CSB 188 Manual
CSB 188 Manual
CSB 188 Manual
PAGE1
OPERATIONANDMAINTENANCEMANUAL
REFRIGERATEDTYPEHYDROGEN
GASDRYER
CSB188
CLIENT
M/SBHEL,HARIDWAR
Manufacturer:
M/s.MELLCONENGINEERSPVT.LTD
B297,OKHLAINDUSTRIALAREA
PHASEI,NEWDELHI:110020.
PH.01126816103,26816530,
26811727
FAX.01126816573
EMail:
mellcon@mellcon.com
Website:
www.mellcon.com
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE2
CLIENT
M/sBHEL,HARIDWAR
EQUIPMENT
REFRIGERATEDTYPEHYDROGENGASDRYER
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE3
CONTENTS
01.INTRODUCTION
02.TECHNICALSPECIFICATIONS
03.PROCESS
04.TESTPROCEDURE
05.SEQUENCEOFOPERATION
06.SAFETYCHECKUP
07.SAFETYDEVICES
08.PLANTSTARTUP
09.TROUBLESHOOTINGCHART
10.GENERALMAINTENANCE
11.TECHNICALINFORMATIONTOREFRIGERATIONENGINEER
12.WARRANTY
13.RECOMMENDEDLISTOFSPAREPARTS
14.SUGGESTEDLOGSHEET
15.DRAWINGS:
(i)P&IDiagram
:CSB188PI
(ii)ControlPanelWiringDiagram
:CSB188CP
16.WARRANTYPOLICY
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE4
INTRODUCTION
These instructions broadly covers the technical data, process flow description and
procedure to befollowedduringstartup,normaloperation,maintenanceandemergency
stopfortherefrigeratedtypehydrogengasdryer.
All information and drawing given with this manualis strictlyconfidentialand are tobe
usedonly forthe purposeofoperationandmaintenanceof thissystem. Theinformation
provided withthismanualisthepropertyofMellconEngineersPvtLtd.Delhiandshould
notbepublicandcopied.
TECHNICALSPECIFICATION
01. DryerCapacity
:40M3/HR
02. InletPressure
:5KG/cm2(g)
03. InletTemperature(Max.)
:60Deg.C.
:Nil
:415VAC,3phase,50Hz.
07. Operation
:Automatic
08. Baseframesize
:900mmX850mm
09. Heightfrombase
:2000mm(Approx)
10. Refrigerant
:R134a
(FordetailsreferElectricalDrg.)
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE5
PROCESS
Hydrogen gas saturated with water vapour, enters dryer inlet and is precooled by
outgoing refrigerantineconomiser(precooler),asmoothsurface,nonfoulinggastogas
heat exchanger. Pre cooling removes some of the heat load from the incoming gas
allowing the use of a more efficient refrigeration condensing section. The precooled
gas then passes through a smooth surface, Nonfouling air to refrigerant heat
exchangerChiller(refrigerantevaporator),whereitiscooledto+35degreecentigrade
by giving up heat to refrigeration system. Now the hydrogen gas passes through the
moisture separator, where thewaterisseparatedfromthegasanddischargedregularly
through the auto drain valve. The cold gas then exits at outlet, after it has passed
through the other side ofgas togasheatexchanger,(economiser) whereitis warmed
bythe incoming hot gas.Thisreheatingincreases the gas effectivevolume (enablingit
to do more work ) and prevents pipe sweating downstream. (The dried gas travels
through the activated carbon filter to yours plant ), gas stream does not fallbelowthe
temp. to which itwaschilledinthegastorefrigerantheatexchanger(referredtoasdew
point temp.) and hence no more water vapour will condense into troublesome liquid.
Removing the water allowsyoutokeeppipelines,gastools,valvesandcylinders,spray
guns,pneumaticinstrumentsandanygasoperateddevicecleananddry.
