Manual
SUNFAR C320
PREFACE
Thank you very much for choosing C320 series of sensorless vector inverter.
This manual provides guidance of using the inverter safely and carefully, containing
introduction of installation, wiring, parameter list, routine maintenance, operating rules and
cautions, etc.
In order to make good use of the inverter properly and safely, please read this manual
thoroughly before using. It may lead to abnormal operation and failure, reduce using life, even
damage the equipment and cause personal injury if you use it wrongly.
This manual is attachment together with the inverter. Please keep it well and it would be
available to engineering and installation personnel, repairing and maintaining during the
product functioning period. SUNFAR has the right to modify and ameliorate products, data
and dimensions without notice, so this manual is updated and all the contents in this manual
are subject to change without any notice.
SUNFAR C320 3
Table of Contents
6
1 INTRODUCTION
6
5
6
SUNFAR C320
7.3 Reset 74
8 MAINTENANCE 75
8.1 Daily Maintenance 75
8.2 Damageable parts maintenance 76
8.3 Storage
76
8.4 After sale services76
9 USAGE EXAMPLE 77
9.1 Panel on-off control, Panel potentiometer setting frequency77
9.2 External on-off control mode, external voltage setting frequency
77
9.3 Multi-speed running, external on-off control mode 78
9.4 Panel on-off controlPanel potentiometer setting
frequency and linkage control with inverters 78
Operation panel
89
2.
Brake resistance 90
SUNFAR C320 5
PRECAUTIONS
In order to use the inverter properly and safely, please read this manual carefully before using. And you
should follow the requirements of this manual to move, install, run, operate and repair the inverter.
1. Opening
Please check any damage that may have occurred during transportation.
Please check whether the nameplate data of inverter is in accordance with your order, if anything wrong,
please contact supplier immediately.
Our product is manufactured, packed and transported in the strict quality system. But in case there is any
error, please contact with our company or local agent, we will solve the problem as quickly as possible.
z
Inverter's model
SOURCE:
Rated Parameters
OUTPUT:
2.4KVA 3.7A
0123456789
TYPE:
SERIAL No.:
Bar code
Fig-1 Nameplate
2. Safety regulations
There are four kinds of symbols being related with cautions as follows:
Danger: If user does not operate
according to requirements, it will lead to
death, grievous bodily harm or severe
property loss.
2.1 Installing
2.1.1.
2.1.2.
2.1.3.
2.2 Wiring
2.2.1.
2.2.2.
2.2.3.
2.2.4.
2.2.5.
SUNFAR C320
It is forbidden to connect an AC power supply with the U, V and W output terminals directly
2.3 Maintenance
1.
2.
3. Attention Notes:
3.1.
3.2.
3.3.
3.4.
4 Dispose:
When you dispose inverter and its parts, please pay attention to:
Capacitor: The capacitors in inverter may explode when they are burned.
Plastic: Poisonous gas may be generated when the front panel is burned, please pay attention to the waste
gas when the plastic parts are burned.
Method: Please dispose inverter as industry rubbish.
SUNFAR C320 7
1.
INTRODUCTION
Product
0015
0022
0037
.
.
.
2800
3150
Sensorless
C320
Vector
Drive
Voltage Class
2
4
Applied Motor
capacityKW
1.5
2.2
3.7
.
.
.
280
315
Power supply
220V
380V
T
S
3-phase
1-phase
Panel interface
Remote line interface
Operation panel
Upper cover
Mounting hole
Operation panel
Upper cover
WARNING
Lower cover
Control terminals
Main circuit terminals
SUNFAR C320
C320
Operation panel
Upper cover
Control terminals
WARNING
Lower cover
Main terminal
R S T
POWER
(+) (-)
U V W
MOTOR
Model
C320-2S0015
Rated Power
KVA
2.9
Rated output
currentA
7.5
Applied motor
Power (KW)
1.5
Rated power
KVA
--
Rated output
currentA
--
Applied Motor
Power (KW)
--
C320-2S0022
3.8
10
2.2
--
--
--
C320-2S0037
5.7
15
3.7
--
--
--
C320-2T0015
2.9
7.5
1.5
--
--
--
C320-2T0022
3.8
10
2.2
--
--
--
C320-2T0037
5.7
15
3.7
--
--
--
C320-2T0055
9.5
25
5.5
--
--
--
C320-2T0075
12.6
33
7.5
--
--
--
C320-2T0110
17.5
46
11
--
--
--
C320-2T0150
22.9
60
15
--
--
--
C320-2T0185
28.6
75
18.5
--
--
--
C320-2T0220
32.4
85
22
--
--
--
C320-2T0300
41.9
110
30
--
--
--
C320-2T0370
51.5
135
37
--
--
--
C320-2T0450
64.8
170
45
--
--
--
C320-2T0550
78.1
205
55
--
--
--
C320-4T0015
2.4
3.7
1.5
3.6
5.5
2.2
C320-4T0022
3.6
5.5
2.2
5.6
8.5
3.7
C320-4T0037
5.6
8.5
3.7
8.6
13
5.5
C320-4T0055
8.6
13
5.5
11
17
7.5
C320-4T0075
11
17
7.5
16.5
25
11
C320-4T0110
16.5
25
11
21.7
33
15
C320-4T0150
21.7
33
15
25.7
39
18.5
C320-4T0185
25.7
39
18.5
29.6
45
22
C320-4T0220
29.6
45
22
39.5
60
30
C320-4T0300
39.5
60
30
49.4
75
37
C320-4T0450
60
91
45
73.7
112
55
C320-4T0550
73.7
112
55
98.7
150
75
C320-4T0750
98.7
150
75
116
176
90
C320-4T0900
116
176
90
138
210
110
C320-4T1100
138
210
110
171
260
132
SUNFAR C320 9
General load (G-load) ([F0.15]=0)
Model
Rated Power
KVA
Rated output
currentA
Applied motor
Power (KW)
Rated power
KVA
Rated output
currentA
Applied Motor
Power (KW)
C320-4T1320
171
260
132
204
310
160
C320-4T1600
204
310
160
237
360
185
C320-4T1850
237
360
185
253
385
200
C320-4T2000
253
385
200
276
420
220
C320-4T2200
276
420
220
313
475
250
C320-4T2500
313
475
250
352
535
280
C320-4T2800
352
535
280
395
600
315
C320-4T3150
295
600
315
424
645
350
1.4 Specifications
Three-phase4T****
Single-phase2S****
380V, 50/60Hz
220V 50/60Hz
Permissible voltage
Three-phase4T****
Single-phase2S****
fluctuation
320V ~ 460V
170V ~ 270V
Voltage
Frequency
0~400Hz
Output
Over-loading Endurance
Control System
110% rated current for long-term 150% rated current for 1min
180% rated current for 2s
Sensorless current vector-control V/F control
Freq.
Analog Input
Control
Digital Input
0.01Hz
External pulse
Analog Input
Digital Input
External pulse
Resolution
Freq.
Precision
V/F control
Control
Torque boost
Automatic
current/voltage
Limiting
Characteristics
Sensorless
Current
vector control
And V/F curve with multi-mode can be discretionally set. There are also three
curves provided, Constant torque curve, Dec torque curve 1 and Dec torque
curve 2.
Manual torque boost can be set between 0 and 20 percent
Automatic torque boost can be set according to output current.
It will determine automatically the current and voltage of stator of motor, which
will be controlled within the allowable range.
Volt/Freq
characteristics
Torque
characteristics
Motors parameter
The motors parameter self-detection can finished in static state mode.
self-detection
Current / voltage
restraint
10
SUNFAR C320
Multi-speed selection
And Wobble freq. running
PID control
RS485 communication
Freq.
Analog input
Pulse input
Its amplitude value is between 5 and 30V, and its freq. is within 50.0KHz (can
receive OC signal)
Digital input
OC output
Two OC output, 16 options can be selected, faults electric delay out can be
selected (TA, TB and TC)
Analog output
Two output0~10V voltage, 0~20mA current, and upper/lower limit can be set
by user
Setting
Output Signal
Typical
Functions
Input voltage and compensation for speed drop is adjusted by real-time output
current.
To get the most stable running effect, user can select static stabilizing
voltage, dynamics stabilizing voltage and non-stabilizing voltage.
0.1 to 6000 seconds, S-curve or linear
Regenerative
braking
75% above
DC braking
Start and stop can be selected respectively, action freq. is form 0 to 50.0Hz,
and action time is form 1 to 20.0s. Continuous action is also optional.
Brake
To use the function of Smooth restarting and stop restarting during motor
works.
Counter
Operation functions
Setting of upper limit freq. and lower limit freq., freq hopping running,
Reversal running limit, slip freq. compensate, RS485 communication,
frequency Acc/Dec control, self-recovery running, etc
Operation Status
Out freq., Out current, Out voltage, Motor speed, Setting freq., Temperature
of Module, PID setting, Feedback value, Analog O/I, etc
Fault details
Recently six faults recorded, output freq., setting freq., output current,
output voltage, DC voltage and module temperature
Display
Protection/Warning Functions
Over current, over voltage, under current, under voltage, thermal relay,
overheating, Short circuit, out voltage would be short of the phase, The
parameters of motor is abnormal, Main contactor cant attract, Internal
memory faults, etc.
Ambient temperature:
-10~+50
Configuration
Installation
SUNFAR C320 11
2. INSTALLATION GUIDELINES
2.1 Environmental requirements:
1.
2.
3.
4.
5.
6.
7.
Fan ventilation
Above 120mm
E380
Inverter
Above 50mm
Above 50mm
WARNING
Inverter
Above 120mm
Assembly
Aim the fixed hook to spring clip at bottom of operation panel, then press the fixed spring backward. Then
push inward to the certain place. Shown as Fig. 2-2.
12
SUNFAR C320
Panel base
Spring cilp
Disassembly
Put the finger into the portable hole, pull upward to move the cover form the shell, then pull downward,
which will remove the cover board.
Assembly
Lift the bottom of cover up to about 15o, inserting the Fixed hook into the hold down groove, then press the
cover down to hear a sound of Click, which means the cover board has already been mounted and shown
as Fig. 2-3-A.
Fixed hook
Hole
Portable hole
Fig2-3-A
Disassembly and assembly of plastic cover board
Disassembly
1.
2.
Assembly
1.
2.
3.
SUNFAR C320 13
80
E3
H H1
2.4.2 Model
It is fit forC320-4T0110C320-4T0750/ C320-2T0055C320-2T0450.
