VLT Automation Drive FC 360 PDF
VLT Automation Drive FC 360 PDF
Selection guide
VLT AutomationDrive FC 360
www.danfoss.com/FC360
PERFORMANCE,
RELIABILITY AND
SPEED
Increase quality and efficiency with
energy efficient, user friendly control of
motors from 0.37 to 75 kW.
Built on the success of the tried and tested VLT platform that
Danfoss developed and launched in the 1960s, the VLT AutomationDrive FC 360 shares the same technical heritage as the
popular and versatile VLT AutomationDrive FC 300 series.
Developed to meet a general purpose operation prole the
drive lacks the expandability of its larger sibling, but still delivers
powerful performance out of the box.
Due to the fact that all Danfoss frequency converters follow the
same basic design and operating principle, existing owners and
users of VLT drives will instantly feel at home when operating
the VLT AutomationDrive FC 360.
The VLT AutomationDrive FC 360 is a dedicated industry drive ,
designed for OEMs, that provides precise and ecient motor
control in a wide range of industrial applications.
Space in installations
Time in setup
Eort in daily maintenance.
Maximize productivity
IP20 standard protection and an easy to use control
panel saves valuable time in commissioning and
maintainance, and enables owners to maximize
uptime and save energy..
HIGH RELIABILITY
Coated Printed Circuit Boards
High level 3C3 Printed Circuit Board
(PCB) coating as standard provides
high reliability in harsh environments
to prevent failures and downtime. The
lifetime of the drive is also increased as
a result of the IEC 60721-3-3 conformal
coating.
COATED PCB
EASY CLEANING
DISPLAY
ENCLOSURE
Optimized for
industrial applications
Extruders
Escalators
Winders
Material Handling
Palletizer
Conveyor
Draw Bench
Textile Machinery
Hoist
Air Compressor
Printing & Dyeing
Glass Production Line
Centrifuge separators
Pumps
Fans
HIGH PERFORMANCE
CONTROLLER
VLT AutomationDrive
FC 360 has an advanced
controller with high speed
response making high-end,
complicated applications
easy.
SPEED
PM motor control
The FC 360 can provide highly ecient
permanent magnet (PM) motor control
in open loop under VVC+ mode in
motors up to 22kW. Using Automatic
Motor Adaptation (AMA) the drive
adapts to the specic characteristics of
the permanent magnet motor.
FEATURES DESIGNED TO
MEET INDUSTRIAL NEEDS
The VLT AutomationDrive FC 360 is designed to provide
maximum uptime and reliability in a wide range of environments.
Center Winder
FC 360 supports center winder
functionality, eliminating the need for
a special module in the programmable
logic control (PLC).
3
1
4
DESIGNED FOR A WIDE
RANGE OF POWER
SUPPLY CONDITIONS
VLT AutomationDrive
FC 360 can operate at
-15% of supply voltage
8
Removable fan
Display options
- Graphic LCP
- Enhanced numeric LCP
- Blind cover
RFI Swtich
9
7
SPECIFICATIONS
(Basic unit without extensions)
Analogue output
380480 V -15%/+10%
50/60 Hz 5%
Programmable
analogue outputs
> 0.98
Current range at
analogue output
0/4 20 mA
Supply frequency
Harmonic disturbance
Meets EN 61000-3-12
Output frequency
0-500 Hz
0-200 Hz under VVC+ Mode
Switching on output
Ramp times
Unlimited
0.05-3600 sec
2 (Terminal 27,29)
Logic
PNP or NPN
Voltage level
0 24 V DC
28 V DC
Approx. 4 k
Control card
RS485 interface
Up to 115 kBaud
15 mA
100 mA
Relay output
Programmable relay outputs
250V AC, 3 A
250V AC, 3 A
Enclosure
2
Voltage or current
IP20
Vibration test
Max. relative humidity
1.0 g
5-95% (IEC 60721-3-3; Class 3K3 (noncondensing) during operation
Voltage level
0 to +10 V
(scaleable)
Ambient temperature
Current level
0/4 to 20 mA (scaleable)
Programmable pulse/
encoder inputs
Voltage level
Pulse input accuracy
(0.1 1 kHz)
