Catalog Titanex H07RN-F
Catalog Titanex H07RN-F
Catalog Titanex H07RN-F
Description
Application
TITANEX flexible cable is intended for installations with moving
equipment, electric appliances and for building sites. The cable may be
rated 0,6/1 kV where the installation has built-in protection and for motors
in lifting appliances - machine tools - etc.
This cable can be used in refrigerating installations.
Installation
This cable can be installed in open air or be buried but with extra
mechanical protection.
Conductors laid up
Assembled conductors.
Marking
USE <HAR> N (x ou G) S TITANEX
N = number of cores
G = with Green-Yellow
x = without Green-Yellow
S = section in mm
Nota
Max continuous operating conductor temperature in normal use :
Standards
International HD 22.4; HD
516; IEC 60245-4 type 66
National NF C 32-102-4
Lead free
Yes
Mechanical resistance to
impacts
Cable flexibility
Chemical resistance
Water proof
Flexible
Accidental
Good
Very good
Operating temperature,
range
-25 .. 55 C
Page 1 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Lead free
Yes
Mechanical resistance to
impacts
Cable flexibility
Chemical resistance
Water proof
Flexible
Accidental
Good
Very good
Operating temperature,
range
-25 .. 55 C
Page 2 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Single Core
Cross
section
mm
1.5
2.5
4
6
10
Voltage drop,
single phase
V/A.km
23.3
14.0
8.7
5.9
3.4
Max. outer
diam.
mm
7.1
7.9
9.0
9.8
11.9
Min. outer
diam.
mm
5.7
6.3
7.2
7.9
9.5
Approx. weight
(kg/km)
kg/km
50
66
94
109
182
Page 3 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Voltage drop,
single phase
V/A.km
2.2
1.4
1.04
0.75
0.56
Max. outer
diam.
mm
13.4
15.8
17.9
20.6
23.3
Min. outer
diam.
mm
10.8
12.7
14.3
16.5
18.6
363
416
475
559
637
833
0.36
0.31
0.28
0.23
0.2
0.16
28.6
31.4
34.4
38.3
41.9
52.0
22.8
25.2
27.6
30.6
33.5
41.3
Approx. weight
(kg/km)
kg/km
256
369
482
662
895
1144
1430
1740
2160
2730
3480
5700
Two cores
Cross
section
mm
1
1.5
4
6
10
16
25
Voltage drop,
single phase
V/A.km
39.4
27.0
10.1
6.7
3.8
2.5
1.68
Max. outer
diam.
mm
10.0
11.0
15.1
16.8
22.6
25.7
30.7
Min. outer
diam.
mm
7.7
8.5
11.8
13.1
17.7
20.2
24.3
Approx. weight
(kg/km)
kg/km
99
111
238
279
538
744
1074
Three cores
Cross
section
mm
1
1.5
1.5
2.5
2.5
6
10
16
25
35
50
70
95
120
150
185
Voltage drop,
single phase
V/A.km
39.4
27.0
27.0
16.2
16.2
7.0
4.0
2.5
1.7
1.21
0.87
0.64
0.5
0.4
0.35
0.3
Max. outer
diam.
mm
10.7
11.9
11.9
14.0
14.0
18.0
24.2
27.6
33.0
37.1
42.9
48.3
54.0
60.0
66.0
72.0
Min. outer
diam.
mm
8.3
9.2
9.2
10.9
10.9
14.1
19.1
21.8
26.1
29.3
34.1
38.4
43.3
47.4
52.0
57.0
Approx. weight
(kg/km)
kg/km
117
134
134
195
195
346
663
924
1345
1760
2390
3110
4170
5080
6220
7730
Page 4 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Voltage drop,
single phase
V/A.km
0.26
0.22
Max. outer
diam.
mm
82.0
90.0
Min. outer
diam.
mm
65.0
72.0
Approx. weight
(kg/km)
kg/km
9780
12620
Four cores
Cross
section
mm
1
1.5
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
Voltage drop,
single phase
V/A.km
34.08
23.3
23.3
14.0
8.71
5.84
3.42
2.2
1.44
1.04
0.75
0.56
0.44
0.36
0.31
0.28
0.23
Max. outer
diam.
mm
12.0
13.1
13.1
15.5
18.0
20.0
26.5
30.1
36.6
41.1
47.5
54.0
61.0
66.0
73.0
80.0
91.0
Min. outer
diam.
mm
9.6
10.2
10.2
12.5
14.0
15.7
20.8
23.8
28.9
32.5
37.7
42.7
48.4
53.0
58.0
64.0
72.0
Approx. weight
(kg/km)
kg/km
144
165
165
245
357
443
818
1150
1700
2180
3030
3990
5360
6500
7990
9910
13120
Five cores
Cross
section
mm
1
1.5
2.5
4
6
10
16
25
Voltage drop,
single phase
V/A.km
34.1
23.6
14.0
8.72
5.84
3.43
2.2
1.44
Max. outer
diam.
mm
14.0
14.4
17.0
19.9
22.2
29.1
33.3
40.4
Min. outer
diam.
mm
10.9
11.2
13.3
15.6
17.5
22.9
26.4
32.0
Approx. weight
(kg/km)
kg/km
180
238
297
453
557
1001
1430
2096
Seven cores
Cross section
mm
1.5
2.5
Page 5 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Voltage drop,
single phase
V/A.km
23.3
Max. outer
diam.
mm
22.14
Min. outer
diam.
mm
17.6
Approx. weight
(kg/km)
kg/km
510
702
Eighteen cores
Cross
Perm. current rating
section
open air
mm
A
1.5
9
2.5
Voltage drop,
single phase
V/A.km
20.7
Max. outer
diam.
mm
26.3
Min. outer
diam.
mm
20.7
Approx. weight
(kg/km)
kg/km
730
1018
Max. outer
diam.
mm
30.7
Max. outer
diam.
mm
35.2
Page 6 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans