Powerware 9120

Uninterruptible Power System


700-6000 VA

Product Focus

Features
Series 9 double conversion online
Superior electrical performance
Extended backup time
User friendly, informative LCD display
ABM, prolongs battery service life by 50%
Software Suite bundled
Versatile customisation options

As business becomes increasingly

applications as well as security

The Powerware 9120 is

dependent on technology for their

solutions. Powerware 9120 with

supplied bundled with the

fundamental operation, the

its wide input voltage window

Powerware Software Suite that

need for system availability is of

is capable of working with

includes everything required

paramount importance.

mains power in most conditions

for trouble free operation.

The Powerware 9120 UPS is

without discharging batteries,

LanSafe included on the

designed for applications that

thus saving battery capacity for

software package monitors all

require maximum protection.

when it is really needed. The

network devices and provides

With its double conversion

exeptional electrical performance

an orderly shutdown in the

design, the 9120 provides

of the 9120 ensures that these

event of extended power

uninterruptible clean sine wave

UPS can be used in almost any

outage. The 9120 also caters

power to the critical loads and

application. In addition, the wide

for advanced users who may

with its advanced communication,

range of options such as external

require an additional interface

the 9120 is the ideal solution for

battery cabinets, and transformer

to work with a slot for COM

networks, web servers as well as

cabinets enable customisation for

options like SNMP/WEB card and

industrial application protection.

a wide range of applications.

an AS/400 card. These options

The Powerware 9120 has been

The unique Advanced Battery

give the opportunity to build up

developed for critical computer

Management (ABM) function

a management system that well

and communication equipment,

prolongs the service life of

integrates to other management

where losses may accumulate

batteries by 50%. And when

systems in a company.

at frightening speed in case of

ABM informs the user that the

power failure.

batteries should be changed

In industrial environments the

this can easily be done without

9120 will protect small industrial

running down the load (hot

control and automation

swappable batteries).

Advanced features that give you business benefits


Advanced Battery
Management

Hot swappable batteries

battery capacity for the load

All the Powerware 9120 models

segment where the most critical

UPS systems traditionally have

(700-6000VA) have been

equipment is connected.

maintenance free lead-acid

developed with hot-swappable

battery solution that is both

batteries, therefore internal

critical and expensive for the

batteries can be changed without

Dual input on 6000VA


models

user. The expected lifetime of

powering down the load.

Powerware 9120 6000VA


models can be installed using

batteries is shorter compared to


the rest of the UPS. Therefore,

Extended runtimes

a separate input cable for the

one should pay attention to the

Each the Powerware 9120 model

internal bypass. This feature not

right battery solution. Today

can be equipped with External

only provides redundancy for the

virtually all competitive UPS

Battery Cabinets, this can extend

input, but it also enables system

products use traditional float

the runtimes to hours.

with two UPSs to increase power


availability. The critical load is

charging technology. The unique

powered by the first UPS and

provides additional benefits by

Load Segments on 7003000VA models

providing a three-stage charging

Load Segments are groups of

is transferred to the bypass

technique that constantly

outlets that can be independently

source which is supplied by

monitors the battery charging

controlled. To preserve

another UPS. This configuration

status, and as a result only

battery power for more critical

enables redundant operation with

recharges when necessary, so

equipment connected to the UPS

standard UPS units.

ultimately the battery experiences

it is possible to shut down one

less corrosion and battery service

load segment that supports less

External Bypass options

life is prolonged by up to 50%.

critical load and thereby preserve

All Powerware 9120 units can be

Powerware ABM technology

in the case of a failure the load

installed with an External Bypass


option which enables swap or
service without powering down
the critical load.

Internal
batteries

With 1 EBM

With 2 EBM

350VA/245W

20

90

160

Informative user interface with

700VA/490W

35

65

LCD, and four LED and audible

Load
9120 700VA

User interface

alarms.