Encoder input accuracy
2/1
0 24 V DC (PNP positive logic)
Max. error: 0.1% of full scale
4Hz-32kHz
Aggressive environment
Class 3C3
Fieldbus communication
Pulse/encoder inputs
10
Surroundings/external
Analog inputs
Modes
Accuracy on analogue
output
500
1 ms
Analogue inputs
2
0 24 V DC
40 mA
4Hz to 32 kHz
Max. error: 0.1% of full scale
Standard built-in
FC Protocol
Modbus RTU
PROFIBUS
CONNECTION EXAMPLES
The numbers represent the terminals on the drive
3 Phase
power
input
91 (L1)
92 (L2)
93 (L3)
95 PE
(U) 96
(V) 97
(W) 98
(PE) 99
Switch Mode
Power Supply
10Vdc
24Vdc
15mA
100mA
+10V DC
50 (+10 V OUT)
0/-10V DC 0/4-20 mA
53 (A IN)
0/-10V DC 0/4-20 mA
54 (A IN)
130BC438.11
3)
Motor
(-UDC) 88
(+UDC) 89
Brake
resistor
(BR) 81
relay1
03
02
55 (COM A IN)
01
relay 2 2)
12 (+24V OUT)
06
P 5-00
05
18 (D IN)
24V (NPN)
0V (PNP)
19 (D IN)
24V (NPN)
0V (PNP)
20
(COM D IN)
27
(D IN/OUT)
(A OUT) 45
24V (NPN)
0V (PNP)
(D IN/OUT)
24V
5V
24V (NPN)
0V (PNP)
S801
0V
1
2
3
4
5
Analog Output
0/4-20 mA
ON=Terminated
OFF=Open
ON
1 2
0V
240V AC, 2A
04
(A OUT) 42
24V
29
240V AC, 2A
32 (D IN)
24V (NPN)
0V (PNP)
33 (D IN)
24V (NPN)
0V (PNP)
31 (D IN)
24V (NPN)
0V (PNP)
RS-485
Interface
0V
(N RS-485) 69
RS-485
(P RS-485) 68
(COM RS-485) 61
(PNP) = Source
(NPN) = Sink
11
1.1
1.6
2.1
2.8
3.4
4.8
6.3
8.2
11
14
21
27
34
40
52
65
80
96
124
[1]
FC-360
[1] Application
360
0.37-2.2
3.0-5.5
Dimensions
[mm]
12
J4
7.5
11-15
B
b
J5
J6
J7
18.5-22
30-45
55-75
J2
J3
J4
Height A
210
272.5
272.5
317.5
410
515
550
Width B
75
90
115
133
150
233
308
Depth C
(with option B)
168 (181)
168 (181)
168 (181)
245 (258)
245 (258)
241
323
198
260
260
297.5
390
495
521
b
Mounting screw
60
70
90
105
120
200
270
M4
M5
M5
M6
M6
M8
M8
J5
J6
Mounting holes
J7
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
HK37
HK55
HK75
H1K1
H1K5
H2K2
H3K0
H4K0
H5K5
H7K5
H11K/
Q11K See ratings data on page 11
H15K/ for power ratings
Q15K
H18K/
Q18K
H22K/
Q22K
H30K/
Q30K
H37K/
Q37K
H45K/
Q45K
H55K/
Q55K
H75K/
Q75K
J3
J1
[2]
J2
130BC449.10
1.2
1.7
2.2
3.0
3.7
5.3
7.2
9.0
12
15.5
23
31
37
42.5
61
73
90
106
147
J1
440-480V
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18
22
30
37
45
55
75
Frame size
380-480 V
A
a
kW
HK37
HK55
HK75
H1K1
H1K5
H2K2
H3K0
H4K0
H5K5
H7K5
H11K/Q11K
H15K/Q15K
H18K/Q18K
H22K/Q22K
H30K/Q30K
H37K/Q37K
H45K/Q45K
H55K/Q55K
H75K/Q75K
Dimensions [mm]
IP 20 /Chassis
FC 360
380-439V
T4 380 480 V
(High and normal overload)
Amp.
[4] Enclosure
For cabinet mounting:
E20
IP 20/Chassis
RFI-Filter class A2
[6] Braking
X
No brake IGBT
B
Built-in brake IGBT
* 0.37-22kW built-in; 30-75kW not
[7] Display (Local Control Panel)
X
No LCP, blind cover
* Following accessories available: NLCP, GLCP and blind
cover
[8] Conformal Coating (IEC 721-3-3)
C
[11]
[12]
SXX X
[13]
[14]
[10] Cable
X
No fieldbus option
A0
PROFIBUS
Enclosure
Typical Shaft Output
Typical Shaft Output at 460 V
IP 20
HO
[kW]
[HP]
HK37
0.37
0.5
HK55
0.55
0.75
HK75
0.75
1
J1
H1K1
1.1
1.5
H1K5
1.5
2
H2K2
2.2
3
H3K0
3
4
J2
H4K0
4
5.5
H5K5
5.5
7.5
J3
H7K5
7.5
10
Output Current
(3 x 380 440 V)
Continuous
[A]
1.2
1.7
2.2
3.7
5.3
7.2
12
15.5
Output Current
(3 x 441 480 V)
Continuous
[A]
1.1
1.6
2.1
3.4
4.8
6.3
8.2
11
14
[A]
1.9
2.7
3.5
4.8
5.9
8.5
11.5
14.4
19.2
24.8
Intermittent
(60 s overload)
Output Power
(400 V AC)
Continuous
[kVA]
0.8
1.2
1.5
2.1
2.6
3.7
5.0
6.2
8.3
10.7
Output Power
(460 V AC)
Continuous
[kVA]
0.9
1.3
1.8
2.5
2.8
5.2
6.8
9.2
11.6
[mm ]
([AWG])
4 mm2
Continuous
[A]
1.2
1.6
2.1
2.6
3.5
4.7
6.3
8.3
11.2
15.1
Continuous
[A]
1.2
1.8
2.9
3.9
4.3
6.8
9.4
12.6
Intermittent
(60 s overload)
[A]
1.9
2.6
3.4
4.2
5.6
7.5
10.1
13.3
17.9
24.2
Max. pre-fuses
Environment
Estimated power loss at rated max. load
Weight
IP 20
Efficiency
[A]
10
[W]