W
W1
E 3 80
H1
WARNING
14
SUNFAR C320
2.4.3 Model
It is fit forC320-4T0900C320-4T2000/ C320-2T0900.
W
W1
D
E 3 80
H H1
!
WARNING
2.4.4 Model IV
It is fit forC320-4T2200C320-4T2800.
W
W1
E380
H H1
WARNING
SUNFAR C320
Inverter model
3-phase 400V
Inverter model
1-phase 220V
Inverter model
3-phase 220V
C320-4T0015
C320-2S0015
C320-2T0015
C320-4T0022
C320-2S0022
C320-2T0022
C320-4T0037
--
--
C320-4T0055
C320-2S0037
C320-2T0037
C320-4T0075
--
--
C320-4T0110
--
C320-2T0055
--
--
C320-2T0075
C320-4T0150
--
C320-2T0110
C320-4T0185
--
--
C320-4T0220
--
C320-2T0150
C320-4T0300
--
C320-2T0185
C320-4T0370
--
C320-2T0220
C320-4T0450
--
C320-2T0300
C320-4T0550
--
C320-2T0370
C320-4T0750
--
C320-2T0450
C320-4T0900
--
C320-2T0550
C320-4T1100
--
--
C320-4T1320
--
C320-2T0750
C320-4T1600
--
C320-2T0900
C320-4T1850
--
--
C320-4T2000
--
--
C320-4T2200
--
--
C320-4T2500
--
--
C320-4T2800
--
--
C320-4T3150
--
--
C320-4T3500
--
--
--
--
C320-4T4000
W1
(mm)
W
(mm)
H1
(mm)
H
(mm)
D
(mm)
Screw
123
134
223
234
165
M4
157
169
282
294
178
M5
184
204
328
344
199
M6
200
230
400
420
211
M6
232
260
450
470
233
M8
271
300
545
567
250
M8
344
381
588
614
298
M8
380
510
710
740
270
M8
400
580
760
793
300
M10
550
700
960
1000
340
M10
580
730
1103
1130
355
M10
--
--
--
--
--
--
SUNFAR C320 15
3. WIRING PROCEDURE
3.1 Precautions:
3.1.1.
3.1.2.
3.1.3.
3.1.4.
3.1.5.
3.1.6.
3.1.7.
3.1.8.
Installing a middle breaker between inverter and power supply in order to avoid enlarging the
accident.
Reducing the electromagnetic interference (EMI), please connect surge absorber to the coils of
electromagnetic contactors, relays, etc.
Frequency setting terminals (VC1, VC2, CC and PLS), Instrument circuit (AO1 and AO2), etc., these
analog signal wires should be over 0.3mm2 shield wire. Shield layer is connected with earth terminal
GND and the length of wire should be less than 30m.
Wire of relay input and output circuit(X1 ~ X6OC1OC2FWDREVRST) must be selected over
0.75mm2 shield wire. Shield layer should be connected to earth terminal CM and the length of wire
should be shorter than 50m.
Separating the main circuit wire from the signal/process circuit wiringparalleled wiring should be at
a distance of over 10cm and crossed wiring should be vertical with each other.
The wire must be less than 30m between motor and inverter. When the length of wire is over 30m,
the carrier frequency of inverter should be reduced properly.
All of leading wires should be tightened with the terminal adequately to ensure well-contact. The
leading wire of main circuit had better use the cable or cuprum tier, and wiring had better be
operated after the lug plate of corresponding sections cold pressing or welding.
Compressive resistance of all the wire should match with the voltage grade of inverter.
It is not allowed that UVW of inverter connect with the surge absorber capacitor or other surge absorber
equipment and shown as following Fig..
Motor
Inverter V
W
RC absorb device
AC
P+
PB
R / L1
C320
RUN
S / L2
Hz
J OG
<<
S ET
R EV
F WD
UP
D OW N
S TO P
T
!
E SC
W ARN ING
V
W
Power Supply
C320
Fig.3-2 wiring
16
SUNFAR C320
It is according to the rated input power specifications in manual.
Air-break switch
1. When the inverter is in maintenance or leave-unused, the air-break switch should isolate the
inverter with power supply.
2. Input side of inverter takes place the fault of short-circuits or low-voltage, the air-break will take the
protection.
z
z
Contactor
Control the power-on or power-off of inverter expediently.
AC electric reactor
1. Improve the power factor.
2. Reduce the harmonic wave input for the electric network.
3. Weaken the imbalance effect on 3-phase power voltage.
Brake resistor
In the situation of regenerative braking, avoiding bringing voltage too highly.
Applied MotorKW
Wire spec
(Main circuit)
Air-break
A
Magnetic
contactor
A
G-load
P-load
C320-2S0015
1.5
--
20
18
C320-2S0022
2.2
--
32
18
C320-2S0037
3.7
--
40
32
C320-2T0015
1.5
--
20
18
C320-2T0022
2.2
--
20
18
C320-2T0037
3.7
--
40
25
C320-2T0055
5.5
--
10
63
32
C320-2T0075
7.5
--
10
63
38
C320-2T0110
11
--
16
100
50
C320-2T0150
15
--
25
160
80
C320-2T0185
18.5
--
25
160
80
C320-2T0220
22
--
25
160
95
C320-2T0300
30
--
50
200
150
C320-2T0370
37
--
50
250
170
C320-2T0450
45
--
70
250
170
C320-2T0550
55
--
95
400
225
C320-2T0750
75
--
95
400
330
C320-2T0900
90
--
150
630
330
C320-4T0015
1.5
2.2
2.5
16
12
C320-4T0022
2.2
3.7
16
12
C320-4T0037
3.7
5.5
20
18
C320-4T0055
5.5
7.5
32
Air-break
A
18
Magnetic
contactor
Model
Applied MotorKW
mm2
Wire spec
(Main circuit)
SUNFAR C320 17
G-load
P-load
C320-4T0075
7.5
11
40
25
C320-4T0110
11
15
10
63
32
C320-4T0150
15
18.5
10
63
38
C320-4T0185
18.5
22
16
100
50
C320-4T0220
22
30
16
125
50
C320-4T0300
30
37
25
160
80
C320-4T0370
37
45
25
160
95
C320-4T0450
45
55
50
200
115
C320-4T0550
55
75
50
200
150
C320-4T0750
75
90
70
250
170
C320-4T0900
90
110
70
315
225
C320-4T1100
110
132
95
400
225
C320-4T1320
132
160
95
400
330
C320-4T1600
160
185
150
630
330
C320-4T1850
185
200
150
630
400
C320-4T2000
200
220
185
630
400
C320-4T2200
220
250
185
800
500
C320-4T2500
250
280
240
800
500
C320-4T2800
280
315
240
1000
630
C320-4T3150
315
350
300
1000
630
Three-phase Breaker
Three-phase
Power supply
Motor
X1
Ta
X2
Tb
X3
Tc
Earth
Programmable output
X4
X5
X6
PB
CM
FWD Order
FWD
AO1
REV Order
REV
AO2
Fault Reset
RST
GND
CM
OC1
0 ~ 5V Frequency set
VS
OC2
VC1
CM
CC
VC2
PLS
Open-circuit
Collector output
GND
18
SUNFAR C320
3.4.1. I model
It is fit for C320-4T0015 ~ C320-4T0075 / C320-2S0015 ~ C320-2S0037.
Brake resistance
P+
P-
PB
Earth
Motor
3-phase power supply
P+
P-
PB E
DC Electric reactor
Earth
Motor
3-phase power
DC Brake Unit
P+
P-
DC Electric reacor
Earth
Motor
Brake Unit
3-phase power
P+
P-
3.4.5. V model
Brake
Baker Unite
unit
Earth
DC Electric reactor
3-phase power
Motor
It is fit forC320-4T2200C320-4T2800
SUNFAR C320 19
E a rth
3 -p h a s e p o w e r
P-
E a rth
P+
D C E le c tric re a c t o r
M o to r
B ra k e U n it
Description of terminal:
Terminal
Function
P-
P+
PB
RST
UVW
Earth Terminal
X1
TA
TB
TC
X2
X3
X4
Terminal
VS
Analog
Input
Control
Function
Notes
Switch JP1
VC1
0~5V
VC2
0~10V
CC
0~20mA
PLS
050KHz/5~30V
GND
X1
20
SUNFAR C320
X2
X3
X4
X5
X6
FWD
REV
RST
CM
24V
AO1
AO2
GND
Analog
Output
OC
OC1
Output
OC2
PLC
output
TA
TB
RS485
ERH
TC
Interface
Description about JP
JP1
1-2 short-circuitInput +5V/50mA signal
2-3 short-circuitInput +10V/10mA signal
JP2
1-2 short-circuitAO1input voltage signal
IO1
VO2
VO1
IO2
+10V
+5V
SUNFAR C320 21
4.1Operation panel
4.1.1 Panel layout
Main LED
Unit
Hz
Main LED
RUN
Hz
Auxiliary LED
Return
Unit
Potentiometer
Switch
Set
Return
ESC
JOG
<<
REV
Switch
Increasing
Jog
SET
SET
REV
FWD
FED
Stop
Decreasing
FWD
REV
Increasing
STOP
Stop
Decreasing
Display
Function
Main LED
Auxiliary
LED
AHzV
RUN
Keypad
REV key
When F0.1 is 1 and press this key, the inverter will be running backward to setting frequency
according to appointed ACC or DEC curve.
Stop and Reset key
When F0.4 is 000#, STOP is valid for panel control. If F0.4 is 000#, STOP is valid for all kinds of
control methods. If inverter occur fault, press this key to reset it and return stop mode.
If stop key is used together with
copy and read-in of internal parameters will be done.
22
SUNFAR C320
Return key
Press this key in normal monitor state to enter query mode of not normal monitor state /monitor
parameters to check running state. In any state, press this key to return the upper state.
This key is used together with
to perform Parameter read / backup.
Set key
This key is used together with
to
or
. And press
key to return
or
. And press
key to return
key to enter Modify and check internal parameter mode under normal mode with general ways to
SUNFAR C320 23
Under normal monitor mode, press 1
and
2 key simultaneously to enter Modify and check the
backup parameter mode. When panel displays function code, F in the fourth place of main LED will be
displayed blink, which means current modify and check parameters is backup parameter.
4.2.2 Methods of panel operation
(1) State parameter inquiry (eg.)
Output freq.
