C
-40 +85C
-40 +85C
-40 +85C
95% to 25C
95% to 25C
95% to 25C
95% to 25C
Cooling
Auto Convection
Auto Convection
Auto Convection
Auto Convection
3000Vac
3000Vac
3000Vac
3000Vac
1605Vac
1605Vac
1605Vac
1605Vac
500Vac
500Vac
500Vac
500Vac
IP 20
IP 20
IP 20
IP 20
Dimension (w-h-d)
65x115x135
65x115x135
65x115x135
GENERAL
DATA
150x115x135
CE
Boost / Trickle
Humidity at 25 C
OPTIONAL
Boost / Trickle
IUoU, Automatic, 4 stage
Characteristic Curve
24 Vdc
48 Vdc
CBI243A
24Vdc - 3A - 72W
CBI245A
24Vdc - 5A - 120W
CBI2410A
24Vdc - 10A - 240W
CBI2420A
24Vdc - 20A - 500W
CBI485A
48Vdc - 5A - 240W
CBI4810A
48Vdc - 10A - 500W
90 - 305 Vac
90 - 305 Vac
90 - 135 Vac
180 - 305 Vac
90 - 135 Vac
180 - 305 Vac
90 - 135 Vac
180 - 305 Vac
90 - 135 Vac
180 - 305 Vac
47 - 63 Hz 6%
47 - 63 Hz 6%
47 - 63 Hz 6%
47 - 63 Hz 6%
47 - 63 Hz 6%
47 - 63 Hz 6%
24Vdc - 3A
24Vdc - 5A
24Vdc - 10A
24Vdc - 20A
48Vdc - 5A
48Vdc - 10A
90%
90%
83%
> 91%
83%
> 91%
22 - 28.8Vdc
22 - 28.8Vdc
22 - 28.8Vdc
22 - 28.8Vdc
44 - 57.6Vdc
44 - 57.6Vdc
1.1 x In A 5%
1.1 x In A 5%
1.1 x In A 5%
1.1 x In A 5%
1.1 x In A 5%
1.1 x In A 5%
3A
5A
10A
20A
5A
10A
6A
10A
20A
40A
10A
20A
9A max
15A max
30A max
60A max
15A max
30A max
6A max
10A max
20A max
40A max
10A max
20A max
CBI2410A/S
CBI485A/S
28.8Vdc
28.8Vdc
28.8Vdc
28.8Vdc
57.6
57.6
15h
15h
15h
15h
15h
15h
1min.
1min.
1min.
1min.
1min.
1min.
27.6Vdc
27.6Vdc
27.6Vdc
27.6Vdc
55.2Vdc
55.2Vdc
20 100 % / Ibatt
20 100 % / Ibatt
20 100 % / Ibatt
10 100 % / Ibatt
20 100 % / Ibatt
10 100 % / Ibatt
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel;
NiCd 1.5V/cell trickle (Imax 10%)
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
Boost / Trickle
by ext. Probe
by ext. Probe
by ext. Probe
by ext. Probe
by ext. Probe
by ext. Probe
-25 +70C
-25 +70C
-25 +70C
-25 +70C
-25 +70C
-25 +70C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
-40 +85C
-40 +85C
-40 +85C
-40 +85C
-40 +85C
-40 +85C
95% to 25C
95% to 25C
95% to 25C
95% to 25C
95% to 25C
95% to 25C
Auto Convection
Auto Convection
Auto Convection
Auto Convection
Auto Convection
Auto Convection
3000Vac
3000Vac
3000Vac
3000Vac
3000Vac
3000Vac
1605Vac
1605Vac
1605Vac
1605Vac
1605Vac
1605Vac
500Vac
500Vac
500Vac
500Vac
500Vac
500Vac
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
65x115x135
65x115x135
100x115x135
150x115x135
100x115x135
150x115x135
CE
CE
CE
CE
DC UPS
In Vac
36/48 Vdc
12/24 Vdc
110-230 Vac
110-230 Vac
12/24 Vdc
230-400-500 Vac
Battery
Mains or Backup
Battery Low or
Battery Replacement
CBI2803648A
36/48Vdc - 270W
CBI2801224A
12/24Vdc - 270W
CBI2801224B
12/24Vdc - 270W
INPUT
DATA
90 - 135 Vac
180 - 305 Vac
90 - 135 Vac
180 - 305 Vac
Frequency
47 - 63 Hz 6%
47 - 63 Hz 6%
47 - 63 Hz 6%
OUTPUT
DATA
Out load
Output Vdc / IN
36 / 48Vdc - 270 W
12 / 24Vdc - 270 W
12 / 24Vdc - 270 W
> 91%
> 91%
> 91%
33 - 43,2Vdc /
44 - 57.6Vdc
11 - 14.4Vdc /
22 - 28.8Vdc
11 - 14.4Vdc /
22 - 28.8Vdc
1.1 x In A 5%
1.1 x In A 5%
1.1 x In A 5%
7A (36V) / 5A (48V)
Max current output load: (Back Up) Iload (4sec.) 14A (36V) / 10A (48V)
Time Buffering
43.2Vdc (36V) /
57.6Vdc (48V)
15h
15h
15h
1min.