9120 1000VA
500VA/350W

21

85

160

This enables easy configuration

1000VA/700W

37

68

of your UPS by changing UPS

500VA/350

28

115

220

1000VA/700W

14

55

100

1500VA/1050W

33

60

500VA/350W

65

>240

>420

1000VA/700W

30

125

220

1500VA/1050

19

70

140

9120 1500VA

9120 2000-3000VA

2000VA/1400W

14

55

100

2500VA/1750W

10

45

80

3000VA/2100W

30

65

1000VA/700W

80

>300

>480

2000VA/1400W

38

145

300

3000VA/2100W

23

90

150

4000VA/2800W

15

65

120

5000VA/3500W

10

45

85

6000VA/4200W

35

65

9120 6000VA

settings using the LCD panel.

Building solutions to manage and monitor your UPS


USB and RS 232 ports as
standard.
The standard serial connection

ConnectUPS Web/SNMP
card for connectivity slot
(option)

has two interfaces; RS 232 and

is a complete UPS monitoring,

Environmental Monitoring
Probe for ConnectUPS
Web/SNMP adapters
(option)

USB. In addition Powerware

control and shutdown solution

The Environmental Monitoring

9120 is equipped with a

in a networked IT environment.

Probe adds temperature,

connectivity slot that works in

In case of alert the Web/SNMP

humidity and two contact

parallel to either RS232 or USB

card can notify users and

closure monitoring capability to

port.

administrators through email

ConnectUPS Web/SNMP card.

and SNMP traps. In case of a

It is especially well suited for

EPO as standard

prolonged power failure the

monitoring rack temperature and

All Powerware 9120 comes

protected computer systems

door status. Operating system

equipped with an EPO port

can be shut down in a graceful

shutdown can be triggered if

enabling shutdown of the

manner with NetWatch and

user defined thresholds are

connected equipment from a

LanSafe software.

exceeded or contact closure


status changes.

remote location in an emergency.


After the EPO port has been
activated the unit has to be

Relay/AS400 card
(option)

started manually by pushing the

provide an easy connection to

Remote Control panel,


ViewUPS (option)

ON button.

IBM AS/400 series computers

LCD display that allows

as well as industrial and building

monitoring the UPS within 50 m

management systems. You can

radius of the unit.

also build a solution for a remote


ON/OFF function with the relay
card.

Software suite

whole network across platforms

Monitoring software

Powerware offers a full line

in case of a prolonged power

PowerVision is performance

of shutdown and monitoring

failure. LanSafe allows the

monitoring and trend analysis

software products to enhance

shutdown of up to 64 computers

software for critical UPSs and

the protection provided by its

protected by a single UPS.

multiple UPSs in a network. It

UPSs. The software suite,

calculates trends and stores

conveniently packed on one CD-

NetWatch is a shutdown agent

information about the operation

ROM, follows every UPS free of

for the ConnectUPS Web/SNMP

of the UPS device in its

charge.

card. It is a very compact piece

database. PowerVisions alert

of software, but still features

and notification behaviour is

Shutdown software

powerful configuration options

highly configurable, which

LanSafe is a network shutdown

for shutdown actions, timings

makes it a great tool for system

software product that currently

and user notification. NetWatch

administrators. Optional

supports up to 20 operating

is available for Windows, Novell,

shutdown controller module can

systems. It ensures controlled

MacOS X, and most Unix

host hudreds of shutdown clients

sequential shutdown of the

platforms including Linux.

and it can also be used in case of


paralleled UPSs.