20.8
25.1
30
[kg]
2.3
0.96
2.3
2.3
IP 20
Enclosure
52.9
73.9
94.8
115.5
157.5
192.8
2.3
2.3
2.5
3.6
3.6
0.98
3.6
4.1
0.97
J4
32
40
J5
J6
H11K
(Q11K)
H15K
(Q15K)
H18K
(Q18K)
[kW]
[HP]
11
15
15
20
18
25
22
30
HO
(NO)
25
H22K
H30K
(Q22K) (Q30K)
J7
H37K
(Q37K)
H45K
(Q45K)
H55K
(Q55K)
H75K
(Q75K)
30
40
37
50
45
60
55
75
75
100
Output Current
(3 x 380 440 V)
Continuous
[A]
23
31
37
42.5
61
73
90
106
147
Output Current
(3 x 441 480 V)
Continuous
[A]
21
27
34
40
52
65
80
96
124
[A]
34.5
(25.3)
46.5
(34.1)
55.5
(40.7)
63.8
(46.8)
91.5
(67.1)
109.5
(80.3)
135
(99)
159
(116.6)
220.5
(161.7)
Intermittent
(60 s overload)
Output Power
(400 V AC)
Continuous
[kVA]
15.9
21.5
25.6
29.5
42.3
50.6
62.4
73.4
101.8
Output Power
(460 V AC)
Continuous
[kVA]
17.5
22.5
28.3
33.3
43.2
54
66.5
79.8
103.1
[mm2]
([AWG])
16 mm2
50 mm2
85 mm2
Continuous
[A]
22.1
29.9
35.2
41.5
57
70.3
84.2
102.9
140.3
Continuous
[A]
18.4
24.7
29.3
34.6
49.2
60.6
72.2
88.6
120.9
Intermittent
(60 s overload)
[A]
33.2
(24.3)
44.9
(32.9)
52.8
(38.7)
62.3
(45.7)
85.5
(62.7)
105.45
(77.3)
126.3
(92.6)
154.35
(113.2)
210.45
(154.3)
Max. pre-fuses
Environment
Estimated power loss at rated max. load
Weight
IP 20
Efficiency
[A]
50
80
160
250
[W]
289.5
393.3
402.8
467.5
630
848
1175
1300
1507
[kg]
9.4
9.5
12.3
12.5
22.4
0.98
22.5
22.6
37.3
38.7
13
PROFIBUS DP-V1
Primary Voltage:
2 8 Vrms
Primary Frequency:
2.0 kHz 15 kHz
Primary current max:
50 mA rms
Secondary input voltage:
4 Vrms
Ordering number:
132B0283
Status messages
Quick menu for easy
commissioning
Parameter setting and
adjusting
Hand-operated start/stop function or Automatic mode select
Reset function
Ordering number:
132B0254
Ordering number:
132B0281
and up to IP65
Encoder module supports:
Incremental encoders
SinCos encoders as Hyperface
Power supply for encoders
RS422 interface
Connection to all standard 5 V
incremental encoders
Ordering number:
132B0282
zontal
mounting
UL-recognized only types for
vertical mounting
14
Other accessories
Blind Cover, FC 360
Ordering number: 132B0262
Remote Mounting Kit for LCP
Ordering number: 132B0102
Graphical LCP
Adapter for FC 360
15
Environmentally
responsible
VLT products are manufactured
with respect for the safety and
well-being of people and the
environment.
All frequency converter factories
are certified according to ISO 14001
and ISO 9001 standards.
All activities are planned and
performed taking into account
the individual employee, the work
environment and the external environment. Production takes place
with a minimum of noise, smoke or
other pollution and environmentally safe disposal of the products
is pre-prepared.
UN Global Compact
Danfoss has signed the UN Global
Compact on social and environmental responsibility and our
companies act responsibly towards
local societies.
Dedicated to drives
Dedication has been a key word since
1968, when Danfoss introduced the
worlds first mass produced variable
speed drive for AC motors and
named it VLT.
Twenty five hundred employees
develop, manufacture, sell and service
drives and soft starters in more than
one hundred countries, focused only
on drives and soft starters.
Intelligent and innovative
Developers at Danfoss VLT Drives
have fully adopted modular principles
in development as well as design, production and configuration.
Tomorrows features are developed in
parallel using dedicated technology
platforms. This allows the development of all elements to take place in
parallel, at the same time reducing
time to market and ensuring that
customers always enjoy the benefits
of the latest features.
Danfoss VLT Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80
www.danfoss.com/drives, E-mail: info@danfoss.com
DKDD.PB.304.A3.02
PE-MMSC 2014.01