1min.
1min.
41.4Vdc (36V) /
55.2Vdc (48V)
10 100 % / Ibatt
10 100 % / Ibatt
10 100 % / Ibatt
Model
BATTERY CHARGER
OUTPUT
LOAD
OUTPUT
Output
2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel;
NiCd 1.5V/cell (20 elem.) trickle (Imax 10%)
Boost / Trickle
Boost / Trickle
AUXILIARY SIGNAL
OUTPUT* OUTPUT
FOR: (RELAY)
CLIMATIC
DATA
by ext. Probe
by ext. Probe
by ext. Probe
UPS active
-25 +70C
-25 +70C
-25 +70C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
> 50 -2.5%(In) / C
-40 +85C
-40 +85C
-40 +85C
95% to 25C
95% to 25C
95% to 25C
Cooling
Auto Convection
Auto Convection
Auto Convection
3000Vac
3000Vac
3000Vac
1605Vac
1605Vac
1605Vac
500Vac
500Vac
500Vac
IP 20
IP 20
IP 20
Dimension (w-h-d)
115x115x135
115x115x135
115x115x135
CE
CE
CE
OPTIONAL
GENERAL
DATA
Humidity at 25 C
10
Boost / Trickle
Characteristic Curve
Battery modules
VRLA
12 Vdc
BATT 123
12V - 3.2Ah
BATT 127
12V - 7.2Ah
0.80 A
1.70 A
0.30 A
0.80 A
1.70 A
Short-circuit protection
Protection fuse
25 A
25 A
25 A
25 A
25 A
25 A
+5 +40 C
+5 +40 C
+5 +40 C
+5 +40 C
+5 +40 C
+5 +40 C
-20 +50 C
-20 +50 C
-20 +50 C
-20 +50 C
-20 +50 C
-20 +50 C
Model
Output
FEATURE
24 Vdc
BATT 1.2 Ah
24V - 1.2Ah
BATT 7.2 Ah
24V - 7.2Ah
BATT 12 Ah
24V - 12Ah
3A
Self-discharge rate
GENERIC
DATA
BATT 3 Ah
24V - 3.2Ah
Dimension (w-h-d)
105 x 175 x 90
105 x 175x120
170 x 100 x 80
170 x 140 x 90
170 x 155x120
235 x 155x120
Weight
0.7 Kg approx
1.1 Kg approx
1.55Kg approx
3 Kg approx
5.5 Kg approx
9 Kg
Protection class
IP20
IP20
IP20
IP20
IP20
IP20
Small VRLA
24 Vdc
BAT1.2 VRLA
24V - 1.2Ah
BAT3.4 VRLA
24V - 3.2Ah
0.30 A
0.80 A
1.70 A
Short-circuit protection
Protection fuse
25 A
25 A
25 A
25 A
Output current
max. 25 A
max. 25 A
max. 25 A
max. 25 A
Model
OUTPUT INPUT
DATA DATA
GENERIC
DATA
Output
Mounting position
BAT7.2 VRLA
24V - 7.2Ah
0 +40 C
0 +40 C
0 +40 C
0 +40 C
-20 +50 C
-20 +50 C
-20 +50 C
-20 +50 C
Self-discharge rate
Dimension (w-h-d)
62 x 175 x 120
82 x 200 x 160
210 x 210x210
Weight
1.5Kg approx
3 Kg approx
5.5 Kg approx.
9 Kg
Protection class
IP20
IP20
IP20
IP20
Battery type
1.2 Ah
3.2 Ah
7.2 Ah
12 Ah
Battery type
1.2 Ah
3.2 Ah
7.2 Ah
12 Ah
Load 1.5 A
20
60
200
400
Load 10 A
20
45
Load 3 A
30
120
240
Load 12 A
12
30
Load 5 A
15
55
100
Load 15 A
20
Load 7.5 A
10
30
60
Load 20 A
13
BUFFERING
(MINUTE) TIME
BUFFERING
(MINUTE) TIME
BAT12 VRLA
24V - 12Ah
11
Product range
D-Flex
CB
Dc/Dc converter
Interfaces
BM
Dc / Dc Converter, step
Up and Step down. Input
- Output isolated, low
voltage. With or without
DIN Rail.
Auxiliary
module
Power supply
low input voltage
Switching power suppy
for direct connection to
secondary transformer In
24 Vac Out 12-24-48 Vdc
Watt: 25-460.
www.adelsystem.com
ADELSYSTEM The copying, distribution and utilization of this document as well as the communication of its contents
to others without expressed authorization is prohibited. All data in this publication is subject to change without information.
Flex
DC UPS
All In One