Output current
d-0
Monitor code
Output freq.
Return
+
State Parameter Main display:
Inquiry
Parameter
Inquiry
d-5
Main display:
383
Function code
Output current
Input voltage
Output current
+
Parameter Edit
Main display:
F0.0
Auxiliary display: 0
Function code
Parameter data
24
SUNFAR C320
Modify
backup
parameter
45.00
Output freq.
Output current
+
Parameter
Inquiry
Main display:
F0.0
Auxiliary display: 0
Give up
Modify
Function code
Parameter data
Continue Modify or
Return
+
Parameter
Inquiry
Main display:
F0.2
Function code
Give up
Modify
Parameter data
Parameter
Parameter data
Inquiry
Output current
Parameter
Parameter data
Modify
Output current
Parameter
Storage
Function code
Parameter data
SUNFAR C320 25
Content
d.0
d.1
Unit
Hz
(Valid)
d.2
d.3
A
V
rpm
d.4
DC bus voltage
d.5
d.6
Setting freq.
Hz
d.7
d.8
d.9
d.10
d.11
d.12
d.13
d.14
mA
d.15
KHz
d.16
d.17
Temperature of module
d.18
d.19
d.20
Magnetization current
d.21
d.22
Torque current
d.23
d.24
Reserved
d.25
Reserved
d.26
d.27
d.28
d.29
d.30
d.31
d.32
Hz
d.33
Hz
d.34
d.35
d.36
d.37
26
SUNFAR C320
Three-phase
Breaker
Power supply
R
S
T
Motor
U
V
W
E
Earth
Carrier wave frequency is fixed value between 1.5 and 12 KHz. If motor does not take any load, it will a slight
oscillate. So please decrease setting value of F0.16.
SUNFAR C320 27
5. PARAMETERS LIST
Symbol description:
means that this parameter can not be changed during operation.
means that this parameter is related to the inverters model.
Function Code
Name
Setting range
01H
0.01
0.0
02H
0000
03H
0000
04H
0000
06H
0.01
0.0
07H
0.01
50.00
08H
F0. 3
F0. 4
F0.5
F0.6
00H
05H
28
SUNFAR C320
Function Code
Name
Setting range
F0.9 Reserved
F0.10 Acc time 1
0.1
0AH
0.1
0BH
0000
0CH
0.1
20.0
0DH
0.01
60.0
0EH
0FH
0.1
10H
1110
11H
12H
13H
0.0~20.0
0.1
14H
0Manual
0.01
50.00
16H
200500V
380
220
17H
F0.12
F0.13
F0.14
F0.15
F0.17
09H
Carrier wave
characteristics
1Automatic
100250V
15H
SUNFAR C320 29
Function Code
Name
Setting range
[F1.7] ~ [F1.3]
0.0
[F1.8] ~ 100.0(%)
0.1
0.0
19H
[F1.9] ~ [F1.5]
0.01
0.0
1AH
[F1.10] ~ [F1.6]
0.1
0.0
1BH
0.0 ~ [F1.7]
0.01
0.0
1CH
[F1.1] ~ [F1.8]
0.1
0.0
1DH
0.1
50.0
0.1
0.0
380V
220V
22H
5.00600.00Hz
0.01
50.00
23H
0.01300.0A
0.01
24H
25H
0.01
26H
27H
0001
0.01
0.30
0010
1EH
F1.13 Reserved
1FH
20H
200500V
100250V
18H
21H
28H
29H
2AH
30
SUNFAR C320
Function Code
Name
Setting range
0.00020.000
0.001
2BH
0.00020.000
0.001
2CH
0.00600.00 mH
0.01
2DH
0.00600.00 mH
0.01
2EH
0.00100.00 mH
0.01
2FH
0.01
1.00
F1.28
Leakage inductance
(coefficient)
F1.29
30H
F1.30 Reserved
F2.0
F2.1
F2.2
F2.3
F2.4
F2.5
F2.6
31H
0.0 ~ [F2.1]
0.1
0.0V
32H
[F2.0] ~ 5.0V
0.1
5.0 V
33H
0.0V ~ [F2.3]
0.1
0.0 V
34H
[F2.2] ~ 10.0V
0.1
0.0mA~ [F2.5]
0.1
4.0
36H
[F2.4] ~ 20.0mA
0.1
20.0
37H
10.0V
35H
0.0KHz~[F2.7]
0.1
0.0
38H
[F2.6]~50.0 KHz
0.1
10.0
39H
0.0~[F2.9]
0.01
0.0
3AH
[F2.8]~550.0Hz
0.01
50.00
3BH
0000
0.01
0.10
3DH
3EH
F2.10
Characteristics selection
of input channel
F2.11
0.011.00Sec
3CH
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
SUNFAR C320 31
Function Code
F2.13
Name
Setting range
0010
3FH
0.0[F2.15]
0.1
0.0 V
40H
[F2.14]12.0
0.1
10.0V
41H
0.0[F2.17]
0.1
2.0 V
42H
[F2.16]12.0
0.1
10.0V
43H
F2.18 Reserved
F3.0
F3.1
F3.2
F3.3
F3.4
F3.5
44H
45H
46H
47H
48H
13
49H
14
4AH
32
SUNFAR C320
Function Code
Name
Setting range
4BH
4CH
16
4DH
0.0~20.00Hz
0.01
5.00
4EH
0.01
10.00
0.1~200.0S
0.1
2.0
0.01
10.00
0.1
2.0
50~200%
110
Over-loading alarm
F3.15
delay time
0.0~20.0 S
0.1
2.0
F3.9
4FH
51H
52H
53H
F3.16 Reserved
50H
54H
55H
0Routine mode
1Detect speed and restart
0Decelerate mode
1Uncontrolled stop
0.010.00Hz
0.01
0.5
0.020.0 S
0.1
0.0
59H
0.01
3.00
5AH
0.1
0.1
5BH
0.1
0.0
0.1
50.0
5DH
0.01
0.0
5EH
0.050.00Hz
0.01
1.00
5FH
0.01
10.00
60H
110200%
160
61H
56H
57H
58H
5CH
SUNFAR C320 33
Function Code
Name
Setting range
10150%
0Invalid
1Valid
80
62H
110
63H
64H
65H
0.1
0.0
66H
0.16000 s/min
0.1
67H
0.16000 s/min
0.1
68H
0.16000 s/min
0.1
69H
0.16000 s/min
0.1
6AH
0.16000 s/min
0.1
6BH
0.16000 s/min
0.1
6CH
0.01
10.00
6DH
700V
6EH
60
6FH
0010
70H
0.1
0.5
71H
F4.28 Reserved
72H
0000
73H
0.01
35.00
74H
0.01
15.00
75H
0.01
3.00
76H
34
SUNFAR C320
Function Code
Setting range
0.01
20.00
77H
0.01
25.00
78H
0.01
30.00
79H
0.01
35.00
7AH
0.01
40.00
7BH
0.06000s
0.1
10.0
7CH
0.06000s
0.1
10.0
7DH
0.06000s
0.1
10.0
7EH
0.06000s
0.1
10.0
7FH
0.06000s
0.1
10.0
80H
0.06000s
0.1
10.0
81H
0.06000s
0.1
10.0
82H
0.06000s
0.1
10.0
83H
0000
84H
0000
85H
F5.9
F5.10
F5.11
F5.12
Multi-speed running parameter unit
Name
F5.13
F5.14
F5.15
F5.16
Running time of
Multi-speed 1
Running time of
Multi-speed 2
Running time of
Multi-speed 3
Running time of
Multi-speed 4
Running time of
Multi-speed 5
Running time of
Multi-speed 6
Running time of
Multi-speed 7
Running time of
Multi-speed 8
F5.19 Reserved
86H
0Off
Inverter stop when motor
F6.0
1Inverter will run when motor
is cut off
is connected with it.
87H
012
88H
F6.2
0.220S
0.1
2.0
89H
F6.3
160000
8AH
160000
0.01
0.0
8CH
0.05.00Hz
0.01
0.0
8DH
0.01
0.0
8EH
F6.6
Amplitude accumulation
Of Skip freq. 1
8BH
SUNFAR C320 35
Function Code
Name
Setting range
F6.8
Amplitude accumulation
of Skip freq. 2
0.05.00Hz
0.01
0.0
8FH
F6.9
0.01100.0
0.01
1.00
90H
F6.10
Close-loop analog
coefficient setting
0.01100.0
0.01
1.00
91H
F6.11
0.01
1.00
92H
011
93H
011
94H
0 ~ 9999
95H
F6.14
Query or modify
parameters
1Allow
96H
97H
09999
1000
98H
09999
100
99H
0 ~ 9999
9AH
1000
F7.0
F7.1
0.01
10.00
F7.2
0.06000.0s
0.1
0.0
0.1
10.0
0.080.0%
0.1
10.0
9FH
0.11000.0s
0.1
10.0
A0H
0.11000.0s
0.1
10.0
A1H
0.01
10.0
A2H
F7.8 Reserved
9BH
9CH
9DH
9EH
A3H
36
SUNFAR C320
Function Code
Name
Setting range
0020
A4H
0000
A5H
F8.1
F8.2
0.0010.00V
0.01
0.0
A6H
0.0[F8.4]
0.01
0.0
A7H
[F8.3]10.00
0.01
10.00
A8H
0.010.00
0.01
0.0
A9H
0.010.00
0.1
10.00
AAH
0.05.00
0.01
1.00
ABH
1.0500.0s
0.1
10.0
ACH
0.020.0%
Feedback of minimum
F8.5
fixed value
Feedback of maximum
F8.6
fixed value
0.1
0.0
ADH
0.01
0.0
AEH
0.06000.0s
0.0
0.0
0.010.00
0.01
10.00
AFH
B0H
SUNFAR C320 37
Function Code
Name
Setting range
0.010.00
0.0
B1H
F8.14 Reserved
B2H
030
B4H
01000ms
5ms
B5H
Function setting of
F9.3 communication
Auxiliary function
0010
B6H
0.0100.0s
0.1
10.0
B7H
0.01
1.00
B8H
B9H
F9.4
Checkout time of
communication overtime
0Close
1Panel potentiometer
Rectify channel 2
Rectify channel of linkage External voltage signal VC10 ~ 5V
F9.6
setting proportion
Rectify channel 3
External voltage signal VC20 ~ 10V
Rectify channel 4
External current signal CC0 ~ 20mA
0014
F9.7 Reserved
B3H
BAH
360480V
390
BBH
660760V
700
BCH
180
BDH
FC.2
FC.3 Reserved
FC.4
BEH
Protection function in
operation
3333
BFH
38
SUNFAR C320
Function Code
Name
Setting range
0000
C0H
0000
C1H
FC.7 Reserved
C2H
0 ~ 9999
100
C3H
0.01
1.00
C4H
0.01
1.00
C5H
0.01
1.00
C6H
Compensation rectify of
FC.12 dead zone
025
C7H
21002199
C8H
SUNFAR C320 39
Setting range0 ~ 1
It will get prime performance when inverter matches the same capacity motor in vector control.
