Comparative Study For The Design of Single Span Bridge Using AASHTO LRFD and Indian Standard Method
Comparative Study For The Design of Single Span Bridge Using AASHTO LRFD and Indian Standard Method
ABSTRACT : This report summarizes the comparative design of a single-span Bridge using AASHTO LRFD
Bridge Design Specification, Indian standard T beam girder Bridge specification and Deck slab (excluding
girders). The writers address the differences in design philosophy, calculation procedures, and the resulting
design. Foundation design and related geotechnical considerations are not considered. The single span bridge
is studied for 10m The significant differences were:- 1)Increased shear Force in IS Method; 2) Increased
amount of Concrete in the deck Portion in IS Method; and 3)Large amount of Reinforcement was calculated in
case of IS Method. For the design of more than 25m span above results were reversed.The design using LRFD
Method is far safer than IS method (with/without Girder) because of special provision for parapet wall along
the bridge. Design procedures under the LRFD Specification tend to be more calculation-intensive. However,
the added complexity of the LRFD Specification is counterbalanced by the consistency of the design philosophy
and its ability to consider a variety of bridges.
Keywords -AASTHO, Bridges, Girder, Load and resistance factor design, IS Method, Spans.
I. INTRODUCTION
The ASSHTO-LRFD Specification uses the word extreme to describe two different items. Article
3.4.1 refers to Extreme Events, i.e., extreme loading events (AASHTO 1998). The Specification requires
checking the deck for vehicular collision with railing system at extreme event limit state. This signifies that, at
this level of loading, damage to structural component is allowed and the goal is to prevent the collapse of any
structural component. It does not necessarily imply that the placement of the vehicle on the curb or sidewalk is
an extreme loading event per Article 3.4.1 (AASHTO 1998).Thus it is engineers judgment to decide whether the
placement of the load on the curb or sidewalk should be included in Extreme Event II (Article 3.4.1) or whether
it should be included in the service and strength limit states (e.g., Service I, Service III, or Strength I). Inclusion
in Extreme Event II is appropriate if the recurrence interval associated with the event is thought to exceed the
design life [2] (Article C3.4.1; AASHTO 1998). Strength I is appropriate if the load event occurs more
frequently; i.e., it has a recurrence interval less than the service life of the structure. The LRFD approach is
reasonable for railings and sidewalks that are installed after the deck is in place and can distribute loads from the
exterior to the interior girders. Although permitted, this approach may not be reasonable for the diaphragms and
the deck itself. Before the deck concrete is set, the concrete is in the plastic state and it cannot distribute these
loads to the interior girders. Therefore these loads were not distributed between the interior and exterior girders
in the LRFD design of the example bridge. The maximum positive moment typically takes place at
approximately the center of each bay. The maximum bending moment varies depending on overhang length and
the value of distribution of dead load[1].The Indian Standard code prescribe that the Deck slab should be
designed for the worst case of either one of the L.R.C. Class AA tracked vehicle, one lane of Class AA wheeled
vehicle or two lanes Class A load train. It is necessary to compute Live Load Bending Moment for all three
cases and take greatest of them. Class AA wheeled vehicle for span less than 4m and Class AA tracked vehicle
for span exceeding 4m. If shear is desired to be computed; Class AA wheeled vehicle is to be considered for
span up to 6m and tracked vehicle beyond 6m. for single lane bridge. [3]the paper summarizes the changes in
design procedure by LRFD Method and compares the results with Design using Indian Standard (with and
Dead Load(Deck)
5.24(KN/m2)
21(KN/m2)
IS Method(With Girder)
5.5(KN/m2)
1.76(KN/m2)
61.35(KN/m2)
68.61(KN/m2)
VIII. CONCLUSION
Method
Solid Deck
Slab
T - Girder
LRFD
Reinforcement (Kg)
Deck
Girder
5095.31
N/A
Concrete (Cum)
Deck
75
Girder
N/A
3220.02
3555.4
20.86
19.91
16.48
-
3392.6
-
Wearing
Course (mm)
81.75
81.75
81.75
As It is clearly visible from above comparison that LRFD Design Specification has found to be most
economical of the two methods, Results shows reverse nature in case of larger span but LRFD is more safer
even for larger span. Indian Standard code suggest that the bridges more than 8m span should be designed with
Girders and it was found that for bridge span of 10m is safe in all checks even without Girders so It is needed to
be revise the Indian standard code with one standard Design for all span bridge. For Bridges with larger span
Author suggest that incorporation of bridge design in India also because it has a higher safety factor, more safety
norms. The resulting procedure is significantly more complicated. In general, more load cases are considered,
and in specific design equations more parameters are included. As a result, many of the design calculations can
no longer be readily performed by hand; for these calculations, computer methods are preferred. With the help
of software tools, LRFD design
of this type of bridge is not excessively tedious
Here Author has carried out Comparison for only RCC bridges which may further be extended up to Steel
bridges and pre stressed bridges.
REFERENCES
[1] Richard J. Nielsen, M.ASCE, and Edwin R. Schmeckpeper, M.ASCE, Single-Span Prestressed Girder Bridge: LRFD Design
and Comparison, journal of bridge engineering / January / February 2002
[2](AASHTO). (1996). AASHTO standard specification for highway bridges, 16th Ed., Washington, D.C.
[3 ] Indian Standard: 456-2000PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE, Bureau of Indian Standards, New Delhi
[4](AASHTO). (1994a). Guide specification for distribution of loads for highway bridges, Washington, D.C.
[5](AASHTO). (1998). AASHTO LRFD bridge design specification, 2nd Ed., Washington, D.C.
[6]Barker, R. M., and Puckett, J. A. (1997). Design of highway bridges based on AASHTO LRFD bridge design specifications, Wiley,
NewYork.
[7]D.J. Victor,Essentials of Bridge Engineering (Oxford and IBH, J.P. House New Delhi, 2007).
[8]IRC: 5, 6, 21, 24, 40-1998 Standard specification and code for practice for road Bridges, Indian Road Congress, 1998.