Slump Test Procedure and Sheet
Slump Test Procedure and Sheet
Standard Test
Procedures Manual
1.
Section:
CONCRETE
Subject:
SLUMP
SCOPE
1.1.
Description of Test
This test method describes the procedure for determining the slump of fresh concrete
mixtures.
2.
Equipment Required
Slump cone - a mold of 1.18 mm thick galvanized metal in the form of the lateral surface
of the frustum of a cone with the base 200 mm in diameter, the top 100 mm in diameter
and the height 300 mm. The base and the top shall be open and parallel to each other and
at right angles to the axis of the cone. The mold shall be provided with a foot piece on
each side for holding the mold in place, and with handles for lifting the mold from the
sample.
Tamping Rod - a round, straight steel rod 16 mm in diameter and approximately 600 mm
in length. The tamping end shall be a hemisphere 16 mm in diameter.
3.
PROCEDURE
3.1.
Sample Preparation
The sample of concrete from which test specimens are made must be representative of
the entire batch. It shall be obtained in accordance with STP 106.
3.2.
Test Procedure
Dampen the mold and place it on a flat, moist, non-absorbent rigid surface.
Hold firmly in place by standing on the two foot pieces.
Fill the cone 1/3 full and uniformly rod the layer 25 times to its full depth.
Fill the cone with a second layer until 2/3 full by volume and rod 25 times uniformly,
ensuring that the rod just penetrates into the first layer.
Date: 1993 12 09
Page 1 of 2
STP 207-3
Subject:
CONCRETE
SLUMP
Overfill the cone with the third layer and rod uniformly, 25 times, with the rod just
penetrating into the second layer.
Strike off the excess concrete level with the top of the cone by a screening and rolling
motion of the tamping rod.
Remove any spilled concrete from around the bottom of the cone.
Immediately remove the mold from the concrete by raising it carefully in a vertical
direction without lateral or torsional motion.
Measure the difference between the height of the mold and the height of the specimen at
its highest point to the nearest 6.3 mm. This distance will be the slump of the concrete.
4.
Reporting Results
The slump in mm will be reported.
5.
ADDED INFORMATION
5.1.
References
ASTM Method C143
CAN3-A23.2-M77
5.2.
General
When practicable, duplicate slump tests should be made and the average of the two
slumps reported.
The concrete temperature at time of testing should also be reported.
The entire operation from the start of the filling to the removal of the mold should be
carried out without interruption and be completed within an elapsed time of 1.5 minutes.
Run at least one test for every two truck loads.
Page: 2 of 2
Date: 1993 12 09
STP 207-3
Subject:
CONCRETE
SLUMP
APPROVAL SHEET
New
Revision X
Effective Date: - -
Comments/Concerns/Implications (Budget/Environment/Stakeholders):
93-12-09
Date
- -
Date
- Date
- Date
Date: 1993 12 09
- - -
Page: 3 of 2