NOTE:
Togetbetterairquality,runtheairdryeratNOLOAdtoachievethedewpoint
of5Deg.C.,thengiveloadtothedryer(Ifchilleristanktype).
TESTPROCEDURE
As per our requirement testing ofequipment we usecompressor for air. For testing its
capacity40 m3/Hr at 60 degreecentigradeitisgoestoheaterof..KWforheatingofair
upto 4060 degreecentigradeand tempwitness through temp indicatorcontrollerafter
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE6
that air goes directly to precooler and from precooler to chiller from where air chilled
through freoncircuit upto35degreecentigrade onthistempairmoisturecondensed
andcomeintothemoistureseparatorfromwhereitisdrained
automatically and manually both after that air comes from moisture separator to
precooler where air heat is removed from precooler and take it to process. Complete
freon circuit functions automatically. Theparametersaretobecheckedasunderasper
yourrequirements.
SEQUENCEOFOPERATION
There are two type of starting of control circuit. Oneis remote ON/OFF and secondis
local ON/OFF which is operated by selector switch SW1. BYselecting selector switch
sw 1 on remote mode , control relay CR 3 will be activated only on the command of
GAMP. As per the command of GAMP CR3 will be energize, which will ON thedryer
and lamp indication L5will glowup, which confirm that the dryeris ON.similarlywhen
GAMP signalis notavailable, ControlrelayCR3willdeenergize andselectorswitchat
localmode then it will activated dryerONthrough NC contactof control relayCR3.the
lampindicationL5willglowupandconfirmthatdryerisON.
1. DTC1,DTC2,DTI1&DTI2willbeactive.
CompressorOn/OFFtakesplaceByDTCasperthesettemperature.
DTI1show the dryerinlet temperature ofgas throughsensorwhichismounted
atdryerinlet.
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE7
In manual mode For manual mode operation, we kept the selector switch
SW2 at manual mode which energizethe control relayCR1and throughcontrol
relay CR1 NO contact which becomes NC now, switch ON thecompressor and
also activate thesolenoidvalveSVandlampindicationL8glowup whichconfirm
thatcompressorisON.
In auto mode For auto mode operation , we kept selector switch on auto
mode. which energizethe cyclic timerCT.andthroughNOcontactofCT,control
relay CR2 will energize and switch ON the compressor. the lamp indication L8
willglowupwhichconfirmthatcompressorisON.
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE8
SAFETYCHECKUP
DisconnectPowersupplytounitbeforeperforminganyelectricalservicework.
Before working on hydrogen gas side of unit isolate dryer from hydrogen gas
supply by shutting off inlet valves and opening bypass valve (if provided) and
depressuriseunitbyopeningspetcockoncondensatedraintrap.
Donotexceedmaximumhydrogengaspressureratingspecified.
Thedryershouldnotbekeptunderdirectsunlight.
Donotexceedmaximuminletgastempspecified.
SAFETYDEVICES
SPPRTRIP:
OVERLOADRELAY:
OR
CAUTION
:
DonotchangethecurrentsettinginOverLoadRelay.
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE9
TEMPERATUREINDICATINGCONTROLLER:
The Temperature Indicating Controller (TIC or DTC) is meant for controlling the Dew
Point temperature. A resistance thermal device type sensor is used for accurate
temperaturecontrolling.
DIGITALTEMPERATUREINDICATOR:
HP/LPSWITCH:
IMPORTANT:
Donotchangesettings.
PRESSURESWITCH:
IMPORTANT
:
Donotchangesettings.
PLANTSTARTUP
INSTALLATION
ConnecttheHydrogenGasinlet&outlet..
Connect the Electrical connection to the Dryer. Refer attached Control Panel
WiringDiagramfordetails.
MOUNTING
No special foundation is required. However, care should be taken to ensure that the
unitisplacedonlevelsurface.
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE10
PIPING
Hydrogen
gas inletand outlet :Connect hydrogen gaslinesto gas inlet and gasoutlet
locatedandidentifiedonthesideofthecabinet.Pipingandarrangementswouldinclude
inletandoutletvalvesandalsoasuitableairbypassifdesired.
ELECTRICALHOOKUP
IMPORTANT
:Thedryerisdesignedtoruncontinuouslyandmustnotbewiredtocycle
ON and OFF with the air compressor. Dryer compressor can be turn off during
shutdownperiodsbyusingON/OFFswitchonfrontpanel.
NOTE:
IMPORTANT:
DONOTturnoffpowertounitexceptwhenservicing.
TROUBLESHOOTINGCHART
S.NO NatureofFault
PossibleReason
1.
HPTrip
Condenserchoked
ActionTaken
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE11
Setting
may
beendisturbed.
Gasovercharged
Ifthem/cisoverload
Noneoftheabove
Contactthemanufacturer.
2.
LPTrip
closed.
Gasleakedout.
noload.
Noneoftheabove.
contactthemanufacturer.
3.
OLRTrip
Looseconnection
Setting
may
beendisturbed.
Singlephasing.
Checkallthreephases.
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE12
If the equipment
runningonoverload.
Noneoftheabove.
contactthemanufacturer.
4.
SPPRTrip
Looseconnection
Noneoftheabove.
is Checktheload.
contactthemanufacturer.
GENERALMAINTENANCE
2. On air cooled models, blowing out and cleaning of dirt and dust from the air
cooled refrigeration condensing unit and especially the refrigeration condenser
monthly or as required depending on condition of the area in which dryer is
installed. in exceptionally dirty location, a furnace type filter installation front of
the refrigeration condenser is recommended.It shouldbe keptclean in orderto
maintainfreeairflowacrosscondenser.
3. Do not Tamper with refrigeration section. Settings made at the factory are for
normal conditions. Where conditions are unusual, consult manufacturer's to do
needful.
TECHNICALINFORMATIONTOREFRIGERATIONENGINEERS
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE13
IMPORTANT:
Wirebrushesorhighpressureair/waterjetsshouldnotbeused.
REFRIGERANTLEAKAGERECTIFICATION: Ifanygasleakageisthereinthe
system proper cooling can not be achieved and suction pressure will showthe
lesser than required. If excess gas is leaked out then lp switch will trip the
system. to rectify the leakage ofthe systemconsult withaqualified refrigeration
engineer.
COMPRESSORREPLACEMENT :
Duringcompressor replacement thedryerto
bereplaced andthe wholerefrigerantpipestobeflushed.Thenvacuumandgas
charging is to be done. Therefore it is recommended toconsult withaqualified
refrigerationengineer.
WARRANTY(PLEASEALSOREFERWARRANTYPOLICY)
RECOMMENDEDSPAREPARTS
FreonDryer
Digitaltemperaturecontroller
Mcontactorforrefrigerationcompressor
HP/LPSwitch
:1NO.
:1NO.
:1NO.
:1NO.
MellconEngineersPvtLtd.
RfdtypeHydrogendryerOperatingManual
PAGE14
PressureSwitch
Delaytimer
DrainValve
FreonIndicator
SolenoidValve
CyclicTimer
:1NO.
:1NO.
:1NO.
:1NO.
:1NO.
:1NO.
NOTE
:
At the time of commissioning/ servicing of refrigerated typeair dryer, Please note that
the freongas vacuumpumpand tool &tackle shouldbe arranged by customer onfree
ofcostbasisforourtechnician.
LOGBOOKS
MellconEngineersPvtLtd.
Remarks :
Air Pressure
(Kg/Cm2 g)
Inlet
Outlet
Air Temperature
(Deg. C.)
Inlet
Outlet
Drain
Valve
(Auto/Manual)
Comp.
Current
(AMPS)
Freon
Pressure
Suct.
Disch.
ME/ISO/08/SV/06
Rev. : 1
Effective : 17/07/2013
Freon Temp.
Suction
TIC-2
Dew Point
Temp. TIC-1
Set.
Actual