Characteristics
Monitoring of three-phase mains for phase sequence and Approvals / Marks
failure A C R K E/a b
Powered by the measuring circuit
Closed-circuit principle Classifcations:
Screw connection technology or
EN 50155, IEC 60571, NF F 16-101/102, EN 45545-2
Easy Connect Technology available
Housing material for highest fire protection classification
EN 50155, IEC 60571
UL 94 V-0
Temp. Voltage supply Vibration and shock Coated pcb.
Tool-free mounting on DIN rail as well as demounting class S1 S2 C1 C2 acc to IEC/EN 61373
2 c/o (SPDT) contacts T3 n n *) *) Cat 1, Class B no
22.5 mm (0.89 in) width *) only applicable for devices with DC supply
Accessories
Type Description Order code
ADP.01 Adapter for screw mounting 1SVR430029R0100
MAR.01 Marker label 1SVR366017R0100
COV.11 Sealable transparent cover 1SVR730005R0100
Connection technology
Maintenance free Easy Connect Technology with Approved screw connection technology with
push-in terminals double-chamber cage connection terminals
Type designation CM-xxS.yyP Type designation CM-xxS.yyS
2CDC 253 026 F0011
Tool-free connection of rigid and flexible wires with Terminal spaces for different wire sizes:
wire end ferrule according to DIN 46228-1-A, finestrand with/without wire end ferrule:
DIN 46228-4-E 1 x 0.5-2.5 mm (2 x 20 - 14 AWG),
Wire size: 2 x 0.5-1.5 mm, (2 x 20 - 16 AWG) 2 x 0.5-1.5 mm (2 x 20 - 16 AWG)
Easy connection of flexible wires without wire end rigid:
ferrule by opening the terminals 1 x 0.5-4 mm (1 x 20 - 12 AWG),
No retightening necessary 2 x 0.5-2.5 mm (2 x 20 - 14 AWG)
One operation lever for opening both connection One screw for opening and closing of both cages
terminals Pozidrive screws for pan- or crosshead screwdrivers
For triggering the lever and disconnecting of wires according to DIN ISO 2380-1 Form A 0.8 x 4 mm
you can use the same tool (Screwdriver according to (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 4.5 mm
DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 (0.177 in)
in), DIN ISO 8764-1 PZ1 4.5 mm (0.177 in))
Constant spring force on terminal point independent
of the applied wire type, wire size or ambient
conditions (e. g. vibrations or temperature changes)
Opening for testing the electrical contacting
Gas-tight
Both the Easy Connect Technology with push-in terminals and screw connection technology with double-chamber cage
connection terminals have the same connection geometry as well as terminal position.
Operating controls
Application
The CM-PFS is used to monitor three-phase mains for incorrect phase sequence and phase failure.
Operating mode
The three-phase main to be monitored is connected to terminals L1, L2, L3 in accordance to the wiring diagram.
The device operates according to the closed-circuit principle g incorrect phase sequence or phase failure: relays de-
energize.
The signalling of status indication is made by means of the front-face LEDs.
Function diagram
L1, L2, L3
Measured value L1, L2, L3 L1, L3, L2 L1, L2, L3 L1, L2 L1, L2, L3 L1 L1, L2, L3
ts L3 L2, L3
11-14
11-12
21-24
21-22
F: red LED
2CDC 252 003 F0212
R: yellow LED
ts = start-up delay fixed 500 ms
Connection diagram
Technical data
Data at Ta = 25 C and rated values, unless otherwise indicated
Input circuits
Supply circuit = measuring circuit L1, L2, L3
Rated control supply voltage Us = measuring voltage 3 x 200-500 V AC
Rated control supply voltage Us tolerance -15...+10 %
Rated frequency 50/60 Hz
Frequency range 45-65 Hz
Typical current / power consumption 400 V AC 16 mA / 11 VA
Timing circuit
Start-up delay tS fixed 500 ms
User interface
Indication of operational states
Relay status R1, R2 R: yellow LED V Output relay energized
Fault message F: red LED V Phase failure
W Phase sequence error
1) Closed-circuit principle: output relays de-energize if the measured value exeeds/drops below the threshold.
General data
MTBF on request
Duty time 100 %
Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight Screw connection Easy Connect Technology
technology (push-in)
net weight 0.128 kg (0.282 lb) 0.120 kg (0.265 lb)
gross weight 0.156 kg (0.344 lb) 0.147 kg (0.324 lb)
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units vertical/ horizontal 10 mm (0.39 in) if the control supply voltage is higher than 440 V
Degree of protection housing / terminal IP50 / IP20
Electrical connection
Screw connection Easy Connect
technology Technology (push-in)
Wire size finestrand with(out) wire end ferrule 1 x 0.5-2.5 mm 2 x 0.5-1.5 mm
(1 x 20-14 AWG) (2 x 20-16 AWG)
2 x 0.5-1.5 mm
(2 x 20-16 AWG)
Isolation data
Rated impulse withstand voltage Uimp supply circuit / output circuit 6 kV
(IEC/EN 60947-1, IEC/EN 60664-1) output circuit 1/output circuit 2 4 kV
Pollution degree (IEC/EN 60664-1) 3
Overvoltage category (IEC/EN 60664-1) III
Rated insulation voltage Ui supply circuit / output circuit 600 V
(IEC/EN 60947-1, IEC/EN 60664-1)
output circuit 1 / output circuit 2 300 V
Basic insulation for rated control supply voltage supply circuit / output circuit 600 V AC
(IEC/EN 60664-1)
Standards
Product standard IEC/EN 60255-1, IEC/EN 60255-27, EN 50178
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS Directive 2002/95/EC
Technical diagrams
V V
300 300
V 200 V 200
resistive load
resistive load
100 100
80 80
60 60
50 50
40 40
30 30
20 20
2CDC 252 194 F0205
1.0
Switching cycles
0.9
0.8
F
0.7 250 V
resistive load
0.6
0.5
2CDC 252 192 F0205
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
cos
2CDC 252 148 F0206
Contact lifetime
113.4 4.47
105.9 4.17 22.5 0.89
85.6 3.37
Accessories
8 0.32
22.5 0.89 4.8 0.19
68 2.68
0.453
11.5
0.256
62.5 2.461
6.5
0.315
2CDC 252 008 F0010
0.787
3A11
8
10
20
Further documentation
Document title Document type Document number
Electronic Products and Relays Catalog 2CDC 110 004 C02xx
CM-PAS, CM-PFS, CM-PSS, CM-PVS Instruction manual 1SVC 630 510 M0000
You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products ->
Electronic Relays and Controls -> Three Phase Monitors
Note:
We reserve the right to make technical changes
or modify the contents of this document without
prior notice. With regard to purchase orders, the
agreed particulars shall prevail. ABB AG does
not accept any responsibility whatsoever for
potential errors or possible lack of information in
this document.