Explanations
1. It need use some basic parameters of motor when inverter takes vector control. C320 serial inverter
provides those basic parameters of motor, and those parameters were set.
2. When basic parameters of applied motor are different from parameters provided by inverter, those
parameters must be set again (code [F1.15] ~ [F1.18]). Users can get those parameters by setting code
F1.20 (Parameters self-determination).
Note: if users have no nameplate parameters of applied motor or inverter inverters some motors, please take
V/F method.
F0.1 Frequency input channel / mode selection
Setting range0 ~ 9
40
SUNFAR C320
RS485 interface
Panel potentiometer
When F0.1 is 0, Frequency digital setting controls output frequency of inverter. In normal monitor state,
user can use the key
and
to modify this parameter.
As for F0.1 is s 1 or F0.1 is 2, the frequency will save in parameter F0.3 after power off, if F0.3 is 00#0.
F0.3
When F0.1 is 0, 1 or 2, set parameter F0.3 to ensure that setting freq. is or not be saved in F0.2.
The first part of LED(form right to left)
0Inverter will run in setting freq. that is storage in F0.2 after stopping
1Setting freq. will loss after stopping. And inverter will run in 0.0Hz when restarting
The second part of LED(form right to left)
0Setting freq. is kept when stopping
1Setting freq. will save in F0.2 when stopping
2Setting freq. is clear when stopping
The third and fourth part of LED(form right to left)Reserved.
F0.4 Operation channel selection
SUNFAR C320 41
Instruction
FWD
Stop instruction
REV
Terminals
FWD
FWD
FWD
FWD
State
REV
REV
REV
REV
CM
CM
CM
CM
2 RS485 interface
The inverter will receive running instruction from master.
The second part of LED (form right to left): to select function of the key
.
0It is valid for panel control.
When F0.4 is 0, Stop key on the operation panel is available.
1It is valid for all kinds of control method.
When F0.4 is not 0 and press stop key
, inverter will emergency stop and twinkling display Fu.16.
The third and fourth part of LED(form right to left)Reserved.
F0.5 Combination methods of instruction terminals
Setting range0 ~ 2
FWD
Stop instruction
Terminals
State
REV
FWD
FWD
FWD
FWD
REV
REV
REV
REV
CM
CM
CM
CM
0Two-line mode 2
Introduction
FWD
Stop instruction
REV
Terminals
FWD
FWD
REV
REV
State
CM
CM
CM
CM
2Three-line mode
Please select a three-line mode terminal to set three-line mode. (Refer to description of parameters F3.0 ~
F3.5) Xis three-line mode terminalsand it is any one among terminals X1 ~ X6.
Switch function is shown as follow
1. SW1 Stop trigger switch of inverter
Output freq.
X?
SW2
SW3
FWD
REV
SW1
CM
SW2
SW3
Fig.6-1 three-line mode wiring
42
SUNFAR C320
F0. 6
This parameter is used for modifying the present output phase sequence of inverter, which modifies the
running motor direction. Control effect of panel control method is shown as following table.
Parameter F0.4 is valid together with direction control of external terminals.
F0.7
F0.8
FWD-CM
[F0.6]
OFF
##1#
FWD
ON
##1#
FWD
OFF
##00
FWD
OFF
##01
REV
ON
##00
REV
ON
##01
FWD
Direction
When setting freq. is lower than lower limit freq., the inverter will run in lower limit freq. But the parameters
F4.8 and F4.9 are priority over F0.7 and F0.8.
F0.9
Reserved
F0.10
F0.11
Acc time 1
Dec time 1
Acc time 1 is the time of output frequency accelerating from 0.0 Hz to 50.00Hz.
Dec time 1 is the time of output frequency decelerating from 50.00 Hz to 0.00Hz.
Units of Acc and Dec are set by parameter F0.12.
F0.12
The first part of LED(form right to left)It is used for setting curve type when inverter is accelerating or
decelerating, shown as fig6-3.
0Beeline
Output freq. of inverter will increase or decrease according to fixed rated.
1S curve
Output freq. of inverter will increase or decrease according to graded rated. Characteristics of S curve is set
by parameter F0.13 and F0.14.
The second part of LEDTo set Acc/Dec method
0Output freq. will be modified according to Acc/Dec time.
1Output freq. will be automatically modified according to load.
The third part of LEDIt is used for setting unit of Acc/Dec time, namely unit of parameters F0.10, F0.11,
F4.17, F4.18, F4.19, F4.20, F4.21 and F4.22.
0 Sec.
1 Minute
The fourth part of LEDReserved.
SUNFAR C320 43
Output freq.Hz
Beeline
S curve
TSec/min
[F0.13][F0.14]
F0.13
F0.14
Parameters F0.13 and F0.14 define characteristics of S curve. It is totally divide into three sections, shown as
fig6-13.
Acc/Dec initial section is process that slope of output freq. is gradual increase form 0. The slope will fix in
Acc/Dec ascending/decline section. And the slope will gradual decrease to 0 in end section.
F0.15 Load pattern selection
0 General-purpose load.
Setting range01
Carrier wave frequency influences audio-frequency noise and calorific effect in running.
When environment temperature is too high and motors load is too heavy, carrier frequency should be
decreased properly to improve the heat thermal performance.
F0.17 Carrier wave characteristics
Parameter write-protect
Setting range12
Setting range 0 ~ 3
44
SUNFAR C320
[F.1.3]
It is used for improving the low-frequency torque characteristics. In low-frequency running, it will make boost
compensation for the output voltage of inverter, as shown in Fig.6-5.
Boost voltage =
[F1.4]
[F1.1]
[F1.4]
200
Voltage
[F1.4]
Voltage
[F1.1]
[F1.1]
Boost voltage
Boost voltage
f
[F1.3]
[F1.3]
1Decreasing torque curve
Setting range0 1
0Manual
Torque boost voltage is completely controlled by F1.1. There are two features: voltage will steady boost. And
motor will easily magnetic saturation when light-load.
1Automatic
Torque boost voltage is changed with the stator current of motor. The boost voltage is higher with the stator
current higher.
Boost voltage =
[F1.1]
200
[F1.4]
Auto torque boost can prevent the magnetic saturation, as the boost voltage is too high with light load, which
SUNFAR C320 45
can avoid the over-heat phenomenon of motor in low frequency running.
F1.3 Basic running frequency
F1.4 Max output voltage
Basic running frequency is corresponding minimum frequency when output voltage of inverter is highest.
Usually, it is rated frequency of motor.
Max output voltage is corresponding output voltage when inverter outputs the basic running frequency.
Usually, it is rated voltage of motor.
F1.5
F1.6
F1.7
F1.8
F1.9
F1.10
V/F freq. 3
V/F voltage 3
V/F freq. 2
V/F voltage 2
V/F freq. 1
V/F voltage 1
Those parameters are used for setting user-defined curve which user need. Shown as Fig.6-6 below:
Voltage
[F1.4]
[F1.6]
[F1.8]
[F1.10]
[F1.1]
Freq.
[F1.9]
Those parameters are fit for occasion that inverter needs brake before start. Shown as Fig.6-7.
F1.11=
100%
When rated current of motor is lower than rated current of inverter, please pay attention to set
F1.11.Make sure that DC braking current is lower than rated current of motor.
Parameter F1.12 defines duration that inverter output DC braking current. When F1.12 is 0, DC braking is
invalid when starting.
46
SUNFAR C320
Output Freq.
Starting
freq.
DC braking
[F1.12]
[F4.4]
[F4.1]
Output
current
[F1.11]
[F4.7]
[F4.6]
Instruction
[F4.2]
[F4.5]
F1.13
The inverter will modify output freq. automatically to offset effects that is act on rotate speed of motor form
load.
Output freq.
Compensation for slip freq. is 100%
150%
100%
Before
After
50%
Rotor speed
F1.14
F1.15
F1.16
F1.17
They are nameplate parameters of applied motor. The running performance will improve if those parameters
are input correctly.
F1.18
Reserved
F1.15
F1.16
F1.17
F1.18
F1.19
Those parameters are nameplate data of applied motor. And they need input one by one according to
capacity of applied motor, when inverter takes vector method.
Generally, exciting current of applied motor neednt modify. Because it will automatic update when rated
current of applied motor is modified.
F1.20 Parameters self-determination
0 It will invalid.
Setting range 0 ~ 3
SUNFAR C320 47
1 Determine parameters when motor is stop
2 Determine parameters when motor is runReserved
Both vector control method and panel control method are valid, parameter F1.20 will act.
When parameter F1.20 is valid, inverter will determine parameters by press key
Parameters will save
automatically in inverters memory and Parameter F1.20 will to clear.
Before start function of Parameters self-determination, please make sure that nameplate parameters of
motor[F1.15] ~ [F1.18]are input correctly and motor stops.
When capacity of applied motor is equally match inverters, user starts function of Parameters
self-determination is not necessary.
If motor isnt connect with inverter correctly, self-determination will stop and LED of inverter will show fault
Fu.30Fu.33.
F1.21
F1.22
[F1.19]
Output freq.
[F1.22]
48
SUNFAR C320
F1.23
It is used for selecting self-adapting rectify of motor parameters functionset by binary system.
The first part of LED (form right to left): to select self-adapting rectify of stator resistance function
0:Self-adapting rectify of stator resistance is invalid
1:Self-adapting rectify of stator resistance is valid
The second part of LED (form right to left): to select self-adapting rectify of excitation function
0:Self-adapting rectify of excitation is invalid
1:Self-adapting rectify of excitation is valid
The third part of LED (form right to left): to select self-adapting rectify of rotor resistance function
0:Self-adapting rectify of rotor resistance is invalid
1:Self-adapting rectify of rotor resistance is valid
The fourth part of LED (form right to left): reserved.
Some parameters of motor have been influenced by temperature change, and control performance is
affected if setting value isnt precision. When motor have selected corresponding function, inverter will
optimize parameters automatically in running, which can improve the performance and stability of motor.
F1.24
F1.25
F1.26
F1.27
F1.28
stator resistance
rotor resistance
rotor inductance
excitation inductance
Leakage inductance (coefficient)
Those parameters are used for setting motors basic parameter. They are necessary for complete vector
control arithmetic. Client can use inverters interior parameters when capacity of inverter matches motors.
When the performance of inverter cant satisfy the users demand, you can use function of parameters
self-determination to renew some parameters. If user can get these parameters precisely beforehand,
parameters also can be input one by one. When parameters are initializing, inverter will renew interior
acquiescence parameter according to type.
Before start function of parameters self-determination, user must make sure that input nameplate parameter
of motor.
F1.29
Parameter F1.29 is valid when inverter takes vector control method. It is used for offsetting error of setting
motor rotor parameter. The parameter is read only.
F1.30
Reserved
F2.2
F2.3
F2.4
F2.5
F2.6
F2.7
SUNFAR C320 49
[F2.0] and [F2.1] define the range of analog input voltage channel VC1, and it should be set according to the
actual input signal.
[F2.2] and [F2.3] define the range of analog input voltage channel VC2, and it should be set according to the
actual input signal.
[F2.4] and [F2.5] define the range of analog input current channel CC, and it should be set according to the
actual input signal.
[F2.6] and [F2.7] define the freq. range of external pulse signal.
F2.8
F2.9
They define the Corresponding relation between analog input (pulse input) and setting frequency. Shown as
fig.6-9.
F2.10
It is used for selecting input characteristics of external analog value or pulse value.
The first part of LED (form right to left):It defines characteristics of voltage signal analog input VC1.
0 positive characteristics
1Negative characteristics
The second part of LED (form right to left): It defines characteristics of voltage signal analog input VC2.
0 positive characteristics
1Negative characteristics
The third part of LED (form right to left): It defines characteristics of current signal analog input CC.
0 positive characteristics
1Negative characteristics
The fourth part of LED (form right to left): It defines characteristics of pulse signal analog input PLS.
0 positive characteristics
1Negative characteristics
The corresponding relation is shown as fig.6-10 between input signal and setting freq.
Freq.
Freq.
Output freq.
Output freq.
[F2.9]
[F2.9]
[F2.8]
[F2.8]
F2.11
Setting freq. set by external analog input will be filtered to eliminate fluctuate. Time constant of filtering have
to appropriate set according to fluctuate of external input signal.
F2.12
Setting range0 ~ 29
The parameter is valid only when the frequency input channel F0.1 is set as 8.
50
SUNFAR C320
Setting
Value
Setting
Value
11
8
10
12
13
14
15
16
17
18
19
21
23
20
22
24
26
28
F2.13
25
27
29
SUNFAR C320 51
F2.14
F2.15
F2.16
F2.17
Those parameters define the max and min value of analog output AO1and AO2, shown as fig 6-11.
AO1/AO2
[F2.15]
[F2.17]
[F2.14]
[F2.16]
Upper limit voltage Output freq.
Output current
Output voltage
Rotor speed
PID setting
10.00
10.00
PID
1
2
3
4
5
6
Rated current
The max/rated Voltage
AO1 and AO2 provide voltage signal form 0 to 12V or current signal form 0 to 24 mA. Two kinds of output
signal can be selected by JP (JP1 and JP2) switch. JP1 and JP2 are shown as fig.6-12.
JP2
1-2 shortedAO1 output voltage signal
2-3 shortedAO1output current signal
IO1
VO2
VO1
JP3
1-2 shortedAO2 output voltage signal
IO2
+10V
+5V
F2. 18
Reserved
Setting range0 ~ 25
Setting range0 ~ 25
Setting range0 ~ 25
Setting range0 ~ 25
Setting range0 ~ 25
Setting range0 ~ 25
52
SUNFAR C320
SUNFAR C320 53
F3.6 Output terminal OC1
F3.7 Output terminal OC2
F3.8 TA, TB and TC of relay contacts
Setting range0 ~ 18
Setting range0 ~ 18
Setting range0 ~ 18
It defines expression content of relay contact and terminals OC1 and OC 2 when collector is open-circuit.
Shown as fig.6-13.
When TA is on with TC, setting functions will be available.
f
Setting freq.
O utput freq.
O utput freq.
High resistance
Setting frequency
[F3.10]
[F3.12]
FDT Level
[F3.11]
[F3.13]
[F3.11]
[F3.13]
54
SUNFAR C320
3. Over-loading alarm
When the output current of inverter is over the over-loading alarm level, it will output the valid signal (Low
level) after the setting alarm delay time. When the output current is lower than the over-loading alarm level,
it will output the invalid signal (High resistance) after the same delay time.
O u tp u t c u rre n t
A la r m
le v e l
OC
H ig h r e s is ta n c e
[F 3 .1 5 ]
[F 3 .1 5 ]
H ig h r e s is ta n c e
t
SUNFAR C320 55
F3. 9 Frequency reach the checkout amplitude
If output freq. of inverter is within setting value that is set in F3.9, selected terminal will output valid signal.
Shown as fig.6-13.
F3.10
F3.11
F3.12
F3.13
FDT setting 1
FDT output delay time 1
FDT setting 2
FDT output delay time 2
The parameter is used for setting the frequency detection level. When output frequency is higher than the
setting value of FDT, after the setting delay time, terminals will output the valid signal, shown as fig.6-14.
Parameters F3.10 and F3.11 are used for setting FDT of OC1, parameters F3.12 and F3.13 are used for
setting FDT of OC2.
F3.14 Overload alarm level
F3.15 Overload alarm delay time
If output freq. beyond the setting value set by parameter F3.14, after the setting delay time set by parameter
F3.15, terminals output valid signal, shown as fig.6-15.
F3.16
Reserved
Setting range01
Setting range0.010.00Hz
Setting range0.020.0s
Those parameters are used for defining characteristics with relation to start mode, shown as fig6-17.
The explanation of F4.0 is shown as following.
0 Routine mode
It is fit for mostly load, which have not special demand.
1Detect speed and restart
It is fit for fault reset and restart occasion, or, power off and restart occasion. Inverter will judge automatically
running speed and direction of motor. Motor, which have not stop, will start up directly according to detect
result.
Start frequency It is fit for system, which is big inertia, heavy load and high start torque.
f
Decelerate stop
with no DC braking
Setting freq.
[F4.2]
[F4.1]
Free stop
t
Start
Setting range0 ~ 1
C320 Series of Sensorless Vector Inverter Operation Manual
56
SUNFAR C320
0 Decelerate mode
Inverter will gradually decrease output freq. to 0 according to Dec time when stopping.
1 Uncontrolled stop
Inverter will output zero freq. and lock output signal when stop, so motor will uncontrolled stop.
If user needs restart motor before motor complete stop, function of detect speed and restart must be valid
when inverter is uncontrolled stop.
Start mode and stop mode is shown as fig6-16.
F4.4 Initial freq. of DC braking when stopping
F4.5 Waiting time of DC braking when stopping
F4.6 Action time of DC braking when stopping
F4.7 DC braking current when stopping
[F2.0]
[F2.5]
[F2.5]
[F4.8]
Initial setting freq.
[F4.9]
SUNFAR C320 57
Jog Acc time
[F4.21]
Jog Dec time
[F4.22]
Jog Freq.
[F4.10]
t
Jog signal
f
Jog Acc time
[F4.22]
Jog Freq.
[F4.10]
Jog Dec
[F4.21
t
Jog signal
F4.11
It is used for setting permissible output level of torque current under motor acceleration state.
The restriction on torque level is set by F4.11. It is percentage of rated current of inverter. For example, F4.11
set 150% that means the max output current is 150 percentage of rated current.
When output current of inverter is beyond setting value of F4.11, inverter will prolong Acc/Dec time to inhibit
output current in setting value of F4.11. Shown as fig6-20.
f
Modified Dec time
Braking
torque
level
t
Fig6-20 Acc torque level
It fits for occasions where demand high performance with braking torque. If setting value of parameter F4.12
is big, the Braking effect will obvious. But inverter will alarm about over voltage if inverter is not connect
braking resistance.
58
SUNFAR C320
The parameter is used for setting the sensitivity of thermal relay protection for applied motor. When the rated
current of applied motor doesnt match with the rated current of inverter, it can accomplish the correct heat
protection for the motor to set this parameter.
The setting value of this parameter can be set by the following formula:
[F4.13]=
100
While one inverter parallel running with multi-motors, the thermal relay protection of inverter will be
invalid, in order to protect the motor, please install the thermal relay on inlet terminals the motor.
F4.14
Setting range0 ~ 2
The function of Automatic voltage regulation is to ensure the output voltage of inverter not to fluctuate with
the input voltage. When the range of fluctuation of power supply voltage is too large, and expect to motor
have the stabilized stator voltage and current, this function should be open.
0Invalid
1 Dynamic valid
2 Static valid
When user selects dynamic voltage regulation, fast dynamic voltage regulation can inhibit form increasing
current cause by DC voltage in motor deceleration. But it easy brings current resonance.
For getting good performances in vector mode, please set AVR available (F4.14 is 1 or2).
F4.15 Energy-saving running
Setting range0 ~ 1
0Valid
1Invalid
When F4.15 is 0, inverter will detect motor load automatically and real-time rectify output voltage.
Energy-saving running works high efficiency under occasions that the range of freq. is small and the range of
speed is wide.
Because of fan or pump have a specified relationship with rotate speed, it can compendiary judge load state
according output freq. Low-freq. torque curve V/F is a typical example in energy-saving running. When user
takes low-freq. torque curve (F0.1 is 1 or2), function of energy-saving running neednt valid.
F4.16 Dead time of FWD&REV
The parameter means that the duration at zero frequency when the inverter changes its running direction,
and it is shown as the following fig.6-21. FWD and REV dead time is set for the big inertia load which has
the mechanical dead zone.
Output frequency
t
[F3.10]
SUNFAR C320 59
F4.17
F4.18
F4.19
F4.20
F4.21
F4.22
Acceleration time 2
Deceleration time 2
Acceleration time 3
Deceleration time 3
Acc time 4/Jog Acc time
Dec time 5/Jog Dec time
Jog frequency has the highest priority. In any state, as long as Jog instruction is input, the inverter will
transit to run at Jog frequency according to the setting Acc and Dec time.
f
Acc/Dec terminal 1
Acc/Dec terminal 2
Acc/Dec
time 1
Acc/Dec
time 2
Acc/Dec
time 3
It defines rate that terminals UP/DW modify setting freq. Speed of F4.23 isnt controlled by Acc/Dec time.
