Annex B
Annex B
Annex B
No reinforcement
pilecaps:
1.
2.
3.
4.
Consultants Response
Tender Query
S/N
details
for
ANNEX B
the
2E1
2F1
3D
3E
following Please
refer
to
Tender
Corrigendum No. 1, structural
drawing no.: 14.00050/PC
Rev. A. (Option I) and
14.00050/PC Rev. A. (option
II)
ANNEX B
003159/SA/201.
003159-SA-202 Rev. A.
Please provide all the A/C level drawing for option Please refer to Tender drawing
2.
list no.: C-SG003159/ME/1100
ANNEX B/ 2
ANNEX B
WOODWORK and drawing
no.: C-SG-003159/AD/802 for
detail.
Kindly advise whether the fire rated roller shutter Yes, thermal Insulation is
requires insulation.
required on both sides to
manufacturer details.
10
Kindly provide details and specification for the Supply of chairs will be by
following chairs.
others.
ANNEX B/ 3
11
ANNEX B
Kindly provide dimension and specification for the These round table at
round table.
Classrooms are provided by
others.
Please refer to Tender
Corrigendum No. 2,
architectural drawing No.: CSG-003159/AD/600 Rev. A.
12
13
ANNEX B/ 4
ANNEX B
14
15
Refer to 3rd storey plan, it stated at vinyl flooring, Therapist Office floor finish is
however, according to floor finishes plan, is 9mm to be homogenous tile.
thk non-slip homogenous tile.
Please refer to Tender
Corrigendum No. 2,
architectural specification
SECTION 09 06 00
SCHEDULE OF FINISHES.
ANNEX B/ 5
ANNEX B
16
We refer to the page PFP I/35 and PFP II/35 for Please refer to Tender
Option I & Option II - pricing for Preliminaries Corrigendum No. 1.
(Annex C I & C II) Item A - Security Deposit as
stated To be Priced in Final Summary".
Unfortunately, we can't find that any Final
Summary" page to price in our cost. Please
clarify?
17
ANNEX B/ 6
ANNEX B
18
19
20
Please advise live load & Superimposed dead SDL=2.7kPa for all Areas
load for every single floor.
except SDL = 4.4kPa for
Landscape/Wet Area and
SDL=7.5kPa for
Roof/kitchen/laundry/outdoor
space.
All those above mentioned
loading are without inclusive of
Hollow Core Slab structural
topping 75mm thick where at
Hollow Core Slab Areas.
Live Load information is
provided at each floor plan
ANNEX B/ 7
ANNEX B
inside
No. 1.
Tender
Corrigendum
21
Please advise the PC supply rate for all the tiles There will be no PC supply
as clouded.
rates for this contract.
Contractors are to price in
accordance to the drawings
and specifications.
22
23
Kindly provide the chair detail for system furniture Supply of chairs will be by
type A, B and C.
others.
24
25
ANNEX B/ 8
ANNEX B
26
27
Please
refer
to
Tender
Corrigendum No. 2, structural
drawing no.: 14.00050/1/SD1
REV A and 14.00050/1/SD2
REV B and 14.00050/B/SD1
REV A
28
Please
refer
to
Tender
Corrigendum No. 2, structural
drawing no.: 14.00050/B REV
B and 14.00050/1/SD2 REV B.
29
Please
refer
to
Tender
Corrigendum No.2 Drawing,
structural
drawing
no.:
14.00050/URS1 REV A and
14.00050/ URB1 REV A and
ANNEX B/ 9
ANNEX B
14.00050/LW REV
14.00050/UR REV B
30
and
Kindly provide the mesh detail for concrete Typical mesh details, required
topping above the hollow core slab
Hollow core type are provided
under Hollow core slab
details. Loading information
with HCS Area Extent is
clearly shown on each plan.
Hollow core slab design with
required strands reinforcement
with necessary precast topping
details with required mesh are
under tenderers specialist PE
design. The tenderer and
specialist tenderer PE are to
make sure to submit the
proposal and price in with
necessary
details
and
design to cater for structural
requirement of provided plan
and
specification.
