Hecs XXLP 1hc0067697ab en High

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Product Brochure

Generator Circuit-Breaker Systems HECS-100/130XLp HECS-130XXLp

Technical Data
Generator circuit-breaker system type General Rated maximum voltage Rated frequency Rated continuous current 50 Hz Rated continuous current 60 Hz Rated insulation level Rated power frequency withstand voltage to earth and across circuit-breaker/switch contacts across isolating distance of disconnector Rated lightning impulse withstand voltage to earth and across circuit-breaker/switch contacts across isolating distance of disconnector Circuit-breaker Rated peak withstand current Rated short-time withstand current Rated short-circuit making current Rated short-circuit breaking current Rated operating sequence Opening time Rated interrupting time Mechanical endurance life Disconnector Rated peak withstand current Rated short-time withstand current Operating time Earthing Switch Rated peak withstand current Rated short-time withstand current Operating time kA peak kA, 1s s 300 100 2 360 130 2 360 130 2 kA peak kA, 3s s 300 100 2 360 130 2 360 130 2 ms ms CO 34 5 68 20000 kA peak kA, 3s kA peak kA rms 300 100 300 100 360 130 360 130 CO - 30min - CO 34 5 68 20000 34 5 68 20000 360 130 360 130 kV peak kV peak 125 (150) 145 (165) 125 (150) 145 (165) 125 (150) 145 (165) kV rms kV rms 60 (80) 70 (88) 60 (80) 70 (88) 60(80) 70 (88) kV Hz A rms A rms 25.3 50/60 up to 18000 up to 17000 25.3 50/60 up to 18000 up to 17000 25.3 50/60 up to 23000 up to 21500 HECS-100XLp HECS-130XLp HECS-130XXLp

The above data are not limiting values. Additional data on request. We reserve the right to alter data and technical details without notice.

Equipment Options 1 2 3 4 5 6 7 8 9 Generator circuit-breaker Line disconnect switch Earthing switch Starting switch for SFC connection Manual short-circuiting connection
(by removal of cover)

4 8
G

5 8 1 2 7

Surge capacitor Current transformers Voltage transformers Surge arrester

2 | ABB

Dimension Drawing HECS-XLp

960

Transformer Side

3470 *)

1400-1500

Generator Side
1000 *) 1700 N(1400-1800) N(1400-1800) 640 400 *)

3740 + 2N *)

N = Phase distance *) min. space required for erection and maintenance

3000 *) ABB | 3

2200

min. 2975

Dimension Drawing HECS-XXLp

960

Transformer Side

3470 *)

1400-1500

Generator Side
1000 *) 1700 N(1600-1800) N(1600-1800) 640 400 *)

3740 + 2N *)

N = Phase distance *) min. space required for erection and maintenance

4 | ABB

3000 *)

2200

min. 2975

Contact us

www.abb.com/gcb

Copyright ABB. 1HC0067697 E02 / AB09

ABB Switzerland Ltd High Voltage Products Brown Boveri Strasse 5 CH-8050 Zurich / Switzerland Phone: +41 58 588 34 24 Fax: +41 58 588 16 44