Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

EXLIM Q-D - Section of Surge Arrester Buyers Guide - Edition 11 2014-05 - English - 1HSM 9543 12-00en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

High Voltage Surge Arresters

Buyers Guide Section EXLIM Q-D

Zinc Oxide Surge Arrester EXLIM Q-D

Protection of switchgear, transformers and other


equipment in high voltage systems against atmospheric
and switching overvoltages.
in areas with high lightning intensity and high energy
requirements.
where grounding or shielding conditions are poor or
incomplete.
Other data can be ordered on request. Please
contact your local sales representative.

Brief performance data


System voltages (Um)

170 - 420 kV

Rated voltages (Ur)

132 - 420 kV

Nominal discharge current (IEC)

10 kApeak

Classifying current (ANSI/IEEE)

10 kApeak

Discharge current withstand strength:


High current 4/10 s

100 kApeak

Low current 2000 s

1000 Apeak

Energy capability:
Line discharge class (IEC)

Class 3

[2 impulses, (IEC Cl. 8.5.5)

7.8 kJ/kV (Ur)]

Fulfils/exceeds requirements of ANSI transmissionline discharge test for 245 kV systems.


Short-circuit/Pressure relief capability

65 kAsym

External insulation

Fulfils/exceeds
standards

Mechanical strength:
Specified long-term load (SLL)

7200 Nm

Specified short-term load (SSL)

18 000 Nm

Service conditions:

100 Technical information | ABB Surge Arresters Buyers Guide

Ambient temperature

-50 C to +45 C

Design altitude

max. 1000 m

Frequency

15 - 62 Hz

EXLIM Q-D

Guaranteed protective data

Max.
system
voltage

Rated
voltage

Max. continuous
operating voltage

TOV capability

2)

Max. residual voltage with current wave

1)

as per
IEC

as per
ANSI/IEEE

30/60 s

8/20 s

Um

Ur

Uc

MCOV

1s

10 s

0.5 kA

1 kA

2 kA

5 kA

10 kA

20 kA

40 kA

kVrms

kVrms

kVrms

kVrms

kVrms

kVrms

kVpeak

kVpeak

kVpeak

kVpeak

kVpeak

kVpeak

kVpeak

170

132

106

106

153

145

254

262

272

295

311

342

382

144

108

115

167

158

277

286

297

322

339

373

417

162

108

131

187

178

312

321

334

362

381

419

469

168

108

131

194

184

323

333

346

376

395

435

486

180

144

144

208

198

346

357

371

402

423

466

521

192

154

154

222

211

369

381

396

429

452

497

555

198

156

160

229

217

381

393

408

443

466

512

573

210

156

170

243

231

404

417

433

469

494

543

608

216

156

175

250

237

415

428

445

483

508

559

625

219

156

177

254

240

421

434

451

489

515

567

634

228

156

180

264

250

438

452

470

510

536

590

660

216

173

175

250

237

415

428

445

483

508

559

625

228

182

182

264

250

438

452

470

510

536

590

660

240

191

191

278

264

461

476

495

536

564

621

694

258

191

209

299

283

496

512

532

576

607

667

746

264

191

212

306

290

507

523

544

590

621

683

764

258

206

209

299

283

496

512

532

576

607

667

746

264

211

212

306

290

507

523

544

590

621

683

764

276

211

221

320

303

530

547

569

617

649

714

798

288

230

230

334

316

553

571

593

643

677

745

833

330

264

267

382

363

634

654

680

737

776

854

954

336

267

272

389

369

646

666

692

751

790

869

972

360

267

291

417

396

692

714

742

804

846

931

1046

372

267

301

431

409

715

737

766

831

875

962

1080

378

267

306

438

415

726

749

779

844

889

978

1098

381

267

308

441

419

732

755

785

851

896

985

1106

390

267

315

452

429

749

773

803

871

917

1013

1132

396

267

318

459

435

761

785

816

885

931

1029

1150

420

267

335

487

462

807

833

865

938

987

1091

1219

245

300

362

420

1) The continuous operating voltages Uc (as per IEC) and MCOV (as per ANSI) differ only due to deviations in type test procedures.
Uc has to be considered only when the actual system voltage is higher than the tabulated.
Any arrester with Uc higher than or equal to the actual system voltage divided by 3 can be selected.
2) With prior duty equal to the maximum single-impulse energy stress (4.5 kJ/kV (Ur)).
Arresters with lower or higher rated voltages may be available on request for special applications.

ABB Surge Arresters Buyers Guide | Technical information 101

EXLIM Q-D

Technical data for housings

Max.
system
voltage

Rated
voltage

Um

Ur

kV rms

kVrms

170

132

DH170

144-168

245

300

362

420

Housing

Creepage External insulation *)


distance

Dimensions

1.2/50 s
dry

50 Hz
wet (60s)

60 Hz
wet (10s)

250/2500 s
wet

Mass

A max

mm

kVpeak

kVrms

kVrms

kVpeak

kg

mm

mm

mm

mm

4432

774

378

359

n.a.

155

1645

600

300

DH170

4432

774

378

359

n.a.

