GB Masterys BC 8 12 Catalogue 2012
GB Masterys BC 8 12 Catalogue 2012
GB Masterys BC 8 12 Catalogue 2012
Single-phase and
three-phase UPS
from 8 to 12 kVA
for critical IT and light industrial applications
The solution for
> Light industrial applications
> Servers
> Telecommunications
> Medical and laboratories
MASTE 049 B
Certifications
Complementary pages
> Communication and
Easy to install.
Unique to the market with its highly compact
size.
Flexible back-up times: different back-up
time configurations are available either within
the UPS standard cabinet or by using taller
UPS cabinets, without changing the floor
space (W = 444, D = 795 mm).
Increased system availability placing two
UPS in parallel.
Combi Concept: BC108 and BC110 models
are compatible with single or three-phase
inputs, which can be configured during
installation.
Fitted with a multilanguage LCD display.
Separate rectifier supply and bypass
networks.
An excellent size/power/back-up
time ratio
Ideal for sensitive professional applications.
Suitable for protection in IT environments
thanks to the internal back-up time and the
possibility of installation in 19 rack cabinets.
32
MASTERYS BC
from 8 to 12 kVA
Single-phase and three-phase UPS
Technical data
Voltage tolerance
Rated frequency
Frequency tolerance
Overload
Crest factor
Power factor without derating
BYPASS
Voltage tolerance
Frequency tolerance
EFFICIENCY
Online mode
Eco Mode
ENVIRONMENT
Operating ambient temperature
Relative humidity
Maximum altitude
Acoustic level at 1 m (ISO 3746)
UPS CABINET
Dimensions type S (short) W x D x H
Dimensions type M (medium) W x D x H
Dimensions type T (tall) W x D x H
Weight with standard batteries
Degree of protection
Colours
STANDARDS
Safety
EMC
Performance
Product declaration
8
5.6
(1)
(1)
-
MASTERYS BC 8-12
10
7
(1)
(1)
up to 2 units
230 V (1ph +N), 400 V (3ph +N)
20% (up to -35% at 70% nominal load)
50/60Hz 10%
0.99/<6%(2)
155 kg
12
8.4
UPS
IN/OUT
kVA
10 20
30 40
50 60
70 80
90 100
MASTE 061 A
Sn [kVA]
Pn [kW]
Input/output 1/1
Input/output 3/1
Input/output 3/3
Parallel configuration
INPUT
Rated voltage
Voltage tolerance
Rated frequency
Power factor / THDI
OUTPUT
Rated voltage
10
BC 112
3/1
12
BC 310
3/3
10
BC 312
3/3
12
Cabinet type S
Cabinet type M
Cabinet type T
Electrical options
Dual input mains.
Internal maintanance bypass.
External maintanance bypass.
E
xternal battery cabinet.
G
alvanic isolation transformer.
P
arallel kit.
Standard communication
features
MODBUS/JBUS RTU.
2 slots for communication options.
Communication options
175 kg
Dry-contact interface.
Remote mimic panel.
MODBUS TCP.
P
rofibus.
N
ET VISION: professional WEB/SNMP
interface for UPS monitoring and shutdown
management of several operating systems.
(1) Combi: single or three-phase input configurations. - (2) 1/1 configuration, THDI <25% for 3/1 configuration.
(3) @ Pout =90% Pnom.
33