F4.24 Start voltage of dynamic braking
F4.25 Action ratio of dynamic braking
Those parameters are valid for inverter with the inner brake unit. And they define the action parameter of
inner brake unit. When inner DC voltage of inverter is higher than the start voltage of dynamic braking, the
inner brake unit will act. If inverter connects external brake resistance, DC energy of inverter will be release
by it to decline DC voltage. When DC voltage declines to the certain value ([F3.19]-50V), inner brake unit of
inverter will be off, shown as Fig.6-23.
Brake unit action ratio is used for defining the voltage on brake resistor, and the voltage on brake unit is
Voltage PWP. Duty cycle equals brake action ratio. The ratio is larger, and the energy is consumed more
quickly, at the same time, the power of brake resistor is bigger. User can set parameter according to the
resistance and power of resistor and actual brake effect.
DC
Voltage
[F4.24]
[F4.24]-50V
Parameter F4.26
C320 Series of Sensorless Vector Inverter Operation Manual
60
SUNFAR C320
6.6
Multi-speed frequency 1
Multi-speed frequency 2
Multi-speed frequency 3
Multi-speed frequency 4
Multi-speed frequency 5
Multi-speed frequency 6
Multi-speed frequency 7
Multi-speed frequency 8
F5.9
F5.10
F5.11
F5.12
F5.13
F5.14
F5.15
F5.16
Parameter F5.0 is multi-speed running mode. It is used for setting basic characteristics of multi-speed
running.
The first part of LED(form right to left)Simple PLC selection
0Simple PLC is invalid.
1Simple PLC is valid. If priority of freq. channel is permit after starting, inverter will run at simple PLC state.
2Simple PLC is conditional valid. If external X1~X6 terminals is valid (F3.0~F3.5 is set as 22), inverter will
run at simple PLC state.
Priority of freq. channel is shown as following table.
SUNFAR C320 61
Priority
High
Low
Setting freq.
1
JOG freq.
PID output
62
SUNFAR C320
Freq.
Freq.
Mode 1
[F5.3]
[F5.8]
[F5.3]
[F5.14]
[F5.2]
[F5.1]
Stop
[F5.8]
[F5.13]
[F5.1]
t
[F5.9]
[F5.6]
[F5.10]
[F5.11]
[F5.5]
[F5.9]
[F5.11]
[F5.16]
[F5.16]
Mode 2
[F5.3]
Stop
[F5.8]
Instruction
[F5.1]
Each stage
OC output
[F5.9]
[F5.11]
Whole Cyc
[F5.16]
OC output
Setting range0 ~ 1
When F6.0 is set as 1, inverter will automatic determine whether connect with motor. When motor is
connecting with inverter, inverter will work. Or inverter will wait.
C320 Series of Sensorless Vector Inverter Operation Manual
SUNFAR C320 63
Applied motor havent stop completely but it need restart, function of Detect speed
and restart (code F4.0) need set. Or it will cause inverter fault.
Setting range0 ~ 2
Setting range0.2 ~ 20.0s
F6.3
F6.4
The parameter defines the counting action of internal counter, and the clock terminals of counter is selected
by parameter F1.6.
The counting value of counter for the external clock reaches the value appointed by parameter F3.5, and the
corresponding Terminal OC outputs a valid signal of same width with the external clock cycle.
When the counting value of counter for external clock reached the value appointed by Parameter F6.3, the
corresponding Terminal OC will output the valid signal, Go on counting to the value provided by parameter
F6.4, which will lead to reset and the output valid signal will be withdrawn.
The clock cycle of counter should be over 5ms and the min width should be 2ms.
[F6.3]
[F6.4]
Pluse
OC
OC
F6.5
F6.6
F6.7
F6.8
Skip freq. 1
Amplitude accumulation of Skip freq. 1
Skip freq.2
Amplitude accumulation of Skip freq.
It is used for avoiding resonance point of mechanical load. Shown as fig. 6-27.
Adjusted setting freq.
Skip freq. 2
Skip freq. 1
64
SUNFAR C320
This parameter is used for confirming the diapaly value of running linear speed and setting linear speed, and
displaying other value being positive ratio with the output frequency.
Running linear velocityd-10= F6.9 output frequency (d-0)
Setting linear velocityd-11= F6.9 Setting frequency (d-6)
Setting range0 ~ 11
Setting range0 ~ 11
This parameter is used for confirming display content of operation panel in state monitor mode.
F6.14 Query or modify parameters
Setting range0 ~ 2
SUNFAR C320 65
Dont modify this parameter without our permission.
F6.18 User password
Preset freq. of wobble freq. is running freq. before inverter is in or out wobble freq. mode.
When [F7.0]###1inverter will start and run in preset freq. of wobble freq., then run in wobble freq. mode
after the setting time of F7.2.
When [F7.0]###2 and the terminals of wobble freq. is valid (F3.0~F3.5 is 4)the inverter will run in wobble
freq. mode. When [F7.0]###2 and the terminals of wobble freq. is invalid, inverter will output preset freq.
[F7.1].
F7.3
66
SUNFAR C320
When freq. arrives the upper limit freq. , the freq. will fast decline. Or when freq. arrives the lower limit freq.,
the freq. will fast ascend. Jumping freq. is amplitude, which freq. is ascending or declining. Shown as fig6-26.
Actual jumping freq. = [F7.4]Amplitude of wobble freq. [F7.3]
F7.5 Triangular rise time
F7.6 Triangular fall time
F7.5 defines the running time from lower limit freq. to upper limit freq. of wobble freq., namely Acc time
F7.5 defines the running time form upper limit freq. to lower limit freq. of wobble freq., namely Dec time
The sum of F7.5 and F7.6 is running cycle of wobble freq.
F7.5 and F7.6 define slope of Acc and Dec in wobble freq.
Center freq. of wobble freq. is central value of output freq. when inverter is in wobble freq. mode. The sum
of setting value of F7.7 and F0.1 is actual center freq.
Running process of wobble freq. is shown as fig6-28.
Running freq.
Running freq.
Amplitude of
wobble freq.
[F7.7]
[F7.1]
Amplitude
of wobble
freq.
[F7.5]
Break in wobble
freq. and restart
[F7.1]
[F7.6]
External freq. set by [F0.1]
Running instrument
t
[F7.2]
Wobble freq.
1Reactor
SUNFAR C320 67
frequency as 0, and it has margin between PID setting and feedback, the output phase sequence and
motors reversion would change. That is to say, the external terminal and PID controller decide the motors
reversion together under this control mode. Please refer to fig 6-31.
PID feedback
PID feedback
Warp limit [F8.9]
PID setting
Time
Time
Output frequency
Under the ambipolar
PID control mode,the
output frequency would
change the phase
sequence
Output frequency
Under monopole PID
control mode, when
output frequency reduces
to o, the direction would not
change.
Time
Time
Reserved.
Parameters F8.3 and F8.4 define the upper and lower limit value of PID setting. Parameters F8.5 and F8.6
define corresponding relation with PID feedback value. Shown as fig.6-32.
68
SUNFAR C320
Expected feedback value
[F8.6]
[F8.5]
PID setting value
[F8.3]
[F8.4]
Fig.6-32 Relation between PID fixed value and expected feedback value
The parameter is the allowable deviation value relative to the setting max value. When the difference
between feedback value and the setting value is lower than this setting value, PID controller will stop. Shown
as fig.6-33.
This function is mainly suited for the system that has lower control precision and needs to avoid adjusting
frequently, for example, water-supply with constant pressure system.
f
PID action
PID feedback
[F8.9]
PID setting
PID action
Those parameters define freq. and running time of inverter before actual PID control is valid. In some control
systems, inverters will forcible output a certain freq. (F8.10) and keep it in setting time (F8.11) for controlled
object arrives fast targeted value. When controlled object almost arrives targeted value, PID controller will
be valid to improve response speed.
F8.12 long-distance manometer range
Setting range0.00120.000Mpa
It defines feedback value while inverter goes sleep state. When actual feedback value is bigger than setting
value and inverter arrives lower limit value, the inverter will go sleep.
F8.14 Reserved
SUNFAR C320 69
6.10
The first part of LED(form right to left) It is used for setting baud rate of serials communication.
0 Reserved
11200bps
2: 2400bps
3: 4800bps
4: 9600bps
5: 19200bps
To make sure both sides have the same baud rate, when client use serials communication.
The second part of LED To set data format of serials communication.
0Close
1 Even
2Odd
To make sure both sides have the same data format, when client use serials communication.
The third and fourth part of LED: Reserved.
F9.1 Local address
Setting range0 ~ 30
It defines waiting time, which is the time, receiving local correct code to send response data frames.
F9.3 Function setting of communication Auxiliary function
If the local doesnt receive correct data signals in regulate time, the communication is fault. Inverter will keep
on running or stopping according to setting of parameter F9.3.
F9.5 Linkage setting proportion
F9.6 Rectify channel of linkage setting proportion
It is used for setting proportion of output freq. between master and slave, when takes linkage setting control.
When F9.6 is 0, rectify channel of linkage setting proportion is invalid.
Slave freq. = Master freq. [F9.5]
When F9.6 is 1, 2,3 or 4, rectify channel of linkage setting proportion is valid.
Slave freq. = Master freq. [F9.5]value of rectify channel or the max value of rectify channel
F9.6 is used for selecting rectify channel.
Rectify channel 1Panel potentiometer
Rectify channel 2External voltage signal VC10 ~ 5V
Rectify channel 3External voltage signal VC20 ~ 10V
Rectify channel 4External current signal CC0 ~ 20mA
F9.7 Reserved
Setting range
360V ~ 460V
70
SUNFAR C320
It defines lower limit voltage which terminals P+ and P- are allow while inverter is working normally. For some
low voltage conditions, user can decrease under voltage protection level to ensure that inverter is running
normally.
FC.1 Over voltage limit level
Setting range
660V ~ 760V
It defines threshold of voltage stall protection while motor is decelerating. If DC voltage caused by
decelerating is beyond setting value of FC.1, deceleration time will automatic prolong. Shown as fig6-35.
f
Adjust Dec time
DC voltage
[FC.1]
t
Fig.6-35 voltage stalls protection in Dec speed
FC.2
It defines the max output current that is inverter permit. Whatever the operation mode is, inverter will adjust
output freq. to inhibit current within the range of regulation, when output current of inverter is beyond setting
value of FC.2.