155

1645

132-144

DV170

6570

1172

556

546

924

230

2585

800

500

162-168

DV170

6570

1172

556

546

924

230

2585

600

300

180-219

DH245

6570

1172

556

546

924

230

2585

800

500

228

DH245

6570

1172

556

546

924

235

2585

600

300

180

DV245

7717

1360

656

632

1078

270

2915

1400

1000

700

192-198

DV245

7717

1360

656

632

1078

270

2915

1200

1000

600

210-228

DV245

7717

1360

656

632

1078

270

2915

800

500

228-264

DM300

6570

1172

556

546

924

240

2585

800

500

216

DH300

7717

1360

656

632

1078

275

2915

1400

1000

700

228-240

DH300

7717

1360

656

632

1078

280

2915

1200

1000

600

258-264

DH300

7717

1360

656

632

1078

275

2915

800

500

216

DV300

9855

1758

834

819

1386

350

3859

1600

1000

1200

228-240

DV300

9855

1758

834

819

1386

355

3859

1600

1000

1000

258-264

DV300

9855

1758

834

819

1386

355

3859

1200

1000

800

258-264

DM362

7717

1360

656

632

1078

280

2915

1400

1000

700

276-288

DM362

7717

1360

656

632

1078

285

2915

1200

1000

600

258-288

DH362

9855

1758

834

819

1386

360

3859

1600

1000

1000

258-288

DV362

12149

2134

1034

991

1694

415

4520

1800

1000

1000

330-360

DM420

8864

1548

756

718

1232

325

3245

1400

1000

700

330-360

DH420

11002

1946

934

905

1540

400

4190

1800

1000

1000

372-396

DH420

11002

1946

934

905

1540

400

4190

1400

1000

700

420

DH420

11002

1946

934

905

1540

400

4190

1200

1000

600

330-420

DV420

13296

2322

1134

1077

1848

465

4850

1800

1000

1000

* Sum of withstand voltages for empty units of arrester.


)

102 Technical information | ABB Surge Arresters Buyers Guide

Fig.

EXLIM Q-D

Technical data for housings

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

ABB Surge Arresters Buyers Guide | Technical information 103

EXLIM Q-D
Accessories

Line terminals

Earth terminals

Drilling plans

1HSA410 000-A
Aluminium

1HSA420 000-C
Stainless steel
Without insulating base
Aluminium

1HSA410 000-B
Aluminium flag with other
items in stainless steel
1HSA420 000-D
Stainless steel

1HSA410 000-C
Aluminium
Insulating base
1HSA430 000-C
Epoxy resin
M16 bolts for connection to structure
are not supplied by ABB. Required
threaded grip length is 15-20 mm.

1HSA410 000-D
Stainless steel

104 Technical information | ABB Surge Arresters Buyers Guide

EXLIM Q-D
Shipping data

Rated voltage

Housing

Number of arresters per crate


One

Three

Six

Ur

Volume

Gross

Volume

Gross

Volume

Gross

kVrms

m3

kg

m3

kg

m3

kg

132-168

DH170

0.5

195

1.7

365

1.7

530

132-168

DV170

1.4

275

2.8

545

2.8

790

180-228

DH245

1.4

280

2.8

555

2.8

805

180

DV245

2.4

375

4.2

685

4.1

960

192-198

DV245

2.2

360

3.8

670

3.9

950

210-228

DV245

1.7

315

3.1

615

3.1

890

228-264

DM300

1.4

290

2.8

575

2.8

835

216

DH300

2.4

380

4.2

695

4.1

975

228-240

DH300

2.2

365

3.8

680

3.9

965

258-264

DH300

1.7

320

3.1

630

3.1

910

216-240

DV300

2.9

500

5.7

930

6.1

1315

258-264

DV300

1.9

445

3.6

875

5.0

1240

258-264

DM362

2.4

385

4.2

705

4.1

995

276-288

DM362

2.2

375

3.8

690

3.9

985

258-288

DH362

2.9

505

5.7

940

6.1

1330

258-264

DV362

3.2

575

6.3

1075

6.7

1535

276-288

DV362

3.2

575

6.0

1060

6.7

1525

330-360

DM420

4.2

475

4.9

835

5.3

1175

330-360

DH420

3.2

545

6.0

1015

6.7

1430

372-396

DH420

2.4

505

5.6

970

5.5

1380

420

DH420

2.2

485

5.2

945

5.3

1370

330-360

DV420

3.2

615

6.6

1150

7.0

1450

Each crate contains a certain number of arrester units and


accessories for assembly and erection. A packing list is attached externally on each crate.
Each separate crate is numbered and the numbers of all
crates and their contents are listed in the shipping specifica-

tion. ABB reserves the right to pack arresters in the most


effective/economic combination. Alternate or non-standard
crates may involve additional charges.
The table above is to be seen as an approximation and
specific data for deliveries may differ from the values given.

ABB Surge Arresters Buyers Guide | Technical information 105

ABB AB
High Voltage Products
Surge Arresters
SE-771 80 Ludvika, Sweden
Phone: +46 (0)240 78 20 00
Fax: +46 (0)240 179 83
E-Mail: arresters.div@se.abb.com
www.abb.com/arrestersonline

Copyright 2014 ABB


All rights reserved
NOTE: ABB AB works continuously with product
improvements. We therefore reserve the right to
change designs, dimensions and data without prior
notice.

Section of 1HSM 9543 12-00en High Voltage Surge Arresters Buyers Guide, Edition 11, 2014-05

For more information please contact:

You might also like