Technical Specifications
Powerware 9120 specifications table
Rating

700VA

1000VA

1500VA

2000VA

3000VA

6000VA

Part number

91200700A

91201000A

91201500A

91202000A

91203000A

91206000A

Capacity (VA/Watts)

700/490

1000/700

1500/1050

2000/1400

3000/2100

6000/4200

Dimensions WxDxH(mm)

155x410x240

155x410x240

170x445x275

225x470x365

225x470x365

280x580x570

Weight (kg)

13

15

20

37

38

91

Input connection

IEC320/10A

IEC320/10A

IEC320/10A

IEC320/10A

IEC320/16A

Hardwired

Output connection

4xAUST10A

4xAUST10A

4xAUST10A

5xAUST10A

5xAUST15A

Hardwired

Operational
Nominal input voltage (Vac)

208/220/230/240 Vac

Input voltage range

120/140/160-276 Vac (700-3000VA at 33%/66%/100% load)


120/140/160/184-276 Vac (6000VA at 25%/50%/75%/100% load)

Operating frequency

50/60 Hz auto sensing (+/-3 Hz, adjustable)

Input power factor

0,97 (700-3000VA)
0,99 (6000VA)

Nominal output voltage

208/220/230/240 Vac

Output voltage regulation

+/-2% online; +/-3% on battery mode

Overload capacity

Up to 125 % for 1 minute, 125-150% for 10 sec

Efficiency

> 86% (700VA); > 88% 1000-3000VA ; > 90% 6000VA (Online mode)
> 90% (700VA); > 93% 1000-3000VA ; > 95% 6000VA (High efficiency mode)

User interface
LCD display

LCD display showing both UPS meters and UPS settings

LED

Four LEDs; UPS On, UPS on Battery, UPS on bypass, Alarm

Standard communication
ports

RS232 and USB as standard on all models

Optional

Connectivity slot for SNMP/WEB card and relay card

Environmental
Operating temperature

0C +40C

Storage temperature

-15C +40C

Altitude

< 3000 m

Audible noise at 1 metre

< 45 dB (700-1500VA), < 50 dB (2000-3000VA). < 55 dB (6000VA)

Certification
Markings

C-Tick CE/GS/UL (700-2000VA), C-Tick CE/GS (3000VA-6000VA)

Safety

EN 50091-1-1 & UL 1778 (700-2000VA, EN50091-1-1 (3000-6000VA)

EMC

EN 50091-2, EN6100-3-2 (700-3000VA), EN50091-2 (6000VA), C-Tick

Battery Runtimes (in minutes full load/half load)*


Model/Load

Standard interna
Batteries

+1 EBM

+2 EBMs

+3 EBMs

700VA/490W

6/20

46/96

80/168

1000VA/700W

8/21

36/75

62/126

1500VA/1050W

7/20

32/67

54/112

78/157

2000VA/1400W

14/30

50/100

85/169

118/236

3000VA/2100W

8/20

30/65

50/110

75/155

6000VA/4200W

8/23

35/90

65/150

* EBM runtimes include internal batteries. Run time chart provides typical information. Battery runtimes are approximate and may vary with
equipment, configuration, battery age, temperature, etc.. More EBM options are available on request.
In the interests of continual product improvement all specifications are subject to change without notice.
Eaton, Powerware, Hot Sync, Advanced Battery Management, LanSafe, PowerVision, and FORESEER are trade names, trademarks, and/or service marks of
Eaton Corporation or its subsidiaries and affiliates. 2007 Eaton Corporation, All Rights Reserved.

Head Office
Eaton Power Quality Pty Ltd
10 Kent Road
Mascot NSW 2020
Phone: +61 2 9693 9366
Fax: +61 2 8338 1159
www.powerware.com.au

Sales 1300 UPS UPS


Service 1300 303 059

SALES OFFICES
Queensland
Phone: +61 7 3844 9728
Fax: +61 7 3217 2199

Western Australia
Phone: +61 8 9446 0520
Fax: + 61 8 9244 7466

Victoria
Phone: + 61 3 9706 5662
Fax: + 61 3 9794 9150

Auckland New Zealand


Phone: + 64 9 273 3970
Fax: +64 9 273 3980

SOUTH AUSTRALIA
Phone: +61 8 8347 3622
Fax: +61 8 8445 6328

WELLINGTON New Zealand


Phone: + 64 4 477 4717
Fax: +64 4 477 3691
9120 Broch Rev2 07/2007

You might also like