FC.3
Reserved
FC.4
It is used for setting some coefficients with special function in running process. Generally, user neednt set.
The first part of LED(form right to left) Under voltage compensation intensity
The second part of LED Over voltage inhibit intensity
The third part of LED Over current inhibit intensity
The fourth part of LEDSelf-adapting braking torque adjust intensity
FC.5
Setting range
0000 ~ 0111
Function setting
Setting range
0000 ~ 0011
SUNFAR C320 71
0invalid
1Valid
Parameter F0.18 will invalid and user can modify all parameters. If user want to get new password, please
refer to our.
The second part of Le define active level of external control terminals
0It is valid when terminals are close.
1It is valid when terminals are open.
The third and fourth part of LEDReserved.
FC.7
Reserved
FC.8
Agency password
FC.9
FC.10
FC.11
Setting range
0~ 9999
They are closed loop control parameters about rotate speed and used for setting arithmetic of vector control.
Generally, they need modify by professional person.
FC.12
Setting range0 ~ 25
It is read-only parameter for user. Rectify coefficient of dead zone can be modify by parameter F1.20 only.
FC.13
Program version
Range2100 ~ 2199
It is read-only parameter.
72
SUNFAR C320
Faults
Probably Cause
1. Acceleration time is too short.
2. V/F curve is not suitable.
Fu.1
Over-current during 3. User start rotating motor, but doesnt set function
Acc
Fu.2
Fu.3
Over-current during
Dec
Solutions
1. Prolong the acceleration time
2. Descend the torque boost or adjust
the V/F curve
3. To set function of detect speed and
restart
4. To decrease voltage of torque boost
5. Check mains voltage
Prolong the deceleration time
Decrease load fluctuation
1. Check power supply
Fu.4
Acc
control terminal
Fu.5
Fu.6
Fu.7
Fu.8
2. Input-voltage is abnormal
running
Under-voltage
during running
Inverter protective
action
Over voltage at
stop
1. Check wiring
Fu.9
short-circuit
1.The output terminal of inverter grounds
Fu.10 Output ground
Fu.11 Interfere
2. The wire is too long between inverter and motor and the 2. Shorten the connection wire or reduce
carrier frequency is too high.
Inverter
Fu.12
over-loading
SUNFAR C320 73
Code
Faults
Probably Cause
Solutions
1. Reduce the load
condition.
3. Fan is damaged
Fu.15 Reserved
Peripheral
Fu.16
equipment
occur error
pertinent equipments
Fu.18 Reserved
Main contactor of
Fu.19 inverter is poor
contact
Fu.20
2. Replace contactor
4. Contract Us
error
Temperature
occur faults
Fu.29
2. Contactor is damaged.
Current detecting
Fu.21 sensor
Fu.22-
Contract Us
1. Check jack
2. Contract Us
Reserved
Contents
Monitor
Item
Contents
Monitor
Item
Contents
d-26
d-30
d-34
d-27
d-31
d-35
d-28
d-32
d-36
d-29
d-33
d-37
74
SUNFAR C320
7.3 Reset
Be sure to check the fault cause and exclude it before reset, otherwise, which may
lead to the inverter, the permanent damaged.
If the inverter can not be reset or occur the fault again after reset, please find out the
reason. Continuous reset will damage the inverter
Over-load or over-heat protective action should delay 5 minutes to reset.
When the inverter happens to the fault, you can reset the inverter to resume the normal
running by any way as follows:
I.
External reset input-terminal RST and CM terminal are closed, then off.
II. While the fault code is displayed, press
key.
III. Turn the power source off.
IV. It will send fault reset instrument by RS485 interface.
SUNFAR C320 75
8MAINTENANCE
As a result of ambient temperature, humidity, dust, vibration and aging of internal components of inverter, the
inverter will probably appear the potential problem during running. In order to ensure the inverter to run
steadily for a long time, the inverter should be checked up once at 3 or 6 months.
First of all, turn the inverters power off. And professional worker performs maintenance.
Time
items
Daily
Criterion
contents
1.Temperature,
Running
Environment
Humidity
2.Dust, gases
1.Installation
Cooling system
Inverter
Inspection
Periodic
Environment
blocked.
2. Fan in inverter
1.Vibration,
Temperature raise
2. Noises
1.Vibration,
Motor
Temperature raise
2. Noises
Input/output
Parameters
1. Input voltage
2. Output current
Input voltage
Moving-coil voltmeter
Output voltage
Rectifier-type voltmeter
O/I current
Tong-type ammeter
Inverter has done the electric insulating experiment before leave-factory, so user dont need to do the
withstand voltage test.
Do the insulation test to the inverter if necessary, all of I/O terminals must be connected in short-circuit (R,
S, T, U, V, W, P, P-, PB). Strictly prohibited from doing the insulation test for the single terminal. Please use
500V Meg-ohmmeter to perform this test.
Control circuit can not be used the Meg-ohmmeter to test.
For insulation test to motor, the connection wire between motor and inverter should be disassembled.
76
SUNFAR C320
8.3 Storage
If the inverter isnt used for a long time, please notice the following items:
(1) To avoid storing the inverter at the environment with high-temperaturehumidity, vibration or metal dust,
and ensure the well ventilation.
(2) If the inverter is not used for a long time, it should be energized to resume the capability of electrolyte
capacitor once at 2 yearsat the same time, check the functions of inverter. When the inverter is electrified,
its voltage should be increased by an autotransformer step by step and the time should not be less than 5
hours.
If inverter is not used for a long time, the performance of internal filter capacitor will descend.
Guarantee time of this inverter is 18 months (From the day of purchase). In guarantee time, if the inverter
occurs fault or be damaged in normal usage, our company will provide the free repair service or replacement.
In guarantee time, if the faults are caused by the following cases, certain service cost would be charged.
Malfunction is caused by not following the operation manual or over using the standard specification;
Malfunction is caused by repairing without admision.
Malfunction is caused by the bad-storage.
Malfunction is due to application of inverter for abnormal functional needs.
Damage is caused by fire, salt-corrode, gas-corrode, earthquake, storm, flood, lightning strike, voltage
abnormal or other force majored.
Even if over guarantee time, our company will provide the paid service forever.
SUNFAR C320 77
9. USAGE EXAMPLE
9.1 Panel on-off control, Panel potentio- meter setting frequency and V/F control
9.1.1 Parameters setting
1. When F0.0 is 0, V/F method is valid.
2. When F0.4 is 00#0, panel control is valid.
3. When F0.1 is 3, panel potentiometer is valid.
9.1.2 Basic wiring
Power
Supply
3-phase Breaker
Motor
U
V
W
E
R
S
T
FWD
Direction
Control
CM
Voltmeter (0~10V)
AO1
AO2
GND
Voltmeter (0~10V)
9.1.3 Operation
Press
key to start the inverter, and then rotate the button of panel potentiometer in clockwise to
increased setting frequency step by step. Contrarily, rotate in anti-clockwise to decreased setting frequency
step by step.
Press
key to stop the inverter.
9.2 External control mode, external voltage setting frequency and V/F control
9.2.1 Parameters setting
1. When F0.0 is 0, V/F method is valid.
2. When F0.4 is 00#1, external terminals control is valid.
3. When F0.1 is 5, external voltage VC20~10Vis valid.
9.2.2 Basic wiring
Power
Supply
3-phase Breaker
FWD
FWD
REV
REV
CM
VS
VC1 (0~5V)
10K
VC2 (0~10V)
GND
U
V
Motor
W
E
AO1
AO2
Voltmeter0~10V
Voltmeter0~10V
GND
78
SUNFAR C320
9.2.3 Operation
FWD-CM is offthe motor will running forward. REV-CM is off, the motor will running backward. FWD-CM and
REV- CM are off or on at the same time, the inverter will stop.
Setting frequency is set by external voltage signal VC2.
Control method of terminals FWD and REV is set by parameter F0.5.See the explanation
about parameter F0.5.
3-phase Breaker
R
S
T
FWD
FWD
REV
REV
CM
Multi-speed
Control
terminals
U
V
W
E
X1
X2
X3
Motor
AO1
AO2
GND
Voltmeter0~10V
Voltmeter0~10V
9.3.3 Operation
FWD-CM is offthe motor will running forward. REV-CM is off, the motor will running backward. FWD-CM and
REV- CM are off or on at the same time, the inverter will stop.
If X1, X2 and X3 are all opened with CM, the multi-speed running is invalid. The inverter will run as the setting
instruction speed. (The setting frequency channel is selected by parameter F0.1)
If one terminal or all of X1, X2 and X3are connected with CM terminal, the inverter will run as the multi-speed
frequency selected by X1, X2 and X3.
9.4 Panel on-off controlPanel potentiometer setting frequency and linkage control
with inverters
9.4.1 Parameters setting
Master setting
1. Freq. setting channel is panel potentiometer mode. Namely F0.1 is 3.
2. Operation channel selection is panel control, namely F0.4 is 00#0.
3. Communication setting (Parameter F9.0) is default.
4. If F9.3 is 0001, the inverter is master.
Slave setting
1. Freq. setting channel is RS485 interface. Namely F0.1 is 2.
2. Operation channel selection isRS485 interface. Namely F0.4 is 00#2.
3. Communication setting (Parameter F9.0) is default.
4. If F9.3 is 0000, the inverter is slave.
C320 Series of Sensorless Vector Inverter Operation Manual
SUNFAR C320 79
5.
6.
Power
Supply
3-phase Breaker
Motor
U
V
R
S
T
W
E
Host
A
RS485
B
3-phase Breaker
Power
Supply
Motor
U
V
R
S
T
Guest
VS
VC2
GND
A
RS485
B
3-phase Breaker
Power
Supply
Motor
U
V
R
S
T
Guest
VS
VC2
GND
A
RS485
B
9.4.3 Operation
Running freq. of slave has a certain proportion with masters. Linkage setting proportion is set by parameter
F9.5.
In this example, freq. proportion of master and slaves can get across by VC1 channel.
80
SUNFAR C320
SUNFAR C320 81
There are five kinds of baud rate, 1200bps, 2400 bps, 4800 bps, 9600 bps and 19200 bps.