Any
deviation /additional cost due
to design requirement will not
be accepted after tender
award. All designs that are
assumed
to
be
fully
ANNEX B/ 10
ANNEX B
compliance
with
tender
requirement shall be deemed
to be included in your tender
offer.
31
32
Kindly advise the slab top reinforcement (example To refer to slab reinforcement
refer to below) is distributed for the full length or plan for slab reinforcement
follow the typical detail (refer to below), which is extent.
only 0.2 Lx.
ANNEX B/ 11
ANNEX B
33
34
Please confirm CU capcity needed 35.4 and 41.3 Yes please follow CU capacity
for activity space (L).
as per stated in Tender
Corrigendum No. 2, ACMV
drawing no.: C-SG003159/AC/403 Rev. A & C-
ANNEX B/ 12
ANNEX B
SG-003159/AC/1403 Rev. A.
35
36
37
38
39
40
Please confirm total sets for system furniture type We confirm that the quantity
A to 2nd sty; BQ shows 17 while dwg shows 16 for system furniture type A to
2nd storey is 17 sets as
ANNEX B/ 13
ANNEX B
only.
41
42
Please confirm total sets for system furniture type We confirm that the quantity
B to 3rd sty; BQ shows 11 while dwg shows 2 for system furniture type B to
only.
3rd storey is 11 sets as shown
in the Schedule of Works.
43
are
not
to
be
Please advise thickness of rubber wall tile- 15mm Thickness of rubber wall tile is
as per detail in dwg AD 425 or 12mm thk as per to be 12mm.
wall sched dwg AD 424
45
46
Please advise floor finish to smoke stop lobby- Smoke Stop lobby floor finish
smooth screed finish as per SOF or screed with to be in concrete screed with
hardener as per floor finish plan.
floor hardener.
Please
refer
to
Tender
Corrigendum
No.
2,
architectural
specification
SECTION 09 06 00
SCHEDULE OF FINISHES.
ANNEX B/ 14
ANNEX B
Please advise CEILING finish to dining area at 1st Dining area ceiling at 1st
sty- skimcoat with paint as per SOF or mineral Storey is to be 15mm thick
fiber board as per ceiling finish plan.
mineral fibre board.
Please
refer
to
Tender
Corrigendum
No.
2,
architectural
specification
SECTION 09 06 00
SCHEDULE OF FINISHES.
48
Please advise wall finish to M&E shafts; 3mm Wall finish to M&E shafts are
skim with paint as per wall types plan or cement to be 5mm skim coat with
sand plaster as per SOF.
paint.
WT1 and finishes for M&E
shafts as showing in drawing
C-SG-003159/AD/424.
49
50
51
ANNEX B/ 15
52
53
ANNEX B
54
ANNEX B/ 16
ANNEX B
WATERPROOFING
ROOFING. .
55
AND
Please advise whether there is any size different There are no size different
for window type W2 and W2a.
between window type W2 and
W2a.
Please refer to architectural
drawing
no.:
C-SG003159/AD/301,
window
schedule for 2nd storey for
details.
56
57
58
Please advise the door type for the clouded at This door type is D14 for fire
2nd storey.
extinguisher enclosure.
59
ANNEX B/ 17
Tender
ANNEX B
60
Please provide detail of stainless steel shelf in the The stainless steel shelf to be
toilets.
in size of 650mm x 150mm x
1mm
(thick).
Perforated
pattern to SO/SO Reps
selection.
61
Please advise whether the door type clouded This door type is to be D2.
should be type D1 for 10th / 8th storey.
62
Please advise 10th / 8th storey window type W6b We confirm that the quantity
is 26 nos and W10a is 9 nos.
for window type W6b 28 nos
and W10a - 10 nos are correct
as per indicated in the
drawings.
63
64
ANNEX B/ 18
Please
refer
to
Tender
Corrigendum
No.
1,
architectural drawing No.: CSG-003159/AD/311, 312, 313
& 314.
ANNEX B
65
66
Please confirm female toilet 1-1 has 4 or 3 basins. Female toilet 1-1 has 3 basins
Discrepancy on plan against elevation 6 and as showing in the plan;
sanitary schedule.
67
68
Please
refer
to
Tender
Corrigendum No. 2, Sanitary
Wares, Fittings & Accessories
Schedule.