2.2.3. Communication mode
1 Point to point communication mode, which is master Polling and slave Responding.
2 Setting the serial interface communication parameters by the keypad of inverter. These parameters
include local address, baud rate and data format.
Master must be set the same baud rate and data format with the inverter.
10
11
12
Setting
Setting
Setting
Setting
Data
Data
Data
Data
33
38
30
30
10
11
12
Setting
Setting
Setting
Setting
Data
Data
Data
Data
38
00
DataASC
2
DataHex
2.3.1.
0
1
2
3
4
5
6
7
8
Definition
Header
Slave addr.
Slave addr.
Slave addr
Type of order
Operation order
Order area
Operation order
Type of data
Data addr.
Data addr.
Addr. area
Sending Sequence
9
10
11
12
13
14
15
16
17
Definition
Setting data
Setting data
Setting data
Data area
Setting data
Check sum
Check sum
Check sum
Check area
Check sum
Tail
0DH
82
SUNFAR C320
2.3.2
Definition
Sending Sequence
Definition
0
Header
9
Running data
1
Slave addr.
10
Running data
Slave addr.
Data area
2
Slave addr
11
Running data
3
Slave responding
12
Running data
4
Operation order
13
Check sum
Responding area
5
Operation order
14
Check sum
Check area
6
Type of data
15
Check sum
7
Data addr.
16
Check sum
Address area
8
Data addr.
17
Tail
0DH
2.4. Message data code
2.4.1. Header
This communication protocol defines that both 2AH (ASC code of character * ) and 5AH are available.
When header is 2AH, all of data behind header is ASC code. When header is 5AH, all of data behind
header is hex code and invalid byte fill 0. Unaided headers of 2AH and 5AH arent rightful header. There
need waiting time above five bytes before sending header.
2.4.2. Slave address
Slave address is inverter address. The address range of slave machine is 0~30, 31 (1FH) is broadcast
communication address.
2.4.3. Type of order
Type of order is only in master command frame and defines task of the data in this frame. Length of each
frame is different according to different order. Type of order is shown as following table.
Data
Operation
Modify code parameter in RAM, it will not save after power down
6F
Reserved
Operation
Data
Operation
00H
Invalid instrument
10H
01H
11H
02H
12H
03H
Stop
13H
04H
14H
05H
15H
06H
16H
20H
30H
Reserved
21H
31H
Reserved
SUNFAR C320 83
When user need not send operation order, please send invalid order 00H.
Definition
Data
Definition
Data received form master is beyond the permission
range
9F
Reserved
Header
Slave
address
Definition
Slave
Slave
address responding
Slave address
10
Check
Sum
Check
Sum
Check
Sum
Check
sum
Tail
Order/responding area
Check area
0DH
Operation
DC voltage of slave is not ready
Data
10H
Operation
Reserved
01H
11H
02H
12H
03H
Slave is stop
13H
04H
14H
05H
15H
06H
Reserved
16H
20H
21H
Slave is emergency
When slave occurs fault (data of state feedback is 20H), the seventh and eighth of feedback rata frame is
fault code.
84
SUNFAR C320
3.
Slave
addr.
Operation Operation
order
order
Data
Type
Check
Sum
Slave responding
10
11
12
Header
Character information
Slave addr.
10
Character information
Slave addr
Tail
Sending Sequence
0
2
13
Slave responding
11
Character information
12
Character information
State feedback
13
Check sum
State feedback
14
Check sum
Data type
15
Check sum
Character information
16
Check sum
Character information.
17
Tail
Slave will give different character information to master according to different data type in master message.
Data Type (master sending)
0
1
2
3
4F
10
11
12
Voltage level
Power
Power
Power
Power
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Master
Setting freq. of
control information
control
master
Reserved
For example, if data type is 0, slave return 400185. 4 means voltage level.
0 means Character information. 0185 means power, 18.5Kw.
2Orderis used to read running parameter of slave
Master
Sending Header
Slave
Slave
addr.
addr.
3
1
Operation Operation
order
order
6
0
Data
Data
subentry subentry
Slave responding
10
11
12
Sum
Sum
Sending Sequence
Header
Running data
Slave addr.
10
Running data
Slave addr.
11
Running data
Slave responding
12
Running data
State feedback
13
Check sum
Sum
13
Tail
SUNFAR C320 85
5
State feedback
14
Check sum
15
Check sum
Data subentry
16
Check sum
Data subentry
17
Tail
Data subentry
d-0
00
Output frequent
d-1
.
.
d-15
.
..
d-37
01
.
..
15
.
..
37
Output current
.
..
External pulse input
.
..
Temperature of module of last fault
See the explanation about state monitor parameter in the fourth chapter.
Slave
addr.
Slave
addr.
Data
Addr.
Data
Addr.
Slave responding
10
11
12
Sending Sequence
Header
Parameter data
Slave addr.
10
Parameter data
Slave addr
11
Parameter data
Slave responding
12
Parameter data
State feedback
13
Check sum
State feedback
14
Check sum
Data type
15
Check sum
Data addr.
16
Check sum
Data addr.
17
Tail
13
Tail
86
SUNFAR C320
Sending Sequence
Master Sending
Header
Setting data
Slave addr.
10
Setting data
Slave addr
11
Setting data
3 or 5
12
Setting data
Operation order
13
Check sum
Operation order
14
Check sum
Data type
15
Check sum
Data addr.
16
Check sum
Data addr.
17
Tail
Slave responding
Sending Sequence
Header
Setting data
Slave addr.
10
Setting data
Slave addr
11
Setting data
Slave responding
12
Setting data
State feedback
13
Check sum
State feedback
14
Check sum
Data type
15
Check sum
Data addr.
16
Check sum
Data addr.
17
Tail
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FC
FE
FF
FH
FL
FP
Data type
For example, data address of F0.8, F1.8 and F#.8 are 8. But data type of them is different.
AttentionWhen slaves dont accomplish order form master, setting data is 0000.
5Orderis used to send control order.
It is fit for routine operation for inverter.
Master Sending
Header
1
2
Sending Sequence
Setting data
Slave addr.
Setting data
Slave addr
10
Check sum
11
Check sum
Operation order
12
Check sum
Operation order
13
Check sum
Setting data
14
Tail
Slave responding
Sending Sequence
Setting data
Header
Running data
Slave addr.
10
Running data
Slave addr.
11
Running data
SUNFAR C320 87
3
Slave responding
12
Running data
State feedback
13
Check sum
State feedback
14
Check sum
15
Check sum
Monitor item
16
Check sum
Monitor item
17
Tail
Setting data in master sending is setting freq., which is send form master to slave.
Setting data in slave responding is running parameter, which is send form master. It is set by parameter
F6.12.
Refer to the explanation about list of parameter in chapter five.
4. Usage example
4.1. Order
To read slave model of 0#.
master will send
2A 30 30 30 30 31 30 30 30 30 31 38 31 0D
5A 00 00 00 00 01 00 00 00 00 00 00 01 0D
Slave will respondInverter with 380V and 2.2KW4
2A 30 30 30 30 31 30 34 30 30 30 32 32 30 32 34 39 0D
5A 00 00 00 00 01 00 04 00 00 00 00 22 00 00 00 27 0D
4.2. Order
To read running parameter of 0# slavenamely read d.0, output freq.
master will send
2A 30 30 31 30 31 30 30 30 30 31 38 32 0D
5A 00 00 01 00 01 00 00 00 00 00 00 02 0D
Slave will respondSetting freq. is 9.99Hz
2A 30 30 30 30 31 30 30 30 33 45 37 30 32 36 30 0D
5A 00 00 00 00 01 00 00 00 00 00 03 E7 00 00 00 EB 0D
4.3. Order
To read code parameter of 0# slavenamely parameter F0.1
master will send
2A 30 30 32 30 31 30 30 31 30 31 38 34 0D
5A 00 00 02 00 01 00 00 01 00 00 00 04 0D
Slave will respondsetting freq. of RS485 input channel
2A 30 30 30 30 31 30 30 31 30 30 30 32 30 32 34 34 0D
5A 00 00 00 00 01 00 00 01 00 00 00 02 00 00 00 04 0D
4.4. Order
To modify code parameter of 0# slave (modify parameter F4.0)
master will send(To set detect and restart mode)
2A 30 30 33 30 31 34 30 30 30 30 30 31 30 32 34 39 0D
5A 00 00 03 00 01 04 00 00 00 00 00 01 00 00 00 09 0D
Slave will respond(Parameter is de modified)
2A 30 30 30 30 31 34 30 30 30 30 30 31 30 32 34 36 0D
5A 00 00 00 00 01 04 00 00 00 00 00 01 00 00 00 06 0D
4.5. Order
C320 Series of Sensorless Vector Inverter Operation Manual
88
SUNFAR C320
SUNFAR C320 89
Appendix
OPTIONS
1. Operation panel
Sometimes users need to take operation panel out of the inverter or control cabinet, if users purchase panel
base and wire, it is convenient to install and debug. Wire between operation panel and inverter should be
less than 15m. If the length is above 15m, long-distance control line is needed.
1.1 Appearance of panel base
It is recommended that user take Fig-B and Fig-D Hole dimension of panel base.
90
SUNFAR C320
2.
Brake resistance
Applied motorKw
Brake resistance
Brake torque
C320-2S0015
1.5
0.4
75
100
C320-2S0022
2.2
0.6
50
100
C320-2S0037
3.7
35
100
C320-4T0015
1.5
0.5
300
100
C320-4T0022
2.2
0.65
200
100
C320-4T0037
3.7
1.0
125
100
C320-4T0055
5.5
1.5
85
100
C320-4T0075
7.5
2.0
65
100
C320-4T0110
11
2.5
50
100
C320-4T0150
15
3.6
35
100
C320-4T0185
18.5
4.5
30
100
C320-4T0220
22
5.5
25
100
C320-4T0300
30
6.5
20
100
C320-4T0370
37
8.5
15
100
C320-4T0450
45
12
12
100
C320-4T0550
55
15
10
100
C320-4T0750
75
18
100
C320-4T0900
90
18
100
C320-4T1100
110
25
100
C320-4T1320
132
30
100
C320-4T1600
160
36
100
C320-4T1850
185
42
3.5
100
C320-4T2000
200
45
100
C320-4T2200
250
50
100
C320-4T2500
C320-4T2800
If the braking effect is not obvious, please decrease brake resistance and increase power of brake resistance
according to proportion.
SUNFAR C320 91