69
Please
refer
to
Tender
Corrigendum
No.
2,
architectural
specification
SECTION 22 42 00
SANITARY FIXTURES AND
FITTINGS.
70
Please
refer
to
Tender
Corrigendum
No.
2,
architectural
specification
SECTION 22 42 00
SANITARY FIXTURES AND
FITTINGS.
71
72
ANNEX B/ 19
Please
refer
to
Tender
Corrigendum No. 2, structural
drawing no.: 14.00050/4B1
REV A
ANNEX B
73
Refer to above part print. Please advise which Parapet height is 1200mm
parapet height to follow.
from finished floor level and
1400mm from structural level.
74
ANNEX B/ 20
to
Tender
No.
2,
ANNEX B
architectural
specification
SECTION 22 42 00
SANITARY FIXTURES AND
FITTINGS.
75
Option 2 cut off pile head for preliminary pile The correct cut off pile head
should be 1000mm diameter.
size for preliminary pile (Option
II)
should
be
1000mm
diameter. Please refer to
revised Schedule of Works
issued as part of Tender
Corrigendum No. 2.
76
77
78
79
Refer to Drawing 113 & 114 attached, please There are no screens required
assist to advise the type of finishes for the area at the clouded area.
circled in red.
ANNEX B/ 21
80
ANNEX B
81
ANNEX B
plan and pile cap details.
3 PILE GROUP Please refer to
Tender Corrigendum No. 1,
structural drawing no.: Please
refer to Tender Corrigendum
No. 1, structural drawing no.:
14.00050/PC Rev. A. (Option
I) and 14.00050/PC Rev. A.
(option II)
82
83
84
GFA
Scope of work (particular specifications)
Details of project team
CONQUAS score
KTP
ANNEX B
is 84.86 for the whole
Works.
85
86
87
88
Refer to Schedule of Finishes (page AS/361), the Dining area ceiling at 1st
ceiling finishes for Dining Area (skim coat) is not Storey is to be 15mm thick
tally with ceiling finishes drawings (mineral fibre mineral fibre board.
board). Kindly advise which to follow.
Please
refer
to
Tender
Corrigendum
No.
2,
architectural
specification
SECTION 09 06 00
ANNEX B/ 24
ANNEX B
SCHEDULE OF FINISHES.
89
90
Please provide the details for operable partitions Please refer to architectural
(at 2nd storey)
drawing
no.:
C-SG003159/AD/427 and C-SG003159/AD/901.
91
There are a few items that contradict as below:(a) Lift interior Finishes:
ANNEX B
93
94
95
2VB 5,2VB6,2VB8
Please
refer to Tender Corrigendum
No.1, structural drawing no 14.00050 /2B2 REV A
3HB30,3HB31 Please refer to
Tender Corrigendum No.1,
structural
drawing
no
14.00050 /3B1 REV A
3-HB 24 Please refer to
Tender , structural drawing
14.00050 /3B1
4HB 4 Please refer to Tender ,
structural
drawing
ANNEX B/ 26
ANNEX B
14.00050/4B1
4HB 47, 4HB 48 Please refer
to Tender Corrigendum No.2,
structural drawing no 1400050/4B1 REV A
T-HB 27A Please refer to
Tender Corrigendum No.2,
structural drawing no 1400050/5,6,7-B1 REV A
T-8&9 HB 28, Please refer to
Tender, structural drawing
14.00050/8-9B1.
10HB24 Please refer to
Tender Corrigendum No.2,
structural drawing no -1400050/10B1 REV A
10-HB28 Please refer to
Tender, structural drawing
14.00050/10B1
10-HB40
AND
10-HB40A
Please
refer
to
Tender
Corrigendum No.2, structural
drawing no 14-00050/10B1
96
Please
refer
to
Corrigendum No. 2.
97
Please
refer
to
Tender
Corrigendum No. 2, structural
drawing no.: 14.00050/4B1
REV A
( 4-HB18 4-HB26 )
98
ANNEX B/ 27
Tender
ANNEX B
Kindly advise the material of window grille is steel, All material of window grille is
aluminium or other material.
steel with powder coated
finish.
ANNEX B/ 28